Vous êtes sur la page 1sur 15

Sistema de Bombas en

Bomba A 2800 RPM


serie
N° medición Voltaje (V) Corriente (A) Fuerza (N) Caudal (L/s) P1 (Bar) P2 (Bar)
1 215 6 23 3.18 -0.2 1.5
2 230 5.5 21 2.67 -0.2 1.7
3 230 5 19 2.05 -0.2 2
4 240 5 17.5 1.59 -0.2 2.1
5 240 4 13 0.89 -0.2 2.2

Sistema de Bombas en
Bomba B 2800 RPM
serie
N° medición Voltaje (V) Corriente (A) Fuerza (N) Caudal (L/s) P4 (Bar) P5 (Bar)
1 220 2 10 3.18 1.4 0
2 220 2.5 7 2.67 1.6 1.8
3 220 2 8 2.05 1.9 2.6
4 220 2 7 1.59 2.1 3.1
5 220 2 6 0.89 2.2 3.4

Bomba A
N° medición Ha Nma [W] Nea [W] Nha [W]
1 17.33 1112.75 1290.00 539.52
2 19.37 1015.99 1265.00 506.29
3 22.43 919.23 1150.00 450.10
4 23.45 846.66 1200.00 364.97
5 24.46 628.95 960.00 213.17

Bomba B
N° medición Hb Nmb [W] Neb [W] Nhb [W]
1 -14.27 483.81 440.00 -444.31
2 2.04 338.66 550.00 53.29
3 7.14 387.04 440.00 143.21
4 10.19 338.66 440.00 158.68
5 12.23 290.28 440.00 106.59

N° medición Hss Rend. Ss % Nhss [W]


1 0.00 0.00 0.00
2 17.36 33.51 453.90
3 25.54 39.23 512.50
4 30.64 40.24 477.00
5 34.73 32.92 302.60

Curvas Altura v
Curva Caracteristica
n° Medicion Hs [m.c.a] Q[L/s] Q^2 H*(Q^2) Q^4
1 0.00 3.18 1.01E-05 0.00E+00 1.02E-10
2 17.36 2.67 7.13E-06 1.24E-04 5.08E-11
3 25.54 2.05 4.20E-06 1.07E-04 1.77E-11
4 30.64 1.59 2.53E-06 7.75E-05 6.39E-12
5 34.73 0.89 7.92E-07 2.75E-05 6.27E-13
Σ= 108.27 10.38 2.48E-05 3.36E-04 1.78E-10

n*c+a*(ΣQ^2)*a = ΣH 5 2.48E-05 108.27


(ΣQ^2)*c+(ΣQ^4)*a = ΣH*(Q^2) 2.48E-05 1.78E-10 3.36E-04

0.64511046 -89870.46873 c= #NAME?


Matris Aux
-89870.4687 18145386192 a= #NAME?

Curva Caracteristica A
n° Medicion Ha [m.c.a] Q[L/s] Q^2 H*(Q^2) Q^4
1 17.33 3.18 1.01E-05 1.75E-04 1.02E-10
2 19.37 2.67 7.13E-06 1.38E-04 5.08E-11
3 22.43 2.05 4.20E-06 9.42E-05 1.77E-11
4 23.45 1.59 2.53E-06 5.93E-05 6.39E-12
5 24.46 0.89 7.92E-07 1.94E-05 6.27E-13
Σ= 107.03 10.38 2.48E-05 4.86E-04 1.78E-10

n*c+a*(ΣQ^2)*a = ΣH 5 2.48E-05 107.03


(ΣQ^2)*c+(ΣQ^4)*a = ΣH*(Q^2) 2.48E-05 1.78E-10 4.86E-04

0.64511046 -89870.46873 c= #NAME?


Matris Aux
Matris Aux
-89870.4687 18145386192 a= #NAME?

Curva Caracteristica B
n° Medicion Hb [m.c.a] Q[L/s] Q^2 H*(Q^2) Q^4
1 -14.27 3.18 1.01E-05 -1.44E-04 1.02E-10
2 2.04 2.67 7.13E-06 1.45E-05 5.08E-11
3 7.14 2.05 4.20E-06 3.00E-05 1.77E-11
4 10.19 1.59 2.53E-06 2.58E-05 6.39E-12
5 12.23 0.89 7.92E-07 9.69E-06 6.27E-13
Σ= 17.33 10.38 2.48E-05 -6.43E-05 1.78E-10

n*c+a*(ΣQ^2)*a = ΣH 5 2.48E-05 17.33


(ΣQ^2)*c+(ΣQ^4)*a = ΣH*(Q^2) 2.48E-05 1.78E-10 -6.43E-05

0.64511046 -89870.46873 c= #NAME?


Matris Aux
-89870.4687 18145386192 a= #NAME?

Curvas ajustadas Serie, Grafico Altura vs Caudal


45

40

35

30

25
H [m.c.a]

20

15

10

0
0 1 2 3 4 5 6

Q[L/s]

Curva Ajust. del Sist. Curva Ajust. B Curva Ajust. A

Curvas Reales Serie, Grafico Alturas v/s Caudal


40

30

20
[m.c.a]

10
Curvas Reales Serie, Grafico Alturas v/s Caudal
40

30

20

H [m.c.a]
10

0
0.80 1.30 1.80 2.30 2.80 3.30

-10

-20
Q[L/s]

datos reales Bomba A Bomba B


Sistema de Bombas en
Bomba A 2800 RPM
paralelo
Corriente
P3 (Bar) N° medición Voltaje (V) Fuerza (N) Caudal (L/s)
(A)
1.4 1 240 8 30 5.03
1.6 2 220 6.5 25.5 3.96
1.8 3 230 6 23.5 3.28
2 4 220 5 18 2.28
2.1 5 220 4 13.5 1.46

Sistema de Bombas en
Bomba B 2800 RPM
paralelo
Corriente
P6 (Bar) N° medición Voltaje (V) Fuerza (N) Caudal (L/s)
(A)
0 1 220 2 7 2.24
1.7 2 220 2 5 1
2.5 3 220 1 4 -0.42
3 4 220 1 5 -0.75
3.4 5 220 1.5 5 -1.06

Bomba A
N° medición Ha Nma [W] Nea [W] Nha [W]
1 8.15 1451.42 1920.00 401.60
2 15.29 1233.70 1430.00 592.81
3 18.35 1136.94 1380.00 589.22
4 20.39 870.85 1100.00 455.09
5 22.43 653.14 880.00 320.56

Bomba B
N° medición Hb Nmb [W] Neb [W] Nhb [W]
1 5.10 338.66 440.00 111.78
2 13.25 241.90 440.00 129.74
3 15.29 193.52 220.00 -62.87
4 17.33 241.90 220.00 -127.25
5 20.39 241.90 330.00 -211.58

N° medición Hss Rend. Ss % Nhss [W] Qs [L/s]


1 0.00 0.00 0.00 7.27
2 9.19 30.25 446.40 4.96
3 12.26 25.80 343.20 2.86
4 15.32 20.62 229.50 1.53
5 18.39 8.04 72.00 0.40

Curvas Altura v/s Caudal


Curva Caracteristica
n° Medicion Hs [m.c.a] Q[L/s] Q^2 H*(Q^2)
1 0.00 7.27 5.29E-05 0.00E+00
2 9.19 4.96 2.46E-05 2.26E-04
3 12.26 2.86 8.18E-06 1.00E-04
4 15.32 1.53 2.34E-06 3.59E-05
5 18.39 0.40 1.60E-07 2.94E-06
Σ= 55.16 17.02 8.81E-05 3.65E-04
si Entonces
Q[L/s] H [m.c.a]
0 39.64 n*c+a*(ΣQ^2)*a = ΣH 5 8.81E-05
1 36.01 (ΣQ^2)*c+(ΣQ^4)*a = ΣH*(Q^2) 8.81E-05 3.47E-09
2 25.11
3 6.95 0.36203773 -9192.58672 c=
Matris Aux
3.30 0.15841256 -9192.58672 521506026 a=

Curva Caracteristica A
n° Medicion Ha [m.c.a] Q[L/s] Q^2 H*(Q^2)
1 8.15 5.03 2.53E-05 2.06E-04
2 15.29 3.96 1.57E-05 2.40E-04
3 18.35 3.28 1.08E-05 1.97E-04
4 20.39 2.28 5.20E-06 1.06E-04
5 22.43 1.46 2.13E-06 4.78E-05
Σ= 84.61 16.01 5.91E-05 7.97E-04
si Entonces
Q[L/s] H [m.c.a]
0 25.35 n*c+a*(ΣQ^2)*a = ΣH 5 5.91E-05
1 #NAME? (ΣQ^2)*c+(ΣQ^4)*a = ΣH*(Q^2) 5.91E-05 1.03E-09
2 #NAME?
3 #NAME? 0.6160401 -35215.3175 c=
Matris Aux
Matris Aux
4 #NAME? -35215.3175 2980766968 a=
5 #NAME?
5.63 #NAME?

Curva Caracteristica B
n° Medicion Hb [m.c.a] Q[L/s] Q^2 H*(Q^2)
1 5.10 2.24 5.02E-06 2.56E-05
2 13.25 1.00 1.00E-06 1.33E-05
3 15.29 -0.42 1.76E-07 2.70E-06
4 17.33 -0.75 5.63E-07 9.75E-06
5 20.39 -1.06 1.12E-06 2.29E-05
Σ= 71.36 1.01 7.88E-06 7.42E-05
si Entonces
Q[L/s] H [m.c.a]
0 16.96 n*c+a*(ΣQ^2)*a = ΣH 5 7.88E-06
1 #NAME? (ΣQ^2)*c+(ΣQ^4)*a = ΣH*(Q^2) 7.88E-06 2.78E-11
2 #NAME?
2.49 #NAME? 0.3616334 -102557.964 c=
Matris Aux
-102557.964 6.5074E+10 a=

Curvas ajustadas Paralelo, Grafico Altura vs Caudal


30

25

20
H [m.c.a]

15

10

0
-2 -1 0 1 2 3 4 5 6 7 8

Q[L/s]

Curva Ajust. Del Sist. Curva Ajust. A Curva Ajust. B

Curvas Reales Paralelo, Grafico Alturas v/s Caudal


25

20

15
[m.c.a]
Curvas Reales Paralelo, Grafico Alturas v/s Caudal
25

20

15

H [m.c.a]
10

0
0.80 1.80 2.80 3.80 4.80 5.80 6.80 7.80
Q[L/s]

datos reales Bomba A Bomba B


2800 RPM
Curvas Reales Paralelo, Poten
P1 (Bar) P2 (Bar) P3 (Bar)
-0.4 0.4 0
Caudal
-0.3 1.2 0.9 700
-0.3 1.5 1.2 600
-0.2 1.8 1.5 500
-0.2 2 1.8
400
300

Nh [W]
200
2800 RPM
100
P4 (Bar) P5 (Bar) P6 (Bar) 0
-1.50 -0.50 0.50 1.50 2.50 3.50
-0.2 0.3 0.2 -100
-0.2 1.1 1
-200
-0.1 1.4 1.4
-300
0 1.7 1.6
0 2 1.9 Q[L/s]

Nh del Sistema Nh bomba A

Curvas Reales Serie, Potenc


Caudal
600

400

200
Nh [W]

0
0.5 1 1.5 2

-200

-400

-600

Q[L/s]

Nh del Sistema Nh bomba A


-600

Q[L/s]

Nh del Sistema Nh bomba A

Q[L/s] Hbr [m.c.a]


0.00 0.32

1 0.37

2 0.51
3 0.74
Q^4 4 1.07
2.79E-09 5 1.49
6.05E-10 6 2.00
6.69E-11 si Entonces
5.48E-12 Q[L/s] H [m.c.a]
2.56E-14 0 16.61
3.47E-09 1 16.29
2 15.35
3 13.76
55.16 4 11.55
3.65E-04 5 8.70
6 5.22
#NAME? 7 1.10
#NAME? 7.23 0.06637881

Q^4 Q[L/s] Hbr [m.c.a]


6.40E-10 0 0.32
2.46E-10 1 0.38
1.16E-10 2 0.54
2.70E-11 si Entonces 3 0.82
4.54E-12 Q[L/s] H [m.c.a] 4 1.22
1.03E-09 0 24.04 5 1.72
1 23.44 6 2.34
2 21.63 7 3.07
84.61 3 18.62
7.97E-04 4 14.40
5 8.97
#NAME? 6 2.34
#NAME? 6.30 0.10

Q^4
2.52E-11
1.00E-12
3.11E-14
3.16E-13
1.26E-12
2.78E-11 si Entonces
Q[L/s] H [m.c.a]
-1.06 15.40
71.36 -1.00 15.71
7.42E-05 0 18.20
1 15.71
#NAME? 2 8.23
#NAME? 2.70 0.07

Altura vs Caudal

5 6 7 8

Curva Ajust. B

turas v/s Caudal


turas v/s Caudal

5.80 6.80 7.80

Bomba B
eales Paralelo, Potencia hidraulica v/s
Caudal

50 1.50 2.50 3.50 4.50 5.50 6.50 7.50 8.50

Q[L/s]

Nh del Sistema Nh bomba A Nh Bomba B

Reales Serie, Potencia hidraulica v/s


Caudal

1.5 2 2.5 3 3.5

Q[L/s]

Nh del Sistema Nh bomba A Nh Bomba B


Q[L/s]

Nh del Sistema Nh bomba A Nh Bomba B

Punto de Operacion Optimo Serie, Grafico Altura vs


Caudal
45
40
35
30
25
H [m.c.a]

20
15
10
5
0
0 1 2 3 4 5 6 7

Q[L/s]

Curva Ajust. del Sist. Curva Ajust. B


Curva Ajust. A Curva Hbr

Punto de Operacion Optimo Paralelo, Grafico Altura


vs Caudal
30

25

20
H [m.c.a]

15

10

0
-2 -1 0 1 2 3 4 5 6 7 8

Q[L/s]

Curva Ajust. Del Sist. Curva Ajust. A


Curva Ajust. B Hbr
5

0
-2 -1 0 1 2 3 4 5 6 7 8

Q[L/s]

Curva Ajust. Del Sist. Curva Ajust. A


Curva Ajust. B Hbr

Vous aimerez peut-être aussi