6 Mechanical properties
6.1 Tensile strength, proof stress and elongation Pipes shall be tested in ac-
cordance with 13.2 and their tensile strength, proof stress, and elongation shall be
as given in table 3.
Remarks 1 When a tensile test is carried out with No. 12 or No. 5 test piece for pipes of un-
der 8 mm in wall thickness, the minimum elongation shall be calculated by sub-
tracting 1.5 % from the elongation given in table 3 for each decrease of 1mm from
8 mm in wall thickness, and rounded off to integers in accordance with Rule A of
JIS Z 8401. Examples of calculation are given in Informative table 1.