Vous êtes sur la page 1sur 1

A B B.3 B.

9 C
A B B.3 B.9 C D E E.9 F
EMISSIONS ET REVISIONS
20' - 8 1/2" 18' - 9" 18' - 9" 21' - 10" 13' - 8 1/2"
8' - 11" 8
4' - 11 1/2" 2' - 9" 6"
Bâtiment Bâtiment 4' - 10" EL.: 4' - 2" 1 2013.03.01 ÉMIS POUR SOUMISSION
8" 4 1 Étage 10 à 11 Étages SIGNÉ & SCELLÉ PAR F. BEDARD
S-200 EL.: 4' - 2" 2 2013.03.18 ÉMIS POUR PERMIS

1' - 4"
3 DESSUS MURET
SIGNÉ & SCELLÉ PAR F. BEDARD

1' - 4"
8 TYP. S.I.C.

2' - 4"
S-200

1' - 0"
1' - 4"
3 2013.04.08 ÉMIS POUR ADDENDA No.1
8" 10' - 10 1/4" 8"
SIGNÉ & SCELLÉ PAR F. BEDARD

2' - 5 3/8"
4 2014.06.08 ÉMIS POUR CONSTRUCTION COFFRAGE ET EXCAVATION

3"
2
SIGNÉ & SCELLÉ PAR F. BEDARD

expert conseils
33 ST-JACQUES , MONTREAL (QUEBEC) , H2Y 1K9
1' - 0 1/2" S-201
5 2015.01.13 ÉMIS POUR CONSTRUCTION
7

Fax.: (514) 282-0100


2' - 8" SIGNÉ & SCELLÉ PAR FRANÇOIS BISSON
1
EL.: 4' - 2" 10" MASSIF ÉLECTRIQUE EN LIGNE 4' - 10" 6 2015.01.05 ÉMIS POUR COORDINATION RDC - MEZZANINE
AVEC PÉRIMÈTRE S-201
3 DESSUS MURET 8' - 2 1/4" 4' - 8" 5' - 2 1/4" SIGNÉ & SCELLÉ PAR FRANÇOIS BISSON
Bâtiment en construction

TYP. S.I.C. DU BÂTIMENT JUSQU'À LA EL.: 4' - 2"


S-200 RUE UNION 1' - 3" 7 2015.04.13 ÉMIS POUR CONSTRUCTION

8" MURET
7

TYP. S.I.C.
Altitude phase 2

STRUCTURE D'ACIER VOIR ÉLECTRIQUE + SIM.


7 SIGNÉ & SCELLÉ PAR FRANÇOIS BISSON
PAR MÉTAUX NORME E21-11 (5e ÉDITION) S-202

Tel.: (514) 282-8100


3' - 7"
11' - 6 1/4" OUVRÉS ET DÉTAILS SUR S-006 S-202 8 2015.04.13 ÉMIS POUR CONSTRUCTION
TYP.
1' - 0 1/2"
9"
6.5 SIGNÉ & SCELLÉ PAR FRANÇOIS BISSON

2' - 6"
9 2015.05.22 ÉMIS POUR CONSTRUCTION
3' - 5" 4 1/4"
7

PASQUIN ST-JEAN
2' - 8" SIGNÉ & SCELLÉ PAR FRANÇOIS BISSON

8' - 3 1/2"
8"

DALLE 5" ÉP. 8" 7"

5' - 7 1/8"
1
SUR ISOLANT 10 2015.06.16 ÉMIS POUR DIRECTIVE S-01
8' - 2 1/4" 4' - 8" 23' - 4 1/4" 7" S-204 4" EL.: 3'-8" SIGNÉ & SCELLÉ PAR LATYR NIANG

9 1/2"

2 1/2"
DALLE 6" ÉP.
SUR ISOLANT RIGIDE

8"
7 C.M. ADDITIONNELLE 11 2015.08.03 ÉMIS POUR DIRECTIVE S-01 REV.01

1' - 7"
8" MURET
8' - 3"

EL.: 4'-0"

TYP. S.I.C.
SECTION DALLE SUR ISOLANT
S-202
3.55 KPa
EL.: 4' - 2" MASSIF ÉLECTRIQUE
6 SIGNÉ & SCELLÉ PAR LATYR NIANG
3' - 7"

12 2015.10.09 ÉMIS POUR DIRECTIVE S-03

3' - 6"
TYP. & BASSIN D'HUILE

20' - 0"
7"
4 +/- 9' - 0" 5
6.5 2 3/4"
S-202 VOIR ARCH.
SUSPENDUS
S-204 EL.: 4' - 2"
SIGNÉ & SCELLÉ PAR
13 2015.11.18
LATYR NIANG
ÉMIS POUR DIRECTIVE S-05
2 3/4" 8" 8" 6' - 3" DALLE 9"@12" ÉP.
1 SIGNÉ & SCELLÉ PAR LATYR NIANG

8' - 3 1/2"
3 EL.: 3'-8" PT. HT.

6' - 5"

8' - 4"
9' - 4"

S-204 1' - 0 1/2" 14 2015.12.04 ÉMIS POUR DIRECTIVE S-06


8"

4' - 4 1/2"
S-206

±2%
4" 7 SIGNÉ & SCELLÉ PAR JONATHAN-ALEXANDRE DAVIS
1' - 2"

EL.: 3'-5"
EL.: 3' - 8"

4' - 7 1/4"
S-204 PT. B. 15 2015.12.15 ÉMIS POUR DIRECTIVE S-07
MASSIF ÉLECTRIQUE EN LIGNE 7' - 1 1/8"

25' - 7"
AVEC PÉRIMÈTRE ±2% ±2% SIGNÉ & SCELLÉ PAR JONATHAN-ALEXANDRE DAVIS
DU BÂTIMENT JUSQU'À LA 6 4 9 1/2" STRUCTURE EL.: 4' - 2"

8 1/2"
2 1/2"

3' - 10"
1' - 1"
16 2016.03.09 ÉMIS POUR DIRECTIVE S-14

1' - 0 1/2"
TIGE, D'ACIER PAR

5' - 0"
RUE UNION
1' - 8"

S-206
VOIR COUPE 8" MÉTAUX

±2%
VOIR ÉLECTRIQUE + 8"

5' - 0 1/2"
W150x30 5 1' - 6" EL.: 4' - 2" SIGNÉ & SCELLÉ PAR JONATHAN-ALEXANDRE DAVIS
NORME E21-11 (5e ÉDITION) 1' - 6" OUVRÉS
BASSIN D'HUILE 2' - 0 1/2"
17 2016.03.25 ÉMIS POUR DIRECTIVE S-14 REV.01
0

ET DÉTAILS SUR S-003 S-204

3' - 9"
19' - 9" 8' - 4" 10' - 5"
VOIR NOTE

PAR D'AUTRES,
11 SIGNÉ & SCELLÉ PAR JONATHAN-ALEXANDRE DAVIS
SUR STRUCTURE
± 7' - 7"
C150x19

C150x19

C150x12

8"
5
6"

3 SUSPENDUE. S-202

10 3/4"
8"

5' - 3 7/8"
5' - 4 1/2"
S-206 CHAMBRE ANNEXE
4' - 10" 2

20' - 0"
10" PREVOIR ETRIERS
0

W150x30 1' - 0" S-204 DE TIRAGE, VOIR S-107A


2' - 9" 7' - 1 1/8" 8" MUR 2' - 0" 3"

7"
= = =
1' - 1 1/2" 3' - 4"

9' - 7 3/4"
1' - 6"

4.7
11' - 6"

7' - 7"
7"
VOIR NOTE
4"
8" 5.1 3
6" STRUCTURE D'ACIER S-107A

4"
1' - 0" 19' - 3"

2' - 9"
PAR MÉTAUX

2"
OUVRÉS
5 CARACTÉRISTIQUE DU PLANCHER - REZ-DE-CHAUSSÉE (HAUT)

3' - 8"
8" MUR
5' - 11 7/8"
1' - 0 1/2"

2 ÉCHELLE : 1/8"= 1'-0"


2 2' - 4" 1' - 6"
S-204
S-200 - DALLE STRUCTURALE 5" ÉP. SUR ISOLANT RIGIDE DESSUS ÉL.: 4'-8" S.I.C.
1 - POUR OUVERTURES MÉCANIQUE, VOIR PLAN DE MÉCANIQUE
(POUR LES DIMENSIONS ET LA LOCALISATION PRÉCISES DES OUVERTURES DE
9" 4 1/2" S-107A
2 1/4"

4.7 MÉCANIQUE, VOIR PLANS DE MÉCANIQUE ET D'ARCHITECTURE).


- DÉTAILS TYPIQUES, VOIR PLAN S-002 B B.3 2
B.9 C D PLANCHER HAUT
P120- 10" x VARIABLE

10"
1 1/2" - NOTES GÉNÉRALES, VOIR PLAN S-001 S-206
ÉCHELLE : 1/8"= 1'-0"

23' - 10 1/2"
- 2 MANCHONS DE 150mm DIA. SONT AUTORISÉS PRÈS DES COLONNES
C.M. ADDITIONNELLE 5 8" 27' - 8" 8"
INTÉRIEURES S.I.C. (VOIR NOTE GÉNÉRALE 5C)
DALLE 9"@12" ÉP. SECTION COMMERCIALE - DALLE STRUCTURALE 12" ÉP. DESSUS ÉL.: 4'-8" S.I.C.
S-202 3' - 9"
EL.: -2'-0" PT. HT. 0.50 KPa EL.: -0'-1 1/2" - POUR OUVERTURES MÉCANIQUE, VOIR PLAN DE
27' - 7"

23' - 3"

3 DÉPRESSION MÉCANIQUE (POUR LES DIMENSIONS ET LA


1" 1' - 3 1/2"
VOIR ARCH. EL.: 4' - 8" LOCALISATION PRÉCISES DES OUVERTURES DE
S-204 1 MÉCANIQUE, VOIR PLANS DE MÉCANIQUE ET
EL.: -2'-3"
S-500 ARCHITECTURE).

8"
PT. B.

2"
4.1 DALLE 2e COULÉE
2 - DÉTAILS TYPIQUES, VOIR PLAN S-002
- NOTES GÉNÉRALES, VOIR PLAN S-001

1' - 0"
1' - 0" 1' - 8"
2' - 1 3/4"

AXE - 2 MANCHONS DE 150mm DIA. SONT AUTORISÉS PRÈS

10"
BÉTON 30 MPa ou 35 MPa
P107 - 10" x 24" (VOIR TABLEAU 5B.3) DES COLONNES INTÉRIEURES S.I.C. VOIR NOTE
GÉNÉRALE 5C.
3"

DALLE 1er COULÉE


4
CL

3' - 3"
BÉTON 60 MPa

2' - 3"

11' - 9 5/8"
3' - 1"

2"
8
5' - 0"

P103 - 12" x 65"


4"
DALLE 12" ÉP. MURET 8" x 6" DE HAUT.
3' - 2"

PROJET

15M@300 H & B
S-204 S-204 EL.: 4'-8" DESSUS EL.: 5'-2"
P107 - 10" x 24"
1' - 6" 3.9 +ISOLANT 6''
TYP.
+DALLE 5'' Tom Condominiums
5' - 2 3/4"
P101 - 12" x 33½"

P100 - 12" x 33½" 2' - 0 1/2" 2' - 0" 7' - 4" 1' - 0" +TREILLIS 6X6
6" 11
EL.: 0"
1' - 6"
9 8" rue Union, Montréal
1' - 0"

20' - 0"
S-202
S-204
AXE
4' - 10"

20M@300
8"
H&B
7' - 1"

2' - 8"
1
4' - 7 1/2"

1' - 1"

EL.: 5' - 2"

3 1
1' - 0"
1/2"

COL. DE BÉTON
S-206
NOTE: LE BÉTON DE 2e COULÉE DOIT ÊTRE MIS EN PLACE KARL FISCHER ARCHITECT
1' - 6" 1' - 0 1/2" ET VIBRÉ ALORS QUE LE BÉTON DE 1er COULÉE
1' - 0" 7' - 3" 1' - 6" EST ENCORE FRAIS AFIN D'ÉVITER UN JOINT FROID ENTRE
DESSUS MURET
LES 2 TYPES DE BÉTON.
EL.: 5'-2"
LORSQUE LE BÉTON RESTE APPARENT, PRÉPARER
4 LES MÉLANGES DE BÉTON DE FAÇON À CE QUE LA
PIGMENTATION DES DIFFÉRENTS BÉTONS SOIT IDENTIQUE. DALLE 2e COULÉE
S-202 POUR LOCALISATION, VOIR VUE EN PLAN (COORDONNER DE BÉTON 60 MPa

20' - 0"
9" AVEC ARCH.). SCEAU
4' - 10" 500 DALLE ET POUTRE 3e 500
500 MIN. COULÉE DE BÉTON MIN.
30 MPa ou 35 MPa

COL.

COL.
MIN.
(VOIR TABLEAU 5B.3)

COL.
CL 3
1' - 3 1/2" 1" 9" 1' - 0 1/2"
S-207

rue Union, Montréal


DALLE 1er COULÉE
2"

10"

1"
2"

MP-SS1-01 - 12" x 9'-9" MP-SS1-02 - 12" x 9'-9"


1"

DALLE 1er COULÉE

COL.
DE BÉTON 60 MPa
2
CL

CL

COL.
CL
CL

DE BÉTON 60 MPa

COL.
2 1/2"

JOINT DE COULÉE
10"

10"

POUTRE 1er COULÉE


10"

10"
6"

DE BÉTON 80 MPa
8" 3' - 9" 1' - 3 1/2" EL.: -11"
VARI. 1' - 0" BORDURE BÉTON DALLE SANS PANNEAU SURBAISSÉ
VOIR ARCH. DALLE AVEC POUTRE DALLE AVEC PANNEAU SURBAISSÉ
P106 - 12" x 24"

6" 6 1/2"
8 10' - 0" OUVERTURE
P103 - 12" x 65"

BÉTON HAUTE RÉSISTANCE TÊTE DE COLONNE


S-204 @ 7.25%
36"DIA., 400-60MPa
RAMPE DALLE 12" ÉP. VOIR MÉC. DÉTAIL APPLICABLE À 100% DES COLONNES DE CE PLAN
STRUCTURE D'ACIER EB TITRE
6
PAR MÉTAUX
OUVRÉS
EL.: -2 1/2"
S-202
NOTE:
DÉTAIL 400 APLICABLE DU SS5 @ 23e. ÉTAGE
REZ-DE-CHAUSSÉE
1' - 0 1/2"
BORDURE BÉTON
1

Tom Condominiums
DESSUS MURET VOIR ARCH.
14 Étages
Bâtiment

CARACTÉRISTIQUE DU PLANCHER - REZ-DE-CHAUSÉE


1' - 4"

2' - 4"

S-200 EL.: 5'-2"


ÉCHELLE : 1/8"= 1'-0"
1 INGENIEUR DE PROJET: VERIFIE PAR:
- DALLE STRUCTURALE 9" ÉP. S.I.C. DESSUS ÉL.: 0'-0" S.I.C. NOTE GÉNÉRALE MISE EN PLACE BÉTON 60MPa :
- POUR OUVERTURES MÉCANIQUE, VOIR PLAN DE MÉCANIQUE FRANÇOIS BISSON, ing
8"

(POUR LES DIMENSIONS ET LA LOCALISATION PRÉCISES DES OUVERTURES DE MÉCANIQUE, -LA TENEUR EN AIR, L'AFFAISSEMENT ET LA TEMPÉRATURE DU BÉTON DOIVENT ÊTRE

11-64179
2' - 5 1/2" 11' - 3" 4' - 10" DESSINE PAR: ECHELLE: DATE:
VOIR PLANS DE MÉCANIQUE ET ARCHITECTURE). MESURÉES À LA SORTIE DE LA POMPE.
2' - 8"

- DÉTAILS TYPIQUES, VOIR PLAN S-002 M.A. SIGOUIN Comme indiqué 2012-11-01

S-107
1' - 4"

8" DESSUS MURET DESSUS MURET LIMITE MUR DE DESSUS MURET - NOTES GÉNÉRALES, VOIR PLAN S-001 -LE BÉTON BHP ÉTANT SENSIBLE À FISSURATION PLASTIQUE, UNE CURE HUMIDE EST
1 - 2 MANCHONS DE 150mm DIA. SONT AUTORISÉS PRÈS DES COLONNES INTÉRIEURES S.I.C. INDISPENSABLE: HUMIDIFIER LES SURFACES NON PROTÉGÉES EN APPOSANT DES CONTRAT: PLAN:
4 EL.: 5'-2" EL.: 5'-2" CISAILLEMENT EL.: 3'-2"
S-201 S-206 VOIR SÉRIE S-400 3
(VOIR NOTE GÉNÉRALE 5C.
- POUR LES DIMENSIONS ET LOCALISATION EXACTES DU BASSIN DE'HUILE DE LA CHAMBRE ANNEXE,
PRODUITS DE CURE POUR ÉVITER L'ÉVAPORATION OU EN LE COUVRANT D'UN FILM... 11-64179 S-107
S-201 COORDONNER AVEC MÉCANIQUE ET HYDRO QUÉBEC.

Vous aimerez peut-être aussi