Académique Documents
Professionnel Documents
Culture Documents
PAGE NO. 1
****************************************************
* *
* STAAD.Pro CONNECT Edition *
* Version 22.00.00.15 *
* Proprietary Program of *
* Bentley Systems, Inc. *
* Date= AUG 4, 2023 *
* Time= 19:22:38 *
* *
* Licensed to: only @ ::LAVTeam:: (R) *
****************************************************
1. STAAD SPACE
INPUT FILE: D:\FRANCIS\BILLBOARD FRAME STRUCTURE\Structure1.STD
2. START JOB INFORMATION
3. ENGINEER DATE 12-MAY-23
4. END JOB INFORMATION
5. INPUT WIDTH 79
6. UNIT METER KN
7. JOINT COORDINATES
8. 1 0 0 0; 2 2.56 0 0; 3 0 3 0; 4 2.56 3 0; 5 3.84 3 0; 6 -1.28 3 0; 7 0 3 -0.65
9. 8 2.56 3 -0.65; 9 -1.28 3 -0.65; 10 3.84 3 -0.65; 11 1.28 3 0; 12 1.28 3 -0.65
10. 13 0 1.5 0; 14 2.56 1.5 0; 15 0 2.5 0; 16 2.56 2.5 0; 19 0 2 0; 21 2.56 2 0
11. 23 0 2.5 -0.433333; 24 0 2 -0.216667; 25 2.56 2.5 -0.433333
12. 26 2.56 2 -0.216667; 27 0 3.96 0; 28 2.56 3.96 0; 29 3.84 3.96 0
13. 30 -1.28 3.96 0; 31 1.28 3.96 0; 32 0 4.92 0; 33 2.56 4.92 0; 34 3.84 4.92 0
14. 35 -1.28 4.92 0; 36 1.28 4.92 0; 37 0 5.88 0; 38 2.56 5.88 0; 39 3.84 5.88 0
15. 40 -1.28 5.88 0; 41 1.28 5.88 0; 42 0 3 -0.15; 43 0 3.96 -0.15
16. 44 2.56 3 -0.15; 45 2.56 3.96 -0.15; 46 3.84 3 -0.15; 47 3.84 3.96 -0.15
17. 48 -1.28 3 -0.15; 49 -1.28 3.96 -0.15; 50 1.28 3 -0.15; 51 1.28 3.96 -0.15
18. 52 0 4.92 -0.15; 53 2.56 4.92 -0.15; 54 3.84 4.92 -0.15; 55 -1.28 4.92 -0.15
19. 56 1.28 4.92 -0.15; 57 0 5.88 -0.15; 58 2.56 5.88 -0.15; 59 3.84 5.88 -0.15
20. 60 -1.28 5.88 -0.15; 61 1.28 5.88 -0.15; 66 -1.28 4.92 -0.316667
21. 67 -1.28 3.96 -0.483333; 68 3.84 4.92 -0.316667; 69 3.84 3.96 -0.483333
22. MEMBER INCIDENCES
23. 1 1 13; 2 2 14; 3 3 11; 4 3 6; 5 4 5; 6 7 12; 7 7 9; 8 8 10; 9 3 42; 10 4 44
24. 11 6 48; 12 5 46; 13 11 4; 14 12 8; 15 11 50; 16 13 19; 17 14 21; 20 13 24
25. 21 14 26; 22 15 3; 23 16 4; 24 15 23; 25 16 25; 26 19 15; 27 19 24; 28 21 16
26. 29 21 26; 30 23 7; 31 24 23; 32 25 8; 33 26 25; 34 15 7; 35 19 23; 36 21 25
27. 37 16 8; 38 3 27; 39 4 28; 40 5 29; 41 6 30; 42 11 31; 43 27 31; 44 27 30
28. 45 28 29; 46 31 28; 47 27 32; 48 28 33; 49 29 34; 50 30 35; 51 31 36; 52 32 36
29. 53 32 35; 54 33 34; 55 36 33; 56 32 37; 57 33 38; 58 34 39; 59 35 40; 60 36 41
30. 61 37 41; 62 37 40; 63 38 39; 64 41 38; 65 42 7; 66 42 43; 67 44 8; 68 44 45
31. 69 46 10; 70 46 47; 71 48 9; 72 48 49; 73 50 12; 74 50 51; 75 43 51; 76 43 49
32. 77 45 47; 78 51 45; 79 43 52; 80 45 53; 81 47 54; 82 49 55; 83 51 56; 84 52 56
33. 85 52 55; 86 53 54; 87 56 53; 88 52 57; 89 53 58; 90 54 59; 91 55 60; 92 56 61
34. 93 57 61; 94 57 60; 95 58 59; 96 61 58; 97 60 40; 98 57 37; 99 61 41
35. 100 58 38; 101 59 39; 102 55 35; 103 52 32; 104 56 36; 105 53 33; 106 54 34
36. 107 45 28; 108 47 29; 109 51 31; 110 43 27; 111 49 30; 112 9 67; 113 10 69
37. 114 47 69; 115 49 67; 116 54 68; 117 55 66; 118 66 60; 119 67 66; 120 68 59
38. 121 69 68; 122 48 67; 123 55 67; 124 46 69; 125 54 69; 138 48 42; 139 42 50
*** NOTE: MASS MODEL FORMED WILL BE USED IN SEISMIC/RESPONSE/TIME HISTORY LOADING, IF ANY.
IF MASS MODEL IS SEPARATELY PROVIDED IN INDIVIDUAL LOADING, THE GENERATED MASS
WILL BE REPLACED BY THE MASS PROVIDED IN INDIVIDUAL LOADING.
*** NOTE: If any floor diaphragm is present in the model Wind Load definition
should be defined after Floor Diaphragm definition. Otherwise wind
load generation may be unsuccessful during analysis.
P R O B L E M S T A T I S T I C S
-----------------------------------
139. PARAMETER 1
140. CODE AISC UNIFIED 2016
141. FYLD 345000 MEMB 1 TO 17 20 TO 41 43 TO 73 75 TO 125 138 TO 141
142. METHOD LRFD
143. CHECK CODE MEMB 1 TO 17 20 TO 41 43 TO 73 75 TO 125 138 TO 141
STEEL DESIGN
The capacity results and intermediate results in the report follow the notations
and axes labels as defined in the AISC 360-16 code.
The analysis results are reported in STAAD.Pro axis convention and the AISC 360:16
design results are reported in AISC 360-16 code axis convention.
1. Section classification reported is for the cross section and loadcase that
produced the worst case design ratio for flexure/compression Capacity results.
2. Results for any Capacity/Check that is not relevant for a section/loadcase
based on the code clause in AISC 360-16 will not be shown in the report.
3. Bending results are reported as being “about” the relevant axis (X/Y), while
the results for shear are reported as being for shear forces “along” the axis.
E.g : Mx indicates bending about the X axis, while Vx indicates shear along
the X axis.
144. FINISH
************************************************************
* For technical assistance on STAAD.Pro, please visit *
* http://www.bentley.com/en/support/ *