REPORTE DE CARGAS EN COLUMNAS

PROYECTO: “CONSTUCCION DE AMBIENTE DE USOS MULTIPLES EN EL (LA) IE NIÑO JESUS DE PRAGA, DISTRITO DE SAN ANTONIO, PROVINCIA CAÑETE,
DEPARTAMENTO LIMA”
COLUMNA: CL-50x50x25

Piso Columna Combinacion Ubicación P (t) V2 (t) V3(t) T (t-m) M2 (t-m) M3(t-m) P (t) - Corregida
1.4M+1.7V 0 -20.987 0.386 -1.250 0.034 -1.735 0.2711 20.987
0.9M+SX Max 0 -7.791 0.528 3.257 0.029 8.230 0.4969 7.791
0.9M+SX Min 0 -13.348 -0.256 -4.170 -0.003 -9.499 -0.333 13.348
0.9M+SY Max 0 2.829 3.406 -0.371 0.022 -0.468 3.4897 -2.829
0.9M+SY Min 0 -23.969 -3.134 -0.543 0.004 -0.801 -3.3257 23.969
C2 EJE 2/A

0.9M-SX Max 0 -7.791 0.528 3.257 0.029 8.230 0.4969 7.791


0.9M-SX Min 0 -13.348 -0.256 -4.170 -0.003 -9.499 -0.333 13.348
0.9M-SY Max 3.76 -7.643 0.735 -0.314 -0.015 1.226 2.2639 7.643
0.9M-SY Min 0 -23.969 -3.134 -0.543 0.004 -0.801 -3.3257 23.969
1.25(M+V)+SX Max 0 -15.244 0.709 2.683 0.044 7.433 0.6343 15.244
1.25(M+V)+SX Min 0 -20.801 -0.075 -4.745 0.012 -10.296 -0.1956 20.801
1.25(M+V)+SY Max 0 -14.905 -0.857 -0.826 -0.043 2.573 3.2692 14.905
1.25(M+V)+SY Min 0 -31.421 -2.953 -1.117 0.019 -1.598 -3.1883 31.421
1.25(M+V)-SX Max 0 -15.244 0.709 2.683 0.044 7.433 0.6343 15.244
1.25(M+V)-SX Min 0 -20.801 -0.075 -4.745 0.012 -10.296 -0.1956 20.801
1.25(M+V)-SY Max 0 -13.100 -0.266 -0.900 -0.009 1.578 0.5506 13.100
1.25(M+V)-SY Min 0 -31.421 -2.953 -1.117 0.019 -1.598 -3.1883 31.421
1.4M+1.7V 0 -21.806 1.615 -0.3795 -0.04 -0.2514 2.2158 21.806
0.9M+SX Max 0 -8.5553 4.1457 0.2489 0.0024 0.3306 9.455 8.555
0.9M+SX Min 0 -13.1733 -2.959 -0.5227 -0.0345 -0.4855 -7.8276 13.173
0.9M+SY Max 0 -8.0307 0.5907 3.8015 0.0392 0.2376 -1.284 8.031
0.9M+SY Min 0 -23.8786 0.5291 -3.3067 -0.0257 -3.3807 0.6882 23.879
C2 EJE 2/F

0.9M-SX Max 0 -8.5553 4.1457 0.2489 0.0024 0.3306 9.455 8.555


0.9M-SX Min 0 -13.1733 -2.959 -0.5227 -0.0345 -0.4855 -7.8276 13.173
0.9M-SY Max 0 -8.0307 0.5907 3.8015 0.0392 0.2376 -1.284 8.031
0.9M-SY Min 0 -23.8786 0.5291 -3.3067 -0.0257 -3.3807 0.6882 23.879
1.25(M+V)+SX Max 0 -16.3877 4.8853 0.0732 -0.0149 0.2042 10.4699 16.388
1.25(M+V)+SX Min 0 -21.0057 -2.2194 -0.6984 -0.0518 -0.6119 -6.8126 21.006
1.25(M+V)+SY Max 0 -15.7792 1.2634 5.5925 0.0708 -0.9011 -3.0381 15.779
1.25(M+V)+SY Min 0 -31.711 1.2687 -3.4824 -0.043 -3.5071 1.7031 31.711
1.25(M+V)-SX Max 0 -16.3877 4.8853 0.0732 -0.0149 0.2042 10.4699 16.388
PISO 1

1.25(M+V)-SX Min 0 -21.0057 -2.2194 -0.6984 -0.0518 -0.6119 -6.8126 21.006


1.25(M+V)-SY Max 0 -15.7792 1.2634 5.5925 0.0708 -0.9011 -3.0381 15.779
1.25(M+V)-SY Min 0 -31.711 1.2687 -3.4824 -0.043 -3.5071 1.7031 31.711
1.4M+1.7V 0 -13.155 0.6133 0.7765 0.0778 -0.3878 -1.8509 13.155
0.9M+SX Max 0 -4.6413 3.8145 0.6157 0.0409 -0.1194 3.9911 4.641
0.9M+SX Min 0 -11.6827 -3.1712 -0.2074 -0.042 -0.1684 -8.0715 11.683
0.9M+SY Max 0 5.6723 0.4196 3.4092 -0.0064 1.9888 0.4383 -5.672
0.9M+SY Min 0 -21.1745 0.246 -3.1473 -0.0245 -3.2289 0.2906 21.175
C2 EJE 5/A

0.9M-SX Max 0 -4.6413 3.8145 0.6157 0.0409 -0.1194 3.9911 4.641


0.9M-SX Min 0 -11.6827 -3.1712 -0.2074 -0.042 -0.1684 -8.0715 11.683
0.9M-SY Max 0 5.6723 0.4196 3.4092 -0.0064 1.9888 0.4383 -5.672
0.9M-SY Min 0 -21.1745 0.246 -3.1473 -0.0245 -3.2289 0.2906 21.175
1.25(M+V)+SX Max 0 -8.5504 4.0694 0.8617 0.0763 -0.2302 3.2049 8.550
1.25(M+V)+SX Min 0 -15.1164 -2.8239 -0.0235 -0.0609 0.0563 -7.5884 15.116
1.25(M+V)+SY Max 0 -9.3171 0.6015 2.9208 0.0745 0.9576 -1.394 9.317
1.25(M+V)+SY Min 0 -24.6082 0.5932 -2.9634 -0.0434 -3.0042 0.7736 24.608
1.25(M+V)-SX Max 0 -8.5504 4.0694 0.8617 0.0763 -0.2302 3.2049 8.550
1.25(M+V)-SX Min 0 -15.1164 -2.8239 -0.0235 -0.0609 0.0563 -7.5884 15.116
1.25(M+V)-SY Max 0 -9.3171 0.6015 2.9208 0.0745 0.9576 -1.394 9.317
1.25(M+V)-SY Min 0 -24.6082 0.5932 -2.9634 -0.0434 -3.0042 0.7736 24.608
1.4M+1.7V 0 -55.6133 2.6664 -0.5921 -0.0001 -0.8207 3.8014 55.613
0.9M+SX Max 0 -5.2436 -0.2605 3.0406 -0.0187 5.2919 0.3144 5.244
0.9M+SX Min 0 -11.3335 -0.4649 -3.748 -0.0099 -8.8657 -0.5296 11.334
0.9M+SY Max 0 -5.5232 1.7549 -0.2645 -0.0255 1.0677 1.4798 5.523
0.9M+SY Min 0 -20.8916 -3.2981 -0.4755 0.0092 -0.6903 -3.479 20.892
C2 EJE 5/F

0.9M-SX Max 0 -5.1109 -0.1078 2.9203 0.0013 1.8138 0.0444 5.111


0.9M-SX Min 0 -11.3335 -0.4649 -3.748 -0.0099 -8.8657 -0.5296 11.334
0.9M-SY Max 0 -5.5232 1.7549 -0.2645 -0.0255 1.0677 1.4798 5.523
0.9M-SY Min 0 -20.8916 -3.2981 -0.4755 0.0092 -0.6903 -3.479 20.892
1.25(M+V)+SX Max 0 -5.8384 0.0455 0.9935 0.0768 1.9042 0.0529 5.838
1.25(M+V)+SX Min 0 -6.8646 0.037 -0.9952 -0.0776 -1.9048 0.0418 6.865
1.25(M+V)+SY Max 0 -9.5038 1.5193 -0.5835 -0.0671 2.0453 1.5802 9.504
1.25(M+V)+SY Min 0 -24.4099 -3.4737 -0.9014 0.0314 -1.2725 -3.6982 24.410
1.25(M+V)-SX Max 0 -5.2436 -0.2605 3.0406 -0.0187 5.2919 0.3144 5.244
1.25(M+V)-SX Min 0 -11.3335 -0.4649 -3.748 -0.0099 -8.8657 -0.5296 11.334
1.25(M+V)-SY Max 0 -5.5232 1.7549 -0.2645 -0.0255 1.0677 1.4798 5.523
1.25(M+V)-SY Min 0 -20.8916 -3.2981 -0.4755 0.0092 -0.6903 -3.479 20.892
REPORTE DE CARGAS EN COLUMNAS
PROYECTO: “CONSTUCCION DE AMBIENTE DE USOS MULTIPLES EN EL (LA) IE NIÑO JESUS DE PRAGA, DISTRITO DE SAN ANTONIO, PROVINCIA CAÑETE,
DEPARTAMENTO LIMA”
COLUMNA: CL-50x50x25