Vous êtes sur la page 1sur 3

A B C D E F F1 G

11700

1750 2250 1350 1850 2650 350 1485

2098 1000 1252 1000 1748 1850 1752 1000 150

1 W1 W2 1
2075
2000

2000
4103
2 2
543 478 900

D2

D1
1453

1453
EXIT

3 W4 3
2000

2000
467 1000 656 1000
W4

W4
D2
1850

W1

4 W2 4
1450

D2

W4
1967

5 5

3850
UP

1850
2407

W3
1845

W1

6 6
900 914

2328

22828
2493

2524
22028

D1

D1

6a 6a
721

3150
1850

4176
W3
W1
3400

1972

1448
300
7 D2 D1
7
1800

1800
10001481000

W4

3150

8 8
W3

D1
W4
1700

1700
200

9 D2 D1
W3
9
3200

2423
2500

3325

10 W1
10
1028
825

827

10a 10a
ENTR.

1673 300 1850 1375 300 218 900 1584 3500 150

1750 2250 1350 1500 3000 350 1500

11700

A B C D E F F1 G

GROUND FLOOR PLAN


A B C D E F F1 G

11700

1750 2250 1350 1850 2650 350 1485

2098 1000 1252 1000 1748 1850 1752 1000 150

1
W1 W2 1
2000

2000
2
3453

4103
2
1453

1453
3
3
1000 543

W4
2000

2000
467 1000 656 1000
W4

W4
4
D2

D2
1171
1450

1450
5
1850

D1
5
W1

1850
2407

2400
W3
1361

6 DOWN

2203
1850

22652
2368

2399
W1
21852

D1

6a
822

6a

3150
1850

4176
W3
W1
3400

300 648
1972

7 D2 D1
7
1800

1800
1000

W4

3150

8 150 8
W3

D1
1000

W2
W4
1700

1700
200

9 D2
W3
9
1156

3200

2178

2500

7a D1
7a
1344

10 W1
10
1042
773

773
827

11 11

1673 300 1850 1375 300 218 900 1584 3500 150

1750 2250 1350 1500 3000 350 1500

11700

A B C D E F F1 G

FIRST FLOOR PLAN


A B C D G

11700

1750 2250 1350 6335


A

75mm kicker
1100 1100

150

600
450
F1 F1

1100

1100
1 1

1400
C1 C1

500
STRIP FOOTING

800
2000

2000
foundation bed

300
STRIP FOOTING

STRIP FOOTING
1100 1100
2 2 450 column base
H.C.F

1453

1453
1100
+600
F1 F1

1100

1100
3 C1 C1
3 SECTION 01 - 01
1100
scale = 1: 50
2000

2000
H.C.F H.C.F
+450
+450
STRIP FOOTING
F1 F1 F1

1100
4 C1 C1 C1
4 9 10

2500

3850
3857

H.C.F
STRIP FOOTING

STRIP FOOTING
+600 75mm kicker 75mm kicker

150
H.C.F

600
450
+600
F2

1400
6 6

500
C1
STRIP FOOTING

800
1100 1100
2493

2524
foundation bed

300
22028

22028
STRIP FOOTING
450 450
F1 F1 H.C.F
1100

1100

6a C1 C1
+600 6a 1100 2025
STRIP FOOTING

SECTION 02 - 02
3400

3400
2070 scale = 1: 50
H.C.F
+600
F1
STRIP FOOTING F3

1200
7 C1 C2
7
H.C.F 6
1800

1800
+450
F1 F1 H.C.F
8 C1 C1
+600 8 75mm kicker
1700

1700
H.C.F

150
STRIP FOOTING

+450

600
STRIP FOOTING

450
F1
9 H.C.F C1
9

1400
+600

500
1100
2500

2500

800
H.C.F
+450 foundation bed

300
F1 F3 F3 STRIP FOOTING F4
1100

10 10 450 column base


2070

2025
825

825
C1
1100
10a C2 C2 C3
10a
SECTION 03 - 03
1200 1300 scale = 1: 50

1750 2250 1350 6352

11700

A B C D G

FOUNDATION PLAN

Vous aimerez peut-être aussi