1 2 3 4 5 Keyplan

6
2C

4C
1A

1B

2A

2B

4B
4A
3

P
C H AN GIN G
LOCK ER S &

-1

FI R ST AI D
BD1 GF1

BD1 GF7
R OOM
-
MA LE

I N TER V EI W
-9
MA LE WC /
S H OWE R
BD1 GF1

GF3
R OOM
-
MA EL PR A YE R

-6

BD1
R OOM
BD1 GF1

R E C EP TIO N
GF1
-
C ONFER A NC E
-3
C A NTEE N
BD1 GF1

-2
BD1 GF1
R OOM

BD1
GF5
S TA RI -1
-
S H OWE R FS FCA S D
FE MALE WC /

BD1
-7

10591
BD1 GF1
QSS2-JEG-CW-00-DR-M-3512

C H AN GIN G
LOCK ER S &

-0
FE MA LE

BD1 GF1
A B LU TION
-5
BD1 GF1
MA LE

-4
BD1 GF1
D I S WC

GF9

BD1 GF8
-

-
E N T. FEMA LE

S TOR

D I S WC

S E CU RI TY /
E N T. MALE

-1

BD1 GF4
-

C OMMAN D
BD1 GF2

-4

-0

GF2
LI FT

-
BD1 GF7

BD1 GF2
WC

WC

FI R E
C L.

BD1

BD1
QSS2/PR1/00/VRF/X/PR1-01

C ORR I DOR
GF6
-
BD1

250
O

O
000°
90.
000°
90.

FI BR E E N TR Y

FI BR E E N TR Y
-2
BD1 GF3

-9
BD1 GF2
B

A
-7
BD1 GF2
I1hr
-2

S TOR E
BD1 GF2
MMR B

-5

-8
BD1 GF2

-6

BD1 GF2
BD1 GF2

MMR A
S TA IR -2
R oom
-3
GOOGLE
S TOR E
BD1 GF2
LOAD I NG BA Y
-1
BD1 GF3
BOU : 3379

N
C ORR I DOR
-0
BD1 GF3
24775

FM S TO R E
-7
BD1 GF5

TX ROOM
-6

-4
BD1 GF5

BD1 GF4
TX ROOM
-6
ST

BD1 GF4

-5
TX ROOM
BD1 GF4
-7
M

M
TX ROOM
BD1 GF4
2950

-3
LV P AL N T
150 mm x 100 mm DX

BD1 GF4
R OOM

-2
LV P AL N T

BD1 GF4
R OOM
LV P AL N T

LV P AL N T
-8

-9
R OOM

R OOM
BD1 GF4

BD1 GF4
FM S TO R E
-5
BD1 GF5
L

L
C R A H R OOM
-4
S TA IR -3
BD1 GF5

-5
BD1 GF3

D A TA HA LL-2
C R A H R OOM
-6
BD1 GF3

-7
BD1 GF3
C R A H R OOM
-3

D A TA HA LL-1
BD1 GF3

C R A H R OOM
-4
BD1 GF3

-8
BD1 GF3
C ORR I DOR
-0
S ER VI CE

BD1 GF4
C ORR I DOR
-2
BD1 GF5

C ORR I DOR
-1
BD1 GF4
BOT : 3351

K
M'

S U PR ES SI ON

-1
BD1 GF5
B OTTLE
S TOR E
GAS

ME CH AN I CA L
P LA NT ROOM
-0
BD1 GF5
2950

825

J
1060

1805

I
ø9.5mm X ø15.9mm

111219

111219
1770

100878
H

H
FROM QSS2/EX/XX/ACCU/X/PR1-03

G
QSS2/PR1/00/FCU/X/PR1-09 985 1220

-9
BD1 GF3
R oom
F

F
BOU : 3011

E
405 765 QSS2/PR1/00/FCU/X/PR1-10
300 mm x 100 mm DX

435

D
BOU : 3445
M FA QSS2/PR1/00/CRAH/X/PR1-01

C
275
300 mm x 100 mm DX BOU : 510

1170

B
00 °

A
.0
90
250

BOT : 3351

N 290 4198. 25 m
E 39900 8. 76 m
59027

MECHANICAL
ø9.5mm X ø15.9mm 465 PLANT ROOM

4
1

6
FROM QSS2/EX/XX/ACCU/X/PR1-04 GF-40

2575
STAIR
ø9.5mm X ø15.9mm GF-50
FROM QSS2/EX/XX/ACCU/X/PR1-03

For continuation refer to sheet no: QSS2-JEG-CW-00-DR-M-3503.


QSS2/PR1/00/CRAH/X/PR1-02
FM STORE
BOU : 510
QSS2/PR1/00/VRF/X/PR1-02 GF-51

885
BOU : 3400 180

150 mm x 100 mm DX
300
Notes
BOT : 3351 SHEET NOTES:

2705
ø9.5mm X ø15.9mm
FROM QSS2/EX/XX/ACCU/X/PR1-04 CORRIDOR
GF-49 1. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS(mm) UNLESS
700

740
NOTED OTHERWISE.

QSS2/PR1/00/FCU/X/PR1-06 2. REFRIGERANT TRAY/TRUNKING SIZES (WxH) INDICATED IN


MILLIMETERS (mm)
BOU : 2977 LV PLANT ROOM
TX ROOM
GF-41 3. REFRIGERANT TRAY/TRUNKING ELEVATION INDICATED IN
GF-48 MILLIMETERS (mm) FROM LEVEL 00 TO BOTTOM OF TRAY.
L (BOT)

4. ALL PIPE SIZES INSIDE TRAY ARE SHOWN IN MM

QSS2/PR1/00/FCU/X/PR1-02
SERVICE
QSS2/PR1/00/EAF/X/PR1-01 BOU : 2938 875 CORRIDOR
BOU : 3350 2280

550
GF-36

K'

265

970
505
LV PLANT ROOM CYLINDER REFRIGERATION LEGEND
QSS2/PR1/00/FCU/X/PR1-07 GF-42 STORE
GF-38 SYSTEM
TX ROOM BOU : 3135
GF-47 REFRIGERANT CONTAINMENT (TRAY/TRUNKING)

MECHANICAL EQUIPMENT - VENTILATION


QSS2/PR1/00/FCU/X/PR1-03
QSS2/PR1/00/EAF/X/PR1-02 2280
BOU : 2938 875
BOU : 3446

430
ABBREVIATIONS
CORRIDOR

265
GF-37
C01 Issued for Approval QST 17.12. 2022
LV PLANT ROOM BOT BOTTOM OF TRAY
GF-43
BOU BOTTOM OF UNIT Rev Description Issued to Date
K TX ROOM
FA FROM ABOVE
GF-46 Revision Schedule

2300
TB TO BELOW
2280
QSS2/PR1/00/FCU/X/PR1-04
QSS2/PR1/00/EAF/X/PR1-03 BOU : 2938 875
505
IV ISOLATION VALVE
BOU : 3446 Employer:

515
QSS2/PR1/00/FCU/X/PR1-08 SV SOLENOID VALVE
BOU : 3068
TXV THERMOSTATIC EXPANSION VALVE
265

FIRE
SUPPRESSION
ROOM 1010
LV PLANT ROOM GF-39
TX ROOM
GF-44
QSS2/PR1/00/FCU/X/PR1-11
GF-45 BOU : 3475
835 TRAY DETAIL SCHEDULE
QSS2/PR1/00/FCU/X/PR1-05 Site:
BOU : 2905 875
HOT DIP GALVANIZED
2280

1625
QSS2/PR1/00/EAF/X/PR1-04

1075
BOU : 3447

990
S. No. Width (mm) Thickness(mm) Support Spam (m)
J'
360

1 100 To 300 1.5 2.0


1 450 To 900 2.0 2.0
J QSS2/PR1/00/FCU/X/PR1-01
Design Consultant:
BOU : 3040
REFRIGERATION PIPE INSULATION SCHEDULE
REFRIGERANT
S. No. Service Type of Insulation Thickness St Pauls Place, 40 St Pauls Square,Birmingham T. +44(0)121 314 6618
COPPER PIPE B3 1FQ, United Kingdom F. +44(0) 121 233 2716
1 Refrigeration Pipes Copper Closed cell nitrile rubber 19
MEP Consultant:

00 Ground Floor - Refrigerant Services Layout - Zone 4


1 1 : 100
BSE 3D Ltd
T. +44 207 193 7146
231 Vauxhall Bridge Road
SW1V 1EH London

Engineer of Record:

M M' Office BC-29


European Business Centre,
Dubai Investments Park,
ø9.5mm X ø15.9mm Dubai Tel: +971 45674929
FROM QSS2/EX/XX/ACCU/A/PR1-03
ø9.5mm X ø15.9mm MEP Contractor:
FROM QSS2/EX/XX/ACCU/A/PR1-04

QSS2/PR1/00/VRF/X/PR1-02
QSS2/PR1/00/VRF/X/PR1-01
F.F. Construction Plan00
5650

Akaria Center 2, 4th Floor,


1060 Office No. 425, Main Olaya Street Tel: +966 112150528
885 P.O. Box 18657 Email: info@joneseng.com
150 mm x 100 mm DX Website: www.joneseng.com
Riyadh 11423
BOT : 3351 Kingdom of Saudi Arabia

Project:
150 mm x 100 mm DX QUANTUM SWITCH TAMASUK DC 2
BOT : 3351 DAMMAM 2nd INDUSTRIAL CITY
DAMMAM KSA
3400

3380
Drawing Title:

Mechanical Services
Refrigerant Services Layout
G.F. Construction Plan Ground Floor - Sheet 4 of 8
1000

Drawing By: Checked By: Approved By: Scale @A1:


As
SECTION A-A JEG S.M S.Y
indicated
Ground Floor - Refrigerant Services - Z4 3 1 : 50
2 Drawing Reference: CDE Status: CDE Rev:

QSS2-JEG-CW-00-DR-M-3512 D4 C01
Do Not Scale - Use Figured Dimensions Only
Printed: 17/12/2022 16:50:14