Académique Documents
Professionnel Documents
Culture Documents
Keyplan
6
2C
4C
1A
1B
2A
2B
4B
4A
P
P
C H AN GIN G
LOCK ER S &
-1
FI R ST AI D
BD1 GF1
BD1 GF7
R OOM
-
MA LE
I N TER V EI W
-9
MA LE WC /
S H OWE R
BD1 GF1
GF3
R OOM
-
MA EL PR A YE R
-6
BD1
R OOM
BD1 GF1
R E C EP TIO N
GF1
-
C ONFER A NC E
-3
C A NTEE N
BD1 GF1
-2
BD1 GF1
R OOM
BD1
GF5
S TA RI -1
-
S H OWE R FS FCA S D
FE MALE WC /
BD1
-7
10591
BD1 GF1
C H AN GIN G
LOCK ER S &
-0
FE MA LE
BD1 GF1
A B LU TION
-5
BD1 GF1
MA LE
-4
BD1 GF1
D I S WC
GF9
BD1 GF8
-
-
E N T. FEMA LE
S TOR
D I S WC
S E CU RI TY /
E N T. MALE
-1
BD1 GF4
-
C OMMAN D
BD1 GF2
-4
-0
GF2
LI FT
-
BD1 GF7
BD1 GF2
WC
WC
FI R E
C L.
BD1
BD1
C ORR I DOR
GF6
-
BD1
250
O
O
000°
90.
000°
90.
FI BR E E N TR Y
FI BR E E N TR Y
-2
BD1 GF3
-9
BD1 GF2
B
A
-7
BD1 GF2
I1hr
-2
S TOR E
BD1 GF2
MMR B
-5
-8
BD1 GF2
-6
BD1 GF2
BD1 GF2
MMR A
S TA IR -2
R oom
-3
GOOGLE
S TOR E
BD1 GF2
LOAD I NG BA Y
-1
BD1 GF3
N
N
C ORR I DOR
-0
BD1 GF3
24775
QSS2/DH2/00/PRD/A/DH2-02
FM S TO R E
-7
BD1 GF5
TX ROOM
-6
-4
BD1 GF5
BD1 GF4
TX ROOM
QSS2/DH1/00/PRD/A/DH1-02
-6
ST
BD1 GF4
-5
TX ROOM
BD1 GF4
-7
M
M
TX ROOM
BD1 GF4
2950
-3
LV P AL N T
BD1 GF4
R OOM
-2
LV P AL N T
BD1 GF4
R OOM
LV P AL N T
LV P AL N T
-8
-9
R OOM
R OOM
BD1 GF4
BD1 GF4
FM S TO R E
-5
BD1 GF5
L
L
C R A H R OOM
-4
S TA IR -3
BD1 GF5
-5
BD1 GF3
D A TA HA LL-2
C R A H R OOM
-6
BD1 GF3
-7
BD1 GF3
C R A H R OOM
-3
D A TA HA LL-1
BD1 GF3
C R A H R OOM
-4
BD1 GF3
-8
BD1 GF3
C ORR I DOR
-0
S ER VI CE
BD1 GF4
C ORR I DOR
-2
BD1 GF5
C ORR I DOR
-1
BD1 GF4
K
K
S U PR ES SI ON
-1
BD1 GF5
B OTTLE
S TOR E
GAS
ME CH AN I CA L
P LA NT ROOM
-0
BD1 GF5
2950
J
I
I
111219
111219
2060
100878
H
H
M'
G
300x300 FAI FA
FAI 300x300
-9
BD1 GF3
R oom
F
F
3945
A
BOD : 317 mm
E
300x250 EXH TA
D
659
EXH 300x250
C
BOD : 2075 mm
B
SA 160ø
00 °
A
.0
90
1800
250
N 290 4198. 25 m
E 39900 8. 76 m
59027
4
1
6
SA 160ø
BOD : 5230 mm
QSS2/DH1/00/AHU/A/DH1-01
4910
EXH 300x250
EXH 250x300 Notes
BOD : 2744 mm
BOD : 2075 mm
TA Notes:
285 SA 160ø
SA 160ø BOD : 5230 mm 1. All dimensions are in mm.
QSS2/DH1/00/VCD/X/DH1-007 RA 300x250 300x250 EXH TA SA 160ø QSS2/DH2/00/VCD/X/DH2-005 2. All bell mouth in supply/return duct are covered by wire
SA 300x300 mesh.
BOD : 5160 mm BOD : 1020 mm
SA 300x300 3. Access doors are provided with all fire dampers
RA 300x250 SA 200ø 4. All VCD's are locate as easily accessible & and close to
BOD : 4960 mm
BOD : 1425 mm
2865
QSS2/DH1/00/VCD/X/DH1-002 UP BOD : 5210 mm end user
SA 200ø AD SA 300x300 5. Coordinate with civil contractor for connection between
BOD : 5210 mm B BOD : 5160 mm duct and louver.
QSS2/DH2/00/FDA/X/DH2-02 QSS2/DH2/00/VCD/X/DH2-008
473
A
L AD
QSS2/DH1/00/VCD/X/DH1-003 AD
QSS1/DH1/00/FDA/X/DH1-01
UP SA 300x300
SA 250ø QSS2/DH1/00/FDA/X/DH1-02 QSS2/DH2/00/VCD/X/DH2-007
BOD : 4960 mm
BOD : 5185 mm
QSS2/DH1/00/VCD/X/DH1-004 QSS2/DH1/00/PRD/A/DH1-03 QSS2/DH2/00/FDA/X/DH2-01 SA 160ø QSS2/DH2/00/VCD/X/DH2-002
K' SA 160ø AD
RA 300x250
QSS2/DH1/00/PRD/A/DH1-04 3779 2824 BOD : 1020 mm RA 300x250
QSS2/DH2/00/PRD/A/DH2-04 BOD : 1425 mm
SA 200ø
BOD : 5210 mm QSS2/DH1/00/VCD/X/DH1-001
5390
520
520
5650
C01 Issued for Approval QST 07.12. 2022
SA 200ø
QSS2/DH2/00/AHU/A/DH2-01
QSS2/DH2/00/VCD/X/DH2-001 BOD : 5210 mm
2868
2868
Rev Description Issued to Date
QSS2/DH1/00/VCD/X/DH1-005 SA 160ø QSS2/DH2/00/VCD/X/DH2-003 Revision Schedule
SA 160ø 1450
K
SA 160ø
B
QSS2/DH1/00/VCD/X/DH1-006 QSS2/DH2/00/VCD/X/DH2-004 Site:
SA 160ø
FAI 300x300
659
BOD : 317 mm
3770
QSS2/DH1/00/PRD/A/DH1-01
J
300x300 FAI FA St Pauls Place, 40 St Pauls Square,Birmingham T. +44(0)121 314 6618
B3 1FQ, United Kingdom F. +44(0) 121 233 2716
QSS2/DH2/00/PRD/A/DH2-01
MEP Consultant:
M8 3000
1370
995