DESIGN OF

N OF FLOOR
Fcu kg/cm2
2
250
pu=0.35Ac*
Fy kg/cm2 3600
Dimater of bars mm 16
joint REACTION pu Ac b t As1
n of colm ton T cm2 cm cm cm2
6 36.296 79.8512 715.384 30 30 9
9 36.2374 79.72228 714.229 30 30 9
10 29.5417 64.99174 582.259 30 30 9
13 34.4979 75.89538 679.944 30 30 9
16 37.911 83.4042 747.216 30 30 9
19 38.2758 84.20676 754.406 30 30 9
20 19.4473 42.78406 383.301 30 30 9
21 31.015 68.233 611.297 30 30 9
22 27.7053 60.95166 546.064 30 30 9
23 19.8494 43.66868 391.226 30 30 9
24 40.2881 88.63382 794.068 30 30 9
25 42.2965 93.0523 833.653 30 30 9
c1 14.4648 31.82256 285.097 30 30 9
c2 34.0734 74.96148 671.577 30 30 9
c3 23.7508 52.25176 468.122 30 30 9
c4 34.0197 74.84334 670.519 30 30 9
c5 14.4623 31.81706 285.048 30 30 9
11 53.1007 116.82154 1046.6 30 40 12
12 53.0595 116.7309 1045.79 30 40 12
14 54.0923 119.00306 1066.14 30 40 12
15 54.1398 119.10756 1067.08 30 40 12
17 70.7737 155.70214 1394.93 30 50 15
18 74.3611 163.59442 1465.64 30 50 15
c6 73.0351 160.67722 1439.5 30 50 15
c7 72.9646 160.52212 1438.11 30 50 15
SIGN OF COLMN ULT

0.35Ac*Fcu+0.67*Fy*As

N of bar
‫النموذج‬
6
6
6
6
6
30*30 ( 6/16)

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6 30*40(6/16)
8
8
8
8 30*50(8/16)