Vous êtes sur la page 1sur 1

0 REV:

A B C D A B C D
E-00
LÁMINA

2010 20099

2
127
150 670 670 670 6700 6700 6700 45° 6
CF-8 x 2 34" C.14
8.5
CM-1 CF 8"x24"" C.14 CM-1 CF 8"x24"" C.14 CM-1 CF 8"x24"" C.14 CM-1
1 150 180 180 150 1 1 1
25 250
CF 8"x24"" C.14 CF 8"x24"" C.14 CF 8"x24"" C.14

125 CM-1 1254


CM-1 CM-1 150
CM-1 8
PB-1 180 180 PB-1
PB-1 PB-1 CF 8"x24"" C.14 CF 8"x24"" C.14 CF 8"x24"" C.14
DA-1 DA-1 45° 6
DA-1 DA-1
Z-1

PENDIENTE 33.39%
Z-1 ATIEZADOR
Z-2 Z-2 349
t=21" (A-36) 5.8
125 1254

CF 8"x24"" C.14 CF 8"x24"" C.14 CF 8"x24"" C.14 IPR 14"x 32.70kg/ml

IPR 14"x32.70kg/ml
IPR 14"x32.70kg/ml

IPR 14"x32.70kg/ml
IPR 14"x32.70kg/ml
652 652 6518 6518
125 1254
COLUMNA METÁLICA
RD CM-1
CF 8"x24"" C.14 CF 8"x24"" C.14 CF 8"x24"" C.14 O.
LIS
O
Ø=
RD 3

A-
36 O. - 36
RD -3
6 4"
A- DETALLE DE CONEXION VIGA - COLUMNA
125 1254 3 " LIS "A O. 3 "A 36
ESC: 1:20 [mm]

3
O 4
Ø= Ø= Ø= VIGA 14x22

4
Ø= LIS
O CF 8"x24"" C.14 SO CF 8"x24"" C.14 O SO CF 8"x24"" C.14
LIS "A L I Ø= L I

3
O. O. O. (IR 14" x 32.9 kg/m)

4
-3 3
"A
RD 6 RD RD ESC 1:5 [mm]

4
-3
6
110 1104

CF 8"x24"" C.14 CF 8"x24"" C.14 CF 8"x24"" C.14


1304 30 1304 13035 300 13035

CF 8"x24"" C.14 CF 8"x24"" C.14 CF 8"x24"" C.14


110 1104
6
RD RD -3 RD 1
O. 36 O. "A O

3
LIS " A- LIS Ø=
4 .L
CF 8"x24"" C.14 CF 8"x24"" C.14 IS CF 8"x24"" C.14

3
O 4 O O O 6 45°
Ø= Ø= Ø= L IS Ø=
I SO O. 3 CF-8 x 2 34" C.14
"A .L "A RD
4"
36

3
125 1254 A- - 19

4
-3 O -3 36 3 "A
6 RD 6 4
CF 8"x24"" C.14 CF 8"x24"" C.14 CF 8"x24"" C.14 Ø=
O
IS

IPR 14"x32.70kg/ml

IPR 14"x32.70kg/ml
IPR 14"x32.70kg/ml

IPR 14"x32.70kg/ml
O.L
RD 152
125 1254
652 652 6518 6518
8

PENDIENTE 33.39%
CF 8"x24"" C.14 CF 8"x24"" C.14 CF 8"x24"" C.14 6 45°
ATIEZADOR
125 1254 t=21" (A-36) 64

CM-1 CM-1 CM-1


CM-1
CF 8" x 2 3/4" C.14
PB-1 PB-1 PB-1 IPR 14"x 32.70kg/ml ESC 1:5 [mm]
PB-1
DA-1 DA-1 DA-1 CF 8"x24"" C.14 CF 8"x24"" C.14 CF 8"x24"" C.14
150 DA-1 150
Z-1 Z-2 Z-2
125 Z-1 1254
COLUMNA METÁLICA
CF 8"x24"" C.14 CF 8"x24"" C.14 CF 8"x24"" C.14 CM-1
25 250
2 150 180 180 150 2 2 2
CM-1 CF 8"x24"" C.14 CM-1 CF 8"x24"" C.14 CM-1 CF 8"x24"" C.14 CM-1 407
DETALLE DE CONEXION VIGA - COLUMNA
ESC: 1:20 [mm]
670 670 670 6700 6700 6700
180 180

2010 20099

406

A B C D A B C D

PLANTA DE CIMENTACION PLANTA DE CUBIERTA


ESC. 1:75 [cm] ESC: 1:75 [mm]

COLUMNA METÁLICA CM-1


(PTR 8"x8"x 5/16" t=7.925 mm)
ESC 1:5 [mm]
TABLA DE ZAPATAS AISLADAS
CAPACIDAD DE CARGA DEL TERRENO PROFUNDIDAD MÍN DE DESPLANTE
10.0 Ton/m² 1.50 m
DIMENSIÓN ARMADO LECHO INF. ARMADO LECHO SUP.
TIPO H OBSERVACIONES
A B ASA ASB ASA ASB
Z-1 150 150 20 1 # 4 @ 20.00 1 # 4 @ 20.00 1 # 4 @ 20.00 1 # 4 @ 20.00 CENTRAL
Z-2 180 180 25 1 # 5 @ 20.00 1 # 5 @ 20.00 1 # 5 @ 20.00 1 # 5 @ 20.00 CENTRAL
N.P.T. TUERCA HEXAGONAL 2H Y RONDANA DE PRESIÓN
*LOS ELEMENTOS EN CONTACTO CON EL TERRENO LLEVARÁN UN RECUBRIMIENTO DE 5 cm. LIBRES
COLUMNA METÁLICA 50
PLACA BASE
150 ***LIKANTOR INGENIERIA EN ESTRUCTURAS
100 REPRESENTADA POR FERNANDO A. ROBLEDO
TORRES EXPRESAMENTE SE RESERVA LA LEY
GROUT (CONSTRUCTION
GENERAL DE DERECHOS DE AUTOR Y DEMÁS DE
CARTABONES GROUT-DEGUSA O SIMILAR) SER REPRODUCIDOS, MODIFICADOS O COPIADOS
1 2 COLUMNA DE ACERO A
PLACA BASE PB-# R
POR CUALQUIER MÉTODO NI DEBERÁN SER
8 TUERCA PARA NIVELAR EN ANCLAS INGENIERÍA EN ESTRUCTURAS. ASIGNADOS A UNA TERCERA PERSONA SIN
13035 45°
ASB
DADO DA-1
DE ESQUINA Y DONDE SE REQUIERA Av. Chapultepec #104 4to. Piso OBTENER AUTORIZACIÓN POR ESCRITO DE
PLACA BASE PARA MONTAJE FERNANDO A. ROBLEDO TORRES. LOS PLANOS NO
6518 6518 Col. Americana Guadalajara, FIRMADOS POR EL SUSCRITO, NO ESTAN
N.T.N.
8 ANCLAS Ø 3/4" ASA
750 Jalisco TEL. (33) 1371 2442 AUTORIZADOS PARA SU CONSTRUCCION.
250 1254 1254 1254 1254 1104 300 1103 1254 1254 1254 1254 250 ZAPATA Z-# likantor@lk2w.mx
B
5 5 20 ANCLA REDONDO LISO Ø= 3 4" No. REVISIÓN FECHA
SUELO-CEMENTO 1:10
h ACERO A-36 (ROSCADA)

VAR
VAR
MULTYPANEL 150
t=1.5" ZAPATA

D:\Dropbox\LIKANTOR 2022\3.-ING. MANUEL ISLAS\10.-CUBIERTA METALICA RANCHO\2.-EST\P_XXX.dwg


NIVEL DE DESPLANTE 5
MULTYPANEL DE ZAPATAS (NDZ)
t=1.5" 50
H N.D.Z.
ISOMÉTRICO CONEXIÓN ZAPATAS A COLUMNA METÁLICA PL 1/2" x 75 X 75 DEPARTAMENTO DE DIBUJO
5 ESC: S/E [cm]
IPR 14"x32.70kg/ml
DIBUJÓ: REVISÓ:
ING. DEA LAURA DONAJI ANGEL ING. ZAID EZEQUIEL AGUILLON
IPR 14"x32.70kg/ml TORNILLOS TORNILLOS GONZALEZ. MORALES.
2 Ø 3/8" A307 2 Ø 3/8" A307
PLANTILLA DE CONCRETO DETALLE DE COLOCACIÓN DEPARTAMENTO DE CÁLCULO
f'c=100 kg/cm² DE ANCLAS PARA PLACA BASE CALCULÓ: APROBÓ:
CF 8"x24"" C.14 CF 8"x24"" C.14 ESC: S/E ING. LUIS ANGEL CAMPA ING. FERNANDO ANTONIO
ESTRATO RESISTENTE DE ACUERDO AL 3 3
CAPAS DE 30 30 ARRIOLA. ROBLEDO TORRES.
ESTUDIODE MECÁNICA DE SUELOS.
SUELO-CEMENTO 120 120 UBICACIÓN
CAPACIDAD DE CARGA s = 10.00 Ton/m² CALLE X COLONIA X, CP X, GUADALAJARA, JALISCO, MÉXICO.

APS 1"x1/8" APS 1"x1/8" APS 1"x1/8"


PROPIETARIO/CLIENTE
ING. ***.
APS 2"x1/8"x120 APS 2"x1/8"x120
ZAPATA - SECCIÓN VERTICAL (CM) (TOTAL=2) (TOTAL=2)
ESC: S/E [cm] PROYECTO
"***"
POLÍN MONTEN POLÍN MONTEN
CONTENIDO

DETALLE DE CONTRAFLAMBEO EN LA CUBIERTA NOTAS GENERALES.


ESC 1:10 [mm] BARRENO DE 1"
(PARA CONTRAN) COTAS NIVELES ESCALA PROYECTO
CONECTOR 3 8" INDICADA METROS INDICADA P-2100X

6 TORNILLO FECHA REVISIÓN LÁMINA


6 6 GUADALAJARA, JALISCO
250 504
PL 12" 1" x 3" A-325
A XX DE XXXXX DE 2021 00 E-00
6 PL 12" 6 PL 12"
REDES SOCIALES ABREVIATURAS
6 CA CABEZAL
TORNILLO 250
170 160 250 K CASTILLO
1" x 3" A-325
KT CASTILLO TENSOR
250 250 C COLUMNA CONCRETO
CM COLUMNA METÁLICA
CT CONTRA-TRABE
CM-1 CM-1 80 90 ISOMÉTRICO DA DADO
CRUCETA CRUCETA ESC 1:10 [mm] DL DALA
CRUCETA REDONDO LISO REDONDO LISO MC MURO DE CONCRETO
REDONDO LISO MCT MURO DE CONTENCIÓN
6 TUERCA 3 4" M MURO DE MAMPOSTERÍA
6 6 MR MURO REFORZADO
ROSCADA
MT MURO TAPÓN
CONECTOR 3 8" NK NACE CASTILLO
RODEO NKT NACE CASTILLO TENSOR
NC NACE COLUMNA CONCRETO
LIKANTOR NCM NACE COLUMNA METÁLICA
TORNILLO NM NACE MURO
TORNILLO TORNILLO NMC NACE MURO DE CONCRETO
1" x 3" A-325 N NERVADURA
1" x 3" A-325 1" x 3" A-325
NB NERVADURA DE BORDE
ALZADOS EJE "A, B, C Y D" UN EXTREMO NL NERVADURA DE LIGA
ESC. 1:75 [mm] CRUCETA ESC 1:10 [mm] NS NERVAURA DE SÓTANO
CRUCETA TR TRABE
CRUCETA REDONDO LISO
REDONDO LISO TRS TRABE DE SÓTANO
REDONDO LISO
CONECTOR 3 8" Z ZAPATA
ZC ZAPATA CORRIDA
SIMBOLOGÍA
TUERCA Δ CONTRAFLECHA CASTILLO CORRIDO
SOLDADA @ A CADA NACE CASTILLO
6 6 # NÚMERO DALA
PLACA SENCILLA Ø DIÁMETRO NACE MURO
ESC 1:10 [mm] DE CONCRETO
PLACA DOBLE OTRO EXTREMO LIKANTOR INGENIERÍA EN
***LAS COTAS RIGEN AL DIBUJO, CUALQUIER
ESC 1:10 [mm] MEDIDA TOMADA CON ESCALIMETRO U OTRO
ESC 1:10 [mm] ESTRUCTURAS METODO. ES RESPONSABILIDAD DIRECTA DEL
CONSTRUCTOR.***