PARAMETRES DE DEVERSEMENT:

------------------------------------------------------------------------------------- ---------------------------------------------------
PARAMETRES DE FLAMBEMENT:

en y: en z:
----------------------------------------------------------------------------------------------------------------------------- -----------
FORMULES DE VERIFICATION:
SigN + kD*SigFy + SigFz = -0.69 + 1.00*10.59 + 38.81 = 48.71 < 235.00 MPa (3.731)
1.54*Tauy = 1.54*1.43 = 2.21 < 235.00 MPa (1.313)
1.54*Tauz = 1.54*1.55 = 2.38 < 235.00 MPa (1.313)
----------------------------------------------------------------------------------------------------------------------------------------
DEPLACEMENTS LIMITES

Flèches (REPERE LOCAL):


uy = 0.0 cm < uy max = L/200.00 = 1.2 cm Vérifié
Cas de charge décisif: 15 DEP /11/ 1*1.00 + 2*1.00 + 3*1.00 + 4*1.00 + 5*1.00 + 6*1.00 + 8*1.00
uz = 0.0 cm < uz max = L/200.00 = 1.2 cm Vérifié
Cas de charge décisif: 15 DEP /11/ 1*1.00 + 2*1.00 + 3*1.00 + 4*1.00 + 5*1.00 + 6*1.00 + 8*1.00

Déplacements (REPERE GLOBAL): Non analysé


----------------------------------------------------------------------------------------------------------------------------------------
Profil correct !!!

CALCUL DES STRUCTURES ACIER


----------------------------------------------------------------------------------------------------------------------------- -----------
NORME: CM66
TYPE D'ANALYSE: Vérification des pièces
----------------------------------------------------------------------------------------------------------------------------------------
FAMILLE:
PIECE: 6 POINT: 3 COORDONNEE: x = 1.00 L = 1.29 m
----------------------------------------------------------------------------------------------------------------------------- -----------
CHARGEMENTS:
Cas de charge décisif: 12 EFF /20/ 1*1.33 + 2*1.33 + 3*1.33 + 4*1.33 + 5*1.42 + 6*1.42 + 8*1.42
------------------------------------------------------------------------------------------------------------------------------------ ----
MATERIAU:
ACIER E24 fy = 235.00 MPa
------------------------------------------------------------------------------------ ----------------------------------------------------

PARAMETRES DE LA SECTION: HEA 180


ht=17.1 cm
bf=18.0 cm Ay=34.20 cm2 Az=10.26 cm2 Ax=45.25 cm2
ea=0.6 cm Iy=2510.29 cm4 Iz=924.61 cm4 Ix=14.86 cm4
es=0.9 cm Wely=293.60 cm3 Welz=102.73 cm3
----------------------------------------------------------------------------------------------------------------------------- -----------
CONTRAINTES: SigN = 121.95/45.25 = 0.26 MPa
SigFy = 64.60/293.60 = 2.16 MPa
SigFz = 94.26/102.73 = 9.00 MPa
----------------------------------------------------------------------------------------------------------------------------- -----------

PARAMETRES DE DEVERSEMENT:
z=1.00 B=1.00 D=1.07 Sig D=177.77 MPa
lD_inf=1.29 m C=2.92 kD=1.00
--------------------------------------------------------------------------------------------------------------------------------- -------
PARAMETRES DE FLAMBEMENT:

en y: en z:
----------------------------------------------------------------------------------------------------------------------------- -----------
FORMULES DE VERIFICATION: