Vous êtes sur la page 1sur 6

BUREAU D'ETUDE:PROTHESE D'EPAULE

Rendu Bibliographique: Tests mcanique sur la


prothse de l'paule

Prpar par : Encadr par:

MAAZAZ Zakariae AMADOU DIOP

GIM ED 4
Les diffrentes combinaisons tudi :
Combinaison1

Prothesis + scapula+mechanical testing


Iannotti, 2013
Kraljevi, 2011
kalouche ,2010
Roche,2006
lacroix,1997
Geraldes,2017
Diop,2006

Combinaison 2

Prosthesis+Shoulder+stress
Denard ,2017
Geraldes,2017
Lewicki, 2016
Zhang,2014
Schmidutz,2014
Dabirrahmani,2014
yang,2013

Combinaison 3

prosthesis+glnoid+loasening +mechanical load


Geraldes, 2017
Roche,2015
Roche ,2006
Anglin,2000
Lacroix,1997
Lewis ,2016
Patel ,2014

Combinaison 4

Arthroplasty+scapula+mechanical testing
Kalouche 2010
Lacroix ,1997
lannoti ,2013
Geraldes 2017

Combinaison 5

Prosthesis+glnoid+mechanical testing
Chae ,2015
Cioffi,2010
Kirane ,2017
Anglin,2000

Combinaison 6

Prosthesis+glenoid+failure+mechanical loading

Chevalier,2016
Lewis,2016
Roche,2013
Barber,2008
Liste Complte des articles

1. Geraldes, D.M., Hansen, U., Amis, A.A Parametric analysis of glenoid implant design
and fixation type (2017) Journal of Orthopaedic Research, 35 (4), pp. 775-784.

2. Iannotti, J.P., Lappin, K.E., Klotz, C.L., Reber, E.W., Swope, S.W.
Liftoff resistance of augmented glenoid components during cyclic fatigue loading in the
posterior-superior direction
2013) Journal of Shoulder and Elbow Surgery, 22 (11), pp. 1530-1536. Cited 29 times.

3. Kalouche, I., Crpin, J., Abdelmoumen, S., Mitton, D., Guillot, G., Gagey, O.
Mechanical properties of glenoid cancellous bone
(2010) Clinical Biomechanics, 25 (4), pp. 292-298. Cited 13 times.

4. Lacroix, D., Prendcrgast, P.J.


Stress analysis of glenoid component designs for shoulder arthroplasty
(1997) Proceedings of the Institution of Mechanical Engineers, Part H: Journal of
Engineering in Medicine, 211 (6), pp. 467-474. Cited 41 times.

5. Roche, C.P., Staunch, C., Hahn, W., Grey, S.G., Flurin, P.-H., Wright, T.W.,
Zuckerman, J.D.
Analysis of glenoid fixation with anatomic total shoulder arthroplasty in an extreme
cyclic loading scenario
(2015) Bulletin of the Hospital for Joint Diseases, 73, pp. S57-S62. Cited 1 time.

6. Barber, F.A., Coons, D.A., Ruiz-Suarez, M.


Cyclic Load Testing and Ultimate Failure Strength of Biodegradable Glenoid Anchors
(2008) Arthroscopy - Journal of Arthroscopic and Related Surgery, 24 (2), pp. 224-228.
Cited 35 times.

7. Roche, C., Angibaud, L., Flurin, P.H., Wright, T., Zuckerman, J.


Glenoid loosening in response to dynamic multi-axis eccentric loading: A comparison
between keeled and pegged designs with an equivalent radial mismatch
(2006) Bulletin: Hospital for Joint Diseases, 63 (3-4), pp. 88-92. Cited 10 times
8. Anglin, C., Wyss, U.P.,
Pichora, D.R.
Glenohumeral contact forces
(2000) Proceedings of the Institution of Mechanical Engineers, Part H: Journal of
Engineering in Medicine, 214 (6), pp. 637-644. Cited 59 times.

9. Anglin, C., Wyss, U.P., Pichora, D.R.


Mechanical testing of shoulder prostheses and recommendations for glenoid design
(2000) Journal of Shoulder and Elbow Surgery, 9 (4), art. no. 15673, pp. 323-331. Cited
100 times

10. Kraljevi, M., Zumstein, V., Wirz, D., Hgli, R., Mller-Gerbl, M.
Mineralisation and mechanical strength of the glenoid cavity subchondral bone plate
(2011) International Orthopaedics, 35 (12), pp. 1813-1819. Cited 8 times.

11. Diop, A., Maurel, N., Grimberg, J., Gagey, O.


Influence of glenohumeral mismatch on bone strains and implant displacements in
implanted glenods. An in vitro experimental study on cadaveric scapulae
(2006) Journal of Biomechanics, 39 (16), pp. 3026-3035. Cited 5 times.

12. Lewis, G.S., Brenza, J.B., Paul, E.M., Armstrong, A.D.


Construct damage and loosening around glenoid implants: A longitudinal micro-CT
study of five cadaver specimens
(2016) Journal of Orthopaedic Research, 34 (6), pp. 1053-1060. Cited 1 time.

13. Patel, R.J., Wright, T.M., Gao, Y.


Load transfer after cemented total shoulder arthroplasty
(2014) Journal of Shoulder and Elbow Surgery, 23 (10), pp. 1553-1562. Cited 6 times.

14. Zhang, J., Yongpravat, C., Kim, H.M., Levine, W.N., Bigliani, L.U., Gardner,
T.R., Ahmad, C.S.
Glenoid articular conformity affects stress distributions in total shoulder arthroplasty
(2013) Journal of Shoulder and Elbow Surgery, 22 (3), pp. 350-356. Cited 10 times.

15. Chae, S.W., Lee, J., Han, S.H., Kim, S.-Y.


Inferior tilt fixation of the glenoid component in reverse total shoulder arthroplasty: A
biomechanical study
(2015) Orthopaedics and Traumatology: Surgery and Research, 101 (4), pp. 421-425. Cited 2
times.
16. Kirane, Y.M., Lewis, G.S., Sharkey, N.A., Armstrong, A.D.
Mechanical characteristics of a novel posterior-step prosthesis for biconcave glenoid
defects
(2012) Journal of Shoulder and Elbow Surgery, 21 (1), pp. 105-115. Cited 23 times.

17. Cioffi, M., Necchi, S., Villa, T., Pennati, G.


Experimental evaluation of the testing conditions influence on shoulder prostheses
subluxation and edge displacement during astm f2028-05 testing
(2010) Journal of Mechanics in Medicine and Biology, 10 (2), pp. 341-352.

18. Chevalier, Y., Santos, I., Mller, P.E., Pietschmann, M.F.


Bone density and anisotropy affect periprosthetic cement and bone stresses after
anatomical glenoid replacement: A micro finite element analysis
(2016) Journal of Biomechanics, 49 (9), pp. 1724-1733. Cited 1 time.

19. Roche, C.P., Stroud, N.J., Martin, B.L., Steiler, C.A., Flurin, P.-H., Wright, T.W.,
DiPaola, M.J., Zuckerman, J.D.
The impact of scapular notching on reverse shoulder glenoid fixation
(2013) Journal of Shoulder and Elbow Surgery, 22 (7), pp. 963-970. Cited 17
times.

20. Barber, F.A., Coons, D.A., Ruiz-Suarez, Cyclic Load Testing and Ultimate
Failure Strength of Biodegradable Glenoid Anchors(2008) Arthroscopy - Journal