Vous êtes sur la page 1sur 1

1 2 3 4 5 6 7 8

cc

S11- Q1 F1 - V1
G1 NH00
A
S+ cc NH00/6A
g c

G1 P1
+ L- F2
L- - V2 Verbraucher
3 A LOAD
Q2 S LR 145 U<42V
NH00/6A CONSOMMATEUR
S12- 0-10A
c
2 2 cc CONSUMIDOR
G2 NH00 BV 15
F11 F3 - V3
S- B-
L a deregler
NH00/50A NH00/6A
CHARGING CONTROLLER B
REGULATEUR DE CHARGE s
REGULADOR DE CARGA
S13- Q3
L+
C o m u n i c a d o c o m o s e g r e d o e m p r e s a r i a l . R e s e rvados todos os direitos.

G3 NH00 S+ B+
(FPE)

U>56V U<45V g
F12
C o n f i e a t i t r e d e s e c r e t d 'e n t r e p r i s e . T o u s d r o i t s r e serves.
A l s B e t r i e b s g e h e i m n i s a n v e r t r a u t . A l l e R e c hte vorbehalten.
P r o p r i e t y d a t a , c o m p a n y c o n f i d e n t i a l . A l l r i g h t s reserved.

T4A
ST02 :T :T :3 :1 :6 :4 F 20
S14- Q4 K7 A2 -F Fremdeinspeisung
2k
EXTERNAL DC-POWER INPUT
G4 NH00 *) g NH00/63A
A1 P2 1 ALIMENTATION EXTERNE C
2 1 s
ALIMENTACION EXTERNA
3
6 A h-Zähler
Ah-COUNTER 60A gg
Ah-METRE 60mV
R4
8
Ah-METRO 4
12
K7 g
1 F9
11 -B1

NH00/63A Batterie 1 (24 Zellen) D


F10
-B2
cc

NH00/63A B a t t erie 2 (24 Zellen)

X1 :21 :22 :23 :61 (+)


BATTERY 24 CELLS
S o l a r mo d u l - G e s t e lle BATTERIE 24 ELEMENTS
SOLAR MODUL ARRAYS BATTERIA 24 CELDAS
MODULES SOLAIRES
BASTIDORES DE MODULOS SOLARES E i n b a u bei Bedarf * ) e n t fä l l t b e i A n s c h l u ß vo n R 1
U> U< (Ah<) TO BE OMITTED IF R1 IS INSTALLED
R1 INSTALLATION IF REQUIRED E
c ... H05V-K1,5 F ernsignalisierung INSERER SI NECESSAIRE SUPPRIMER SI R1 EST INSERE
REMOTE SIGNALLING SEGUN NECESSIDAD QUITAR SI R1 EXISTE CONTROL SOLAR 48V/3kW
cc . . . Cu 20x3
g . . . H05V-K16mm² SIGNAUX DE TELESURVEILLANCE
SENALIZACION REMOTA
COMMANDE SOLAIRE 48V/3kW
gg . .. H05V-K16mm² (gnge)
s . . . 1 , 2 3 mm2 ( 1mm2 )/Achtung! Ungesicherte Leitungen T y p : G 4 8 / 4 5 W B R U - F G 0 S O L 40 SOLAR CONTROL PANEL 48V/3kW
1 e n t fä l l t b e i E i n b a u vo n R 4
/CAUTION! LINES NON-FUSED
/ATTENTION! LIGNES SANS FUSIBLES TO BE OMITTED IF R4 IS INSTALLED 4 N 135/ P04/100 15.05.2001Sm / Vo Datum 22. 02.96

/ATENCION! CONEXIONES SIN FUSIBLES SUPPRIMER SI R4 EST INSERE 3/52 . . . . /P04/100 27.03.2001Sc h/ VoName P04 MW
QUITAR SI R4 EXISTE
Nicht gekennzeichnete Leitungen: 2 Z 201/ P04/ 100 19.07.2000BE/Vo Bereich ICN S O L A R S t e u e r u n g 48V/3kW
LINES NOT IDENTIFIED: 2 2 e n t fä l l t b e i L a s t a b s c h a l t ung 1 H 339/ P04/ 100 06. 04.99 MW Blatt
1mm
LIGNES NON DESIGNEES SONT: TO BE OMITTED IF LOAD DISCONN. IS USED Zust. Mitteilung Datum Name SIEMENS
HILOS NO ESPECIFICADOS SON: SUPPRIMER AVEC CHARGE DECONN. 1-
QUITAR SI CARGA DESC. A30050-X6005-X100-*-7511
K:\S_PS\WNSPS5\WSCAD\A30050\X6005\X100_3.001

Vous aimerez peut-être aussi