1' 1 2 3 4 4'

3650 15500

5000 5000 4000 1500

C2/F2 C2/F2
FTB
A'

FTB
2600

2600
B
FT
C1/F1 C1/F1 C1/F1 C1/F1

A FTB FTB FTB


C EXISTING

FTB

FTB

FTB

FTB
5000

C1/F1 C1/F1 C1/F1 C1/F1

B C1/F1
FTB C EXISTING
1350

FTB FTB FTB

B'
15000

5000

2300

FTB

FTB

FTB

FTB

FTB
C'
1350

FTB
C C1/F1
FTB FTB FTB
C EXISTING

C1/F1 C1/F1 C1/F1 C1/F1

FOUNDATION PLAN
5000

FTB

FTB

FTB

FTB
S
S C A L E : 1 : 1 0 0 MTS
0 100 200

FTB FTB FTB


D C EXISTING

C1/F1 C1/F1 C1/F1 C1/F1


1' 1 2 3 4 4'
3650 15500

5000 5000 4000 1500

C2 GB C2
A'

GB
2600

2600
GB
WF-1

A C1
GB
C1
GB
C1
GB
C1
WF-1 C EXISTING

WF-2

WF-2

WF-2

WF-2

EXISTING
GB
WF-1
WF-2
5000

GB

GB

GB
X'

WALL
WF-2 WF-2

WF-2

WF-2
WF-2

WF-2
C1 C1 C1 C1
B GB C EXISTING
1350

GB GB GB
C1

B' WF-1 WF-1 WF-1


15000

5000

2300

GB

GB

GB

GB

GB
C' WF-1 WF-1 WF-1 WF-1
1350

C1
GB
C C1 GB C1 GB C1 GB C1
C EXISTING

100MM THK CONCRETE


SLAB WITH 10MM REBAR
SPACED @ 0.40M O.C. B.W.

EXISTING
GROUND FLOOR FRAMING PLAN
5000

WF-1

GB

GB

GB

GB

WALL
S
S C A L E : 1 : 1 0 0 MTS
5500

0 100 200

C1 GB C1 GB C1 GB C1
D C EXISTING

WF-1
WF-1 WF-1 WF-1

Y'
1' 1 2 3 4 4'
3650 15500

5000 5000 4000 1500

C2 B2 C2
A' FIRE EXIT TO FIRE EXIT FROM S2
GROUND FLR. 3RD FLOOR

CB1

CB2
2600

2600
B2

B2

B2
B3

B3
DN
S3
A CB1
C1 B1 C1 B1 C1 B1 C1
4650
5000

X'
B3

B1

B1

B1

B1
S3

4650
S1 S1
S1

C1 C1 C1 C1

EXISTING BUILDING
B CB2
1350

B1 B1 B1
C1 B1

B'
15000

5000

2300

B1

B1

B1

B1

B1
S2
S1 S1
C' S1
1350

C1 B1

C CB2
C1 B1 C1 B1 C1 B1 C1

SECOND FLOOR FRAMING PLAN


5000

B1

B1

B1

B1
B3

S3 S
S C A L E : 1 : 1 0 0 MTS
S1 S1 0 100 200
S1

C1 B1 C1 B1 C1 B1 C1
D CB1
S3 S3 S3
B3

B3 B3 B3
CB1

CB1

CB1

CB2
Y'
1' 1 2 3 4 4'
3650 15500

5000 5000 4000 1500

C2 B2 C2
A' FIRE EXIT TO
FROM ROOF DECK
S2
2ND FLOOR

CB1

CB2
2600

2600
B2

B2

B2
B3

B3
DN
S3
A CB1
C1 B1 C1 B1 C1 B1 C1
5000

X' B3

B1

B1

B1

B1
S3
S1 S1
S1

C1 C1 C1 C1

EXISTING BUILDING
B CB2
1350

B1 B1 B1
C1

B' DN
15000

5000

2300

B1

B1

B1

B1

B1
S1 S1
C' S1
1350

C1

C C1 B1 C1 B1 C1 B1 C1

S3
THIRD FLOOR FRAMING PLAN
5000

B1

B1

B1

B1
S
S C A L E : 1 : 1 0 0 MTS
S1 S1 0 100 200
S1

C1 B1 C1 B1 C1 B1 C1
D PC1
S3 S3
S3
B3 B3
CB1
CB2

CB2
Y'
1' 1 2 3 4 4' 3 4 4'
3650 15500

5000 5000 4000 1500 4000 1500

RC1 B2 RC1 RB1


A' S2 S2

1350

1350
RB1
B2
CB1

CB2

RB1

RB1
S2
2600

2600

2600
B2

B2
B3 B2 RB1

B3

1250

1250
PC1 PC1 DN

A CB1
B1 B1 RC1 B1 RC2 RB1
5000

X' STAIR DECK FRAMING PLAN


B3

B1

B1

B1

B1
S
S C A L E : 1 : 1 0 0 MTS
0 100 200

B CB2 PC1
1350

PC1 B1 B1 B1
PC1 B2
PC1
B'
15000

5000

2300

B2

B1

B1

B1

B1
C'
PC1
1350

PC1 B2

C B1 B1 B1
PC1

ROOF DECK FRAMING PLAN


5000

B1

B1

B1

B1
S
S C A L E : 1 : 1 0 0 MTS
0 100 200

B1 B1 B1
D PC1 PC1 PC1 PC1
B3 B3
CB1
CB2

CB2

Y'
C1 C2

FFL (MUNICIPAL BLDG.) FFL (MUNICIPAL BLDG.)


500 1000

S.O.G. S.O.G.

600
FFL (EXIT STAIR)
FILL FILL S.O.G.
EXISTING EXISTING
NGL NGL
1100

1100
GRADE BEAM GRADE BEAM
(see details) (see details)
3000

FFL (ROAD LINE) FFL (ROAD LINE)

2600
1100

1100
FOOTING TIE BEAM FOOTING TIE BEAM
(see detail) (see detail)
400

400
100mm THK. GRAVEL 100mm THK. GRAVEL
BED ON WELL COMPACTED BED ON WELL COMPACTED
SUBGRADE (TYP.) SUBGRADE (TYP.)

12-20mm Ø BOTTOM BAR 10-20mm Ø BOTTOM BAR


BOTHWAYS BOTHWAYS

500 400
2000

1500

400
500

8 - 20mm Ø MAIN BAR 4 - 20mm Ø MAIN BAR


w/ 2 - 10mm Ties spaced @ 4 - 16mm Ø MAIN BAR
8 @ 0.10m, & rest @ 0.15m w/ 10mm Ties spaced @
O.C. 8 @ 0.10m, & rest @ 0.15m O.C.

1500

2000
F2
F1
S FOOTING TIE BEAM DETAIL SIZES R E I N F O R C E M E N T S
DEPTH
S C A L E :
0
1 : 1 0 0
100
MTS
200
MARK LENGTH WIDTH THICKNESS

F1 2.00 2.00 0.40 3.00 12-20mm Ø BOTTOM BAR, BOTHWAYS


F2 1.50 1.50 0.40 2.60 10-20mm Ø BOTTOM BAR, BOTHWAYS
L4 TOP OF ROOF BEAM ROOF DECK

500

500
4-10mm Ø @
100mm O.C.

BOTTOM OF ROOF BEAM


6-10mm Ø @
100mm O.C.

580
4000

2340

3500
15-10mm Ø @
150mm O.C.

580
6-10mm Ø @
100mm O.C.

8 - 20mm Ø MAIN BAR 4 - 20mm Ø MAIN BAR L3 3RD FLR. FINISHED LINE

500

500
w/ 2 - 10mm Ties 4 - 16mm Ø MAIN BAR 5-10mm Ø @
w/ 10mm Ties spaced 100mm O.C.
spaced @
8 @ 0.10m, & rest @ @
8 @ 0.10m, & rest @ BOTTOM OF ROOF BEAM
0.15m O.C. 6-10mm Ø @
0.15m O.C. 100mm O.C.

650
SPLICE

580
4000

2340

3500
17-10mm Ø @

13000
150mm O.C.

580
6-10mm Ø @
100mm O.C.

L2 2ND FLR. FINISHED LINE

500

500
5-10mm Ø @
100mm O.C.

BOTTOM OF BEAM

750
8-10mm Ø @
100mm O.C.

4400

650
SPLICE

3000

4500
24-10mm Ø @
150mm O.C.

L1 FINISH FLOOR LINE


S.O.G. S.O.G.

750
600
8-10mm Ø @
100mm O.C.

400
NATURAL GRADE LINE GRADE GRADE 4-10mm Ø @
BEAM BEAM 100mm O.C.

400
1700

1300
13-10mm Ø @

2600
100mm O.C.

500

500
FOOTING TIE FOOTING TIE 5-10mm Ø @
BEAM BEAM 100mm O.C.

3-10mm Ø @
100mm O.C.

400

400
S TYPICAL COLUMN ELEVATION
S C A L E : 1 : 1 0 0 MTS
0 100 200
CANTILEVER L1 L2

L1/3 L1/3 L2/3 L2/3

BAR "C" EXTRA TOP BARS BAR "C" EXTRA TOP BARS
WIDTH WIDTH
BAR "A" CONT. TOP BARS BAR "E" STIFFENER BARS
B B
TOP BARS TOP BARS
DEPTH

STIRRUPS STIRRUPS

DEPTH

DEPTH
D

D
STIFF. BARS STIFF. BARS
BAR "D" EXTRA BOT. BARS
BAR "B" CONT. BOT. BARS
L1/7 L1/7 L1/7 L1/7 BOT. BARS BOT. BARS

SPACING OF STIRRUPS SPACING OF STIRRUPS SPACING OF STIRRUPS


@ SUPPORT @ MIDSPAN
EXT. SUPPORT EXT. SPAN INT. SUPPORT INT. SPAN INT. SUPP.

SPACING OF STIRRUPS:
S TYP. RC BEAM ELEVATION
N O T T O S C A L E
A -USE Ø10 STIRRUPS SPACED @ 1 @ 0.05, 4 @ 0.10, 4 @ 0.15, REST @ 0.20 O.C.
B -USE Ø10 STIRRUPS SPACED @ 0.15 O.C..

SIZES R E I N F O R C E M E N T S
BEAM SPACING
MARK B D BAR "A" BAR "B" BAR "C" (EXTRA TOP) BAR "D" (EXTRA BOT.) BAR "E" OF
STIRRUPS
WIDTH DEPTH CONT. TOP CONT. BOT. EXT. SUPP. INT. SUPP. EXT. SPAN INT. SPAN STIFF. BAR

FOOTING TIE BEAM:


FTB 0.40 0.50 3-Ø20 3-Ø20 2-Ø16 2-Ø16 2-Ø16 2-Ø16 2-Ø16 A

GRADE BEAM:
GB 0.30 0.30 2-Ø20 3-Ø20 3-Ø16 3-Ø16 2-Ø16 2-Ø16 2-Ø16 A

2ND, 3RD AND ROOF DECK FLOOR BEAMS


B1 0.40 0.50 4-Ø20 4-Ø20 2-Ø16 2-Ø16 2-Ø16 2-Ø16 2-Ø16 A

B2 0.30 0.40 3-Ø20 3-Ø20 2-Ø16 2-Ø16 2-Ø16 2-Ø16 2-Ø16 A

B3 0.15 0.50 2-Ø16 2-Ø16 B

CB1 0.40 0.50 4-Ø20 4-Ø20 2-Ø16 2-Ø16 2-Ø16 A

CB2 0.50 0.50 4-Ø20 4-Ø20 2-Ø16 2-Ø16 2-Ø16 A

RB1 0.25 0.35 2-Ø16 2-Ø16 1-Ø16 1-Ø16 2-Ø16 A


400 400
150

3-20mm dia. Main Bar Continuous 3-20mm dia. Main Bar Continuous 1-16mm dia. RSB
2-16mm dia. Extra Top Bar

400
1-16mm dia. RSB
500

500
2-16mm dia. Web Bar Continuous 3-16mm dia. Web Bar Continuous
1-16mm dia. RSB
3-16mm dia. Extra Bottom Bar
3-20mm dia. Main Bar Continuous 3-20mm dia. Main Bar Continuous 1-16mm dia. RSB

@ support @ mid-span @ support & @ mid-span

400
300 300

4-20mm dia. Main Bar Continuous


2-20mm dia. Main Bar Continuous 2-20mm dia. Extra Bar
1-16mm dia. Extra Top Bar 2-20mm dia. Main Bar

500
2-16mm dia. Extra Top Bar 2-16mm dia. Web Bar Continuous
400

2-16mm dia. Web Bar Continuous 400 2-16mm dia. Web Bar
2-16mm dia. Extra Bottom Bar
2-20mm dia. Main Bar Continuous 3-20mm dia. Main Bar 4-20mm dia. Main Bar Continuous

@ support @ mid-span @ support

400 400
500

4-20mm dia. Main Bar Continuous 4-20mm dia. Main Bar Continuous
2-20mm dia. Extra Top Bar 4-20mm dia. Main Bar Continuous
2-20mm dia. Extra Bar
500

500

2-16mm dia. Web Bar Continuous 2-16mm dia. Web Bar Continuous

500
2-16mm dia. Web Bar Continuous
2-20mm dia. Extra Bottom Bar
4-20mm dia. Main Bar Continuous 4-20mm dia. Main Bar Continuous
4-20mm dia. Main Bar Continuous

@ support @ mid-span
@ support

300 300 250 250

3-20mm dia. Main Bar Continuous 3-20mm dia. Main Bar Continuous 3-16mm dia. Main Bar Continuous 3-16mm dia. Main Bar Continuous
2-16mm dia. Extra Top Bar

350

350
400

400

2-16mm dia. Web Bar Continuous 2-16mm dia. Web Bar Continuous 2-16mm dia. Web Bar Continuous
2-16mm dia. Web Bar Continuous
2-16mm dia. Extra Bottom Bar
3-20mm dia. Main Bar Continuous 3-16mm dia. Main Bar Continuous 3-16mm dia. Main Bar Continuous
3-20mm dia. Main Bar Continuous

@ support @ mid-span @ support @ mid-span


SCHEDULE OF SLAB REINFORCEMENT

S1 100 12 400 300 400 300 400 300 400 300 B

S2 100 12 400 300 400 - 300 250 - - A

THIICKNESS
S3 100 12 - 175 250 - - 300 200 - A

S TYP. ONE-WAY SLAB DETAIL


N O T T O S C A L E

S TYP. TWO-WAY SLAB DETAIL


N O T T O S C A L E
1' 1 2 3 4 4'
3650 15500

5000 5000 4000 1500

150 300 300 300

150

A'

250 250 250


2790
2600

300 300 300


175 300 300 300 2400

175
175

175
300 300 300

A 300 300 300


5000

2790

300 300 300


300 300

B
1350

250 250 250

B'
300 300 300
15000

5000

2300

C'
1350

175
175

C
SLAB REINFORCEMENT - BOTTOM BAR
SECOND FLOOR SLAB DETAIL
5000

S
S C A L E : 1 : 1 0 0 MTS
0 100 200
TYPICAL TO 2ND & 3RD FLOOR

D
175
175

300 300 300 300 300 300 300 300 300


1' 1 2 3 4 4'
3650 15500

5000 5000 4000 1500

A'
2050 400 400 400
2710 2465 1315
2600

250 400 400 400

250
A 2050

1550
400

400
5000

400

400
400

400
400

2710
1350

300 300 300

B'
400

400
15000

5000

2300
400

400
400

400
400

C'
1350

2710
SLAB REINFORCEMENT - TOP BAR
400

400

SECOND FLOOR SLAB DETAIL


5000

400

S
400
400

S C A L E : 1 : 1 0 0 MTS
400
400

0 100 200
TYPICAL TO 2ND & 3RD FLOOR

2050
D
250
400 400 400 400 400 400 400 400 400
350 350

400 400 400 400 400 400 400 400 400