Vous êtes sur la page 1sur 5

W2E250-HJ32-01 AC axial compact fan

sickled blades (S series)

ebm-papst Mulfingen GmbH & Co. KG


Bachmühle 2 · D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
Limited partnership · Headquarters Mulfingen
County court Stuttgart · HRA 590344

General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen


County court Stuttgart · HRB 590142

Nominal data

Type W2E250-HJ32-01
Motor M2E068-DF

Phase 1~ 1~
Nominal voltage VAC 115 115
Frequency Hz 50 60

Type of data definition fa fa


Valid for approval / standard CE CE
Speed min-1 2600 2850
Power input W 115 160
Current draw A 1.02 1.42
Motor capacitor µF 12 12
Capacitor voltage VDB 220 220
Capacitor standard P0 (CE) P0 (CE)
Max. back pressure Pa 150 120
Min. ambient temperature °C -25 -25
Max. ambient temperature °C 70 55
Starting current A 2 2.1
ml = Max. load · me = Max. efficiency · fa = Running at free air · cs = Customer specs · cu = Customer unit
Subject to alterations

Item no. 11386-5-9980 · Revision 80549 · Release 2014-04-04 · Page 1 / 5

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
W2E250-HJ32-01 AC axial compact fan
sickled blades (S series)

Technical features

Mass 3.3 kg
Size 250 mm
Surface of rotor Coated in black
Material of blades Sheet steel, coated in black
Material of wall ring Die-cast aluminium
Number of blades 7
Direction of air flow "V"
Direction of rotation Counter-clockwise, seen on rotor
Type of protection IP 44; Depending on installation and position
Insulation class "B"
Humidity class F1-2
Max. permissible ambient motor + 80 °C
temp. (transp./ storage)
Min. permissible ambient motor - 40 °C
temp. (transp./storage)
Mounting position Any
Condensate discharge holes None
Operation mode S1
Motor bearing Ball bearing
Touch current acc. IEC 60990 < 0.75 mA
(measuring network Fig. 4, TN
system)
Electrical leads Via terminal strips, integrated capacitor connected via terminal strips
Motor protection Thermal overload protector (TOP) wired internally
Cable exit Variable
Protection class I (if protective earth is connected by customer)
Product conforming to standard EN 60335-1; CE
Approval CCC; UL 2111; CSA C22.2 Nr.77

Item no. 11386-5-9980 · Revision 80549 · Release 2014-04-04 · Page 2 / 5

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
W2E250-HJ32-01 AC axial compact fan
sickled blades (S series)

Product drawing

1 Direction of air flow "V"

Connection screen

L blue N black PE green/yellow

Item no. 11386-5-9980 · Revision 80549 · Release 2014-04-04 · Page 3 / 5

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
W2E250-HJ32-01 AC axial compact fan
sickled blades (S series)

Charts: Air flow 50 Hz


Druck p f s[Pa]für Rho=1,2kg/m^3

qv[cfm]
0 200 400 600 800 1.000 1.200
220

210 0,85

Measurement: LU-29333
200 0,8

190
0,75
Air performance measured as per ISO 5801
180 Installation category A. For detailed
0,7 information on the measuring set-up, please
170 contact ebm-papst. Suction-side noise
levels: LwA measured as per ISO 13347 /
160 0,65 LpA measured with 1m distance to fan axis.
The values given are valid under the
150 0,6 measuring conditions mentioned above and
may vary according to the actual installation
140 situation. With any deviation from the
0,55 standard set-up, the specific values have to
130 be checked and reviewed with the unit
0,5 installed.

p fs_E[IN H2O]
120
4
pf s[Pa]

0,45
110

100 0,4

90
0,35
3
80
0,3
70
0,25
60

50 0,2
2
40
0,15
30
0,1
20
0,05
pf s[P

10
1
a]

0 0
0 200 400 600 800 1.000 1.200 1.400 1.600 1.800 2.000
qv[m^3/h]

Measured values
U f n Pe I qv pfs
V Hz min-1 W A m3/h Pa
1 115 50 2600 115 1.02 1900 0
2 115 50 2570 128 1.12 1735 40
3 115 50 2505 137 1.20 1515 80
4 115 50 2435 147 1.29 1190 110
U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · qv = Air flow · pfs = Pressure increase

Item no. 11386-5-9980 · Revision 80549 · Release 2014-04-04 · Page 4 / 5

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
W2E250-HJ32-01 AC axial compact fan
sickled blades (S series)

Charts: Air flow 60 Hz


Druck p f s[Pa]für Rho=1,2kg/m^3

qv[cfm]
0 200 400 600 800 1.000 1.200
180 0,72
175 0,7
170 0,68
165 0,66
160 0,64
155 0,62
150 0,6 Air performance measured as per ISO 5801
145
Installation category A. For detailed
0,58 information on the measuring set-up, please
140 0,56 contact ebm-papst. Suction-side noise
135 0,54 levels: LwA measured as per ISO 13347 /
130 0,52 LpA measured with 1m distance to fan axis.
125
The values given are valid under the
0,5
measuring conditions mentioned above and
120 0,48 may vary according to the actual installation
115 0,46 situation. With any deviation from the
4 standard set-up, the specific values have to
110 0,44
105 0,42
be checked and reviewed with the unit
installed.
100 0,4

p fs_E[IN H2O]
95 0,38
pf s[Pa]

90 0,36
85 0,34
3
80 0,32
75 0,3
70 0,28
65 0,26
60 0,24
55 0,22
50 0,2
45 0,18
2
40 0,16
35 0,14
30 0,12
25 0,1
20 0,08
15 0,06
10 0,04
pf s[P

5 0,02
1
a]

0 0
0 200 400 600 800 1.000 1.200 1.400 1.600 1.800 2.000 2.200
qv[m^3/h]

Measured values
U f n Pe I qv pfs
V Hz min-1 W A m3/h Pa
1 115 60 2850 160 1.42 2075 0
2 115 60 2760 178 1.53 1880 40
3 115 60 2620 185 1.60 1620 80
4 115 60 2445 194 1.68 1200 110
U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · qv = Air flow · pfs = Pressure increase

Item no. 11386-5-9980 · Revision 80549 · Release 2014-04-04 · Page 5 / 5

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com