Vous êtes sur la page 1sur 1

CLIENT

PLAN CLÉ

SECTION 2
P2-1 P2-1.2 P2-1.3 1.5 P2-2 P2-3 P2-4 P2-5

INGÉNIEUR
P2-G
SALLE DE JEUX
112

ARCHITECTE
EB 50
EB 20mm EB 50
CECD-13
RAE 01
CEFD-13

CECD-21
CEFD-21
P2-H
CECD-24
CEFD-24

STRUCTURE
E-2 PISICNE
129
LOUNGE VIP
113

CEFD-14
CECD-14
P2-J
• L'ENTREPRENEUR DEVRA VÉRIFIER TOUTES LES DIMENSIONS ET
CONDITIONS EXISTANTES SUR LE CHANTIER AVANT LE DÉBUT DES
TRAVAUX.
CA-3
CECD-14 D-2 CA-3 • AUCUNE DIMENSION NE SERA PRISE SUR CE PLAN POUR FIN DE
CEFD-14 RELEVÉ À MOINS QUE CE PLAN SOIT UN ORIGINAL.
L-1

NOTES
CA-2 • TOUTES OMISSIONS OU ERREURS DÉCOUVERTES PAR
L'ENTREPRENEUR OU AUTRES DEVRONT ÊTRE TRANSMISES À
L'INGÉNIEUR AFIN D'APPORTER LES MODIFICATIONS REQUISES
AVANT LE DÉBUT DES TRAVAUX.
EB GZN 20
EB 50 • TOUTE REPRODUCTION OU UTILISATION TOTALE OU PARTIELLE DE
32mm EB ECR 32
PA CE DOCUMENT EST STRICTEMENT INTERDITE À MOINS D'OBTENIR
L'APPROBATION DE LA FIRME DESJARDINS EXPERT CONSEIL.
SALLE MULTI CECD-23 EB 50
CGZN-02
114 40mm CEFD-23 CEFD-1540mm
CECR-03
P2-K 40mm
CECD-15 32mm
CEFD-22 L-2 L-2
CECD-22 L-2 L-2
32mm

EH GZN 20
40mm CEFD-16 EH ECR 32
32mm CECD-16

CA-3 CA-3
P2-L FR-1
D-2

ÉMISSION
YOGA ESC#3
115 120
CEFD-17
CECD-17

1 2022-04-08 DIRECTIVE ME-04 C.P.


CECD-19
0 2022-01-21 CONSTRUCTION C.P.
CEFD-19
2020-07-10 PERMIS J.D.
CEFD-18
EB 50 No DATE ÉMIS POUR: PAR:
CECD-18 RAE 01
RAE 01
P2-M EB 20mm
EB 20mm EB 50

SCEAU
STATIONNEMENT GYM DIMENSIONNEMENT DE LA
150 117 TUYAUTERIE D'ALIMENTATION
DIMENSION
NOMINALE (f.a.) FACTEUR
Ø TUYAU (po-mm) D'ALIMENTATION

APPAREILS EFD ECD EFD ECD TOTAL


AG 01 AG 02
CA-X ½Ø-15Ø - 3 - 3
/16"

RG 01
L-X ½Ø-15Ø ½Ø-15Ø 0.75 0.75 1
EB GZN 20
GZN, 19 GZN, 19 B-X ½Ø-15Ø ½Ø-15Ø 1 1 1.4
4' 10-9

P2-N

PROJET
D-X ½Ø-15Ø ½Ø-15Ø 1 1 1.4
FR-1 E-X ½Ø-15Ø ½Ø-15Ø 1 1 1.4
LOCAL DE LES ½Ø-15Ø ½Ø-15Ø 1.4 1.4
COLLECTE
P2-N.4 160 LV - ½Ø-15Ø 1 1 1.4
VOIR SCHÉMA DE
CHEMINÉE D'AÉROTHERME 100mm RA 01 GAZ (SERIE M-500) NOTES:
100ø

100ø

(INSTALLER SELON LES


GAZ NATUREL PAR ÉNERGIR 1. LES DIMENSIONS DE LA TUYAUTERIE
3000 BLVD THIMENS,
RECOMMANDATIONS DU
MANUFACTURIER ET CSA-B149.1) CAPACITÉ TOTAL DU COMMUN ET D'ALIMENTATION D'EAU FROIDE ET D'EAU VILLE ST-LAURENT
DE LA GÉNÉRATRICE: 6 144 MBH CHAUDE DES APPAREILS SANITAIRES DOIT
PROTECTION PRESSION: 2 PSI CHUTE 1.5 PSI ÊTRE CONFORME AU TABLEAU CI-DESSUS.
MÉCANIQUE c
2. TOUS LES RACCORDEMENTS DES
EB 40mm (COMMUN) CAPACITÉ BOLLARD PAR APPAREILS DE PLOMBERIE SONT DE ½"∅-15
L'ENTREPRENEUR
TOTAL: 2004MBH
LONGUEUR ÉQUIVALENTE:580'-0'' GÉNÉRAL
∅ POUR EFD ET ECD, SAUF INDICATION
CONTRAIRE. RACCORDER UN APPAREIL MÉCANIQUE

TITRE
EMPLACEMENT HYPOTHÉTIQUE DE SEULEMENT SUR LA TUYAUTERIE DE
EB X mm (GENÉRATRICE) 1/2"Ø-15Ø
CAPACITÉ TOTAL: 4 140 MBH
LONGUEUR ÉQUIVALENTE:
L'ENTRÉE GAZ ET DU COMPTEUR À
COORDONNER AU CHANTIER PAR
L'ENTREPRENEUR ET ÉNERGIR
3. POUR LE DIMENSIONNEMENT DES TUYAUX
MAÎTRES, VOIR SCHÉMA AU PLAN M-501 & M-502 PLOMBERIE - DISTRIBUTION -
475:'-0

TOTAL
DIMENSION
ØTUYAU DE FAÇON GÉNÉRALE
REZ-DE-CHAUSSÉE SECTION 2
(f.a.) (po-mm) (SAUF INDICATION
EFD & ECD CONTRAIRE), LE
DIAMÈTRE DE LA
0À2 ½Ø-15Ø TUYAUTERIE
3À7 ¾Ø-20Ø D'ALIMENTATION
SERA
8 À 19 1Ø-25Ø DÉTERMINÉ SELON LA ÉCHELLE: 1 : 100
DESSINÉ PAR: G.SCRAIRE
20 À 37 1¼Ø-32Ø SOMME DES

20055
FACTEURS
38 À 72 1½Ø-40Ø
D'ALIMENTATION S'Y
73 À 271 2Ø-50Ø RAPPORTANT, TEL PRÉPARÉ PAR: G.SCRAIRE
QUE
272 À 580 2½Ø-65Ø SPÉCIFIÉ CI-CONTRE:
581 À 1100 3Ø-80Ø SELON UNE PERTE DE
PRESSION DE:
5.0 psi / 100'-0"
VÉRIFIÉ PAR: C.PETRAS
M-309