11.05 • L'ENTREPRENEUR DEVRA VÉRIFIER TOUTES LES DIMENSIONS ET


11.03 CONDITIONS EXISTANTES SUR LE CHANTIER AVANT LE DÉBUT DES
11.04
P2-C.8 TRAVAUX.
CEFD-01
TUYAUTERIE DANS CECD-01 • AUCUNE DIMENSION NE SERA PRISE SUR CE PLAN POUR FIN DE
LE COMPTOIR TYP. RELEVÉ À MOINS QUE CE PLAN SOIT UN ORIGINAL.

NOTES
P2-D P.A. CA-1 CA-1 • TOUTES OMISSIONS OU ERREURS DÉCOUVERTES PAR
L-1 L-1 L'ENTREPRENEUR OU AUTRES DEVRONT ÊTRE TRANSMISES À
B-1 E-1 L'INGÉNIEUR AFIN D'APPORTER LES MODIFICATIONS REQUISES
E-1 LESS B-1
CA-1 AVANT LE DÉBUT DES TRAVAUX.
E-1 CA-1
L-1
L-1 CECD-06
LESS B-1 CA-1 • TOUTE REPRODUCTION OU UTILISATION TOTALE OU PARTIELLE DE
11.02 CA-1 D-1 CEFD-06
CA-1 E-1 L-1 CE DOCUMENT EST STRICTEMENT INTERDITE À MOINS D'OBTENIR
L-1 L-1 P.A. L'APPROBATION DE LA FIRME DESJARDINS EXPERT CONSEIL.
CEFD-04 D-1 P.A.
D-1 D-1 CA-1
E-1 CECD-04
L-1 LESS B-1
P.A. B-1 L-1
CA-1
CA-1 P.A.
L-1 LESS
CEFD-02 CEFD-05
D-1 CECD-03 CHUTE À DÉCHETS
CECD-02 CECD-05
L-1
CEFD-12 CEFD-11 1102
CECD-12 CECD-11 CEFD-08
CORRIDOR
P-E P.A. P.A. CECD-08
1101
P.A. LESS
CA-1 P.A.
CGZN-03 LESS CA-1
L-1 E-1
ASCENSEURS CGZN-01

ÉMISSION
L-1 LESS
D-1 CECR-01
1100 D-1 CEFD-10 LESS
LESS
CA-1 CA-1
L-1 L-1
P2-E.5 B-1 D-1
L-1
ESC#1
L-1 D-1 E-1
E-1 1103 E-1
11.01 CA-1
CA-1
1 2022-04-08 DIRECTIVE ME-04 C.P.
ESC#2 L-1
CEFD-20 B-1 0 2022-01-21 CONSTRUCTION C.P.
P.A. 1104
CECD-20 2020-07-10 PERMIS J.D.
CEFD-20
P2-F CECD-20 No DATE ÉMIS POUR: PAR:
TUYAUTERIE DANS
LA DALLE TYP. 11.10 11.09
E-1 11.07
CA-1
L-1
P.A. D-1

SCEAU
DIMENSIONNEMENT DE LA
P2-G
TUYAUTERIE D'ALIMENTATION
RAE 01 DIMENSION
NOMINALE (f.a.) FACTEUR
Ø TUYAU (po-mm) D'ALIMENTATION

APPAREILS EFD ECD EFD ECD TOTAL

CA-X ½Ø-15Ø - 3 - 3

L-X ½Ø-15Ø ½Ø-15Ø 0.75 0.75 1


B-X ½Ø-15Ø ½Ø-15Ø 1 1 1.4

PROJET
D-X ½Ø-15Ø ½Ø-15Ø 1 1 1.4
E-X ½Ø-15Ø ½Ø-15Ø 1 1 1.4
LES ½Ø-15Ø ½Ø-15Ø 1.4 1.4
LV - ½Ø-15Ø 1 1 1.4
NOTES:
1. LES DIMENSIONS DE LA TUYAUTERIE
3000 BLVD THIMENS,
D'ALIMENTATION D'EAU FROIDE ET D'EAU VILLE ST-LAURENT
CHAUDE DES APPAREILS SANITAIRES DOIT
ÊTRE CONFORME AU TABLEAU CI-DESSUS.
2. TOUS LES RACCORDEMENTS DES
APPAREILS DE PLOMBERIE SONT DE ½"∅-15
∅ POUR EFD ET ECD, SAUF INDICATION
CONTRAIRE. RACCORDER UN APPAREIL MÉCANIQUE

TITRE
SEULEMENT SUR LA TUYAUTERIE DE
1/2"Ø-15Ø
3. POUR LE DIMENSIONNEMENT DES TUYAUX
MAÎTRES, VOIR SCHÉMA AU PLAN M-501 & M-502 PLOMBERIE - DISTRIBUTION -
TOTAL
DIMENSION
ØTUYAU DE FAÇON GÉNÉRALE
11e ÉTAGE
(f.a.) (po-mm) (SAUF INDICATION
EFD & ECD CONTRAIRE), LE
DIAMÈTRE DE LA
0À2 ½Ø-15Ø TUYAUTERIE
3À7 ¾Ø-20Ø D'ALIMENTATION
SERA
8 À 19 1Ø-25Ø DÉTERMINÉ SELON LA ÉCHELLE: 1 : 100
DESSINÉ PAR: G.SCRAIRE
20 À 37 1¼Ø-32Ø SOMME DES

20055
FACTEURS
38 À 72 1½Ø-40Ø
D'ALIMENTATION S'Y
73 À 271 2Ø-50Ø RAPPORTANT, TEL PRÉPARÉ PAR: G.SCRAIRE
QUE
272 À 580 2½Ø-65Ø SPÉCIFIÉ CI-CONTRE:
581 À 1100 3Ø-80Ø SELON UNE PERTE DE
PRESSION DE:
5.0 psi / 100'-0"
VÉRIFIÉ PAR: C.PETRAS
M-320