Vous êtes sur la page 1sur 1

CLIENT

PLAN CLÉ

SECTION 1

INGÉNIEUR
P2-1 P2-1.2 P2-1.3 1.5 P2-2 P2-3 P2-4 P2-5 P2-6 P2-7 P2-8 P2-9 P2-10

ARCHITECTE
P2-B

P2-B.8

STRUCTURE
P2-C
2.17

E-1
D-1
2.12 2.13 2.14 2.15 2.16 L-1
CA-1
P2-C.8 L-1
CECD-01 L-1
CEFD-01 CA-1
B-1
E-1
P2-D E-1 • L'ENTREPRENEUR DEVRA VÉRIFIER TOUTES LES DIMENSIONS ET
E-1 D-1 CONDITIONS EXISTANTES SUR LE CHANTIER AVANT LE DÉBUT DES
D-1 TRAVAUX.
E-1 E-1 CA-1
L-1 CA-1
L-1
CA-1 L-1 • AUCUNE DIMENSION NE SERA PRISE SUR CE PLAN POUR FIN DE
40 40 LESS
D-1 RELEVÉ À MOINS QUE CE PLAN SOIT UN ORIGINAL.

NOTES
CA-1 CA-1 CECD-09 • TOUTES OMISSIONS OU ERREURS DÉCOUVERTES PAR
LESS CEFD-06 P.A.
LESS L-1 D-1 CA-1 L-1 LESS CEFD-09
LESS L'ENTREPRENEUR OU AUTRES DEVRONT ÊTRE TRANSMISES À
D-1 L-1 D-1 CECD-06
P.A. 2.18 L'INGÉNIEUR AFIN D'APPORTER LES MODIFICATIONS REQUISES
P.A. CEFD-07 AVANT LE DÉBUT DES TRAVAUX.
LESS CECD-07
LESS • TOUTE REPRODUCTION OU UTILISATION TOTALE OU PARTIELLE DE
EB EFD 40 P.A. P.A. P.A. P.A. E-1
CE DOCUMENT EST STRICTEMENT INTERDITE À MOINS D'OBTENIR
CEFD-03 CEFD-04 CEFD-05 CHUTE À DÉCHETS L'APPROBATION DE LA FIRME DESJARDINS EXPERT CONSEIL.
CEFD-02 CORRIDOR CECD-05 202
EB ECD 40 CECD-03 CECD-04
CECD-02 CEFD-12
201 CEFD-11 VOIR SCHÉMA DE
CECD-12 CECD-11 DISTRIBUTION LESS
P-E P.A.
P.A.

CGZN-03
L-1 CA-1 P.A.
ASCENSEURS CGZN-01 CA-1
CA-1 D-1 CEFD-10
200 CECR-01 L-1
LESS D-1 L-1 CECD-10
P.A. L-1
LESS
CA-1 D-1
P2-E.5 L-1
D-1
E-1 ESC#1

ÉMISSION
E-1 203
CA-1 E-1
L-1
ESC#2 E-1
E-1 B-1
204

P2-F
D-1
2.19 1 2022-04-08 DIRECTIVE ME-04 C.P.
2.22 2.21 2.20 0 2022-01-21 CONSTRUCTION C.P.
CEFD-20 2020-07-10 PERMIS J.D.
CEFD-20 CECD-20 L-1
CECD-20 SALLE ÉLEC L-1
No DATE ÉMIS POUR: PAR:
203 CA-1

P2-G
D-1
CA-1 2.01

SCEAU
L-1
TUYAUTERIE D'EAU
CECD-13 DOMESTIQUE À INSTALLER DIMENSIONNEMENT DE LA
CEFD-13 DU CÔTÉ CHAUD DU MUR. TUYAUTERIE D'ALIMENTATION
2.11 DIMENSION
NOMINALE (f.a.) FACTEUR
Ø TUYAU (po-mm) D'ALIMENTATION
E-1 P.A.
CA-1
APPAREILS EFD ECD EFD ECD TOTAL
D-1
LESS L-1
CECD-21 CA-X ½Ø-15Ø - 3 - 3
CEFD-21
L-X ½Ø-15Ø ½Ø-15Ø 0.75 0.75 1
P2-H P.A.
CECD-24 B-X ½Ø-15Ø ½Ø-15Ø 1 1 1.4
CEFD-24

PROJET
D-X ½Ø-15Ø ½Ø-15Ø 1 1 1.4
LESS D-1
P.A.
E-X ½Ø-15Ø ½Ø-15Ø 1 1 1.4
LES ½Ø-15Ø ½Ø-15Ø 1.4 1.4
LV - ½Ø-15Ø 1 1 1.4
NOTES:
1. LES DIMENSIONS DE LA TUYAUTERIE
3000 BLVD THIMENS,
D'ALIMENTATION D'EAU FROIDE ET D'EAU VILLE ST-LAURENT
CHAUDE DES APPAREILS SANITAIRES DOIT
ÊTRE CONFORME AU TABLEAU CI-DESSUS.
2. TOUS LES RACCORDEMENTS DES
APPAREILS DE PLOMBERIE SONT DE ½"∅-15
∅ POUR EFD ET ECD, SAUF INDICATION
CONTRAIRE. RACCORDER UN APPAREIL MÉCANIQUE

TITRE
SEULEMENT SUR LA TUYAUTERIE DE
1/2"Ø-15Ø
3. POUR LE DIMENSIONNEMENT DES TUYAUX
MAÎTRES, VOIR SCHÉMA AU PLAN M-501 & M-502 PLOMBERIE - DISTRIBUTION - 2e
TOTAL
DIMENSION
ØTUYAU DE FAÇON GÉNÉRALE
ÉTAGE SECTION 1
(f.a.) (po-mm) (SAUF INDICATION
EFD & ECD CONTRAIRE), LE
DIAMÈTRE DE LA
0À2 ½Ø-15Ø TUYAUTERIE
3À7 ¾Ø-20Ø D'ALIMENTATION
SERA
8 À 19 1Ø-25Ø DÉTERMINÉ SELON LA ÉCHELLE: 1 : 100
DESSINÉ PAR: G.SCRAIRE
20 À 37 1¼Ø-32Ø SOMME DES

20055
FACTEURS
38 À 72 1½Ø-40Ø
D'ALIMENTATION S'Y
73 À 271 2Ø-50Ø RAPPORTANT, TEL PRÉPARÉ PAR: G.SCRAIRE
QUE
272 À 580 2½Ø-65Ø SPÉCIFIÉ CI-CONTRE:
581 À 1100 3Ø-80Ø SELON UNE PERTE DE
PRESSION DE:
5.0 psi / 100'-0"
VÉRIFIÉ PAR: C.PETRAS