Orsenna 2011 1 Sommaire Orsenna 2011 2 Introduction Prsentation Orsenna Prsentation de la technologie Prsentation des produits Dmonstration du produit FlowMon Questions et rponses Orsenna 2011 3 Orsenna : Qui sommes-nous ? Supervision & Audit Rseau
Intgration produits Supervision. Dveloppement de PlugIns. Intgration produits Audit des flux Netflow, Sflow, Jflow Produits Complmentaires (Appliance SMS, Serveur Syslog, Diagnostic Switches , Sondes) Formation & Rgie de supervision
Orsenna 2011 4 Rfrences Plus de 500 missions daudit et de supervision depuis 2002. Type Noms Banques, Assurances FIDEURAM BANK, BANQUE POPULAIRE, GIE Carte Bancaire, GMF, Caisse des Dpts, Socit Gnrale Distribution BRICORAMA, RELAY, NICOLAS, AELIA, HISTOIRE DOR, LANVIN, MAC DONALDS, MIDAS Industries SCHLUMBERGER, ALCAN, ARCELOR, DANONE, EADS, STRYKER Administration ADEME, OPERA DE PARIS, MINISTERE DEFENSE Ecoles, Universits ENSAE, ENSTA, Mairies, Conseil Ville TROYES, CG16, CR PACA Oprateur CORIOLIS, B3G Transport COFIROUTE, SERVAIR, APRR, ASF Orsenna 2011 5 Services autour des produits
Formation Tuning Performances Mises jour de versions Installation et dploiement Gestion de projet Orsenna 2011 6 Mise en uvre Audit initial , Mise en uvre pr requis Spcifications dtailles & Architecture Documentations Cahier recette
Equipe Technique : helpdesk@orsenna.fr Denis Chauvicourt Antoine Cru Quentin Ozenne Tlphone : 01.34.93.35.35
Orsenna 2011 8 Questions ? Q & A 9 SNMP ICMP Suivi dutilisation de linfrastructure Monitoring des compteurs (SNMP) Monitoring des interfaces (SNMP) Suivi des flux Statistiques applicatives (Netflow/Sflow,....) Sondes Suivi dtaill de linfrastructure Monitoring + complexe BGP, STP (SNMP) Monitoring status (SSH) SNMP SSH Suivi temps de rponse Oprations IP SLA IP SLA ( Cisco) Netflow - Techonologie
Cr par Cisco en 1996, Netflow est le standard de fait pour collecter des donnes IP oprationnelles.
Cest un protocole de niveau 3 (Couche rseau)
La diffrence avec les autres analyseurs de trafic (MRTG) est que Netflow est tourn vers le niveau application et pas seulement en SNMP. Grce Netflow on peut dire que 40% de lutilisation de la bande passante est utilis pour le http, 20% pour
IpFix standardisation de la version 9 de Netflow
Orsenna 2011 10 Netflow - Technologie
Chaque constructeur utilise les mme caractristiques que Netflow en lappelant diffremment : Jflow => Juniper Cflowd => Alcatel-Lucent NetStreal => 3Com / H3C
Le concept majeur de Netflow est la notion de flux: Adresses IP source et destination, Protocole (TCP, UDP, ICMP,), ToS (Type Of Service) Ports applicatifs (HTTP, SMTP, DNS,), Interfaces dentre et de sortie du routeur.
Permet de voir les volutions des flux pour permettre dadapter la politique de QOS (Quality Of Service). Orsenna 2011 11 Netflow - Technologie Netflow permet de : Connatre lutilisation du rseau par les applications Comprendre par qui, quand, et o est utilis le rseau Mesurer lefficacit du rseau et des ressources Apprhender l'impact des changements au rseau Dtecter les anomalies et les vulnrabilits de scurit de rseau Auditer la conformit et les processus business De rpondre des questions du genre: Peut-on mettre en place la VOIP ? Pourquoi mon application / serveur est lent ?
La technologie Netflow peut tre utilise dans une grande varit dapplications pour : Surveillance en temps rel du rseau Analyse des nouvelles applications et leur impact sur le rseau. Capacity planning Dtection et classification d'incidents de scurit Accounting et facturation Troubleshooting (lenteurs rseaux)
Orsenna 2011 12 Netflow - Technologie Orsenna 2011 13 Mesures en temps rel depuis chaque port grce un agent prsent sur lquipement. Collecteur et analyseur NETFLOW 90% des bnfices dun analyseur rseau 2% - 3% charge CPU Traffic rseau augmente de 1% - 3% = ~10 NetFlow interfaces Intern et Boston Berlin Paris, France = Router = Switch NetFlow collecteur = NetFlow Data Miroir Probes, Flow Publisher, FlowMon Analyse de flux distribue Serveurs chargs
Voix Virus Hacking Multicast DNS Peer-to-peer Worms Top hosts, conversations, protocols Evnements sur le rseau Limite de la stratgie Top 10 Serveurs chargs
Voix Virus Hacking Multicast DNS Peer-to-peer Worms Top hosts, conversations, protocols Evnements sur le rseau Limite de la stratgie Top 10 22,772 Conversations sur UNE MINUTE! - De 900KB Exemple MS-SQL Slammer Sminaire 18 Primtre Prrequis Exemple : Netflow
Analyse Simple objectifs Netflow Top 10 Lien Internet 10 Mb/s de trafic charg 20 % Analyse + Complexe objectifs Netflow diagnostic Lan Lien Backbone Liens 1Gb/s charg 50 %
Sflow Orsenna 2011 20 Switching ASIC 1 in N samplin g packet header src/dst i/f sampling parms forwarding user ID URL i/f counters sFlow agent forwardin g tables interface counters sFlow Datagram eg 128B rate pool src 802.1p/Q dst 802.1p/Q next hop src/dst mask AS path communitie s localPref src/dst Radius TACACS NetFlow / sFlow Collector & Analyzer Switch/Router NetFlow Netflow
Le routeur compte le nombre de paquets et doctets reus pour chaque flux
Ds quil reoit un paquet, le routeur cr une nouvelle entre si le flux nest pas connu ou bien incrmente le compteur du flux si il est dj prsent.
La mmoire du routeur ntant pas infinie, il faut faire le tri. Pour cela le routeur retire automatiquement du cache un flux lorsque celui-ci a t inactif pendant un certain temps (inactive timeout) et le supprime sil a t actif trop longtemps (active timeout).
Le routeur se sert de la date du dernier paquet reu pour ce flux et la compare la date actuelle pour connatre linactivit de celui-ci.
Lorsquun flux a expir et est supprim du cache, il peut tre export vers une machine de collecte.
Orsenna 2011 22 Netflow
Il existe 9 versions du protocole Netflow.
Les versions 2, 3, 4, 6 => pas sorties sur le march (interne chez Cisco).
La version 5 est la plus utilise sur les routeurs (seulement pour IPv4)
La version 7 est spcifique aux Switchs Catalyst.
La dernire version est la 9, elle supporte lIPv6 ainsi que le MPLS.
Orsenna 2011 23 Netflow Vs Sflow Sflow ralise un chantillonnage (choix personnel => N paquet).
Cela consomme donc moins de charge CPU sur les quipements.
Moins de bande passante consomme.
Orsenna 2011 24 Netflow Vs Sflow Il est donc moins prcis que NetFlow court terme. Nanmoins sur une grande priode, nous retrouverons les mmes rsultats.
Orsenna 2011 25 NetFlow SFlow Netflow Vs Sflow
Lequel faut-il utiliser et quel moment ? NetFlow : analyse prcise du rseau => analyse de scurit par exemple Sflow : permet davoir une vue sur lutilisation des ressources du rseau.
Nous avons donc ensuite diffrents logiciels et quipements en fonction des besoins de chaque personne :
WUG NetFlow monitor et Orion Netflow Traffic Analyser : outils de reporting / statistiques. Scrutinizer et flow analytics : logiciel ddi lanalyse de flux rseau. FlowMon : quipement ddi lanalyse de flux rseau. Observer : Analyseur rseau => capture le flux.
Orsenna 2011 26 Agent Logiciel / Matriel Pourquoi prendre un agent matriel plutt quun agent logiciel ? Un ordinateur peut souvent tre dplac, ce qui rendra lagent indisponible. Moins de maintenance raliser. Besoin dun PC ddi, ce qui implique un clavier, un cran
TAP mode cela peut se reprsenter comme un Y, le flux arrive sur la branche du bas, puis se divise en deux, une partie reste sur le rseau tandis que lautre va vers lagent matriel. SPAN mode Mirroring dun port vers un autre. RSPAN mode Mirroring dun port du routeur vers un port dun autre routeur.
Equipements ne supportant pas NetFlow besoin dun agent matriel ou logiciel: Cisco 2900, 3500, 3660, 3750, Nexus 5000 Netgear Bintec Pour la configuration: http://www.plixer.com/products/netflow- sflow/configure-netflow-sflow.php
Orsenna 2011 29 Equipements Equipements supportant SFlow: 3Com : 4800G Family AlaxalA Networks : AX7800R ; AX7800S ; AX7700R ; AX5400S Alcatel-Lucent : OmniSwitch 6850 ; OmniSwitch 9000 series Allied Telesis : SwitchBlade 7800R series ; SwitchBlade 7800S series ; SwitchBlade 5400S series Blade Network Technologies : HP 10Gb Ethernet BL-C Switch ; HP 1:10Gb Ethernet BL-C Switch ; HP GbE2c Layer2/3 Ethernet Blade Switch Brocade : BigIron series ; FastIron series ; IronPoint series ; NetIron series ; SecureIron series ; ServerIron series Comtec Systems : !-Rex 16Gi & 24Gi & 24Gi-Combo Dell : PowerConnect 6200 series ; PowerConnect 8000 series D-Link : DGS-3600 series Enterasys : G-Series ; SecureStack B3 ; SecureStack C3 Extreme Networks : Alpine 3800 series ; BlackDiamond 6800 series ; BlackDiamond 8800 series ;BlackDiamond 10808 ; BlackDiamond 12804C ; BlackDiamond 12800R Series ; Summit X150 Series ; Summit_X250e Series ; Summit X450 Series ; Summit i series Force10 Networks : C series ; E series H3C : H3C S5800 Series ; H3C S5820X Series ; H3C S7500E Series Switches ; H3C S9500E Series Switches ; H3C S12500 Series Data Center Switches ; H3C MSR 20-1X Series Routers
Orsenna 2011 30 Equipements Equipements supportant SFlow: Hewlett-Packard : ProCurve 2610 series ; ProCurve 2800 series ; ProCurve 2900 series ; ProCurve 2910al series ; ProCurve 3400cl series ; ProCurve 3500yl series ; ProCurve 4200vl series ; ProCurve 5300xl series ; ProCurve 5400zl series ; ProCurve 6200yl series ; ProCurve 6400cl series ; ProCurve 6600 series ; ProCurve 8212zl ; ProCurve 9300m series ; ProCurve Routing Switch 9408sl ; ProCurve Wireless Edge Services xl Module ; ProCurve Wireless Edge Services zl Module ; ProCurve Access Point 530 Hitachi : GR4000 ; GS4000 ; GS3000 IBM : c-series ; g-series ; m-series ; r-series ; s-series ; x-series ; J08E and J16E ; J48E InMon Corp. : Virtual Probe Juniper Networks : EX3200 series ; EX4200 series ; EX8200 series MRV : OptiSwitch-MR series NEC : IP8800/R400 series ; IP8800/S400 series ; IP8800/S300 series ; IP8800/S3640 series ; IP8800/S3640 ER series ; IP8800/S3630 series ; IP8800/S2400 series NETGEAR : GSM7352S-200 ; GSM7328S-200 Open vSwitch : Open vSwitch Vyatta : Vyatta 514 ; Vyatta 2500 series ; Vyatta 3500 series ; Vyatta Core (VC) Routing & Security Software ; Vyatta Virtual Router, Firewall, VPN XRoads Networks : EdgeXOS
Orsenna 2011 31 Exemple de configuration Orsenna 2011 32 Configuration de base CISCO
Router> enable passer en mode enable Router# configure terminal passer en mode configuration Router(config)# ip flow-export destination permet dexporter le flux vers une 172.16.10.2 9996 adresse sur le port 9996 (port dfaut)
Router(config)# ip flow-export version 9 Utilisation de la version 9 de Netflow Router(config)# interface ethernet 0/0 Router(config-if)# ip flow ingress supervision du trafic allant dans linterface Router(config-if)# ip flow egress supervision du trafic sortant de linterface Router(config-if)# exit Router(config-if)# end
Vrification
1. show ip flow interface voir la configuration actuelle du NetFlow 2. show ip cache flow voir les flux en activits ainsi que la 3. show ip cache verbose flow ressource utilise
Exemple de configuration Orsenna 2011 33 Configuration de base Mikrotik : Exemple de configuration Orsenna 2011 34 Configuration pour Alcatel Omniswitch (Sflow) :
Configuration pour Extreme Network (Sflow):
Configuration pour HP (Sflow) :
Ntop Qu'est-ce que Ntop ? Ntop est un outil libre. Cest un collecteur Nflow/IPfix Il capture et analyse les trames dune interface. Il permet dobserver une majeure partie des caractristiques du trafic entrant et sortant. Stockage des statistiques au format RRD
Logo :
Lien : http://www.ntop.org/
Orsenna 2011 35 Nprobe Qu'est-ce que Nprobe ? Cest un agent logiciel. Idal pour les devices qui nincorporent pas de faon hardware une sonde Netflow. Il peut analyser le trafic et gnrer un flux standard Netflow . Disponible pour Windows, Unix et Mac. Supporte IPv4 et Ipv6. Possibilit dtre en mode collecteur de flux and en proxy. Analyse de trafic VoIP. Totalement configurable par lutilisateur. Compatible avec les collecteurs des constructeurs Fluke, Cisco, Dartware, AdventNet, Plixer, SolarWinds
Logo :
Lien : http://www.ntop.org/nProbe.html
Orsenna 2011 36 Nprobe Qu'est-ce que Nprobe ?
Orsenna 2011 37 WhatsUP Flow Publisher Qu'est-ce que Flow Publisher ? Cest un agent logiciel. Il permet l'analyse du trafic rseau pour chaque priphrique et segment du rseau. De dterminer les utilisateurs, applications ou sources de trafic qui consomment de la bande passante. Recevoir des alertes en temps rel lorsque les paramtres de trafic surveills dpassent des seuils dfinis. Assurer que les applications de l'entreprise disposent de toute la bande passante ncessaire. Accder plus de 40 rapports mobiles et Web pour l'tablissement d'une base de rfrence et l'analyse. Cre des enregistrements compatibles NetFlow v1, v5 ou v9 partir du trafic brut
Orsenna 2011 38 WhatsUP Flow Publisher Orsenna 2011 39 TAP Switch Le commutateur transmet le trafic mis en miroir l'agent Flow Publisher L'agent transmet les enregistrements NetFlow au collecteur Flow Monitor Le point d'accs test transmet le trafic bidirectionnel l'agent Flow Publisher L'agent serveur transmet les enregistrements NetFlow au collecteur de Flow Monitor ` Agent Flow Publisher sur PC ` Collecteur de WhatsUp Gold et Flow Monitor Serveur avec l'agent Flow Publisher install
FlowMon Qu'est-ce que FlowMon ? Cest un agent matriel. Il est bas sur les technologies NetFlow V5/V9 Donne des informations sur qui communique avec qui ? Pendant combien de temps ? Quel protocol ? Combien cela prend de bande passante ? Une solution pour tout types de rseau.
FlowMon Rapports : Facilement personnalisable Envoi automatique en format PDF
Orsenna 2011 42
Nmon - Nbox Qu'est-ce que la Nbox ? Cest un agent matriel. Il analyse le flux rseau => analyse et export de donnes. Permet danalyser la disponibilit, la performance et les problme sur le rseau. nBox inclut une sonde Netflow (nProbe) ainsi quun collecteur (ntop) pour les flux NetFlow v5/v9/Ipfix.
Ipswitch Flow Monitor Orsenna 2011 46 Qu'est-ce que Flow Monitor ? Cest un outil de reporting / statistique.
Logo :
Lien : http://www.whatsupgold.com/products/whatsup-gold- plugins/flow-monitor/ PRTG - Traffic Grapher Orsenna 2011 47 Qu'est-ce que Traffic Grapher ? Il est dot dun serveur web intgr => permet daccder aux graphiques et aux tableaux partir dun navigateur web. Utilise trois mthodes de surveillance : SNMP pour les compteur de trafic. Analyse des paquets rseau entrants/sortants qui transitent sur la carte rseau dun ordinateur => capture de paquets. Analyse des paquets Cisco NetFlow Fiabilit de la surveillance du rseau (plus de 100 000 utilisateurs chaque jour) Classification du trafic rseau en fonction de l'adresse IP, du protocole et d'autres paramtres Fonctionne avec la plupart des commutateurs, routeurs, pare-feu et autres quipements rseau Poste de surveillance permettant la supervision de plusieurs milliers de sondes Version Freeware disponible pour les petits rseaux
Logiciel ddi lanalyse de flux (fonctions prcises et pousses). Logiciel permettant de fournir des informations concernant le rseau (bande passante, graphique, rpartion des charges). Scrutinizer peut recevoir des flux d'un nombre illimit d'interfaces. Scrutinizer s'intgre avec le logiciel WhatsUp Professional d'Ipswitch.
Orsenna 2011 50 Links change color based on utilization Mouse over link and ALT tag gives full interface name (e.g. ifAlias) Arrow on link gives highest utilization direction Click on link for top talkers for the last 6 minutes for that direction Cartographie Plixer - Scrutinizer Orsenna 2011 51 Charges Plixer Flow Analytics Qu'est-ce que Flow Analytics ? Cest un add-on pour Scrutinizer. Permet darchiver les donnes NetFlow aprs 24 heures. Identification des applications, conversations, flux, protocoles plus facilement. Dclencher des alarmes en fonction de seuils. Possibilit de mettre des alarmes et de crer des rapports. Nouvelle fentre pour voir directement les problmes du rseau.
Equipe Technique : helpdesk@orsenna.fr Denis Chauvicourt Antoine Cru Quentin Ozenne Tlphone : 01.34.93.35.35
NBAR Nbar Network Based Application Recognition
Permet de saffranchir des limites des ACL peut identifier des applications ou des URLs.
Nbar reconnait les applications utilisant les ports TCP et UDP.
Classification approfondie : HTTP et ICA (Citrix applications).
Orsenna 2011 59 NBAR La dcouverte dapplications et de protocoles est une fonction associe NBAR.
NBAR collecte les statistiques sur les applications prsentes sur le rseau. Orsenna 2011 60 NBAR La technologie NBAR est apparue sur les routeurs 7200 et ensuite sur les Catalyst 6500.
NBAR hardware est apparu sur le Catalyst 6500 sous la forme dune carte supervisor (Engine 32 PISA) : Orsenna 2011 61 NBAR Orsenna 2011 62