Vous êtes sur la page 1sur 1

Zone A1 Caisson d'air neuf

2000m3/h Caisson d'air neuf


2200m3/h
Caisson d'air neuf
2200m3/h

G.A.N Ø400
V.C.cassette
D.R :400x400 D.R :400x400 D.R :400x400 D.R :400x400 EG/REG PPR Ø26/40 Pf = 5 kW
2000m³/h. 2000m³/h. 2000m³/h. 2000m³/h.
235,37

G.A.N Ø160

EG/REG PPR Ø26/40


Débit: 200m³/h.

DETAIL 1

341,30
CTA
V.C.cassette
Pf = 40.00 kW
Débit: = 10000 m³/h Pf = 5 kW
EG/REG EG/REG PPR Ø26/40
PPR Ø33/50 1492,52 EG/REG
PPR Ø33/50 G.A.N Ø400 235,87

G.A.N Ø160
Débit: 200m³/h.

EG/REG PPR Ø33/50

323,97
EG/REG
PPR Ø33/50
EG/REG PPR Ø26/40 V.C.cassette
235,87 Pf = 5 kW

D.S :400x400 D.S :400x400 D.S :400x400 D.S :400x400


G.A.N Ø160
2000m³/h. 2000m³/h. 2000m³/h. 2000m³/h.
Débit: 200m³/h.

1088,12

V.C.Gainable

EG/REG PPR Ø42/63


Pf = 8.00 kW
Débit: = 1085 m³/h
D.R :400x400 D.S :400x400 G.R :600x300
2000m³/h.

810,52
2000m³/h. 1085m³/h.

G.A.N Ø400
D.S :800x300
1085 m³/h.
V.C.Gainable

G.A.N Ø160
# Pf = 8.00 kW
Débit: = 1085 m³/h G.R :600x300
Débit: 200m³/h. G.A.N Ø160

V.C.cassette
1085m³/h.

Pf = 10 kW
D.R :400x400 D.S :400x400 EG/REG Débit: 200m³/h.
2000m³/h. 2000m³/h. PPR Ø33/50 # D.S :800x300
248,24

1085 m³/h. G.A.N Ø160


Débit: 200m³/h.

G.A.N Ø315
EG/REG
PPR Ø33/50

75,87
EG/REG PPR Ø33/50
1761,82 Salon VVIP
121,82

EG/REG PPR Ø33/50


EG/REG PPR Ø42/63
D.S :400x400 D.S :400x400 D.S :400x400 D.S :400x400
2000m³/h. 2000m³/h. 2000m³/h. 2000m³/h.

487,96
G.A.N Ø160

428,16
Caisson d'air neuf G.A.N Ø315
2000m3/h

G.A.N Ø160
G.A.N Ø400 G.A.N Ø400 CTA
151,89

Pf = 40.00 kW

G.A.N Ø250
Débit: = 10000 m³/h EG/REG EG/REG PPR Ø60/90
PPR Ø33/50 648,71

SALON VIP DETAIL 1

EG/REG PPR Ø60/90


D.S :400x400
D.S :400x400
535m²
D.S :400x400 EG/REG P.F:60.50 KW
2000m³/h. D.S :400x400
2000m³/h. 2000m³/h. 2000m³/h. PPR Ø73/110 PAC.....

245,87
3étage Vers en Niveau
"Sous-Sol"

734,60

EG/REG PPR Ø60/90

EG/REG P.F:60.50 KW
PPR Ø73/110 PAC..... LT 546,18
EG/REG PPR Ø60/90

3 étage Vers en Niveau


G.A.N Ø250

"Sous-Sol" EG/REG PPR Ø73/110


36 marches de 17.5/30 cm

680,49

EG/REG PPR Ø73/110


Eau glacée CM01
(221kw +20 kw )
Gaine A.R :1400x450

EG/REG PPR Ø60/90


-EG/REG PPR Ø73/110
3étage /1étage ZONE A1 Vers CTA en Niveau "RDC".
G.A.N Ø160
Débit: 200m³/h. Vers en Niveau "Sous-Sol"

Débit: 2000m³/h.
209,33
Eau glacée CM02 (195 kw )
EG/REG P.F:84 KW PPR 46 marches
-EG/REG de 17.45/30
PPR Ø73/110 cm
EG/REG PPR Ø33/50 Ø108/125PAC... 1étage ZONE A2 Vers
V.C.cassette 2 étage Vers en Niveau en Niveau "Sous-Sol"
V.C.cassette Pf = 4.50 kW "Sous-Sol".
Pf = 7.50 kW
Personnel
sécurité
1266,82

G.A.N Ø160

Vous aimerez peut-être aussi