15.06.2011 SPA01-ENERGY-2E-EN SPA01-ENERGY-3E-EN SPA01-ENERGY-4E-EN SPA01-ENERGY-5E-EN SPA01-ENERGY-6E-EN SPA03-ENERGY-1E-EN SPA03-ENERGY-2E-EN SPA03-ENERGY-3E-EN SPA03-ENERGY-4E-EN SPA03-ENERGY-5E-EN SPA02-ENERGY-2E-EN SPA02-ENERGY-1E-EN SPA04-ENERGY-1E-EN SPA04-ENERGY-2E-EN SPA04-ENERGY-3E-EN SPA04-ENERGY-4E-EN SPA04-ENERGY-5E-EN SPA04-ENERGY-6E-EN SPA04-ENERGY-7E-EN SPA05-ENERGY-1E-EN SPA05-ENERGY-2E-EN SPA06-ENERGY-1E-EN SPA06-ENERGY-2E-EN SPA06-ENERGY-5E-EN SPA06-ENERGY-6E-EN SPA06-ENERGY-9E-EN SPA06-ENERGY-10E-EN 15.06.2011 15.06.2011 SPA03-ENERGY-6E-EN SPA03-ENERGY-7E-EN SPA04-ENERGY-8E-EN SPA04-ENERGY-9E-EN SPA05-ENERGY-3E-EN SPA06-ENERGY-3E-EN SPA06-ENERGY-4E-EN SPA06-ENERGY-7E-EN SPA06-ENERGY-8E-EN SPA06-ENERGY-11E-EN SPA06-ENERGY-12E-EN SPA08-ENERGY-1E-EN SPA08-ENERGY-2E-EN SPA08-ENERGY-3E-EN SPA08-ENERGY-4E-EN SPA07-ENERGY-1E-EN 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 Contents of drawing Plinth, horizontal installation Plinth, horizontal installation Plinth, horizontal installation Plinth, horizontal installation Plinth, horizontal installation, starting with cut panel Plinth, vertical- and horizontal installation Vertical joint, horizontal installation J oint between panels, vertical- and horizontal installation J oint between panels, horizontal installation External corner, horizontal installation Internal corner, horizontal installation Internal corner, horizontal installation Parapet, Side eaves section, horizontal installation Vertical joint, horizontal installation Vertical joint, horizontal installation Vertical joint, horizontal installation Vertical joint, horizontal installation External corner, horizontal installation External corner, horizontal installation External corner, horizontal installation External corner, horizontal installation External corner, horizontal installation External corner, horizontal installation Parapet, gable eaves section, horizontal installation Cantilever eaves, Side eaves section, horizontal installation Cantilever eaves, gable eaves section, horizontal installation Eaves, Side eaves section, horizontal installation Eaves, gable eaves section, horizontal installation Vertical joint, horizontal installation Vertical joint, horizontal installation, parapet External corner, horizontal installation External corner, horizontal installation, parapet Internal corner, horizontal installation, parapet Parapet, Side eaves section, vertical- and diagonal installation Parapet, gable eaves section, vertical- and diagonal installation Cantilever eaves, Side eaves section, horizontal installation Cantilever eaves, gable eaves section, horizontal installation Eaves, Side eaves section, horizontal installation Eaves, gable eaves section, horizontal installation System window, vertical section, horizontal installation System window, horizontal section, horizontal installation System window, vertical section, horiz. installation, supporting structure System window, horizontal sect., horiz. installation, supporting structure Uplifted roofing, vertical section, horizontal installation City sector Building type . . . Sandwich panel SPA ENERGY PRINCIPLE DETAIL DRAWINGS External walls (54 pcs) . . Block Site/Reg. nr. . . File nr. . Drawing type . Contents of drawing Scale 1:Z Building, Name and address Date 19.08.2013 Drawn by Ruukki Designer . Checked . Work nr. Work nr. Drw. nr. Rev. . Nr. Ruukki Construction Oy Vimpelintie 661 tel +358 2059 127 FI - 62900 ALAJ RVI fax +358 2059 27700 FINLAND www.ruukki.com D . 10.06.2013 04.06.2012 04.06.2012 04.06.2012 04.06.2012 04.06.2012 04.06.2012 04.06.2012 04.06.2012 04.06.2012 04.06.2012 04.06.2012 04.06.2012 10.06.2013 10.06.2013 10.06.2013 10.06.2013 10.06.2013 10.06.2013 10.06.2013 10.06.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 Drawing nr. Rev. date Date 15.06.2011 SPA09-ENERGY-1E-EN SPA09-ENERGY-2E-EN SPA09-ENERGY-3E-EN SPA09-ENERGY-4E-EN SPA09-ENERGY-7E-EN SPA09-ENERGY-8E-EN SPA08-ENERGY-5E-EN SPA08-ENERGY-6E-EN SPA09-ENERGY-5E-EN SPA09-ENERGY-6E-EN 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 15.06.2011 Contents of drawing System door, vertical section, horizontal installation System door, horizontal section, horizontal installation System door, vertical section, horiz. installation, supporting structure System door, horizontal section, horiz. installation, supporting structure Overhead door, vert. section, horiz. installation, supporting structure Overhead door, horiz. section, horiz. installation, supporting structure Window, vertical section, horizontal installation Window, horizontal section, horizontal installation Door, vertical section, horizontal installation Door, horizontal section, horizontal installation City sector Building type . . . Sandwich panel SPA ENERGY PRINCIPLE DETAIL DRAWINGS External walls (54 pcs) . . Block Site/Reg. nr. . . File nr. . Drawing type . Contents of drawing Scale 1:Z Building, Name and address Date 19.08.2013 Drawn by Ruukki Designer . Checked . Work nr. Work nr. Drw. nr. Rev. . Nr. Ruukki Construction Oy Vimpelintie 661 tel +358 2059 127 FI - 62900 ALAJ RVI fax +358 2059 27700 FINLAND www.ruukki.com D . 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 19.08.2013 SANDWICH PANELS 001. Sandwich panel SPA ENERGY 80-230 002. Sandwich panel SPA ENERGY corner panel FLASHINGS 100. Standard purlins and starting tracks 101-109. Purlins and other t>2mm fastening flashings 111-119. Plinth flashings 121-124. Fastening plates (for vemo-fastenings) 125-129. Purlins 131-159. Vertical seam-, ext. corner- and int. corner flashings 161-179. Eave flashings 181-194. Window- and door flashings 195-199. Flashings used in uplifted roofs FASTENERS 201. Self-drilling panel fastening screw, washer with sealing 202. Self-drilling panel fastening screw, countersink washer 205. Self-drilling panel fastening screw/roof fastener screw 211. Self-threading panel fastening screw, washer with sealing 212. Self-threading panel fastening screw, countersink washer 221. Internal thread socket +hex bolt (for vemo-fastenings) 231. Flashing fastener, washer with sealing 232. Flashing fastener (without washer) 234. Flat cup head screw 235. J oint panel fastener RST 241. Fastener screw, washer with sealing 242. Fastener screw (without washer) 251. Spike-panel fastener, washer with sealing 255. Spike-fastener (without washer) 261. Self-drilling panel fastening screw for wood, washer with sealing 262. Self-drilling panel fastening screw for wood, countersink washer 265. Fastener screw for wood, washer with sealing 271. Rivet SEALANTS AND INSULATIONS 300. Plinth sealing (SPA80-230) 301. Expandable sealing band 302. Sealing band, flashings 303. Sealing band 305. Butyl rubber seal 306. Butyl plinth sealing 307. Sealing tape 310. Mineral-/stonewool 311. Mineral wool 312. Mineral wool 321. Sealant 322. Sealant, if necessary 325. Sealant to male groove >200mm in length 326. Sealant to male groove 327. Elastic polyurethane, eg. Illbruck FM330 tai FM637 331. Elastic groove joint sealant (installed in the factory) 341. Plywood Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY Accessory numbers in details . SPA00-ENERGY-0E-EN . 15.06.2011 Ruukki 1:Z 10.06.2013 C SPA00-ENERGY-0E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. 100 - 3 0 + 1 341 111 301 131 306 111 301. /EA3SPBSK___/ Expandable sealing band 001. Sandwich panel SPA ENERGY, horizontal installation 131. /EA1J V1/ Vertical joint flashing 111. /EA1P3-___/ Cill flashing (installed simultaneously with SPA) 100. /EA1U___/ Starter track 312. /EAWS___/ Mineral wool Ruukki's delivery 341. Plywood, if necessary 265 1:1 255. Spike-fastener, concrete c/c600 265. Fastener, wood c/c600 or 312 255 >40 4 8 322. /EA3SM310___/ Sealant, if necessary Sealant, installed in the factory Special care should be taken to ensure the smoothness of the top of plinth 1:4 SPA01-ENERGY-1E-EN.DWG 15.06.2011 10.06.2013 C Ruukki . Date Scale Drawn by File nr. Building Work nr. Contents of drawing Drawing nr. Rev. date Rev. Rev. . SPA01-ENERGY-1E-EN Sandwich panel SPA ENERGY, horizontal installation Plinth, vertical section, Option 1 Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Sealant, installed in the factory 111 322 306. /EA3SPB07___/ Butyl plinth sealing 306 Drain holes in the corner of starter track 12 c/c 300 001. Sandwich panel SPA ENERGY, horizontal installation 134. /EA1J V10-11/ Vertical joint panel 112. /EA1P1-___/ Cill flashing (can be 100. /EA1U___/ Starter track Ruukki's delivery 112 100 3 0 1 112 301 265 1:1 301. /EA3SPBSK___/ Expandable sealing band 312. /EAWS___/ Mineral wool - + 231. Fastener for flashing, washer with sealing 312 255 231 134 4 8 Sealant during installation >40 322. /EA3SM310___/ Sealant, if necessary 321 Seam between vertical seam, and corner rain screen panel: 134 134 1:2 134 149 149 149. /EA1SF1/ Rain screen panel starting fillet 321. /EA3SM310___/ Sealant Air hole 2 235 235 235. J oint panel fastener, stainless steel, washer with sealing 1:4 SPA01-ENERGY-2E-EN.DWG 15.06.2011 10.06.2013 C Ruukki . . Date Building Contents of drawing Rev. Scale Drawn by File nr. Work nr. Drawing nr. Rev. date Rev. SPA01-ENERGY-2E-EN Sandwich panel SPA ENERGY, horizontal installation Plinth, vertical section, Option 2 Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. 255. Spike-fastener, concrete c/c600 265. Fastener, wood c/c600 or installed after SPA installation) Sealant, installed in the factory Sealant, installed in the factory Special care should be taken to ensure the smoothness of the top of plinth 306 322 306. /EA3SPB07___/ Butyl plinth sealing Drain holes in the corner of starter track 12 c/c 300 306 113. /EA1PS/ Support flashing (installed simultaneously with SPA) 231. Fastener for flashing, washer with sealing 112. /EA1P1-___/ Cill flashing (can be installed after SPA installation) 100 3 0 1 113 301 322 265 112 1:1 001. Sandwich panel SPA ENERGY, horizontal installation 100. /EA1U___/ Starter track 301. /EA3SPBSK___/ Expandable sealing band 312. /EAWS___/ Mineral wool 131. /EA1J V1/ Vertical joint flashing - + Ruukki's delivery 112 113 231 312 255 131 322. /EA3SM310___/ Sealant, if necessary 4 8 >40 Contents of drawing 1:4 SPA01-ENERGY-3E-EN.DWG 15.06.2011 10.06.2013 C Ruukki . . Date Building Rev. Scale Drawn by File nr. Work nr. Drawing nr. Rev. date Rev. SPA01-ENERGY-3E-EN Sandwich panel SPA ENERGY, horizontal installation Plinth, vertical section, Option 3 Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. 255. Spike-fastener, concrete c/c600 265. Fastener, wood c/c600 or Sealant, installed in the factory Sealant, installed in the factory 306 Special care should be taken to ensure the smoothness of the top of plinth 306. /EA3SPB07___/ Butyl plinth sealing Drain holes in the corner of starter track 12 c/c 300 306 133. /EA1J V9/ Vertical joint flashing 111. /EA1P3-___/ Cill flashing (installed simultaneously with SPA) Ruukki's delivery 114. Support flashing, L200 c/c1000, according to project 114 111 100 3 0 1 301 322 265 114 255 001. Sandwich panel SPA ENERGY, horizontal installation 100. /EA1U___/ Starter track 301. /EA3SPBSK___/ Expandable sealing band 312. /EAWS___/ Mineral wool - + 1:1 312 255 (installed simultaneously with SPA) 133 * * 111 322. /EA3SM310___/ Sealant, if necessary The vertical joint flashing must be cut, folded and sealed so that a bottom lip is created so that water cannot transfer into the stater track 4 8 >40 1:4 SPA01-ENERGY-4E-EN.DWG 15.06.2011 10.06.2013 C Ruukki . . Date Building Rev. Scale Drawn by File nr. Work nr. Drawing nr. Rev. date Rev. SPA01-ENERGY-4E-EN Sandwich panel SPA ENERGY, horizontal installation Plinth, vertical section, Option 4 Contents of drawing Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. 255. Spike-fastener, concrete c/c600 265. Fastener, wood c/c600 or Sealant, installed in the factory Sealant, installed in the factory Special care should be taken to ensure the smoothness of the top of plinth 306 306. /EA3SPB07___/ Butyl plinth sealing Drain holes in the corner of starter track 12 c/c 300 306 231. Fastener for flashing, washer with sealing Ruukki's delivery 100 301 115 321 302 231 231 1 322 131 115. Cill flashing, according to project (can be installed after SPA installation) 302. /EA3SS410/ Sealing band 115 265 - + 001. Sandwich panel SPA ENERGY, horizontal installation 100. /EA1W___/ Purlin 301. /EA3SPBSK___/ Expandable sealing band 312. /EAWS___/ Mineral wool 234. Flat headed screw 131. /EA1J V1/ Vertical joint flashing 312 255 1:1 321 306 1:1 322. /EA3SM310___/ Sealant, if necessary Sealant after installation Sealant after installation 4 8 >40 302 321. /EA3SM310___/ Sealant Contents of drawing 1:4 SPA01-ENERGY-5E-EN.DWG 15.06.2011 10.06.2013 C Ruukki . . Date Building Rev. Scale Drawn by File nr. Work nr. Drawing nr. Rev. date Rev. SPA01-ENERGY-5E-EN Sandwich panel SPA ENERGY, horizontal installation Plinth, vertical section, Starting with cut panel Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. 255. Spike-fastener, concrete c/c600 265. Fastener, wood c/c600 or Special care should be taken to ensure the smoothness of the top of plinth 234 306. /EA3SPB07___/ Butyl plinth sealing 306 Drain holes in the corner of purlin 12 c/c 300 301 115 321 302 201 - 131 114 > 3 0 105 255 231 255 001. Sandwich panel SPA, vertical- and horizontal installation 255. Spike-fastener, concrete c/c600 231. Fastener for flashing, washer with sealing 201. Self-drilling panel screw, washer with sealing 115. Cill flashing, according to project (can be installed after SPA installation) + 115 114. Support flashing, L200 c/c1000, according to project 105 131. /EA1J V1/ Vertical joint flashing 302. /EA3SS410/ Sealing band 301. /EA3SPBSK___/ Expandable sealing band Ruukki's delivery 105. /EA1L75/ Support L-purlin, (t=3mm) 1 75 75 Holes c/c600 325 1:1 116 116. Protective flashing, according to project (installed simultaneously with SPA) 116 117. Cover flashing, according to project 234. Flat cup head screw Screw drilling tip can be cut off after panel installation 4 8 >40 322. /EA3SM310___/ Sealant, if necessary 117 321. /EA3SM310___/ Sealant 114 302 234 (installed simultaneously with SPA) 302 322 325. /EA3SM310___/ Sealant to male groove, during installation Sealant to male groove 60mm in length on the inside Contents of drawing 1:4 SPA01-ENERGY-6E-EN.DWG 15.06.2011 04.06.2012 B Ruukki . . Date Building Rev. Scale Drawn by File nr. Work nr. Drawing nr. Rev. date Rev. SPA01-ENERGY-6E-EN Sandwich panel SPA ENERGY, vertical- and horizontal installation Plinth, vertical section . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Sealant after installation Special care should be taken to ensure the smooth- ness of the top of plinth 234 306 306. /EA3SPB07___/ Butyl plinth sealing 001. Sandwich panel SPA ENERGY, horizontal installation Ruukki's delivery - 1 1 + Elastic sealing strip is installed in the inner groove joint as a standard in the factory Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation J oint between panels, vertical section . SPA02-ENERGY-1E-EN . 15.06.2011 Ruukki 1:2 04.06.2012 B SPA02-ENERGY-1E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Elastic sealing strip is installed in the outer groove joint as a standard in the factory 001. Sandwich panel SPA, vertical and diagonal installation + 1 1 326 - Ruukki's delivery 326. /EA3SM310___/ Sealant to male groove, during installation Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, vertical- and horizontal installation J oint between panels, horizontal section . SPA02-ENERGY-2E-EN . 15.06.2011 Ruukki 1:2 04.06.2012 B SPA02-ENERGY-2E-EN.dwg . Elastic sealing strip is installed in the inner groove joint as a standard in the factory Elastic sealing strip is installed in the outer groove joint as a standard in the factory Sealant during installation 131. /EA1J V1/ Vertical joint flashing 231. Fastener for flashing, washer with sealing 201. Self-drilling panel screw, washer with sealing 001. Sandwich panel SPA ENERGY, horizontal installation Ruukki's delivery 20 + - 325. /EA3SM310___/ Sealant to male groove >200mm in length 325 min 200mm min 200mm 1 131 312 201 307 307. /EA3J S7050/ Sealing tape 302. /EA3SS410/ Sealing band 312. /EAWS___/ Mineral wool 302 1 Sealant (installed in the factory) Self-drilling panel screw, max. drilling capacity varies by screw type (10-14mm) 325 231 on the outside 327. Elastic polyurethane SPA03-ENERGY-1E-EN.DWG . 19.08.2013 1:2.5 D 15.06.2011 . Sandwich panel SPA ENERGY, horizontal installation, Vertical joint, horizontal section Rectangle hollow section column, option 1 SPA03-ENERGY-1E-EN Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Ruukki Sealant during installation >50 >30 303 327 303. /EA3SS1210/ Sealing band 132. /EA1J VB3/ Vertical joint bottom flashing 231. Fastener for flashing, washer with sealing 212. Self-threading panel screw, countersink washer 001. Sandwich panel SPA ENERGY, horizontal installation + - 1 303 Self-threading panel screw when material is thick (>10-14mm), requires pre-drilled holes Note! Optional way is to pre-drill the material enough to be able to continue with self-drilling screws. Screw drilling tip can be cut off after panel installation Requires pre- 231 40 212 133 271 307 132 271. Rivet 325 ~35 302 133. /EA1J V9/ Vertical joint flashing 307. /EA3J S7050/ Sealing tape 302. /EA3SS410/ Sealing band 312. /EAWS___/ Mineral wool min 200mm min 200mm 325 325. /EA3SM310___/ Sealant to male groove >200mm in length on the 312 Vertical joint bottom flashing joints must be sealed properly! holes 27mm 1 outside Ruukki's delivery 327. Elastic polyurethane SPA03-ENERGY-2E-EN.DWG . 19.08.2013 1:2.5 D 15.06.2011 . Sandwich panel SPA ENERGY, horizontal installation, Vertical joint, horizontal section I-steel profile, option 2 SPA03-ENERGY-2E-EN Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Ruukki Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Sealant (installed in the factory) Sealant during installation joints must be sealed waterproof) 303. /EA3SS1210/ Sealing band 327 134. /EA1J V10-11/ Vertical joint panel (h=600 or 1200) 235. J oint panel fastener RST, washer with sealing 201. Self-drilling panel screw, washer with sealing 001. Sandwich panel SPA ENERGY, horizontal installation 20 + - 325. /EA3SM310___/ Sealant to male groove >200mm in length 325 min 200mm min 200mm 1 312 201 307. /EA3J S7050/ Sealing tape 302. /EA3SS410/ Sealing band 312. /EAWS___/ Mineral wool 302 1 Self-drilling panel screw, max. drilling capacity varies by screw type (1,5-14mm) 325 134 307 Vertical seam from front: e f f .
w i d t h
1 2 0 0 e f f .
w i d t h
1 2 0 0 250 6 0 0 1:15 235 6 0 0 1 2 0 0 on the outside Ruukki's delivery 327. Elastic polyurethane SPA03-ENERGY-3E-EN.DWG . 19.08.2013 1:2.5 D 15.06.2011 . Sandwich panel SPA ENERGY, horizontal installation, Vertical joint, horizontal section Rectangle hollow section column, option 3 SPA03-ENERGY-3E-EN Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Ruukki Sealant (installed in the factory) Sealant during installation 303. /EA3SS1210/ Sealing band >30 303 327 >50 135. /EA1J V4/ Vertical joint flashing 231. Fastener for flashing, washer with sealing 001. Sandwich panel SPA ENERGY, horizontal installation 20 1 min 200mm min 200mm 1 303 135 148 307 312 307. /EA3J S7050/ Sealing tape 148. /EA1VCO/ Vertical cover flashing 251. Spike panel fastener, washer with sealing 312. /EAWS___/ Mineral wool 325. /EA3SM310___/ Sealant to male groove >200mm in length 303. /EA3SS1012/ Sealing band, concrete >30 251 . + - 231 325 325 Sealant is installed under the flashing before installation Remember that under vertical flashing EA1J V4 head to head joints there must be butt strap EA1J VJ P on the outside >50 Ruukki's delivery 327. Elastic polyurethane SPA03-ENERGY-4E-EN.DWG . 19.08.2013 1:2.5 D 15.06.2011 . Sandwich panel SPA ENERGY, horizontal installation, Vertical joint, horizontal section Concrete column, option 4 SPA03-ENERGY-4E-EN Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Ruukki Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Sealant (installed in the factory) Sealant during installation 327 231. Fastener for flashing, washer with sealing 001. Sandwich panel SPA ENERGY, horizontal installation + - min 200mm min 200mm 1 231 302. /EA3SS410/ Sealing band 312. /EAWS___/ Mineral wool 137 262 302 325 40 262. Self-drilling panel screw for wood, countersink washer 136 148 271 312 148. /EA1VCO/ Vertical cover flashing 136. /EA1J V7/ Vertical joint flashing 137. /EA1J VB2/ Vertical joint bottom flashing 271. Rivet . 307 307. /EA3J S7050/ Sealing tape 325 1 Requires pre- holes 27mm groove >200mm in length on the Vertical joint bottom flashing joints must be sealed properly! outside 325. /EA3SM310___/ Sealant to male 327. Elastic polyurethane Ruukki's delivery SPA03-ENERGY-5E-EN.DWG . 19.08.2013 1:2.5 D 15.06.2011 . Sandwich panel SPA ENERGY, horizontal installation, Vertical joint, horizontal section Laminated timber column, option 5 SPA03-ENERGY-5E-EN Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Ruukki Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Sealant (installed in the factory) Sealant during installation 303. /EA3SS1210/ Sealing band 303 ~35 >50 327 138. /EA1J V2/ Vertical joint flashing 231. Fastener for flashing, washer with sealing 221. Internal thread socket +hex bolt 001. Sandwich panel SPA ENERGY, horizontal installation Ruukki's delivery + - min 200mm min 200mm 1 138 ~40 312 221 121 325. /EA3SM310___/ Sealant to male groove >200mm in length 307. /EA3J S7050/ Sealing tape 302. /EA3SS410/ Sealing band 312. /EAWS___/ Mineral wool 325 121. /EA6FP_/ Fastening plate . 307 1 325 Concrete casting is made in the factory or for a construction site related reason made at site, before the SPA panel installation 302 231 231 on the outside Every 5th panel vertically and panels above an opening must be fixed to support by fasteners going through the panel 327. Elastic polyurethane SPA03-ENERGY-6E-EN.DWG . 19.08.2013 1:2.5 D 15.06.2011 . Sandwich panel SPA ENERGY, horizontal installation, Vertical joint, horizontal section Vemu-fastening, option 6 SPA03-ENERGY-6E-EN Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Ruukki Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Sealant (installed in the factory) Sealant during installation 303. /EA3SS1210/ Sealing band 303 327 139. /EA1J V3/ Vertical joint flashing 231. Fastener for flashing, washer with sealing 201. Self-drilling panel screw, washer with sealing 001. Sandwich panel SPA ENERGY, horizontal installation Ruukki's delivery >50 30 >30 + - 325. /EA3SM310___/ Sealant to male groove >200mm in length 325 min 200mm min 200mm 1 231 312 201 307 307. /EA3J S7050/ Sealing tape . 302. /EA3SS410/ Sealing band 312. /EAWS___/ Mineral wool 302 1 325 Secondary steel supports for SPA panels according to structural designer The structures on the side of the roof are displayed in the parapet details Screw drilling tip can be cut off after panel installation 139 on the outside 327. Elastic polyurethane SPA03-ENERGY-7E-EN.DWG . 19.08.2012 1:2.5 C 15.06.2011 . Sandwich panel SPA ENERGY, horizontal installation, Vertical joint, horizontal section T-steel, parapet, option 7 SPA03-ENERGY-7E-EN Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Ruukki Sealant during installation Sealant (installed in the factory) 303. /EA3SS1210/ Sealing band 303 327 Ruukki's delivery 001. Sandwich panel SPA ENERGY, horizontal installation 201. Self-drilling panel screw, washer with sealing 141. /EA1EC1-3/ External corner flashing, recommended SPA thickness class <150mm 146. /EA1EC9-___/ External corner flashing 231. Fastener for flashing, washer with sealing 312. /EAWS___/ Mineral wool 325. /EA3SM310___/ Sealant to male groove >200mm in length 302. /EA3SS410/ Sealing band Self-drilling panel screw, max. drilling capacity varies by screw type (1,5-14mm) Facing sheet cut on site by length b=SPA thickness on the outside 327. Elastic polyurethane SPA04-ENERGY-1E-EN.DWG . 19.08.2013 1:2.5 D 15.06.2011 Sandwich panel SPA ENERGY, horizontal installation, External corner, horizontal section Rectangle hollow section column, option 1 SPA04-ENERGY-1E-EN Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Ruukki Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Sealant during installation Sealant (installed in the factory) 20 303 201 231 312 302 1 >30 141 + - min 200mm m i n
2 0 0 m m 231 b 325 325 146 146 1 327 303. /EA3SS1210/ Sealing band 001. Sandwich panel SPA ENERGY, horizontal installation 231. Fastener for flashing, washer with sealing 201. Self-drilling panel screw, washer with sealing 145. /EA1EC10-___/ Cover flashing, t=1mm/1.2mm, (limited range of colours) 131. /EA1J V1/ Vertical joint flashing Ruukki's delivery 312. /EAWS___/ Mineral wool 325. /EA3SM310___/ Sealant to male groove >200mm in length on the outside 302. /EA3SS410/ Sealing band 211. Self-threading panel screw, washer with sealing Self-threading panel screw when material is thick (>10-14mm), requires pre-drilled holes Note! Optional way is to pre-drill the material enough to be able to continue with self-drilling screws Self-drilling panel screw, max. drilling capacity varies by screw type (1,5-14mm) 327. Elastic polyurethane SPA04-ENERGY-2E-EN.DWG . 19.08.2013 1:2.5 D 15.06.2011 Sandwich panel SPA ENERGY, horizontal installation, External corner, horizontal section I-steel profile, option 2 SPA04-ENERGY-2E-EN Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Ruukki Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Sealant during installation Facing sheet cut on site by length b=SPA thickness Sealant (installed in the factory) 20 303 325 >30 + - min 200mm m i n
2 0 0 m m b 325 312 231 <10 302 1 145 231 211 201 1 145 131 327 303. /EA3SS1210/ Sealing band 20 303 1 001. Sandwich panel SPA ENERGY, horizontal installation + - min 200mm m i n
2 0 0 m m b 142. /EA1EC11-12/ External corner panel 325 312 231 146 251. Spike panel fastener, washer with sealing 231. Fastener for flashing, washer with sealing 312. /EAWS___/ Mineral wool 325. /EA3SM310___/ Sealant to male groove >200mm in length on the outside 302. /EA3SS410/ Sealing band >50 1 142 251 325 146 321 321 321. /EA3SM310___/ Sealant 302 235 146. /EA1EC9-___/ External corner flashing, t=0.6mm 303. /EA3SS1012/ Sealing band, concrete >50 235. J oint panel fastener, stainless steel, washer with sealing 327 327. Elastic polyurethane Ruukki's delivery SPA04-ENERGY-3E-EN.DWG . 19.08.2013 1:2.5 D 15.06.2011 Sandwich panel SPA ENERGY, horizontal installation, External corner, horizontal section Concrete column, option 3 SPA04-ENERGY-3E-EN Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Ruukki Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Sealant (installed in the factory) Sealant during installation Facing sheet cut on site by length b=SPA thickness Sealant during installation 20 303 1 + - min 200mm m i n
2 0 0 m m b 325 312 231 146 >50 1 142 251 325 146 321 321 302 235 >50 327 Ruukki's delivery 001. Sandwich panel SPA ENERGY, horizontal installation 148. /EA1VCO/ Vertical cover flashing 146. /EA1EC9-___/ External corner flashing 231. Fastener for flashing, washer with sealing 312. /EAWS___/ Mineral wool 302. /EA3SS410/ Sealing band 201. Self-drilling panel screw, washer with sealing 143. /EA1EC5/ External corner flashing, recommended SPA thicknes class <150mm Sealant under the flashing, during installation Remember that under external corner flashing EA1EC5 butt joints there must be butt strap EA1CJ P1 on the outside 325. /EA3SM310___/ Sealant to male groove >200mm in length 327. Elastic polyurethane SPA04-ENERGY-4E-EN.DWG . 19.08.2013 1:2.5 D 15.06.2011 Sandwich panel SPA ENERGY, horizontal installation, External corner, horizontal section Rectangle hollow section column, option 4 SPA04-ENERGY-4E-EN Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Ruukki Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Sealant during installation Facing sheet cut on site by length b=SPA thickness Sealant under the flashing, during installation Sealant (installed in the factory) 20 303 201 231 312 >30 143 + - min 200mm 325 m i n
2 0 0 m m 231 b 148 146 325 146 1 327 303. /EA3SS1210/ Sealing band 135. /EA1J V4/ Vertical joint flashing 001. Sandwich panel SPA ENERGY, horizontal installation 148. /EA1VCO/ Vertical cover flashing 145. /EA1EC10-___/ Cover flashing, t=1mm/1.2mm, (limited range of colours) 231. Fastener for flashing, washer with sealing 312. /EAWS___/ Mineral wool 325. /EA3SM310___/ Sealant to male groove >200mm in length on the outside 303. /EA3SS1210/ Sealing band 261. Self-drilling panel screw for wood, washer with sealing Ruukki's delivery Remember that under vertical flashing EA1J V4 butt joints there must be butt strap EA1J VJ P 327. Elastic polyurethane SPA04-ENERGY-5E-EN.DWG . 19.08.2013 1:2.5 D 15.06.2011 Sandwich panel SPA ENERGY, horizontal installation, External corner, horizontal section Laminated timber column, option 5 SPA04-ENERGY-5E-EN Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Ruukki Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Sealant (installed in the factory) Sealant during installation Facing sheet cut on site by length b=SPA thickness Sealant under the flashing, during installation 20 1 >30 + - m i n
2 0 0 m m b 325 312 135 148 231 261 303 145 135 325 1 145 Tiivistysmassa listan alle, asennuksen yhteydess 231 >50 327 Sealant (installed in the factory) Sealant during installation Facing sheet cut on site by length b=SPA thickness 138. /EA1J V2/ Vertical joint flashing 231. Fastener for flashing, washer with sealing 221. Internal thread socket +hex bolt 001. Sandwich panel SPA ENERGY, horizontal installation Ruukki's delivery 325. /EA3SM310___/ Sealant to male groove >200mm 302. /EA3SS410/ Sealing band 312. /EAWS___/ Mineral wool 121. /EA6FP_/ Fastening plate 145. /EA1EC10-___/ Cover flashing, t=1mm/1.2mm, Concrete casting is made in the factory or for a construction site related reason made at site, before the SPA panel installation Every 5th panel vertically and panels above an opening must be fixed to support by fasteners going through the panel Holes made to panel on site in length on the outside 327. Elastic polyurethane Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, External corner, horizontal section Concrete filled column, option 6 SPA04-ENERGY-6E-EN . 15.06.2011 Ruukki 1:3 19.08.2013 D SPA04-ENERGY-6E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. (limited range of colours) Holes made to panel on site 303. /EA3SS1210/ Sealing band 325 + - min 200mm 312 231 1 1 138 145 221 231 303 325 20 m i n
2 0 0 m m 121 231 302 145 b 327 327 325 + - min 200mm 312 231 1 1 138 145 221 231 303 325 20 m i n
2 0 0 m m 121 231 302 145 b 327 327 001. Sandwich panel SPA ENERGY, horizontal installation 002. Sandwich panel SPA ENERGY corner panel, for example 350x350 (SPA 80-200: min. ext. dimension 300mm, 132. /EA1J VB3/ Vertical joint bottom flashing 231. Fastener for flashing, washer with sealing 202. Self-drilling panel screw, countersink washer Ruukki's delivery 271. Rivet 133. /EA1J V9/ Vertical joint flashing 307. /EA3J S7050/ Sealing tape 302. /EA3SS410/ Sealing band 312. /EAWS___/ Mineral wool 325. /EA3SM310___/ Sealant to male groove >200mm in length on the outside during installation Requires pre- Vertical joint bottom flashing joints must be sealed properly! max. 2400mm;SPA 230: min. ext. dimension 350mm, max. 2400mm) holes 27mm Sealant (installed in the factory) 327. Elastic polyurethane Date Scale Drawn by Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, External corner, horizontal section SPA corner panel, option 7 SPA04-ENERGY-7E-EN . 15.06.2011 Ruukki 1:4 19.08.2013 D SPA04-ENERGY-7E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. 303. /EA3SS1210/ Sealing band 133 325 303 303 ~35 40 4 0 231 302 1 271 202 312 132 2 307 1 325 min 200mm min 200mm e.g. 350 e . g .
3 5 0 m i n
2 0 0 m m m i n
2 0 0 m m 327 327 Sealant 001. Sandwich panel SPA ENERGY, horizontal installation 002. Sandwich panel SPA ENERGY corner panel, for example 350x350 148. /EA1VCO/ Vertical cover flashing 231. Fastener for flashing, washer with sealing 202. Self-drilling panel screw, countersink washer Ruukki's delivery 271. Rivet 136. /EA1J V7/ Vertical joint flashing 302. /EA3SS410/ Sealing band 312. /EAWS___/ Mineral wool 325. /EA3SM310___/ Sealant to male groove >200mm in length on the outside 137. /EA1J VB2/ Vertical joint bottom flashing Panels must be installed (SPA 80-200: min. ext. dimension 300mm, max. 2400mm;SPA 230: min. ext. dimension 350mm, max. 2400mm) 307. /EA3J S7050/ Sealing tape before concrete casting! e . g .
3 5 0 327. Elastic polyurethane Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Date Scale Drawn by Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, External corner, horizontal section SPA corner panel, option 8 SPA04-ENERGY-8E-EN . 15.06.2011 Ruukki 1:4 19.08.2013 D SPA04-ENERGY-8E-EN.dwg . Sealant (installed in the factory) Sealant during installation 303. /EA3SS1210/ Sealing band 325 303 303 ~35 40 4 0 302 1 312 2 202 325 137 136 271 307 231 148 1 min 200mm min 200mm m i n
2 0 0 m m m i n
2 0 0 m m 327 e.g. 350 Requires pre- Vertical joint bottom flashing joints must be sealed properly! holes 27mm 325 + - b 325 312 139 302 1 145 231 201 201 1 Secondary steel supports for SPA panels according to structural designer The structures on the side of the roof are displayed in the parapet details min 200mm 001. Sandwich panel SPA ENERGY, horizontal installation 231. Fastener for flashing, washer with sealing 201. Self-drilling panel screw, washer with sealing 145. /EA1EC10-___/ Cover flashing, t=1mm/1.2mm, (limited variation of colours) 139. /EA1J V3/ Vertical joint flashing Ruukki's delivery 312. /EAWS___/ Mineral wool 325. /EA3SM310___/ Sealant to male groove >200mm in length 302. /EA3SS410/ Sealing band m i n
2 0 0 m m 139 Screw drilling tip can be cut off after panel installation 20 30 145 231 327. Elastic polyurethane on the outside Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, External corner, horizontal section L-steel, parapet, option 9 SPA04-ENERGY-9E-EN . 15.06.2011 Ruukki 1:3 19.08.2013 D SPA04-ENERGY-9E-EN.dwg . . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Facing sheet cut on site by length b=SPA thickness Sealant (installed in the factory) Sealant during installation 303. /EA3SS1210/ Sealing band 303 327 Ruukki's delivery 001. Sandwich panel SPA ENERGY, Installed first 151. /EA1IC3/ Internal corner flashing 231. Fastener for flashing, washer with sealing 201. Self-drilling panel screw, washer with sealing 312. /EAWS___/ Mineral wool 325. /EA3SM310___/ Sealant to male groove >200mm in length on the outside 302. /EA3SS410/ Sealing band 307. /EA3J S7050/ Sealing tape Screw drilling tip can be cut off after panel installation If necessary 234. Flat headed screw 242. Fastener 152. Internal corner flashing, If necessary horizontal installation 327. Elastic polyurethane Date Scale Drawn by Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, Internal corner, horizontal section Rectangle hollow section column, option 1 SPA05-ENERGY-1E-EN . 15.06.2011 Ruukki 1:4 19.08.2013 D SPA05-ENERGY-1E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Sealant (installed in the factory) Sealant during installation + - > 3 0 >30 > 5 0 20 min 200mm m i n
2 0 0 m m 312 312 201 151 1 231 302 1 303 325 325 307 242 234 151 152 242 234 327 327 according to project 303. /EA3SS1210/ Sealing band Ruukki's delivery 148. /EA1VCO/ Vertical cover flashing 157. Cover flashing, t=0.6mm, according to project 156. /EA1IC9/ Internal corner flashing 242. Fastener 201. Self-drilling panel screw, washer with sealing 312. /EAWS___/ Mineral wool 325. /EA3SM310___/ Sealant to male groove >200mm in length on the outside 302. /EA3SS410/ Sealing band Installed first 231. Fastener for flashing, washer with sealing 234. Flat headed screw 307. /EA3J S7050/ Sealing tape Remember that under internal corner flashing EA1IC9 butt joints must be butt strap EA1CJ P2 Sealant under the flashing, during installation 146. /EA1EC9-___/ External corner flashing 001. Sandwich panel SPA ENERGY, horizontal installation 327. Elastic polyurethane Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Date Scale Drawn by Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, Internal corner, horizontal section Rectangle hollow section column, option 2 SPA05-ENERGY-2E-EN . 15.06.2011 Ruukki 1:4 19.08.2013 D SPA05-ENERGY-2E-EN.dwg . Sealant (installed in the factory) Sealant during installation 303. /EA3SS1210/ Sealing band + - 157 min 200mm m i n
2 0 0 m m 1 302 312 303 2 0 > 3 0 1 201 307 156 325 325 148 231 242 307 146 234 Ruukki's delivery 001. Sandwich panel SPA ENERGY, Installed first 153. /EA1IC8/ Internal corner flashing 231. Fastener for flashing, washer with sealing 201. Self-drilling panel screw, washer with sealing 312. /EAWS___/ Mineral wool 302. /EA3SS410/ Sealing band 307. /EA3J S7050/ Sealing tape The structures on the side of the roof are displayed in the parapet details 154. /EA1IC10/12 (left)/ Internal corner rain screen panel horizontal installation 155. /EA1IC11/13 (right)/ Internal corner rain screen panel are made on site Cuts for (201) fasteners 235. J oint panel fastener, stainless steel 327. Elastic polyurethane 325. /EA3SM310___/ Sealant to male groove >200mm in length on the outside Date Scale Drawn by Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, Internal corner, horizontal section L-steel, parapet, option 3 SPA05-ENERGY-3E-EN . 15.06.2011 Ruukki 1:4 19.08.2013 D SPA05-ENERGY-3E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Sealant (installed in the factory) Sealant during installation Screw drilling tip can be cut off after panel installation 303. /EA3SS1210/ Sealing band + - > 3 0 >30 > 5 0 20 min 200mm m i n
2 0 0 m m 312 312 201 155 1 302 235 1 303 325 325 153 307 153 154 154 155 235 231 327 327 Secondary steel supports for the SPA panels according to structural designer Reverse dip is made of Leca- 100. /EA1EP___/ Purlin 001. Sandwich panel SPA ENERGY, 131. /EA1J V1/ Vertical joint flashing 162. Protective flashing, t=0.6mm, acc. to project Ruukki's delivery 163. Storm flashing, t=0.6mm, according to project 171. Insulation support flashing, t=0.6 mm 161. Eave flashing, t=0.6mm, according to project 173. U-profile for vapour barrier fixing, t=0.6mm, acc. to order 232. Fastener for flashing X. Fastening of profiled sheet according to special designs 265. Fastener for wood, washer with sealing 302. /EA3SS410/ Sealing band, between SPA and vapour barrier Note! Profiled sheet installation is started up from eaves Supports of profiled sheet acc. to structural designer Insulation support flashing at SPA support, from above Vapour barrier movable joint 1:10 to structures below for L~400mm Waterproofing in not fastened Horizontal support Vertical support gravel, Siporex chips or wool- sheets cut to form T-steel Plywood Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, Parapet Side eaves, bitumen roofing felt, vertical section SPA06-ENERGY-1E-EN . 15.06.2011 Ruukki 1:7.5 10.06.2013 C SPA06-ENERGY-1E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. studwork studwork horizontal installation 131 1 X 171 171 171 171 265 232 161 265 163 162 1:5 162 302 173 161 315 100 100 163 161 232 + - 302 173 Insulation thickness is dimensioned Ventilation grooves according to project 100. /EA1EP___/ Purlin 001. Sandwich panel SPA ENERGY, 131. /EA1J V1/ Vertical joint flashing 163. Storm flashing, t=0.6mm, according to project 161. Eave flashing, t=0.6mm, according to project 232. Fastener for flashing 265. Fastener for wood, washer with sealing Vapour barrier movable joint 1:10 Plywood T-steel to structures below for L~400mm Waterproofing in not fastened 172. Insulation support flashing, t=0.6 mm 173. U-profile for vapour barrier fixing, t=0.6mm, acc. to order Secondary steel supports (T-steel) for the SPA panels according to structural designer Ruukki's delivery X. fastening of profiled sheet according to special designs 302. /EA3SS410/ Sealing band, between SPA and vapour barrier Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, Parapet End eaves, bitumen roofing felt, vertical section SPA06-ENERGY-2E-EN . 15.06.2011 Ruukki 1:7.5 10.06.2013 C SPA06-ENERGY-2E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Horizontal support studwork Vertical support studwork Insulation support flashing at SPA support, from above horizontal installation 1 172 150 100 161 265 232 1:5 100 173 232 163 161 172 172 172 131 163 X + - 302 173 302 100. /EA1EP___/ Purlin 001. Sandwich panel SPA ENERGY, vertical and diagonal 162. Protective flashing, t=0.6mm, acc. to project Ruukki's delivery 163. Storm flashing, t=0.6mm, according to project 103. Flashing for fastening/insulation support flashing, 161. Eave flashing, t=0.6mm, according to project 173. U-profile for vapour barrier fixing, t=0.6mm, acc. to order 242. Fastener X. Fastening of profiled sheet 265. Fastener for wood, washer with sealing 302. /EA3SS410/ Sealing band Note! Profiled sheet installation is started up from eaves Supports of profiled sheet acc. to structural designer Vapour barrier movable joint Plywood 201. Self-drilling panel screw, washer with sealing 231. Fastener for flashing, washer with sealing 179. Cover flashing, t=0.6mm, according to project 232. Fastener for flashing according to special designs Sealant in outer male groove, full length of SPA Sealant in inner male groove, 60mm length. Sealing band between SPA and vapour barrier. Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, vertical and diagonal installation, Parapet Side eaves, bitumen roofing felt, vertical section SPA06-ENERGY-3E-EN . 15.06.2011 Ruukki 1:7.5 10.06.2013 C SPA06-ENERGY-3E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. t=3 mm, according to project to structures below for L~400mm Waterproofing in not fastened Reverse dip is made of Leca- gravel, Siporex chips or wool- sheets cut to form Horizontal support studwork Vertical support studwork installation 1 X 103 103 265 311 161 265 163 162 1:5 162 302 161 163 161 232 173 242 179 201 231 302 1:2 242 + - 173 302 100 311. /EAWS30565/ Mineral wool Ruukki's delivery Ventilation grooves 100. /EA1EP___/ Purlin 001. Sandwich panel SPA ENERGY, vertical and diagonal 163. Storm flashing, t=0.6mm, according to project 161. Eave flashing, t=0.6mm, according to project 232. Fastener for flashing 265. Fastener for wood, washer with sealing Vapour barrier movable joint Plywood 104. Flashing for fastening/insulation support flashing, 173. U-profile for vapour barrier fixing, t=0.6mm, acc. to order 179. Cover flashing, t=0.6mm, according to project 201. Self-drilling panel screw, washer with sealing 231. Fastener for flashing, washer with sealing 242. Fastener, washer with sealing 302. /EA3SS410/ Sealing band Sealant in inner male groove, 60mm length. Sealing band between SPA and vapour barrier. Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, vertical and diagonal installation, Parapet SPA06-ENERGY-4E-EN . 15.06.2011 Ruukki 1:7.5 10.06.2013 C SPA06-ENERGY-4E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. End eaves, bitumen roofing felt, vertical section t=3mm, according to project X. Fastening of profiled sheet according to special designs to structures below for L~400mm Waterproofing in not fastened Horizontal support studwork Vertical support studwork Sealant in outer male groove, full length of SPA Insulation thickness is dimen- sioned according to project installation 311. /EAWS30565/ Mineral wool 1 104 161 265 232 1:5 232 163 104 163 X 179 201 231 161 242 302 1:2 302 311 + - 173 173 302 100 1 232 131 171 311 173 232 Supports of profiled sheet according to structural designer Vapour barrier movable joint 100 315 171 164 101 171. Insulation support flashing, t=0.6 mm 131. /EA1J V1/ Vertical joint flashing 231. Fastener for flashing, washer with sealing 001. Sandwich panel SPA ENERGY, Ruukki's delivery 164. Eave flashing, t=0.6mm, according to project 101. Eave purlin, t=1.2mm, according to project 311. /EAWS30565/ Mineral wool X. Fastening of profiled sheet according to special designs 165. Storm flashing, t=0.6mm, according to project X 231 165 101 232. Fastener for flashing sealed with a flashing on Load bearing sheet 241. Fastener, washer with sealing 241 Water drainage system 125 both sides 231 165 164 treatment recommended Profiled sheet, anti-condence 125. /EA1HP1/ Ventilated hat purlin purlin 173. U-profile for vapour barrier fixing, t=0.6mm, acc. to order + - SPA panel is cut at the point where it intersects with the steel structure. Moisture barrier is taped around the steel. 302 173 302 302. /EA3SS410/ Sealing band, between SPA and vapour barrier Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal SPA06-ENERGY-5E-EN . 15.06.2011 Ruukki 1:7.5 04.06.2012 B SPA06-ENERGY-5E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Side eaves, bitumen roofing felt, vertical section horizontal installation installation 001. Sandwich panel SPA ENERGY, horizontal installation Ruukki's delivery 232 232 100 1 is dimensioned according to project Insulation thickness 173 131 172. Insulation support flashing, t=0.6 mm 131. /EA1J V1/ Vertical joint flashing 164. Eave flashing, t=0.6mm, according to project 100. /EA1D___/ Purlin 231. Fastener for flashing, washer with sealing 311. /EAWS30565/ Mineral wool 150 100 Vapour barrier movable joint 173 172 232. Fastener for flashing 164 164 Load bearing sheet sealed with a flashing on both sides 166. Storm flashing, t=0.6mm, according to project 205. Self-drilling panel screw / roofing screw 311 166 231 treatment recommended Profiled sheet, anti-condence 205 125 Sealing band, 172 recommended 241. Fastener X X. Fastening of profiled sheet according to special designs 125. /EA1HP1/ Ventilated hat purlin 311 + - 231 241 241 SPA panel is cut from the part where it intersects with the steel structure. Moisture barrier is taped around the steel. 302 302 173. U-profile for vapour barrier fixing, t=0.6mm, acc. to order 302. /EA3SS410/ Sealing band, between SPA and vapour barrier Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, Cantilever eaves gable eave section, profiled sheet roof deck SPA06-ENERGY-6E-EN . 15.06.2011 Ruukki 1:5 04.06.2012 B SPA06-ENERGY-6E-EN.dwg . 232 Perforated profiled sheet 1 171 100 311 173 232 131 171. Insulation support flashing, t=0.6 mm 131. /EA1J V1/ Vertical joint flashing 232. Fastener for flashing 001. Sandwich panel SPA ENERGY, Ruukki's delivery 167. Storm flashing, t=0.6mm, according to project 100. /EA1D___/ Purlin 311. /EAWS30565/ Mineral wool X. Profiled sheet fastening according to special designs Vapour barrier movable joint 100 315 171 173 Supports of profiled sheet acc. to structural designer 167 X Wooden wedge a flashing on both sides Load bearing sheet sealed with Plywood 173. U-profile for vapour barrier fixing, t=0.6mm, acc. to order Water drainage system + - SPA panel is cut from the part where it intersects with the steel structure. Moisture barrier is taped around the steel. flashing (164) if necessary (see detail SPA06-5) 302 302. /EA3SS410/ Sealing band, between SPA and vapour barrier 302 Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, Cantilever eaves Side eaves, bitumen roofing felt, vertical section SPA06-ENERGY-7E-EN . 15.06.2011 Ruukki 1:7.5 04.06.2012 B SPA06-ENERGY-7E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. horizontal installation 001. Sandwich panel SPA ENERGY, Ruukki's delivery 311 232 232 100 1 172 173 131 172. Insulation support flashing, t=0.6 mm 131. /EA1J V1/ Vertical joint flashing 168. Drip flashing, t=0.6mm, according to project 100. /EA1D___/ Door frame stud 173. U-profile for vapour barrier fixing, t=0.6mm, acc. to order 302. /EA3SS410/ Sealing band, between SPA and vapour barrier 150 100 Vapour barrier movable joint 172 grooves 232. Fastener for flashing triangular wood Plywood Eave flashing (164) if necessary (see SPA06-6) sealed with a flashing on both sides 265 265. Fastener for wood, washer with sealing X X. Fastening of profiled sheet according to special designs 168 + - 302 173 302 311. /EAWS30565/ Mineral wool Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, Cantilever eaves gable eave section, bitumen roofing felt SPA06-ENERGY-8E-EN . 15.06.2011 Ruukki 1:5 04.06.2012 B SPA06-ENERGY-8E-EN.dwg . Ventilation Insulation thickness is dimensioned according to project Load bearing sheet SPA panel is cut from the part where it intersects with the steel structure. Moisture barrier is taped around the steel. Impregnated horizontal installation 1 131 173. U-profile for vapour barrier fixing, t=0.6mm 131. /EA1J V1/ Vertical joint flashing 231. Fastener for flashing, washer with sealing 001. Sandwich panel SPA ENERGY, horiz. install. Ruukki's delivery 171. Insulation support flashing, t=0.6 mm 232. Fastener for flashing 174. Gutter flashing, t=0.6mm, according to project 206. Self-drilling panel screw / roofing screw X 173 171 232 169. Eave flashing, t=0.6mm, according to project 302. /EA3SS410/ Sealing band, between SPA and vapour barrier 315 100 Vapour barrier movable joint 171 102 241 169 designed according to project Gutters and it's brackets 241 176 102 174 102. Eave purlin, t=2mm, according to project 271 241. Fastener, washer with sealing 175. Cover flashing, t=0.6mm, according to project 125. /EA1HP1/ Ventilated hat purlin 201. Self-drilling panel screw, washer with sealing X. Fastening of profiled sheet 125 206 treatment recommended Profiled sheet, anti-condence 311 231 201 176 176. Storm flashing, t=0.6mm, according to project C-steel profile + - Supports of profiled sheet acc. to structural designer 175 302 173 302 according to special designs 311. /EAWS30565/ Mineral wool Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, Eaves Side eaves, profiled sheet roof deck SPA06-ENERGY-9E-EN . 15.06.2011 Ruukki 1:5 04.06.2012 B SPA06-ENERGY-9E-EN.dwg . 232 131. /EA1J V1/ Vertical joint flashing 001. Sandwich panel SPA ENERGY, horizontal installation Ruukki's delivery 177 1 131 232 is dimensioned according to project Insulation thickness 172 173 177. Eave flashing, t=0.6mm, according to project 173. U-profile for vapour barrier fixing, 172. Insulation support flashing, t=0.6 mm 231. Fastener for flashing, washer with sealing 302. /EA3SS410/ Sealing band, between SPA 100. /EA1D___/ Purlin 150 100 Vapour barrier movable joint 172 231 311 232. Fastener for flashing 205 100 205. Self-drilling panel screw / roofing screw 125. /EA1HP1/ Ventilated hat purlin 125 X treatment recommended Profiled sheet, anti-condence X. Fastening of profiled sheet according to special designs + - 302 173 302 311. /EAWS30565/ Mineral wool Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, Eaves gable eave section, profiled sheet roof deck SPA06-ENERGY-10E-EN . 15.06.2011 Ruukki 1:5 04.06.2012 B SPA06-ENERGY-10E-EN.dwg . t=0.6mm, acc. to order and vapour barrier 1 131 173. U-profile for vapour barrier fixing, 131. /EA1J V1/ Vertical joint flashing 232. Fastener for flashing 001. Sandwich panel SPA ENERGY, horizontal installation Ruukki's delivery 171. Insulation support flashing, t=0.6 mm 241. Fastener, washer with sealing 102. Eave purlin, t=2.0mm, according to project 311 169 201. Self-drilling panel screw, washer with sealing X Wooden wedge 171 232 169. Eave flashing, t=0.6mm, according to project 241 302. /EA3SS410/ Sealing band, between SPA X. Fastening of profiled sheet according to special designs 315 100 Vapour barrier movable joint 102 241 271 174 Plywood 171 102 174. Gutter, t=0.6mm, according to project 176 176. Drip flashing, t=0.6mm, according to project designed according to project Gutters and it's brackets 201 175 175. Cover flashing, t=0.6mm, according to project 271. Rivet + - Supports of profiled sheet acc. to structural designer 231 231. Fastener for flashing, washer with sealing 176 173 302 173 302 311. /EAWS30565/ Mineral wool Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, Eaves Side eaves, bitumen roofing felt SPA06-ENERGY-11E-EN . 15.06.2011 Ruukki 1:5 04.06.2012 B SPA06-ENERGY-11E-EN.dwg . t=0.6mm, acc. to order and vapour barrier 232 131. /EA1J V1/ Vertical joint flashing 001. Sandwich panel SPA ENERGY, horizontal installation Ruukki's delivery 1 131 232 is dimensioned according to project Insulation thickness 172 302 173. U-profile for vapour barrier fixing, 172. Insulation support flashing, t=0.6 mm 232. Fastener for flashing 265. Fastener for wood, washer with sealing 100. /EA1D___/ Purlin 150 100 Vapour barrier movable joint 172 Ventilation grooves Plywood Triangular wood 100 178. Eave flashing, t=0.6mm, according to project 205 205. Self-drilling panel screw / roofing screw X 302. /EA3SS410/ Sealing band, between SPA X. Fastening of profiled sheet according to special designs 311 231 178 231. Fastener for flashing, washer with sealing 265 + - 173 173 302 311. /EAWS30565/ Mineral wool Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, Eaves gable eave section, bitumen roofing felt SPA06-ENERGY-12E-EN . 15.06.2011 Ruukki 1:5 04.06.2012 B SPA06-ENERGY-12E-EN.dwg . t=0.6mm, acc. to order and vapour barrier 001. Sandwich panel SPA ENERGY, horiz. installation 171. Insulation support flashing, t=0.6 mm 265 173. U-profile for vapour barrier fixing, 195. Drip flashing, t=0.6mm, according to project 196. Support flashing, t=0.6mm, according to project 196 Ruukki's delivery 231 +- Waterproofing in not fastened to structures below for L~400mm t=0.6mm, acc. to order 231. Fastener for flashing, washer with sealing 232. Fastener for flashing 265. Fastener for wood, washer with sealing 302. /EA3SS410/ Sealing band 311. /EAWS30565/ Mineral wool X. Fastening of profiled sheet according to special designs 321. /EA3SM310___/ Sealant 197 302 173 171 X 321 Vertical support studwork 302 302 100 315 171 1 197. Protective flashing, t=0.6mm, according to project 195 231 Sealant after installation 311 302 173 302 Sealing between SPA and vapour barrier . 04.06.2012 1:5 B Ruukki 15.06.2011 . Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation Uplifted roofing, vertical section . SPA07-ENERGY-1E-EN SPA07-ENERGY-1E-EN.dwg Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Vapour barrier movable joint Ruukki's delivery 001. Sandwich panel SPA ENERGY, horizontal installation 231. Fastener for flashing, washer with sealing 181. Drip flashing, t=0.6mm, according to project 302. /EA3SS410/ Sealing band 321. /EA3SM310___/ Sealant Note! System window is installed during installation of SPA panels. during the installation with sealant >200mm in length on the outside. Note! Remember to seal the grooves of the SPA panels joining the window Note! Openings must be taken into account in dimensioning of SPA panels. Sealant during installation 181 System window fastening according to manufacturer recommendations + - 321 231 321 302 321 321 321 302 181 1 1 the factory) (installed in Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, System window, vertical section Small window SPA08-ENERGY-1E-EN . 15.06.2011 Ruukki 1:2.5 19.08.2013 C SPA08-ENERGY-1E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. 301. /EA3SPBSK___/ Expandable sealing band 301 301 301. /EA3SPBSK___/ Expandable sealing band 001. Sandwich panel SPA ENERGY, horizontal installation Ruukki's delivery during the installation with sealant >200mm in length on the outside. Note! Remember to seal the grooves of the SPA panels joining the window System window fastening according to manufacturer recommendations - + 321 1 321 1 321 321 (installed in Sealant the factory) Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, System window, horizontal section Small window SPA08-ENERGY-2E-EN . 15.06.2011 Ruukki 1:2.5 19.08.2013 C SPA08-ENERGY-2E-EN.dwg . Sealant during installation 321. /EA3SM310___/ Sealant 301 301 Note! System window is installed during installation of SPA panels. Note! Openings must be taken into account in dimensioning of SPA panels. 001. Sandwich panel SPA ENERGY, horizontal installation 183. Storm flashing, t=0.6mm, according to project 231. Fastener for flashing, washer with sealing 182. Drip flashing, t=0.6mm, according to project 201. Self-drilling panel screw, washer with sealing Ruukki's delivery Sealant during installation (installed in the factory) Sealant 302. /EA3SS410/ Sealing band Note! System window is installed during installation of SPA panels. during the installation with sealant >200mm in length on the outside. Note! Remember to seal the grooves of the SPA panels joining the window Note! Openings must be taken into account in dimensioning of SPA panels. System window fastening according to manufacturer recommendations 321. /EA3SM310___/ Sealant Supporting structures according to structural designer 184. Cover flashing, t=0.6mm, according to project Date Scale Drawn by Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, System window, vertical section Large window, supporting structure SPA08-ENERGY-3E-EN . 15.06.2011 Ruukki 1:4 19.08.0213 D SPA08-ENERGY-3E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. 301. /EA3SPBSK___/ Expandable sealing band 303. /EA3SS1210/ Sealing band > 5 0 303 302 302 182 201 321 1 321 > 5 0 302 201 231 184 303 1 - + 183 182 321 321 321 183 184 231 301 301 001. Sandwich panel SPA ENERGY, horizontal installation 185. Cover flashing, t=0.6mm, according to project Ruukki's delivery 231. Fastener for flashing, washer with sealing 201. Self-drilling panel screw, washer with sealing 302. /EA3SS410/ Sealing band during the installation with sealant >200mm in length on the outside. Note! Remember to seal the grooves of the SPA panels joining the window 321. /EA3SM310___/ Sealant Supporting structures according to structural designer System window fastening according to manufacturer recommendations Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Date Scale Drawn by Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, System window, horizontal section Large window, supporting structure SPA08-ENERGY-4E-EN . 15.06.2011 Ruukki 1:4 19.08.2013 D SPA08-ENERGY-4E-EN.dwg . Sealant during installation (installed in the factory) Sealant 301. /EA3SPBSK___/ Expandable sealing band Note! System window is installed during installation of SPA panels. Note! Openings must be taken into account in dimensioning of SPA panels. 303. /EA3SS1210/ Sealing band - + >50 185 201 231 1 321 302 >50 1 321 321 303 321 185 201 231 302 303 301 301 - 232 231 321 302 321 302 321 Ruukki's delivery 001. Sandwich panel SPA ENERGY, horiz. install. 231. Fastener for flashing, washer with sealing 181. Drip flashing, t=0.6mm, according to project Note! When thermal purlin (Window purlin, for example) is used around the opening, the thermal holes sealant >200mm in length on the outside. Note! Remember to seal the grooves of the SPA panels joining the window during the installation with Sealant during installation 181 187 234 100 321 231 + 301. /EA3SPBSK___/ Expandable sealing band 321. /EA3SM310___/ Sealant 181 234 186 in the purlin must be sealed with tape (aluminium tape, for example) from the inside of the purlin. 186 187 321 301 301 Supporting structures if necessary according to structural design (SPA08-3E) 100. /EA1W___/ Window purlin 100 186. Support-/ cover flashing, t=0.6mm 187. External window sill, t=0.6mm, acc. to project 234. Flat headed screw 302 231 232 1 1 302. /EA3SS410/ Sealing band 232. Fastener for flashing Sealant Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation Window, vertical section . SPA08-ENERGY-5E-EN . 15.06.2011 Ruukki 1:2.5 19.08.2013 C SPA08-ENERGY-5E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. (installed in the factory) Note! Openings must be taken into account in dimensioning of SPA panels. 302 321 188 100 231 321 302 321 188 100 231 321 Ruukki's delivery 001. Sandwich panel SPA ENERGY, horizontal installation 231. Fastener for flashing, washer with sealing 188. Cover flashing, t=0.6mm, according to project Note! When thermal purlin (Window purlin, for example) is used around the opening, the thermal holes sealant >200mm in length on the outside. Note! Remember to seal the grooves of the SPA panels joining the window during the installation with 301. /EA3SPBSK___/ Expandable sealing band 302. /EA3SS410/ Sealing band in the purlin must be sealed with tape (aluminium tape, for example) from the inside of the purlin. 1 1 + - Supporting structures if necessary according to structural design (SPA08-4E) 188 100. /EA1W___/ Window purlin 232. Fastener for flashing 234 234 231 231 232 232 301 301 321. /EA3SM310___/ Sealant 234. Flat headed screw (installed in the factory) Sealant Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation Window, horizontal section . SPA08-ENERGY-6E-EN . 15.06.2011 Ruukki 1:2.5 19.08.2013 C SPA08-ENERGY-6E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Sealant during installation Note! Openings must be taken into account in dimensioning of SPA panels. 001. Sandwich panel SPA ENERGY, horizontal installation 231. Fastener for flashing, washer with sealing 181. Drip flashing, t=0.6mm, according to project 302. /EA3SS410/ Sealing band 301. /EA3SPBSK___/ Expandable sealing band Note! System door is installed during installation of SPA panels. sealant >200mm in length on the outside. Note! Remember to seal the grooves of the SPA panels joining the door during the installation with System door fastening according to manufacturer recommendations 231 321 302 321 1 + - 181 321 302 301 321. /EA3SM310___/ Sealant Ruukki's delivery Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, System door, vertical section single door SPA09-ENERGY-1E-EN . 15.06.2011 Ruukki 1:2.5 19.08.2013 C SPA09-ENERGY-1E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. (installed in the factory) Sealant Sealant during installation Note! Openings must be taken into account in dimensioning of SPA panels. 001. Sandwich panel SPA ENERGY, horizontal installation sealant >200mm in length on the outside. Note! Remember to seal the grooves of the SPA panels joining the door during the installation with 321 1 321 + System door fastening according to manufacturer recommendations - 301 Ruukki's delivery 321. /EA3SM310___/ Sealant 301. /EA3SPBSK___/ Expandable sealing band Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, System door, horizontal section single door SPA09-ENERGY-2E-EN . 15.06.2011 Ruukki 1:2.5 19.08.2013 C SPA09-ENERGY-2E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Sealant during installation (installed in the factory) Sealant Note! System door is installed during installation of SPA panels. Note! Openings must be taken into account in dimensioning of SPA panels. Note! System door is installed during installation of SPA panels. sealant >200mm in length on the outside. Note! Remember to seal the grooves of the SPA panels joining the door during the installation with Sealant during installation Supporting structures according to structural designer 001. Sandwich panel SPA ENERGY, horizontal installation 231. Fastener for flashing, washer with sealing 182. Drip flashing, t=0.6mm, according to project 201. Self-drilling panel screw, washer with sealing 301. /EA3SPBSK___/ Expandable sealing band Note! Openings must be taken into account in dimensioning of SPA panels. System door fastening according to manufacturer recommendations 302. /EA3SS410/ Sealing band 183. Storm flashing, t=0.6mm, according to project Ruukki's delivery 303. /EA3SS1210/ Sealing band (installed in the factory) Sealant Date Scale Drawn by Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, System door, vertical section double door, supporting structure SPA09-ENERGY-3E-EN . 15.06.2011 Ruukki 1:4 19.08.2013 D SPA09-ENERGY-3E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. 321. /EA3SM310___/ Sealant 201 > 5 0 + - 1 321 321 302 183 321 182 182 183 231 302 301 303 001. Sandwich panel SPA ENERGY, horizontal installation 231. Fastener for flashing, washer with sealing 185. Cover flashing, t=0.6mm, according to project 201. Self-drilling panel screw, washer with sealing Ruukki's delivery 301. /EA3SPBSK___/ Expandable sealing band sealant >200mm in length on the outside. Note! Remember to seal the grooves of the SPA panels joining the door during the installation with System door fastening according to manufacturer recommendations Supporting structures according to structural designer 303. /EA3SS1210/ Sealing band 302. /EA3SS410/ Sealing band Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Date Scale Drawn by Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation, System door, horizontal section double door, supporting structure SPA09-ENERGY-4E-EN . 15.06.2011 Ruukki 1:4 19.08.2013 D SPA09-ENERGY-4E-EN.dwg . in the factory) Sealant (installed Sealant during installation Note! System door is installed during installation of SPA panels. Note! Openings must be taken into account in dimensioning of SPA panels. 321. /EA3SM310___/ Sealant + - 185 >50 321 303 302 231 321 201 1 301 231 321 302 232 181 + - 001. Sandwich panel SPA ENERGY, horizontal installation 189. Cover flashing, t=0.6mm, according to project 181. Drip flashing, t=0.6mm, according to project 321. /EA3SM310___/ Sealant Ruukki's delivery 301. /EA3SPBSK___/ Expandable sealing band 191. Cover flashing, t=0.6mm, according to project sealant >200mm in length on the outside. Note! Remember to seal the grooves of the SPA panels joining the door during the installation with Supporting structures if necessary according to structural designer Sealant during installation 189 181 189 191 310 302. /EA3SS410/ Sealing band 191 321 321 234 100 100. /EA1D___/ Purlin 302 234. Flat headed screw 232. Fastener for flashing 231. Fastener for flashing, washer with sealing 321 1 301 310. /EA_____/ Mineral wool Sealant (installed in the factory) Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation Door, vertical section . SPA09-ENERGY-5E-EN . 15.06.2011 Ruukki 1:2.5 19.08.2013 C SPA09-ENERGY-5E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. (SPA09-03E) Note! Openings must be taken into account in dimensioning of SPA panels. 1 + - sealant >200mm in length on the outside. Note! Remember to seal the grooves of the SPA panels joining the door during the installation with Note! Openings must be taken into account in SPA dimensioning. Supporting structures if necessary according to structural designer 310 302 231 321 321 191 100 001. Sandwich panel SPA ENERGY, horizontal installation 231. Fastener for flashing, washer with sealing 191. Cover flashing, t=0.6mm, according to project 310. /EA_____/ Mineral wool Ruukki's delivery 301. /EA3SPBSK___/ Expandable sealing band 232. Fastener for flashing 302. /EA3SS410/ Sealing band 100. /EA1D___/ Purlin 192 234 192 191 321 192. Cover flashing, t=0.6mm, according to project 234. Flat headed screw 232 321. /EA3SM310___/ Sealant 301 Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation Door, horizontal section . SPA09-ENERGY-6E-EN . 15.06.2011 Ruukki 1:2.5 19.08.2013 C SPA09-ENERGY-6E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. Sealant (installed in the factory) Sealant during installation (SPA09-04E) Ruukki's delivery 231. Fastener for flashing, washer with sealing 302. /EA3SS410/ Sealing band 201. Self-drilling panel screw, washer with sealing 100. /EA1D___/ Door frame stud, if necessary 303. /EA3SS1210/ Sealing band 001. Sandwich panel SPA ENERGY, horizontal installation 241. Fastener, washer with sealing Note! Openings must be taken into account in dimensioning of SPA panels. sealant >200mm in length on the outside. Note! Remember to seal the grooves of the SPA panels joining the door during the installation with Supporting structures if necessary according to 193. Drip-/cover flashing, t=0.6mm, according to project Sealant during installation 300. /EA3SP___10/ Sealing band, if necessary Sealant (installed in the factory) Date Scale Drawn by Rev. Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation Overhead door, vertical section . SPA09-ENERGY-7E-EN . 15.06.2011 Ruukki 1:7.5 19.08.2013 D SPA09-ENERGY-7E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. structural designer (SPA09-03E) Sealant after installation + - 1 321 302 300 303 302 193 100 241 201 231 321. /EA3SM310___/ Sealant sealant >200mm in length on the outside. Note! Remember to seal the grooves of the SPA panels joining the door during the installation with Note! Openings must be taken into account in dimensioning of SPA panels. Sealant during installation 001. Sandwich panel SPA ENERGY, horizontal installation 231. Fastener for flashing, washer with sealing 194. Cover flashing, t=0.6mm, according to project 201. Self-drilling panel screw, washer with sealing Ruukki's delivery 300. /EA3SP___10/ Sealing band, if necessary Supporting structures according to structural designer 241. Fastener, washer with sealing 100. /EA1D___/ Door frame stud, if necessary 302. /EA3SS410/ Sealing band Sealant (installed in the factory) Date Scale Drawn by Drawing nr. File nr. Rev. date Building Rev. Work nr. Contents of drawing Sandwich panel SPA ENERGY, horizontal installation Overhead door, horizontal section . SPA09-ENERGY-8E-EN . 15.06.2011 Ruukki 1:4 19.08.2013 D SPA09-ENERGY-8E-EN.dwg . Copyright Rautaruukki Oyj. Allowed only for designs with Ruukki's products. 303. /EA3SS1210/ Sealing band + - 241 303 194 231 201 1 302 300 100