Doc No OS20-12-03

Origin Korea
Technical Bulletin Date Dec 29, 2020
Global Installation Team
Page 1/2

【OS20-12-03 HIP-xA64 Type Change of Grounding Point】


We would like to inform the grounding(earth) point of HIP-xA64 type has been
changed. The ESD plate no longer exist. Please refer to below.

1. Grounding Point (Before)


- Rear side of the button plate, ESD Plate

2. Grounding Point (After)


- Rear side of the button, weld stud bolt

Sort Before After

Hall Button
Grounding
Point

Electrostatic discharge Electrostatic discharge


through ESD plate or back through weld stud (also
panel used for frame and
faceplate assemble)

* Attachment : HIP/HPB Grounding Manual


Doc No OS20-12-03

Origin Korea
Technical Bulletin Date Dec 29, 2020
Global Installation Team
Page 2/2

【HIP/HPB Grounding Manual】

1. Applied Models
- HPB-A64 / HIP-DA64 / HIP-LA64

2. Grounding Point
Sort Before After

Hall Button
Grounding
Point

Back
Panel

ESD Weld
Plate stud

Electrostatic discharge Electrostatic discharge


through ESD plate or back through weld stud
panel