Vous êtes sur la page 1sur 11

Veuillez trouver ci joint le rapport de l'SSV du site 3G_ESSAIID 2, fichier de DT sur le serveur sous le

nom :ssv_ ESSAIID 2

S1 495 S2 497 S3 506


Max Avg Max Avg Max Avg
HSDPA U900 8680 3799 7435 3277 7440 3363
Throughput U2100 7645 3540 6842 3219 7842 3419
HSUPA U900 2566 986 2605 1657 2550 1340
Throughput U2100 2521 1388 2554 982 2454 1670
U900 ok ok ok
Voice call
U2100 ok ok
ok
Test dynamique PSC 495,495et 506test dynamique OK

Veuillez trouver ci joint le rapport de l'SSV du site 3G__SHARM SHIIK, pour la band U900 vérification a
plusieurs reprise valeur moyenne légèrement ???? merci de vérifie les tilts et les nombres des
utilisateurs entre 11h et 13h30.

fichier de mesure sur le serveur FTP: ssv SHARM SHIIK

S1 psc230 S2 psc231 S3 psc232


Remarque
Avg Max Avg Max Avg Max
HSDPA U900 2603 7115 1715 6486 1673 6701
Throughput U2100 3491 8095 3784 8183 3552 8346
HSUPA U900 1740 2583 811 2245 1638 2735
Throughput U2100 1596 2550 1644 2566 1602 2551
U900 ok
Voice call
U2100 ok
Test dynamique PSC 230_231et 232 test dynamique OK

Veuillez trouver ci joint le rapport de l'SSV du site ASWAN, objectif atteint .


S1 109 S2 110 S3 111
Max Avg Max Avg Max Avg
HSDPA U900 7668 3162 6409 2073 NA NA
Throughput U2100 6952 2724 7151 3184 7062 3246
HSUPA U900 2588 1662 2730 433 NA NA
Throughput U2100 2622 1129 2521 1541 2533 1575
U900 ok ok
Voice call
U2100 ok
ok
Test dynamique PSC 109_110_et111 test dynamique OK pas de secteur 2 U900

-fichier de DT sur le serveur FTP : nom SSV KHAN KHALIL.

S1 257 S2 258 S3 259


Max Avg Max Avg Max Avg
HSDPA U900 6967 3003 6423 2828 7524 3557
Throughput U2100 7090 2819 7638 3277 7251 3247
HSUPA U900 2638 1077 2482 1728 2566 1800
Throughput U2100 2545 1281 2730 1691 2516 1573
U900 ok ok ok
Voice call
U2100 ok ok
ok
Test dynamique PSC 257,258 et 259 test dynamique OK

GSM and WCDMA Single site verification SSV


Single site verification (SSV) is an audit method, where we need to check the entire KPI
(Key performance indicator), coverage and quality for a single radio base station site.

For GSM (Global System for Mobile Communications) network a single site has more than
twenty KPI (Key performance indicator), on the other hand for WCDMA (Wideband Code Division
Multiple Access) including HSPA plus a single site has more than forty five Key performance
indicators (KPI). But all the KPI doesn’t carries the same morals, on the other hand less significant KPI
values depends on the major KPIs. So, we often check major Key performance indicators for single
site verification (SSV). The entire single site verification (SSV) can be categorized into three
subcategory.

These are:

 Radio frequency parameter verification (RF verification).

 Radio frequency (RF) functionality test.

 Drive test and RNO (Radio network optimizer) verification.

Radio frequency parameter audit (RF audit):

RF audit may be classified into parts:

1. General parameter audit.


2. Radio parameter audit.

General parameter audit:

In general parameter audit, we have to check the coordinate(latitude and longitude) of radio
base station, address, BTS/RBS information (BTS/RBS name, model or version, vendor etc.),
Cluster name and type, transceiver configuration (TRX conf), business region name and type,
BSC (Base station controller) name, MSC (Main switching center) name, radio base station
security guard or gate keeper contract or house owner contract details.
An example of general parameter audit is given bellow:

Figure: General radio parameter audit information.


Radio parameter audit:

In a radio parameter audit, we need to check entire RF parameter such as antenna height, cell
azimuth, electrical tilt, mechanical tilt, feeder cable type, feeder cable length, antenna
information (model with vendor information), Base station identity code (BSIC), allocated
ARFCN (absolute radio frequency channel number) in BCCH (broadcasting control channel),
Location area code (LAC) etc.

An example of RF (Radio Frequency) parameters audit is given bellow:

Figure: Radio frequency (RF) parameter audit information.

Tools and software for RF parameters audit:

 Digital or magnetic compass.

 Digital camera.

 Tilting meter.

 Fifty meter measuring tape.

 Safety tools for rigger.

 Google Earth (Software)

Drive test and Radio network optimizer (RNO) verification:

Drive test and Radio network optimizer (RNO) verification is the final step for single site
verification (SSV). For SSV drive test we need to unique arrangement for testing terminals.

Tools and Software for single site verification (SSV) drive test (DT):

 TEMS Investigation data collection software.

Or

 Genex probe

Or
 Nemo outdoor.

 Mapinfo professional (minimum version 8.5scp)

 Microsoft excel (as a SSV template)

Or

 Microsoft Power point (As a SSV template)

 Mobile Station (MS)

 Inverter (as a power source for laptop)

 GPS (Global positioning system) receiver.

An example of Drive test equipment arrangement is given bellow:

Figure: Drive Test equipment arrangement.

Drive test (DT) procedure:

Drive test is the most significant event in entire verification process. For single site verification
(SSV) drive test (DT); we use three mobile stations (MS) as a testing terminal. This Mobile
station (MS) are designated as MS1, MS2 and MS3 respectively. Also we use GPS receiver
(global positioning system) as a testing terminal.

SSV Mobile station (MS) configuration:

Mobile station-1 (MS1):

typically MS1 configured in idle mode and locked with the site. For locking Mobile station
(MS), actually we have to lock Broadcasting Control Channel (BCCH) for all cell.

Mobile station-2 (MS2):


Typically MS2 configured in dedicated mode short call and unlocked. Usually short call
duration is thirty seconds. There is no limit of number of test call. Test call will be continued
entire test period with ten seconds as a frequent call interval period. Redial triggers should be
Time out, blocked call and dropped call.

Mobile station-3 (MS3):

Typically MS3 configured in dedicated mode long call and unlocked. Usually, there is no limit
for long call duration. Redial triggers should be Time out, blocked call and dropped call.

Figure: Command sequence for MS2 and MS3.

Drive Test (DT) Log collection method:

  Start collecting log files from the site access road of SSV (Single site
verification) radio base site to neighbor site access road, collect the log files in
both way, that means from the SSV (Single site verification) radio base site to
neighbor radio base site and neighbor radio base site to SSV (Single site
verification) radio base site.

 Run the command sequence for mobile station-2 (MS2) and mobile
station-3 (MS3), cover the entire car accessible road surrounding (360
degree) of radio base SSV site. Please check the figure in bellow:
Figure: Single site verification (SSV) drive test (DT) route.

Drive Test (DT) data presentation System:

Event Analysis:

All the mobile station is significant to check performance of radio base site
through Drive Test (DT). We have to present major drive test (DT) event in
reporting templates. The major Drive Test (DT) events comprises of number of
call attempts, number of call established, call setup success rate (CSSR),
number of handover attempt, number of successful handover, Handover
success rate (HOSR), number of dropped call and dropped call rate (CDR).
The presentation of drive test major event analysis is given bellow:

Figure: Drive Test (DT) event analysis

From Mobile Station-1 (Idle mode) SSV data presentation:


From mobile station-1 (MS1), we collect total coverage area of a radio base
site and received signal strength (RxLevel) , also we check cell mismatch
(feeder cable swap). An example of total coverage area and received signal
strength (Rxlevel) of radio base site is given bellow:

Figure: Total coverage area of SSV radio base site.

From Mobile Station-2_MS2 (dedicated mode) SSV data presentation:

Form mobile station (MS2), we check basic functionality test, events, handover
sequence number (HSN), mobile allocation index offset (MAIO) of radio base
site. MS2 functionality test include call setup, call setup time, Inter Site
handover, Intra site handover (handover between radio base sites own cell).
We have already discussed about event analysis of Drive Test.

From Mobile Station-3_MS3 (dedicated mode) SSV data presentation:

From mobile station-3, we check received signal quality (RxQual), handover


relation status (inter cell and intra cell), call continuity, serving cell footprint of
SSV drive test route, overshooting of neighbor cell, planning parameter such as
ARFCN (Absolute Radio Frequency Channel number) of BCCH (broadcasting
control channel).
An example of serving cell footprint diagram is given bellow:
Figure: Serving cell footprint of SSV DT route.

RNO (Radio network optimizer) and RNP (Radio network planner)


Remarks:

RNP remarks: There is no mismatch found within planned and implemented


radio frequency parameter, radio base site coverage footprint is satisfactory.
RNO Remarks: Site performance is satisfactory, Key performance indicator
(KPI) monitoring will be continued on daily basis.

Abstract:

 ARFCN:

"ARFCN means for Absolute Radio Frequency Channel number. There are
124 ARFCN in P-GSM, 175 in E-GSM, 375 in DCS 1800.

 BCCH:

BCCH means for broadcasting control channel, it's a down link channel of
GSM air interface. BCCH carries system information of radio base station
including available features, configuration and identity.

 Call setup success rate (CSSR):

"Call setup success rate is the ration between the number of handover attempts
and number of successful handover. CSSR is presented in percentage."
 Cell ID:

"Every individual cell of mobile network has a unique cell ID for own
network, also there is a cell global identity (CGI). CGI = Mobile country code
(MCC) + Mobile network code (MNC) + Location area code (LAC) + cell Id
(CI)."

 Drive Test (DT):

"Drive test (DT) is a network log collection procedure in vehicular mode."

 Drive test (DT) Logs:

" Drive test log files include network signaling and event information; which is
collected in real time through Drive Test (DT). Also we can collect logs from
the BSC (Base station controller) end through IMEI (International Mobile
station Equipment Identity) tracing."

 Intra site Handover:

"Intra site handover is the handover between two cell of same radio base site.

 Inter site Handover:

"Inter site handover is the handover between two adjacent or neighbor sites
cell.

 Handover Success rate (HOSR):

"Handover success rate (HOSR) is the radio between number of


handover attempts and number of successful handover. HOSR is
presented in percentage."

 Radio frequency (RF) functionality test:

“Radio frequency functionality test means for checking the various


functionality of a single radio base site such as general call test (both long call
and short call), call continuity test (long call only), network accessibility test
(short call), data throughput test, call setup time etc."

 Radio frequency parameter verification (RF verification):

“Radio frequency parameter verification (RF verification) means for


verifications of installed radio parameter with the previously planned radio
parameter.”
Figure: Received signal quality of entire single site verification SSV of radio base
station serving area.