Vous êtes sur la page 1sur 2

CALCUL DES STRUCTURES ACIER

---------------------------------------------------------------------------------------------------------------------------------
-------
NORME: CM66
TYPE D'ANALYSE: Dimensionnement des familles
---------------------------------------------------------------------------------------------------------------------------------
-------
FAMILLE: 3 Traverses_1
PIECE: 23 Barre_23 POINT: 1 COORDONNEE: x = 0.00 L = 0.00
m
---------------------------------------------------------------------------------------------------------------------------------
-------
CHARGEMENTS:
Cas de charge décisif: 7 EFF /13/ 1*1.33 + 2*1.42 + 13*1.42
---------------------------------------------------------------------------------------------------------------------------------
-------
MATERIAU:
ACIER fy = 235.00 MPa
---------------------------------------------------------------------------------------------------------------------------------
-------

PARAMETRES DE LA SECTION: IPE 270


ht=27.0 cm
bf=13.5 cm Ay=27.54 cm2 Az=17.82 cm2 Ax=45.94 cm2
ea=0.7 cm Iy=5789.78 cm4 Iz=419.87 cm4 Ix=14.93 cm4
es=1.0 cm Wely=428.87 cm3 Welz=62.20 cm3
---------------------------------------------------------------------------------------------------------------------------------
-------
CONTRAINTES: SigN = 137.45/45.94 = 0.29 MPa
SigFy = 7719.65/428.87 = 176.52 MPa
SigFz = 287.12/62.20 = 45.27 MPa
---------------------------------------------------------------------------------------------------------------------------------
-------

PARAMETRES DE DEVERSEMENT:
---------------------------------------------------------------------------------------------------------------------------------
-------
PARAMETRES DE FLAMBEMENT:

en y: en z:

Ly=5.40 m Muy=3053.12 Lz=5.40 m Muz=221.41


Lfy=5.40 m k1y=1.00 Lfz=5.40 m k1z=1.00
Lambda y=48.10 kFy=1.00 Lambda z=178.63 kFz=1.01
---------------------------------------------------------------------------------------------------------------------------------
-------
FORMULES DE VERIFICATION:
k1*SigN + kFy*SigFy + kFz*SigFz = 1.00*0.29 + 1.00*176.52 + 1.01*45.27 = 222.49 < 235.00 MPa
(3.731)
1.54*Tauy = |1.54*-1.33| = |-2.05| < 235.00 MPa (1.313)
1.54*Tauz = 1.54*35.06 = 53.99 < 235.00 MPa (1.313)
---------------------------------------------------------------------------------------------------------------------------------
-------
Profil correct !!!