Vous êtes sur la page 1sur 1

02-0073945 - TABLE BALCON / profile de rive G

format A3 : 2/9
plan d'assemblage des éléments A / B / C / D / E / F / G

500 235 235 500

217
130 24 24 24 24 24 24 24 24

375 1105 1105

186 568 832 568 186

16
185
375

299
130 60

2210
2370

Dessin de Fabrication
Finition RAL 2002 BRILLANT PERI S.A.S.
i o n
ss
Zone Industrielle Nord Tel: +33 1.64.35.24.40
34/36 rue des Frères Lumière Fax: +33 1.64.35.24.50
The execution of steel structures shall be in
accordance with:
EN 1090-2 (Technical requirements for
steel structures)
77109 Meaux Cedex

g r e eMail: peri.sas@peri.fr

ro
DR-22-064674_0.dwg Profile gauche_1

Execution class in accordance with EN 1090-2: EXC 2


Assemblage
p
Welding proc. in acc. with EN ISO 4063: MAG - 135
Quality requirements in acc. with: EN ISO 3834-3 Nom Date
Sujet

En
Non-destructive testing in acc. with EN ISO 17635
Approved shielding gases in acc. with DIN EN ISO 14175
with scope of testing in accordance with EN 1090-2 Dessiné: David Lemaire 2022-06-27
Filler metals in accordance with DIN EN 13479: DIN EN ISO 14341 -A G 42 2 M G3Si1
Undimensioned fillet welds: a= 4 mm Repres. of all welding symbols acc. to DIN EN ISO 2553 - syst. A
Échelles N° de dessin Feuille Version
Vérifié:
1:10 DR-22-064674 2 0
2022-07-06

Important!! Deviations from the given Execution Classes (EXC) All tolerances and weld specifications are valid for all similar
are to declared separately through the welding symbol! components, connections and symmetry lines! Copyright, © PERI, tous droits réservés.
All dimensions and all dimensions with tolerances are test dimensions! Il n'est pas permis de faire usage de ce dessin sauf avec une autorisation écrite ou un accord spécifique.
.

h/b = 297 / 420 mm