Vous êtes sur la page 1sur 3

2 Detailed Specifications 1

Molded Case Circuit Breakers

NF-S (Standard class)


100 125 125 125 160 225 250
NF125-SV NF125-SGV NF125-SEV NF160-SGV NF250-SV

2
(15) 16 20 (30) 32 40 16-20 20-25 25-32 32-40 35-50 (100) 125 150 160
125 16-32 32-63 63-125 125-160 250
50 (60) 63 (75) 80 100 45-63 56-80 70-100 90-125 175 200 225 (*2)
2 3 4 2 3 4 2 3 4 3 4 2 3 4 2 3 4 2 3 4
690 690 690 690 690 690 690
8/8 8/8 8/8 8/8 8/8 8/8 8/8
18/18 18/18 30/30 30/30 30/30 30/30 30/30
25/25 25/25 36/36 36/36 36/36 36/36 36/36

1 Detailed Specifications
30/30 30/30 36/36 36/36 36/36 36/36 36/36
30/30 30/30 36/36 36/36 36/36 36/36 36/36
30/30 30/30 36/36 36/36 36/36 36/36 36/36
50/50 50/50 85/85 85/85 85/85 85/85 85/85
50/50 50/50 85/85 85/85 85/85 85/85 85/85
40/40 (*3) 40/40 (*3) 20/20 (300V) (*3) − 20/20 (300V) (*3) 20/20 (300V) (*3) 20/20 (300V) (*3)
8 8 8 8 8 8 8
AC/DC compatible AC/DC compatible AC/DC compatible AC AC/DC compatible AC/DC compatible (*1) AC/DC compatible (*1)
Compatible Compatible Compatible Compatible Compatible Compatible Compatible
Possible Possible Possible Possible Possible Possible Possible
25,000 25,000 50,000 25,000 40,000 25,000 25,000
10,000 10,000 30,000 10,000 15,000 10,000 10,000
A A A A A A A
3 3 3 3 3 3 3
N/A N/A N/A A N/A N/A N/A
60 90 120 60 90 120 105 140 105 140 105 140 105 140 105 140
130 130 165 165 165 165 165
68 68 68 68 68 68 68
90 90 92 92 92 92 92
0.7 1.0 1.3 0.7 1.0 1.3 1.4 1.6 2.0 1.7 2.2 1.4 1.6 2.0 1.4 1.6 2.0 1.4 1.6 2.0
dScrew terminal dScrew terminal dScrew terminal dScrew terminal dScrew terminal dScrew terminal dScrew terminal
d d d d d d d d d d
dBar stud dBar stud dBar stud dBar stud dBar stud dBar stud dBar stud dBar stud
d d d d d d d d d d d d
d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d
d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d
d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d
d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d d (*4) d
d d d d d d d d d d d d
− − − d − − −
d − d − d − d − d − d − d −
d − d − d − d − d − d − d −
− d − − d − d − d − d − d − d −
− d − d d d d d d
d d d d d d d d d d d d
d − d − d d − d d − d −
d d d d d d d
d d d d d d d
d d d d d d d
d d d d d d d
− d d − d d d d d d
d d d d d d d d d d d d
d d d d d d d d d d d d
d d d d d d d d d d d d
− − − − − − −
Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration TÜV approval Self-declaration TÜV approval Self-declaration
Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process Recognition in process
 −  −  (LR, ABS, GL) −  (LR, ABS, GL) −  (LR, ABS, GL) −  −  −
Thermal-magnetic Thermal-magnetic Thermal-magnetic Electronic (effective value detection) Thermal-magnetic Thermal-magnetic Thermal-magnetic
Equipped Equipped Equipped Equipped Equipped Equipped Equipped
144 152 154 152 148
Remarks: 1. Products with rated current parenthesized are produced when an order is placed.
2. Specify “P-LT” when using a plug-in product with a lead-wire terminal block.
3. The circuit breaker has the rated short-circuit breaking capacity specified in the shaded cells.

17
Characteristics
7 and Dimensions 1 Molded Case Circuit Breakers

NF250-CV
Model NF250-CV NF250-SV NF250-HV
(*1) (100) (*1) (100)
125 150 160 175
Rated current In (A) 125 150 175 200 125 150 160 175

NF250-SV
200 225 250
225 250 200 225 250
Number of poles 2 3 2 3 4 2 3 4
Rated insulation voltage Ui (V) 600 690 690

NF250-HV 690V
500V
440V

10/8
15/12
8/8
30/30
36/36
10/8
50/38
65/65
Rated
short-circuit AC 415V 25/19 36/36 70/70
IEC 60947-2
breaking
(Icu/Ics) 400V 25/19 36/36 75/75
capacity
(kA) 380V 25/19 36/36 75/75
230V 36/27 85/85 100/100
DC (*1) 250V 15/12 20/20 (300V) 40/40 (300V)
Standard attached parts Mounting screw: M4×0.7×55 (2 and 3P: 2pcs, 4P: 4pcs)
(front connection) Insulation barrier: (2P: 2pcs, 3P: 4pcs, 4P: 6pcs)
Note *1 Use two poles for three- and four-pole products. In this case, do not use the neutral pole of the four-pole products.
If wired as shown at the bottom of page 14, three-pole NF250-CV can be used for up to 400VDC, three-pole NF250-SV
and NF250-HV up to 500VDC and four-pole products up to 600VDC.

NF250-SV

Operating Characteristics
4h 4h
2h Operating characteristics 2h
Operating characteristics
1h NF250-CV 100A-225A 1h NF250-CV 250A
NF250-SV 100A-225A NF250-SV 250A
30min NF250-HV 125A-225A 30min NF250-HV 250A
20min 20min
14min 14min
10min 10min
6min 6min
4min 4min
2min 2min
Max. Max.
1min 1min
Operating time

Operating time

30s 30s
20s 20s
Max. total breaking time Max. total breaking time
10s 10s
5s 5s
Min. Min.
2s 2s
1s 1s
0.5s 0.5s
AC
0.2s 0.2s
AC
0.1s 0.1s
DC DC
0.05s 0.05s

0.02s 0.02s
Time-delay trip Instantaneous trip Time-delay trip Instantaneous trip
0.01s 0.01s
1 1.25 2 3 4 5 6 7 10 15 20 30 40 1 1.25 2 3 4 5 6 7 10 15 20 30 40

× 100% of rated current × 100% of rated current

Internal Accessories Temperature Compensation Curve


Lead-wire
Operating handle AL AX SHT or UVT
Rated ambient

direction 130
temperature
Current rating (%)

Left-side mounting Right-side mounting 120

110

7 (Rated ambient 80
100

90

temperature 40°C) –10 0 10 20 30 40 50 60

Ambient temperature (°C)


1 Characteristics and Dimensions

External Accessories
Accessories Type name Reference page Accessories Type name Reference page
F F-2SV 117 2, 3P MI-05SV3
Operating handle Mechanical interlock MI 129
V V-2SV 119 4P MI-2SV4
LC LC-05SV Small TC-S 2, 3P TCS-2SV3
HLF-05SV TCL-2SV3
Handle lock device HL(*1) 127 2, 3P
HLN-05SV Large TC-L TCL-2SV3L
Terminal
HL-S HLS-2SV 4P TCL-2SV4 121
cover
Notes *1 HLF types are used for OFF lock and HLN types for ON lock. Skeleton TTC 2, 3P TTC-2SV3
*2 Specify the working voltage. Refer to the reference page for type name.
Rear BTC 2, 3P BTC-2SV3
Plug-in PTC 2, 3P PTC-2SV3
Electrical operation device (*2) 133

148
7 Characteristics and Dimensions 1
Molded Case Circuit Breakers
NF250-CV · NF250-SV · NF250-HV
Outline Drawing

Front connection

30
M8 bolt
Insulation barrier (hex-socket) 24
(removable) Breaker
Mounting hole
Solderless terminal

100
for wire size
125-175A 14-95mm2
200-250A 70-125mm2
Wire connection

144

165

102

126
.5
50

f8
f4.5

10
1
C

C
1
Trip button 25 max.

f8.5
100
45 Or 35 35
22 35 .5
61 f8
M40.7 taps
Neutral pole or f5
70 105 68

9
4 72 25 max. 3-pole 4-pole
105 140
92 (Conductor thickness
3-pole 4-pole t=7 max.)

Conductor drilling Drilling plan


for direct connection

Rear connection

4-pole
Mounting base
4-pole 3-pole
Mounting plate Stud can be
rotated 90° Breaker Breaker
t = 3.2 max. 3-pole
8

144
144

126

52
R
Connection
22 allowance
20

M40.7 breaker
mounting screw 32.5
6 f24 35
15
35 35 100
15 f9 70 M40.7 taps
Insulation
M8 bolt tube or f5
105 70 105
68 71 1.0mm clearance on each side
of the handle frame
72 106 3-pole 4-pole

Drilling plan Front-panel cutout

Plug-in

4-pole 145

7
3-pole 110
Plug-in
Mounting terminal block
34.5

Breaker (plug-in terminal block)


plate

Connection
56.5

allowance
1 Characteristics and Dimensions
24
190

165

80
144

54

11
70
6

151

56.5
15

20
28

f9
21 M5 M8 bolt 70 105 f6 hole
terminal block 3-pole 70
31 107 142 or M50.8 taps
mounting screw Insulation
4-pole 105 Stud attachable in this
89 30 barrier direction only
112 3-pole 105 3-pole 4-pole
4-pole 140
Drilling plan

Remarks: 1. 2-pole models are 3-pole models with the central pole removed.
2. Only 2-pole and 3-pole models are available for NF250-CV.

149

Vous aimerez peut-être aussi