Name: VENTILATEUR PORTE A FAUX

Path: TAHWILL SETIF


ANALYSE VIBRATOIRE

F(Hz) A(M/S^2) V(M/S) S(uM)


24.4481 0.1009 0.657 4.2771
25.075 0.082 0.5205 3.3035
41.3737 0.2873 1.1052 4.2515
42.0006 0.3069 1.163 4.4072
48.2694 0.1223 0.4032 1.3295
48.8962 0.3326 1.0827 3.5242
49.5231 0.2189 0.7036 2.2612
73.3444 0.4116 0.8932 1.9381
73.9712 0.2897 0.6233 1.341

Parameter Value
Name palier n°1 horizontale moteur
Template No
Units MM/S
Amplifier mode Int1
Averages Avg.: Off
Booster Autotuning
Sensor sensitivity 95,83984 mV/g
Amplifier koeff. 0
Start mode Free + 0 ms
Trigger External
Window type Hanning
Range 10..1003
Lines FFT 1600
Common level RMS = 2,654 ETAT ADMISSIBLE
Tracking analysis No
Phase No
Synchro*K 0
Measure date 11.01.2024 09:20:32

défaut de fixation
Name: VENTILATEUR PORTE A FAUX
Path: TAHWILL SETIF
ANALYSE VIBRATOIRE

F(Hz) A(M/S^2) V(M/S) S(uM)


24.4481 0.0751 0.4892 3.1843
25.075 0.0542 0.3438 2.182
48.8962 0.0728 0.2369 0.7712
73.3444 0.134 0.2908 0.6309
73.9712 0.1004 0.2161 0.4649
75.225 0.123 0.2602 0.5506
95.9119 0.211 0.3502 0.5811
96.5387 0.1876 0.3092 0.5098
121.6137 0.1541 0.2016 0.2638
122.2406 0.4251 0.5534 0.7205
122.8675 0.3609 0.4675 0.6055
Parameter Value
Name palier n°1 moteur verticale
Template No
Units MM/S
Amplifier mode Int1
Averages Avg.: Off
Booster Autotuning
Sensor sensitivity 95,83984 mV/g
Amplifier koeff. 0
Start mode Free + 0 ms
Trigger External
Window type Hanning
Range 10..1003
Lines FFT 1600
Common level RMS = 1,3655
Tracking analysis No
Phase No
Synchro*K 0
Measure date 11.01.2024 09:21:00
Name: VENTILATEUR PORTE A FAUX
Path: TAHWILL SETIF
ANALYSE VIBRATOIRE

F(Hz) A(M/S^2) V(M/S) S(uM)


23.8212 0.0962 0.6426 4.2931
24.4481 0.2312 1.5052 9.7987
25.075 0.1341 0.8514 5.4039
42.0006 0.1259 0.4771 1.8079
48.8962 0.2522 0.8209 2.6719
49.5231 0.1605 0.5157 1.6572
122.2406 0.4294 0.559 0.7278

Parameter Value
Name palier n°2 horizontale moteur
Template No
Units MM/S
Amplifier mode Int1
Averages Avg.: Off
Booster Autotuning
Sensor sensitivity 95,83984 mV/g
Amplifier koeff. 0
Start mode Free + 0 ms
Trigger External
Window type Hanning
Range 10..1003
Lines FFT 1600
Common level RMS = 2,5769 ETAT ADMISSIBLE
Tracking analysis No
Phase No
Synchro*K 0
Measure date 11.01.2024 09:19:30

défaut de fixation
VENTILATEUR PORTE A FAUX
Path: TAHWILL SETIF
ANALYSE VIBRATOIRE

F(Hz) A(M/S^2) V(M/S) S(uM)


23.8212 0.0232 0.155 1.0357
24.4481 0.0675 0.4394 2.8601
25.075 0.0488 0.31 1.9679
27.5825 0.0245 0.1414 0.8157
41.3737 0.071 0.2731 1.0505
42.0006 0.0748 0.2835 1.0744
48.8962 0.0935 0.3044 0.9909
49.5231 0.059 0.1896 0.6092
55.165 0.0818 0.2361 0.6813
55.7919 0.1256 0.3582 1.0219
62.6875 0.0731 0.1855 0.4711
Parameter Value
Name palier n°2 verticale moteur
Template No
Units MM/S
Amplifier mode Int1
Averages Avg.: Off
Booster Autotuning
Sensor sensitivity 95,83984 mV/g
Amplifier koeff. 0
Start mode Free + 0 ms
Trigger External
Window type Hanning
Range 10..1003
Lines FFT 1600
Common level RMS = 1,4467
Tracking analysis No
Phase No
Synchro*K 0
Measure date 11.01.2024 09:20:00
Name: VENTILATEUR PORTE A FAUX
Path: TAHWILL SETIF
ANALYSE VIBRATOIRE

F(Hz) A(M/S^2) V(M/S) S(uM)


23.8212 0.0322 0.2153 1.4382
24.4481 0.08 0.5205 3.3883
25.075 0.0463 0.294 1.8659
144.8081 0.1769 0.1944 0.2136
145.435 0.1512 0.1655 0.1811

Parameter Value
Name palier n°3 horizontale turbine
Template No
Units MM/S
Amplifier mode Int1
Averages Avg.: Off
Booster Autotuning
Sensor sensitivity 95,83984 mV/g
Amplifier koeff. 0
Start mode Free + 0 ms
Trigger External
Window type Hanning
Range 10..1003
Lines FFT 1600
Common level RMS = 0,7833
Tracking analysis No
Phase No
Synchro*K 0
Measure date 11.01.2024 09:18:20

état bon R.A.S


Name: VENTILATEUR PORTE A FAUX
Path: TAHWILL SETIF
ANALYSE VIBRATOIRE

F(Hz) A(M/S^2) V(M/S) S(uM)


24.4481 0.0228 0.1486 0.9673
73.3444 0.0559 0.1213 0.2632
513.4106 0.7799 0.2418 0.0749
514.0375 1.1363 0.3518 0.1089

Parameter Value
Name palier n°3 verticale turbine
Template No
Units MM/S
Amplifier mode Int1
Averages Avg.: Off
Booster Autotuning
Sensor sensitivity 95,83984 mV/g
Amplifier koeff. 0
Start mode Free + 0 ms
Trigger External
Window type Hanning
Range 10..1003
Lines FFT 1600
Common level RMS = 0,6182
Tracking analysis No
Phase No
Synchro*K 0
Measure date 11.01.2024 09:18:44

état bon R.A.S


Name: VENTILATEUR PORTE A FAUX
Path: TAHWILL SETIF
ANALYSE VIBRATOIRE

F(Hz) A(M/S^2) V(M/S) S(uM)


23.8212 0.0743 0.4964 3.3164
24.4481 0.1937 1.261 8.2092
25.075 0.1187 0.7534 4.782
41.3737 0.1265 0.4867 1.8724
42.0006 0.1361 0.5157 1.954
48.8962 0.1713 0.5574 1.8144

Parameter Value
Name palier n°4 horizontale turbine
Template No
Units MM/S
Amplifier mode Int1
Averages Avg.: Off
Booster Autotuning
Sensor sensitivity 95,83984 mV/g
Amplifier koeff. 0
Start mode Free + 0 ms
Trigger External
Window type Hanning
Range 10..1003
Lines FFT 1600
Common level RMS = 1,9753
Tracking analysis No
Phase No
Synchro*K 0
Measure date 11.01.2024 09:17:28

état bon R.A.S


Name: VENTILATEUR PORTE A FAUX
Path: TAHWILL SETIF
ANALYSE VIBRATOIRE

F(Hz) A(M/S^2) V(M/S) S(uM)


24.4481 0.0449 0.2924 1.9033
25.075 0.0286 0.1815 1.1522
48.8962 0.1323 0.4305 1.4013
49.5231 0.077 0.2474 0.795
121.6137 0.1436 0.1879 0.246
122.2406 0.4392 0.5719 0.7446
122.8675 0.3361 0.4353 0.5639
299.6462 0.366 0.1944 0.1032
300.2731 0.3667 0.1944 0.103

Parameter Value
Name palier n°4 verticale turbine
Template No
Units MM/S
Amplifier mode Int1
Averages Avg.: Off
Booster Autotuning
Sensor sensitivity 95,83984 mV/g
Amplifier koeff. 0
Start mode Free + 0 ms
Trigger External
Window type Hanning
Range 10..1003
Lines FFT 1600
Common level RMS = 1,195
Tracking analysis No
Phase No
Synchro*K 0
Measure date 11.01.2024 09:17:56

état bon R.A.S