Vous êtes sur la page 1sur 4

Typedecollecteur

Coefficientderugosit
deManningStrickler
Pentemoyenneddelacanalisation
Dbitd'oragebrut
Diamtrethoriqueducollecteur
Diamtreducollecteur
Vitessepleinesection
Dbitpleinesection
Rapportdesdbits
Rapportdesvolumes

Vitessed'coulement
Hauteurderemplissage

Donnesdel'tude
Fossherbe,terre,canalmaonnerie,conduite
bton,fibresciment,fonte,grs,PVC
Dpenddutypedecollecteur

Dth =4

5
8

QA

( )

3
8

Ks=
I=
Q=
Dth=

85
3.0 mm/m
1.200 m3/s
931 mm

K S I

ChoisirlasectioncommerialesuprieureDth

V PS =K S I
2

Q PS =

Conduitebton

D
4

()

2
3

D
V PS
4

(Qh/QPS)
FonctiondeQ/QPS
Vh/VH
Lirelesvaleursdansl'abaque
h/H
(Vh/H)xVPS
(h/H)xD

D=
VPS=

1000 mm

QPS=

1.451 m3/s

Qh/QPS=
Vh/VH=
h/H=
V=
h=

1.85 m/s

0.827
1.118
0.693
2.07 m/s
693 mm

Conditionsd'autocurage
Condition0
Rappel
(Qh/QPS)=
0.827
Condition1:Pour(Qh/QPS)/10
Vh1/VH1=
0.61
Condition2:Pour(Qh/QPS)/100
Vh2/VH2=
0.30

Vitessed'coulementV>1.00m/s
(Qh/QPS)/10= 0.0827 (Qh/QPS)/100= 0.0083
Pour(Qh/QPS)/10=>V1=((Vh1/VH1)xVPS)
Ilfautvrifier:V1>0.60m/s
Pour(Qh/QPS)/100=>V2=((Vh2/VH2)xVPS)
IlfautvrifierV2>0.30m/s

Contrle:

Vrifi

V1=

1.13 m/s
Vrifi

V2=

0.56 m/s
Vrifi

Zone d'interpolation
h/H
0.000
0.025
0.050
0.075
0.100
0.125
0.150
0.175
0.200
0.225
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650
0.700
0.750
0.775
0.800
0.825
0.850
0.875
0.900
0.925
0.950
0.975
1.000

S/D
0.0000
0.0052
0.0147
0.0268
0.0409
0.0567
0.0739
0.0923
0.1118
0.1323
0.1535
0.1982
0.2450
0.2934
0.3428
0.3927
0.4426
0.4920
0.5404
0.5872
0.6319
0.6531
0.6736
0.6931
0.7115
0.7287
0.7445
0.7586
0.7707
0.7802
0.7854

R/D
0.0000
0.0160
0.0330
0.0480
0.0640
0.0790
0.0930
0.1080
0.1210
0.1340
0.1470
0.1710
0.1940
0.2150
0.2340
0.2500
0.2650
0.2780
0.2880
0.2970
0.3020
0.3040
0.3040
0.3040
0.3040
0.3010
0.2990
0.2940
0.2870
0.2770
0.2500

Vh/VH
Qh/QH
0.0000
0.0000
0.1590
0.0010
0.2570
0.0045
0.3330
0.0112
0.4010
0.0208
0.4640
0.0334
0.5160
0.0487
0.5670
0.0567
0.6150
0.0876
0.6600
0.1113
0.7000
0.1366
0.7760
0.1956
0.8420
0.2623
0.9020
0.3364
0.9550
0.4169
1.0000
0.4997
1.0380
0.5853
1.0710
0.6713
1.0990
0.7550
1.1210
0.8380
1.1310
0.9099
1.1390
0.9461
1.1390
0.9753
1.1390
1.0042
1.1390
1.0305
1.1310
1.0491
1.1240
1.0654
1.1110
1.0728
1.0930
1.0734
1.0680
1.0606
1.0000
1.0000

Tta
Vh/VH
0.00 0.0000
36.39 0.1590
51.68 0.2570
63.58 0.3330
73.74 0.4010
82.82 0.4640
91.15 0.5160
98.92 0.5670
106.26 0.6150
113.27 0.6600
120.00 0.7000
132.84 0.7760
145.08 0.8420
156.93 0.9020
168.52 0.9550
180.00 1.0000
191.48 1.0380
203.07 1.0710
214.92 1.0990
227.16 1.1210
240.00 1.1310
246.73 1.1390
253.74 1.1390
261.08 1.1390
268.85 1.1390
277.18 1.1310
286.26 1.1240
296.42
1.1110
308.32 1.0930
323.61 1.0680
360.00 1.0000

h/H

Cible

Interpol
Vh

Interpol
h

Cible1

0.000
0.025
0.050
0.075
0.100
0.125
0.150
0.567

0.175
0.200
0.225
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650

1.099

1.1181

0.6934

0.700
0.750
0.775
0.800
0.825
0.850
0.875
0.900
0.925
0.950
0.975
1.000

1.1181 0.6934

e d'interpolation
Cible2

Interpol
Vh1

0.257

Interpol
Vh2

0.2998

1.200
Vh/V
H
1.000

0.6074

0.800

0.600

0.400

0.200

0.000
0.0000

0.2000

( ) ( ))

S=
sin
cos
4 2
2
2
0.6074 0.2998

0.4000

0.6000

0.8000

h
en Rad =2 A cos 12
H

1.0000

1.2000

00

1.0000

1.2000

Vous aimerez peut-être aussi