Vous êtes sur la page 1sur 1

12 11 10 9 8 7 6 5 4 3 2 1

00 SHT. 492/721 H019-MND-MHS4-CVS-S-DFM-005 AMNS DRG. No.


BILL OF MATERIALS

61
GRID LOCATION WEIGHT IN KGS.
130 HR-8 <A/1'-2 ERECTION
MARK.
ITEM
NO.
MATL.
SPCN.
SECTION
LENGTH
IN mm.
REQD.
NOS. UNIT WT.
EREC.
NOS.
WT. FOR
REMARKS.
TOTAL WT. ALL EREC.
HR-8 33.32 1 33.32

77 E250 TS32NB3.2 3752 1 3.01 11.60


H H
109 E250 TS32NB3.2 1008 3 3.01 9.36

117 E250 TS32NB3.2. 100 3 3.01 0.92

130 E250 TS25NB3.2 495 1 2.41 1.19


A 131 E250 TS25NB3.2 1015 1 2.41 2.44

0
146 E250 TS25NB3.2 1096 2 2.41 5.27

R5
105 209 E350 PL6*90 200 3 47.10 2.54
3115 GRAND TOTAL 33.32

SUMMARY OF STEEL
400 897 897 920 74 66 TYP SR. DESCRIPTION TOTAL WT. MAT. SPECIFICATION
131 3 No.
1 TS25NB3.2 8.89 E250

150 2 TS32NB3.2 20.96 E250

45 45
77 3 TS32NB3.2. 0.92 E250
4 PLT 6 THK 2.54 E350
TOTAL IN KGS. 33.32
G G
209 109
920

PLAN - B - B
117

500
150 109

117 130 C
1286

100
109 31
2 146 77
146 28
F 62 117 66 F
209 117

109 66
117

100

100
400

52
11 109 117
897

19 42 42
117
146
209

75

1157
3115

146
2624

100
146

E 209 E

600
117

30
670
109 117 2 - 18 Ø HOLES
669

200

140
146
209 77
B 11
19
109

30
209 45 45
209
TYP
3

57
90
B
897

45 45
670

D
31
2 SECTION - C - C D
C
131
669

117
109
209
209
400

130
SECTION - A - A
R5
C 0 C
105

REV. A

H019-MND-MHS4-CVS-S-DFM-005_492 OF 721_00
B B

1 NO. HANDRAIL REQD AS DRN MKD HR-8

1. ALL DIMENSIONS ARE IN mm AND LEVELS ARE IN METER. THIS DOCUMENT DISCLOSES PROPRIETARY

2. ALL FILLET WELDS ARE MINIMUM 6mm CONTINUOUS FILLET (U.N.O)


INFORMATION OF AM/NS INDIA LTD. IT MAY
BE REPRODUCED OR DISCLOSED ONLY WITH
ARCELORMITTAL NIPPON STEEL INDIA LIMITED
THE WRITTEN PERMISSION AND IS NOT TO BE

29035-57A-000-STD-0151
3. ALL MEMBERS AND GUSSETS PLATES TO BE CUT AFTER FULL
USED IN ANY WAY DETRIMENTAL TO THE
SCALE SHOP LAYOUT BEFORE FABRICATION. INTEREST OF ARCELORMITTAL NIPPON STEEL
INDIA LIMITED.
M. N. DASTUR & COMPANY (P) LTD
4. ALL HOLES ARE 22Ø FOR M20 BOLT (PROPERTY CLASS 8.8) U.N.O.
CONSULTING ENGINEERS, KOLKATA
5. FOR GENERAL NOTES REFER DRG. NO. H019-MND-PGUH-GEN-S-STD-001. CONSULTANT

SCALE- 1:1 PLANT: MATERIAL HANDLING SYSTEM AREA: CONVEYOR SYSTEM

A DSN GJNA GJNA 12.01.2023 TITLE A


DRN SUN ENGG SUN ENGG 12.01.2023 JUNCTION HOUSE NJH-21B

CLIENT DRG. No.


C 00 12.01.2023 ISSUED FOR CONSTRUCTION SUN ENGG SUN ENGG GJNA CKD SUN ENGG SUN ENGG 12.01.2023 STRUCTURAL FABRICATION DRAWING

DASTUR REV.
1 STRUCTURAL DESIGN DRAWING OF RELOACTED FIRE WATER PUMPHOUSE H019-MND-MHS4-CVS-S-DDR-005 P0 NOT ISSUED APD GJNA GJNA 12.01.2023
This drawing is issued for the specific project mentioned

DRG. No.
ALL APPLICABLE HSE STANDARDS NAME SIGN DATE References Drawings
herein. This is not to be copied or used for other projects. Sr.No. D w g. N o s. I.P. REV. DATE DESCRIPTION DRN CKD APD FINAL APPROVE REV:

Drg. Size-A1
& STATUTORY REQUIREMENTS
GJNA
GJNA 12.01.2023 PLOT DATE : 12.01.2023 AMNS DRG.No. H019-MND-MHS4-CVS-S-DFM-005 HR-8 SHT. 492/721
ARE CONSIDERED & CHECKED. GJNA 12.01.2023 NOTES REFERENCE REVISIONS GJNA 00
Tekla structures

12 11 10 9 8 7 6 5 4 3 2 1 Plt. Scale:
ISSUE PURPOSE (I.P.): R-REVIEW/COMMENTS/PRELIMINARY, D-DESIGN, C-CONSTRUCTION, H-CONSTRUCTION(WITH HOLD), Z-AS BUILT, I-INFORMATION, N-REFERENCE,
E-ENQUIRY, P-PURCHASE, M-IMPLEMENTATION, U-USE, A-APPROVAL,V-CANCELLED OR VOIDED, S-SUPERSEDED BY ANOTHER DOCUMENT No.

Vous aimerez peut-être aussi