Académique Documents
Professionnel Documents
Culture Documents
MCS - LMCSS
Software Baseline Release Document
Document Revision:
Quality Approvals
Originator M. Peters
This document was approved by the signers and authorized by the PEGASUS
administrator.
Part: 4 - AA3
OTIS FIELD COMPONENT MANUAL No.:
Vintage:
JAA26801AAF VIIIc
02 / 4
Central & East Europe
Area Page: 3/ 10
Software Data Date: 22May-2002
PRODUCT MCS - LMCSS D1: 26-Apr-2002
ADMINISTRATION Software Baseline Release Document SCN: GBA 30085 KAA
1. Enhancements:
1.1 Adjustable ANS, FULL, PEAK values for OCSS in case of analog loadweighing
1.2 ABL Enhancement: “PTR drop delay” parameter range increased
2. Corrections:
2.1 Releveling on Overload (OLD) if “OCSS load enable” is set to 0
2.2 ETSC: blocked car after DFC emergency stop
2.3 Reduce false counting of error counters
2.4 Start Enable bit to OCSS: coding corrected
3. Prevention:
3.1 Added 5sec delay before sending “Not Available” to the OCSS
3.2 Send CLD1 Door Command if running on TCI
3.3 Deleted Parameter: “BKL to MOV Tout”
Configuration Number
GBA 30085 KAA
Configuration Identification
Local EN81 baseline software for LMCSS
Applicable for all new EPROMs.
Product Changes
None
Part: 4 - AA3
OTIS FIELD COMPONENT MANUAL No.:
Vintage:
JAA26801AAF VIIIc
02 / 4
Central & East Europe
Area Page: 4/ 10
Software Data Date: 22May-2002
PRODUCT MCS - LMCSS D1: 26-Apr-2002
ADMINISTRATION Software Baseline Release Document SCN: GBA 30085 KAA
Deliverable Media
OTPs and EEPROMs can be ordered from Berlin as programmed chips or Software can be
downloaded via network.
Intel-Hex-File for programming OTPs is located in Pegasus
OTPs
EEPROMs
Dependencies
Software Versions:
This software runs on LMCSS MCBII version JBA26801AAF002 or higher.
• OCSS:
− Software GAE30075FAA or higher, running on RCBII version GAA21270A1 or
higher.
− With software versions before GAE30075CAA the new functions like 6th load
switch or 2nd open door profile cannot be used.
− With software GAC30075BAA wrong (exchanged) load message "Empty car" /
"10%" is send to MCSS (only for MSVF or OVF1).
− With software GAE30075DAA01 improved door time protection open (DTO) is im-
plemented. This is necessary in case of a door bypass error causing a missing DZ
input to the LMCSS.
− With software GAE30075FAA or higher full functionality for EFO and EPO opera-
tion according to British Standard BS-5588.
− For Advanced Brake Lift: for correct functionality of failure handling of DTC
mode the software version GAE30075HAC is required.
Open Items
None.
Reference Documents
Modification Description
The following items describe the error corrections made from version
GBA30085JAA to GBA30085KAA.
3. Enhancements:
1.1 Adjustable ANS, Full, Peak values for OCSS in case of analog loadweighing
Adjustable thresholds for the load status messages to the OCSS:
ANS, FULL, PEAK in case of analog loadweighing.
4. Corrections:
2.1 Releveling on Overtload (OLD) if “OCSS load enable” is set to 0
Releveling on overload was not prevented if the parameter “OCSS load enable” was set
to 0.
3. Prevention:
3.1 Added 5sec delay before sending “Not Available” to the OCSS
Introduction of a 5s delay for the LMCSS to send the “Not Available” status to the OCSS.
The “Not Available” message sets the OCSS in NAV mode and calls are deleted.
For short LMCSS shutdowns, which are recovered immediately and automatically, this must
not be noticed in other systems.
The qualification and verification is done based on the software version GBA30085K17
These preliminary software versions have been successfully tested at the following jobsites:
* The days reproduce only the time with the last ...K17 version.
(complete test with K11 up to K17 version with some improvements was much longer)