NOTE DE CALCUL

SOCIETE:
PROJET: CONSTRUCTION D'UN CENTRE D'ACCUEIL ET DE CONFERENCES A SETTAT

LOT: MENUISERIE ALUMINIUM

BV1

DIMENSIONNEMENT DES MONTANT POUR PARTIES FIX

DONNEES DE CALCUL

FLECHE MAX 1/300 ème


TYPE DE CHARGE UNIFORMEMENT REPARTIE
TYPE D'APPUI 1 APPUI SIMPLE ET 1 APPUIS ENCASTRE
DISTANCE ENTRE APPUIS 3500 mm
TRAME GAUCHE 1180 mm
TRAME DROITE 1180 mm
FLECHE MAXIMALE ADMISSIBLE 11,67 mm
PRESSION DE CALCUL 722 N/m²
MODULE D'ELASTICITE DU MATERIAU 700 000 daN/cm²

FORMULE UTILISEE

INERTIE NECESSAIRE 84,62 cm4

INERTIE DE PROFILE ALU RENFORCE EN TUBE - cm4


METALLIQUE
REF DE PROFIL NA STRUGAL

DIMENSIONNEMENT DES TRAVERSES POUR PARTIE FIX

CALCUL D'INERTIE DES TRAVERSES EN FONCTION DU POIDS DE VITRAGE

L LARGEUR 1,18 m
H HAUTEUR 1,25 m
SURFACE M² 1,475 m²
EPAISSEUR DE VITRAGE 8 mm
P POIDS DE VITRAGE 29,5 kg
P0 DEMIE CHARGE DE VITRAGE P/2 14,75 kg
A 150 mm (POSITION DES CALES D'ASSISES) 150 mm
f = 3 mm MAX

FORMULE UTILISEE

INERTIE NECESSAIRE 1,79 cm4


CALCUL D'INERTIE DES TRAVERSES SUIVANT LA PRESSION DU VENT

FLECHE MAX f 1/300 ème


TYPE DE CHARGE CHARGE TRAPEZOIDALE
DISTANCE ENTRE MENEAUX 1180 mm
HAUTEUR ENTRE TRAVERSES 1750 mm
FLECHE MAXIMALE ADMISSIBLE 3,93 mm
PRESSION DE CALCUL 722 N/m²
MODULE D'ELASTICITE DU MATERIAU 700 000 daN/cm²
HAUTEUR DU TRAPÈSE C 875 mm

LA FORMULE UTILISEE DANS LE CAS OU H EST INFERIEUR À L

INERTIE NECESSAIRE 3,71 cm4

INERTIE DE PROFIL 17,9 cm4 PROFILE VERIFIE


REF DE PROFIL NA STRUGAL

CALCUL DE VITRAGE

ξ Coeficient de Vitrage ( Simple vitrage ξ=1 , Double vitrage ξ=1.5, Stadip=1.3, Trempé=0.8)

C Coeficient de chassis ( Fixe C=0.9 , Ouvrant C=1)

TYPE DE VITRAGE SIMPLE VITRAGE DE 8MM

PRESSION DE VENT 722 N/m²


LARGEUR 1,18 m
HAUTEUR 2,25 m
SURFACE EXPOSEE 2,66 m²

LA FORMULE UTILISEE

PARTIE FIXE -EPAISSEUR


6,04 mm
MINIMALE emin