Vous êtes sur la page 1sur 25

Royaume du Maroc

Ministère des Habous et des affaires


islamiques Direction des Habous
Division des
investissements
Service études et
projets.

PROJET : TRAVAUX DE RESTAURATION DE LA MOSQUEE SIDI


AHMED HAJJI ET SES DEPENDANCES A SALÉ.

NOTE DE CALCUL DE LA COUVERTURE EN CHARPENTE


BOIS
Table des matières

A. DIMENSIONS D’UNE PARTIE DE LA SALLE DE PRIERE..............................................3

E. CHARGES APPLIQUÉES :....................................................................................................8

1- Charge permanente :.........................................................................................................8

2- Charge d’exploitation.........................................................................................................8

Calcul des éléments de la couverture en bois...................................................................................9

A. JUSTIFICATION DES ARBALETRIERS :............................................................................9

B. JUSTIFICATION DES ENTRAITS.......................................................................................12

C. JUSTIFICATION DES POUTRES MURALE (QARQ) :....................................................15

D. JUSTIFICATION DES ENTRAITS RETROUSSES :........................................................18

E. JUSTIFICATION DES SOLIVES (PANNES INTERMEDIARES) :.................................21


I. CALCUL DES CHARGES DE VENT SELON NV65 MAROC
A. DIMENSIONS DE LA CHARPENTE LA PLUS SOLLICITÉE

Portée inférieure à 4m
Type de structure : Portique spatial (BERCHLA)
Coordonnées du centre géométrique de la structure:
X= 2.000 (m)
Y= 4.500 (m)
Z= 2.650 (m)
Coordonnées du centre de gravité de la structure:
X= 2.000 (m)
Y= 4.500 (m)
Z= 1.973 (m)
Moments d'inertie centraux de la structure:
Ix = 556363.984 (kg*m2)
Iy = 344779.320 (kg*m2)
Iz = 723664.824 (kg*m2)
Masse = 65175.794 (kg)
Description de la structure
Nombre de noeuds: 1579
Nombre de barres: 611
Eléments finis linéiques: 1470
Eléments finis surfaciques: 966
Eléments finis volumiques: 0
Liaisons rigides: 0
Relâchements: 0
Relâchements unilatéraux : 0
Relâchements non-linéaires: 0
Compatibilités: 0
Compatibilités élastiques: 0
Compatibilités non-linéaires: 0
Appuis: 62
Appuis élastiques: 0
Appuis unilatéraux: 0
Appuis non-linéaires: 0
Rotules non-linéaires: 0
Cas: 21
Combinaisons: 0

Resumé de l'analyse
Méthode de solution - Multiprocesseur
Nbre de degrés de liberté stat.: 9102

Largeur de la bande
avant/après optimisation: 0 0

Durée des calculs [s]


Durée max agrégation + décomp.: 0
Durée max itér. sur sous-espace: 0
Durée max solution prb. nonlin.: 0
Durée totale: 4
Espace disque et mémoire utilisés [o]
Espace totale du disque utilisé: 4725216
Espace pour fichier TMP solveur: 0
Espace pour itérat. s/sous-esp.: 0
Mémoire: 3002600

Elém. diagon. de la matrice de rigidité


Min/Max après décomposition: 1.797598e+05 4.001175e+10
Précision: 9
Liste de cas de charges/types de calculs

Cas 1 : G
Type d'analyse: Statique linéaire

Energie potentielle : 4.42336e-02 (kN*m)


Précision : 8.71619e-08

Cas 2 : Q
Type d'analyse: Statique linéaire

Energie potentielle : 1.44703e-03 (kN*m)


Précision : 1.23324e-07

Cas 3 : Vent X+ 39 m/s (f =1.00) Simulation


Type d'analyse: Statique linéaire

Energie potentielle : 9.03205e-03 (kN*m)


Précision : 6.02015e-07

Données:
Vitesse du vent : 39.00m/s
Niveau de terrain : 0.00m
Profil de vent : Constant - 1.00
Eléments exposés : Structure entière
Ouvertures : Fermé pour le flux de vent
Critères d'arrêt : Automatique
Somme des efforts principaux : 31.70kN
Somme des forces perpendiculaire : -0.01kN
Somme des composantes verticales : -11.61kN
Précision : 0.50%
La somme des forces peut différer en raison de la simplification du modèle. Les forces
exercées sur les parois du panneau/bardage et les côtés supérieurs/inférieurs sont
ignorées.
Chargement en fonction des cartographies de pression.

Cas 4 : Vent Y+ 39 m/s (f =1.00) Simulation


Type d'analyse: Statique linéaire

Energie potentielle : 1.14709e-03 (kN*m)


Précision : 2.08430e-06

Données:
Vitesse du vent : 39.00m/s
Niveau de terrain : 0.00m
Profil de vent : Constant - 1.00
Eléments exposés : Structure entière
Ouvertures : Fermé pour le flux de vent
Critères d'arrêt : Automatique
Somme des efforts principaux : 5.54kN
Somme des forces perpendiculaire : 0.61kN
Somme des composantes verticales : 2.16kN
Précision : 0.50%
La somme des forces peut différer en raison de la simplification du modèle. Les forces
exercées sur les parois du panneau/bardage et les côtés supérieurs/inférieurs sont
ignorées.
Chargement en fonction des cartographies de pression.
Cas 5 : Vent X- 39 m/s (f =1.00) Simulation
Type d'analyse: Statique linéaire

Energie potentielle : 9.05307e-03 (kN*m)


Précision : 6.05043e-07

Données:
Vitesse du vent : 39.00m/s
Niveau de terrain : 0.00m
Profil de vent : Constant - 1.00
Eléments exposés : Structure entière
Ouvertures : Fermé pour le flux de vent
Critères d'arrêt : Automatique
Somme des efforts principaux : 31.64kN
Somme des forces perpendiculaire : 0.03kN
Somme des composantes verticales : -11.63kN
Précision : 0.50%
La somme des forces peut différer en raison de la simplification du modèle. Les forces
exercées sur les parois du panneau/bardage et les côtés supérieurs/inférieurs sont
ignorées.
Chargement en fonction des cartographies de pression.

Cas 6 : Vent Y- 39 m/s (f =1.00) Simulation


Type d'analyse: Statique linéaire

Energie potentielle : 1.31351e-04 (kN*m)


Précision : 1.26213e-06
Données:
Vitesse du vent : 39.00m/s
Niveau de terrain : 0.00m
Profil de vent : Constant - 1.00
Eléments exposés : Structure entière
Ouvertures : Fermé pour le flux de vent
Critères d'arrêt : Automatique
Somme des efforts principaux : 5.61kN
Somme des forces perpendiculaire : 0.59kN
Somme des composantes verticales : 2.20kN
Précision : 0.50%
La somme des forces peut différer en raison de la simplification du modèle. Les forces
exercées sur les parois du panneau/bardage et les côtés supérieurs/inférieurs sont
ignorées.
Chargement en fonction des cartographies de pression.

Cas 7 : ELU
Type d'analyse:

Cas 8 : ELU+
Type d'analyse:

Cas 9 : ELU-
Type d'analyse:

Cas 10 : ELS
Type d'analyse:
Cas 11 : ELS+
Type d'analyse:

Cas 12 : ELS-
Type d'analyse:

Cas 13 : ELS:CAR
Type d'analyse:

Cas 14 : ELS:CAR+
Type d'analyse:

Cas 15 : ELS:CAR-
Type d'analyse:

Cas 16 : ELS:FRE
Type d'analyse:

Cas 17 : ELS:FRE+
Type d'analyse:

Cas 18 : ELS:FRE-
Type d'analyse:

Cas 19 : ELS:QPR
Type d'analyse:

Cas 20 : ELS:QPR+
Type d'analyse:

Cas 21 : ELS:QPR-
Type d'analyse:

E. CHARGES APPLIQUÉES :

1- Charge permanente :

Poids propre des éléments porteurs de la couverture en bois et les composant de la


couverture en bois (5.00kN/m2)

2- Charge d’exploitation

Charge d’exploitation Q=1.00kN/m2


NOTE DE CALCUL CHARPENTE BOIS

Calcul des éléments de la couverture en bois


A. JUSTIFICATION DES ARBALETRIERS :

----------------------------------------------------------------------------------------------------------------------------------------
NORME: EN 1995-1:2004/A2:2014
TYPE D'ANALYSE: Vérification des pièces
----------------------------------------------------------------------------------------------------------------------------------------
FAMILLE:
PIECE: 431 ARBALETRIER_431 POINT: 1 COORDONNEE: x = 0.00 L =
0.00 m
----------------------------------------------------------------------------------------------------------------------------------------
CHARGEMENTS:
Cas de charge décisif: 8 ELU /1/ 1*1.35 + 2*1.35 + 3*1.50
NOTE DE CALCUL CHARPENTE BOIS

----------------------------------------------------------------------------------------------------------------------------------------
MATERIAU CB_RESIN C18
gM = 1.30 f m,0,k = 8000.00 kPa f t,0,k = 5000.00 kPa f c,0,k = 8500.00 kPa
f v,k = 900.00 kPa f t,90,k = 130.00 kPa f c,90,k = 2100.00 kPa E 0,moyen = 8000000.00 kPa
E 0,05 = 6700000.00 kPa G moyen = 500000.00 kPa Classe de service: 1 Bêta c = 0.20
----------------------------------------------------------------------------------------------------------------------------------------

PARAMETRES DE LA SECTION: arbaletrier(200x200)


ht=20.0 cm
bf=20.0 cm Ay=266.667 cm2 Az=266.667 cm2 Ax=400.000 cm2
ea=10.0 cm Iy=13333.333 cm4 Iz=13333.333 cm4 Ix=19733.3 cm4
es=10.0 cm Wy=1333.333 cm3 Wz=1333.333 cm3
----------------------------------------------------------------------------------------------------------------------------------------
CONTRAINTES CONTRAINTES CARACTERISTIQUES
MINOREES
Sig_c,0,d = N/Ax = 1.46/400.000 = 36.38 kPa f c,0,d = 3923.08 kPa
Sig_m,y,d = My/Wy= 0.38/1333.333 = 286.72 kPa f m,y,d = 3692.31 kPa
Sig_m,z,d = Mz/Wz= 0.20/1333.333 = 150.17 kPa f m,z,d = 3692.31 kPa
Tau y,d = 1.5*-0.02/400.000 = -0.74 kPa f v,d = 415.38 kPa
Tau z,d = 1.5*1.32/400.000 = 49.51 kPa
Tau tory,d = 188.02 kPa, Tau torz,d = 188.02 kPa
----------------------------------------------------------------------------------------------------------------------------------------
Coefficients et paramètres supplémentaires
km = 0.70 kh = 1.00 kmod = 0.60 Ksys = 1.00 kcr = 0.67
----------------------------------------------------------------------------------------------------------------------------------------

PARAMETRES DE DEVERSEMENT:
----------------------------------------------------------------------------------------------------------------------------------------
PARAMETRES DE FLAMBEMENT:

en y: en z:
----------------------------------------------------------------------------------------------------------------------------------------
FORMULES DE VERIFICATION:
(Sig_c,0,d/f c,0,d)^2 + Sig_m,y,d/f m,y,d + km*Sig_m,z,d/f m,z,d = 0.11 < 1.00 (6.19)

(Tau y,d/kcr+Tau tory,d/kshape)/f v,d = 0.43 < 1.00 (Tau z,d/kcr+Tau torz,d/kshape)/f v,d = 0.61 < 1.00
(6.13-4)
NOTE DE CALCUL CHARPENTE BOIS

----------------------------------------------------------------------------------------------------------------------------------------
DEPLACEMENTS LIMITES

Flèches (REPERE LOCAL):


u fin,y = 0.05 mm < u fin,max,y = L/300.00 = 6.73 mm Vérifié
Cas de charge décisif: (1+0.6)*1 + (1+0.6)*2 + (1+0.25*0.6)*3 + (0.667+0*0.6)*5
u fin,z = 0.03 mm < u fin,max,z = L/300.00 = 6.73 mm Vérifié
Cas de charge décisif: (1+0.6)*1 + (1+0.6)*2 + (1+0.25*0.6)*3

Déplacements (REPERE GLOBAL):


----------------------------------------------------------------------------------------------------------------------------------------
Profil correct !!!
NOTE DE CALCUL CHARPENTE BOIS

B. JUSTIFICATION DES ENTRAITS

----------------------------------------------------------------------------------------------------------------------------------------
NORME: EN 1995-1:2004/A2:2014
TYPE D'ANALYSE: Vérification des pièces
----------------------------------------------------------------------------------------------------------------------------------------
FAMILLE:
PIECE: 641 ENTRAIT_641 POINT: 3 COORDONNEE: x = 1.00 L = 3.00 m
----------------------------------------------------------------------------------------------------------------------------------------
CHARGEMENTS:
Cas de charge décisif: 8 ELU /13/ 1*1.35 + 2*1.35 + 3*1.00 + 4*1.50
----------------------------------------------------------------------------------------------------------------------------------------
NOTE DE CALCUL CHARPENTE BOIS

MATERIAU CB_RESIN C18


gM = 1.30 f m,0,k = 8000.00 kPa f t,0,k = 5000.00 kPa f c,0,k = 8500.00 kPa
f v,k = 900.00 kPa f t,90,k = 130.00 kPa f c,90,k = 2100.00 kPa E 0,moyen = 8000000.00 kPa
E 0,05 = 6700000.00 kPa G moyen = 500000.00 kPa Classe de service: 1 Bêta c = 0.20
----------------------------------------------------------------------------------------------------------------------------------------

PARAMETRES DE LA SECTION: Solive (75x150)


ht=15.0 cm
bf=7.5 cm Ay=75.000 cm2 Az=75.000 cm2 Ax=112.500 cm2
ea=3.8 cm Iy=2109.375 cm4 Iz=527.344 cm4 Ix=1444.9 cm4
es=3.8 cm Wy=281.250 cm3 Wz=140.625 cm3
----------------------------------------------------------------------------------------------------------------------------------------
CONTRAINTES CONTRAINTES CARACTERISTIQUES
MINOREES
Sig_t,0,d = N/Ax = -2.18/112.500 = -194.08 kPa f t,0,d = 2650.84 kPa
Sig_m,y,d = My/Wy= -0.03/281.250 = -103.93 kPa f m,y,d = 3692.31 kPa
Sig_m,z,d = Mz/Wz= -0.14/140.625 = -980.85 kPa f m,z,d = 4241.35 kPa
Tau y,d = 1.5*-0.27/112.500 = -36.52 kPa f v,d = 415.38 kPa
Tau z,d = 1.5*-0.04/112.500 = -5.17 kPa
Tau tory,d = 0.16 kPa, Tau torz,d = 0.21 kPa
----------------------------------------------------------------------------------------------------------------------------------------
Coefficients et paramètres supplémentaires
km = 0.70 kh = 1.15 kmod = 0.60 Ksys = 1.00 kcr = 0.67
----------------------------------------------------------------------------------------------------------------------------------------

PARAMETRES DE DEVERSEMENT:
lef = 2.63 m Lambda_rel m = 0.36
Sig_cr = 62217.41 kPa k crit = 1.00
----------------------------------------------------------------------------------------------------------------------------------------
PARAMETRES DE FLAMBEMENT:

en y: en z:
----------------------------------------------------------------------------------------------------------------------------------------
FORMULES DE VERIFICATION:
Sig_t,0,d/f t,0,d + km*Sig_m,y,d/f m,y,d + Sig_m,z,d/f m,z,d = 0.32 < 1.00 (6.18)
Sig_m,y,d/(kcrit*f m,y,d) = 103.93/(1.00*3692.31) = 0.03 < 1.00 (6.33)
(Tau y,d/kcr+Tau tory,d/kshape)/f v,d = 0.13 < 1.00 (Tau z,d/kcr+Tau torz,d/kshape)/f v,d = 0.02 < 1.00
NOTE DE CALCUL CHARPENTE BOIS

(6.13-4)
----------------------------------------------------------------------------------------------------------------------------------------
DEPLACEMENTS LIMITES

Flèches (REPERE LOCAL):


u fin,y = 0.61 mm < u fin,max,y = L/300.00 = 10.00 mm Vérifié
Cas de charge décisif: (1+0.6)*1 + (1+0.6)*2 + (0.67+0.25*0.6)*3 + (1+0*0.6)*4
u fin,z = 0.09 mm < u fin,max,z = L/300.00 = 10.00 mm Vérifié
Cas de charge décisif: (1+0.6)*1 + (1+0.6)*2 + (1+0*0.6)*7

Déplacements (REPERE GLOBAL):


----------------------------------------------------------------------------------------------------------------------------------------
Profil correct !!!
NOTE DE CALCUL CHARPENTE BOIS

C. JUSTIFICATION DES POUTRES MURALE (QARQ) :

----------------------------------------------------------------------------------------------------------------------------------------
NORME: EN 1995-1:2004/A2:2014
TYPE D'ANALYSE: Vérification des pièces
----------------------------------------------------------------------------------------------------------------------------------------
FAMILLE:
PIECE: 489 POINT: 3 COORDONNEE: x = 1.00 L = 2.85 m
----------------------------------------------------------------------------------------------------------------------------------------
CHARGEMENTS:
Cas de charge décisif: 8 ELU /5/ 1*1.35 + 2*1.35 + 3*1.50 + 7*1.00
----------------------------------------------------------------------------------------------------------------------------------------
NOTE DE CALCUL CHARPENTE BOIS

MATERIAU CB_RESIN C18


gM = 1.30 f m,0,k = 8000.00 kPa f t,0,k = 5000.00 kPa f c,0,k = 8500.00 kPa
f v,k = 900.00 kPa f t,90,k = 130.00 kPa f c,90,k = 2100.00 kPa E 0,moyen = 8000000.00 kPa
E 0,05 = 6700000.00 kPa G moyen = 500000.00 kPa Classe de service: 1 Bêta c = 0.20
----------------------------------------------------------------------------------------------------------------------------------------

PARAMETRES DE LA SECTION: Poutre murale(200x150)


ht=15.0 cm
bf=20.0 cm Ay=200.000 cm2 Az=200.000 cm2 Ax=300.000 cm2
ea=7.5 cm Iy=5625.000 cm4 Iz=10000.000 cm4 Ix=6400.0 cm4
es=7.5 cm Wy=750.000 cm3 Wz=1000.000 cm3
----------------------------------------------------------------------------------------------------------------------------------------
CONTRAINTES CONTRAINTES CARACTERISTIQUES
MINOREES
Sig_t,0,d = N/Ax = -0.91/300.000 = -30.20 kPa f t,0,d = 2307.69 kPa
Sig_m,y,d = My/Wy= -1.24/750.000 = -1658.80 kPa f m,y,d = 3692.31 kPa
Sig_m,z,d = Mz/Wz= -0.54/1000.000 = -544.91 kPa f m,z,d = 3692.31 kPa
Tau y,d = 1.5*-0.91/300.000 = -45.64 kPa f v,d = 415.38 kPa
Tau z,d = 1.5*-2.07/300.000 = -103.55 kPa
Tau tory,d = 38.62 kPa, Tau torz,d = 34.67 kPa
----------------------------------------------------------------------------------------------------------------------------------------
Coefficients et paramètres supplémentaires
km = 0.70 kh = 1.00 kmod = 0.60 Ksys = 1.00 kcr = 0.67
----------------------------------------------------------------------------------------------------------------------------------------

PARAMETRES DE DEVERSEMENT:
----------------------------------------------------------------------------------------------------------------------------------------
PARAMETRES DE FLAMBEMENT:

en y: en z:
----------------------------------------------------------------------------------------------------------------------------------------
FORMULES DE VERIFICATION:
Sig_t,0,d/f t,0,d + Sig_m,y,d/f m,y,d + km*Sig_m,z,d/f m,z,d = 0.57 < 1.00 (6.17)

(Tau y,d/kcr+Tau tory,d/kshape)/f v,d = 0.25 < 1.00 (Tau z,d/kcr+Tau torz,d/kshape)/f v,d = 0.45 < 1.00
(6.13-4)
----------------------------------------------------------------------------------------------------------------------------------------
NOTE DE CALCUL CHARPENTE BOIS

DEPLACEMENTS LIMITES

Flèches (REPERE LOCAL):


u fin,y = 0.15 mm < u fin,max,y = L/300.00 = 9.50 mm Vérifié
Cas de charge décisif: (1+0.6)*1 + (1+0.6)*2 + (0.67+0.25*0.6)*3 + (1+0*0.6)*7
u fin,z = 0.77 mm < u fin,max,z = L/300.00 = 9.50 mm Vérifié
Cas de charge décisif: (1+0.6)*1 + (1+0.6)*2 + (1+0.25*0.6)*3 + (0.667+0*0.6)*7

Déplacements (REPERE GLOBAL):


----------------------------------------------------------------------------------------------------------------------------------------
Profil correct !!!
NOTE DE CALCUL CHARPENTE BOIS

D. JUSTIFICATION DES ENTRAITS RETROUSSES :

----------------------------------------------------------------------------------------------------------------------------------------
NORME: EN 1995-1:2004/A2:2014
TYPE D'ANALYSE: Vérification des pièces
----------------------------------------------------------------------------------------------------------------------------------------
FAMILLE:
PIECE: 635 ENTRAIT_635 POINT: 3 COORDONNEE: x = 1.00 L = 1.66 m
----------------------------------------------------------------------------------------------------------------------------------------
CHARGEMENTS:
Cas de charge décisif: 8 ELU /13/ 1*1.35 + 2*1.35 + 3*1.00 + 4*1.50
----------------------------------------------------------------------------------------------------------------------------------------
NOTE DE CALCUL CHARPENTE BOIS

MATERIAU CB_RESIN C18


gM = 1.30 f m,0,k = 8000.00 kPa f t,0,k = 5000.00 kPa f c,0,k = 8500.00 kPa
f v,k = 900.00 kPa f t,90,k = 130.00 kPa f c,90,k = 2100.00 kPa E 0,moyen = 8000000.00 kPa
E 0,05 = 6700000.00 kPa G moyen = 500000.00 kPa Classe de service: 1 Bêta c = 0.20
----------------------------------------------------------------------------------------------------------------------------------------

PARAMETRES DE LA SECTION: Solive (75x150)


ht=15.0 cm
bf=7.5 cm Ay=75.000 cm2 Az=75.000 cm2 Ax=112.500 cm2
ea=3.8 cm Iy=2109.375 cm4 Iz=527.344 cm4 Ix=1444.9 cm4
es=3.8 cm Wy=281.250 cm3 Wz=140.625 cm3
----------------------------------------------------------------------------------------------------------------------------------------
CONTRAINTES CONTRAINTES CARACTERISTIQUES
MINOREES
Sig_t,0,d = N/Ax = -0.33/112.500 = -29.37 kPa f t,0,d = 2650.84 kPa
Sig_m,y,d = My/Wy= -0.01/281.250 = -32.82 kPa f m,y,d = 3692.31 kPa
Sig_m,z,d = Mz/Wz= -0.07/140.625 = -507.09 kPa f m,z,d = 4241.35 kPa
Tau y,d = 1.5*-0.16/112.500 = -21.72 kPa f v,d = 415.38 kPa
Tau z,d = 1.5*0.02/112.500 = 2.09 kPa
Tau tory,d = 1.69 kPa, Tau torz,d = 2.13 kPa
----------------------------------------------------------------------------------------------------------------------------------------
Coefficients et paramètres supplémentaires
km = 0.70 kh = 1.15 kmod = 0.60 Ksys = 1.00 kcr = 0.67
----------------------------------------------------------------------------------------------------------------------------------------

PARAMETRES DE DEVERSEMENT:
lef = 1.80 m Lambda_rel m = 0.30
Sig_cr = 90950.05 kPa k crit = 1.00
----------------------------------------------------------------------------------------------------------------------------------------
PARAMETRES DE FLAMBEMENT:

en y: en z:
----------------------------------------------------------------------------------------------------------------------------------------
FORMULES DE VERIFICATION:
Sig_t,0,d/f t,0,d + km*Sig_m,y,d/f m,y,d + Sig_m,z,d/f m,z,d = 0.14 < 1.00 (6.18)
Sig_m,y,d/(kcrit*f m,y,d) = 32.82/(1.00*3692.31) = 0.01 < 1.00 (6.33)
(Tau y,d/kcr+Tau tory,d/kshape)/f v,d = 0.08 < 1.00 (Tau z,d/kcr+Tau torz,d/kshape)/f v,d = 0.01 < 1.00
NOTE DE CALCUL CHARPENTE BOIS

(6.13-4)
----------------------------------------------------------------------------------------------------------------------------------------
DEPLACEMENTS LIMITES

Flèches (REPERE LOCAL):


u fin,y = 0.30 mm < u fin,max,y = L/300.00 = 5.54 mm Vérifié
Cas de charge décisif: (1+0.6)*1 + (1+0.6)*2 + (1+0.25*0.6)*3
u fin,z = 0.04 mm < u fin,max,z = L/300.00 = 5.54 mm Vérifié
Cas de charge décisif: (1+0.6)*1 + (1+0.6)*2 + (1+0.25*0.6)*3 + (0.667+0*0.6)*5

Déplacements (REPERE GLOBAL):


----------------------------------------------------------------------------------------------------------------------------------------
Profil correct !!!
NOTE DE CALCUL CHARPENTE BOIS

E. JUSTIFICATION DES SOLIVES (PANNES INTERMEDIARES) :

----------------------------------------------------------------------------------------------------------------------------------------
NORME: EN 1995-1:2004/A2:2014
TYPE D'ANALYSE: Vérification des pièces
----------------------------------------------------------------------------------------------------------------------------------------
FAMILLE:
PIECE: 176 POINT: 1 COORDONNEE: x = 0.00 L = 0.00 m
----------------------------------------------------------------------------------------------------------------------------------------
CHARGEMENTS:
Cas de charge décisif: 8 ELU /5/ 1*1.35 + 2*1.35 + 3*1.50 + 7*1.00
----------------------------------------------------------------------------------------------------------------------------------------
NOTE DE CALCUL CHARPENTE BOIS

MATERIAU CB_RESIN C18


gM = 1.30 f m,0,k = 8000.00 kPa f t,0,k = 5000.00 kPa f c,0,k = 8500.00 kPa
f v,k = 900.00 kPa f t,90,k = 130.00 kPa f c,90,k = 2100.00 kPa E 0,moyen = 8000000.00 kPa
E 0,05 = 6700000.00 kPa G moyen = 500000.00 kPa Classe de service: 1 Bêta c = 0.20
----------------------------------------------------------------------------------------------------------------------------------------

PARAMETRES DE LA SECTION: Solive (75x150)


ht=15.0 cm
bf=7.5 cm Ay=75.000 cm2 Az=75.000 cm2 Ax=112.500 cm2
ea=3.8 cm Iy=2109.375 cm4 Iz=527.344 cm4 Ix=1444.9 cm4
es=3.8 cm Wy=281.250 cm3 Wz=140.625 cm3
----------------------------------------------------------------------------------------------------------------------------------------
CONTRAINTES CONTRAINTES CARACTERISTIQUES
MINOREES
Sig_t,0,d = N/Ax = -0.22/112.500 = -19.77 kPa f t,0,d = 2650.84 kPa
Sig_m,y,d = My/Wy= -0.31/281.250 = -1111.30 kPa f m,y,d = 3692.31 kPa
Sig_m,z,d = Mz/Wz= -0.09/140.625 = -634.12 kPa f m,z,d = 4241.35 kPa
Tau y,d = 1.5*0.44/112.500 = 58.50 kPa f v,d = 415.38 kPa
Tau z,d = 1.5*0.61/112.500 = 81.95 kPa
Tau tory,d = 8.02 kPa, Tau torz,d = 10.07 kPa
----------------------------------------------------------------------------------------------------------------------------------------
Coefficients et paramètres supplémentaires
km = 0.70 kh = 1.15 kmod = 0.60 Ksys = 1.00 kcr = 0.67
----------------------------------------------------------------------------------------------------------------------------------------

PARAMETRES DE DEVERSEMENT:
lef = 1.28 m Lambda_rel m = 0.25
Sig_cr = 128094.67 kPa k crit = 1.00
----------------------------------------------------------------------------------------------------------------------------------------
PARAMETRES DE FLAMBEMENT:

en y: en z:
----------------------------------------------------------------------------------------------------------------------------------------
FORMULES DE VERIFICATION:
Sig_t,0,d/f t,0,d + Sig_m,y,d/f m,y,d + km*Sig_m,z,d/f m,z,d = 0.41 < 1.00 (6.17)
Sig_m,y,d/(kcrit*f m,y,d) = 1111.30/(1.00*3692.31) = 0.30 < 1.00 (6.33)
(Tau y,d/kcr+Tau tory,d/kshape)/f v,d = 0.23 < 1.00 (Tau z,d/kcr+Tau torz,d/kshape)/f v,d = 0.32 < 1.00
NOTE DE CALCUL CHARPENTE BOIS

(6.13-4)
----------------------------------------------------------------------------------------------------------------------------------------
DEPLACEMENTS LIMITES

Flèches (REPERE LOCAL):


u fin,y = 0.47 mm < u fin,max,y = L/300.00 = 5.00 mm Vérifié
Cas de charge décisif: (1+0.6)*1 + (1+0.6)*2 + (1+0.25*0.6)*3 + (0.667+0*0.6)*7
u fin,z = 0.07 mm < u fin,max,z = L/300.00 = 5.00 mm Vérifié
Cas de charge décisif: (1+0.6)*1 + (1+0.6)*2 + (1+0.25*0.6)*3 + (0.667+0*0.6)*6

Déplacements (REPERE GLOBAL):


----------------------------------------------------------------------------------------------------------------------------------------
Profil correct !!!