Académique Documents
Professionnel Documents
Culture Documents
WAAET
………..
DU 04/04/2022 AU 14/05/2022
SOMMAIRE :
I. INTRODUCTION : .................................................................................................................... 5
II. PRESENTATION DE LA SOOCIETE AL WATAN AL ARABI DES ETUDES ET
D’INGENIEURUE : .......................................................................................................................... 6
1. La fiche technique du bureau des études techniques WAAT : .................................................. 6
2. Les missions de BET : ............................................................................................................. 6
III. L’ETUDE D’UN PROJET D’IRRIGATION LOCALISE........................................................ 9
1. FICHE TECHNIQUE DU PROJET ......................................................................................... 9
2. AVANT LA REALISATION DU PROJET ............................................................................. 9
Les études topographiques : ................................................................................................. 9
La pédologie du sol :....................................................................................................... 10
Le sol : ............................................................................................................................... 11
Les eaux d’irrigation : ..................................................................................................... 12
3. Les paramètres d’irrigation : .................................................................................................. 14
Pluie efficace en (mm/mois) : ............................................................................................. 14
Evapotranspiration potentielle ou référentielle en (mm/j) : .............................................. 15
Coefficient cultural Kc : ..................................................................................................... 15
Evapotranspiration maximale en (mm/j) : ....................................................................... 16
Les besoins en eau en (mm/j) : ........................................................................................... 17
La superficie irrigue ou nette en (ha) : ................................................................................ 18
4. Les calculs hydrauliques ........................................................................................................ 19
Distributeur et l’écartement : .............................................................................................. 19
Calcules hydrauliques ..................................................................................................... 19
Débit global de la parcelle en (m3/h) :................................................................................. 20
Superficie de secteur en m2: ............................................................................................ 20
Débit de secteur en m3/h: .................................................................................................... 20
Temps d'irrigation total : .................................................................................................... 20
Poste d’irrigation : .......................................................................................................... 21
Calculs des rampes : ....................................................................................................... 22
Calcul des portes rampes : .................................................................................................. 24
Variation maximale de pression par Poste : ........................................................................ 29
LES TABLEAUX :
I. INTRODUCTION :
La société a pour objet tant au Maroc qu’à l’étranger tant pour son compte que
pour le compte des tiers :
Un levé topographique consiste à collecter des données sur le terrain (la superficie,
le positionnement et l’altitude) afin d’en proposer une restitution à l’échelle
souhaitée sous la forme d’un plan topographique.
un traitement informatisé des relevés de terrain a été assuré à l’aide du
logiciel «COVADIS » et « AUTOCAD ». Il a été ainsi établi un plan
topographique à l’échelle1/1000 avec des courbes de niveau dont
l’équidistance est de 1m.
La pédologie du sol :
la couverture
quaternaire (limono-
argileux)
le tertiaire (sable
gravier)
le socle paleozoique
(schisteux)
Le sol :
Les analyses de sols sont la partie essentielle sur laquelle repose tout programme de
gestion agronomique dans une production agricole.
Les paramètres analysés dans les analyses de sol
La fraction de l'eau des précipitations qui répond aux besoins en eau des
cultures et représente 70% des précipitations.
Les précipitations de la région Rabat Sale Kenitra sont :
Mois Jan Févr. Mars Avril Mai Juin Juill. Août Sept Oct. Nov. Déc.
Nombre de jours /
31.0 28.0 31.0 30.0 31.0 30.0 31.0 31.0 30.0 31.0 30.0 31.0
mois
Pluie (mm/mois) 82.6 64.4 46.0 46.0 22.9 3.6 0.3 0.9 14.1 54.3 85.1 3.1
P Efficace (mm/mois)
57.8 45.1 32.2 32.2 16.0 2.5 0.2 0.6 9.9 38.0 59.6 2.2
=70%*P
Mar
Mois Jan Févr Avril Mai Juin Juill Août Sept Oct Nov Déc
s
Nombre de jours / 31.
31.0 28.0 31.0 30.0 31.0 30.0 31.0 31.0 30.0 31.0 30.0
mois 0
Pluie (mm/mois) 82.6 64.4 46.0 46.0 22.9 3.6 0.3 0.9 14.1 54.3 85.1 3.1
P Efficace
57.8 45.1 32.2 32.2 16.0 2.5 0.2 0.6 9.9 38.0 59.6 2.2
(mm/mois) =70%P
ET0 (mm/j) 1.8 2.2 2.9 3.5 4.3 5.3 6.2 5.8 5.0 3.7 2.6 2.0
104. 133. 159. 193. 178. 150. 114. 60.
ET0 (mm/mois) 56.7 61.6 89.0 78.0
1 0 0 1 9 3 1 5
Coefficient cultural Kc :
Mar
Mois Jan Févr Avril Mai Juin Juill Août Sept Oct Nov Déc
s
Nombre de jours / 31.
31.0 28.0 31.0 30.0 31.0 30.0 31.0 31.0 30.0 31.0 30.0
mois 0
Pluie Efficace
82.6 64.4 46.0 46.0 22.9 3.6 0.3 0.9 14.1 54.3 85.1 3.1
(mm/mois)
P Efficace
57.8 45.1 32.2 32.2 16.0 2.5 0.2 0.6 9.9 38.0 59.6 2.2
(mm/mois) =70%P
ET0 (mm/j) 1.8 2.2 2.9 3.5 4.3 5.3 6.2 5.8 5.0 3.7 2.6 2.0
104. 133. 159. 193. 178. 150. 114. 60.
ET0 (mm/mois) 56.7 61.6 89.0 78.0
1 0 0 1 9 3 1 5
Kc 0.2 0.2 0.3 0.5 0.6 0.6 0.6 0.6 0.6 0.4 0.2 0.2
ETM = Kc*ETP
Mar
Mois Jan Févr Avril Mai Juin Juill Août Sept Oct Nov Déc
s
Nombre de jours / 31.
31.0 28.0 31.0 30.0 31.0 30.0 31.0 31.0 30.0 31.0 30.0
mois 0
Pluie Efficace
82.6 64.4 46.0 46.0 22.9 3.6 0.3 0.9 14.1 54.3 85.1 3.1
(mm/mois)
P Efficace
57.8 45.1 32.2 32.2 16.0 2.5 0.2 0.6 9.9 38.0 59.6 2.2
(mm/mois) =70%P
ET0 (mm/j) 1.8 2.2 2.9 3.5 4.3 5.3 6.2 5.8 5.0 3.7 2.6 2.0
104. 133. 159. 193. 178. 150. 114. 60.
ET0 (mm/mois) 56.7 61.6 89.0 78.0
1 0 0 1 9 3 1 5
Kc 0.2 0.2 0.3 0.5 0.6 0.6 0.6 0.6 0.6 0.4 0.2 0.2
ETM (mm/j) 0.4 0.4 0.9 1.6 2.4 3.2 3.7 3.5 3.0 1.5 0.5 0.4
Besoin net Bn : Le besoin net en eau d'irrigation est défini comme l'eau
requise par l'irrigation pour satisfaire l'évapotranspiration des cultures et
les besoins en eau auxiliaires (lessivage, modification de la température,
qualité des cultures), qui ne sont pas fournis par l'eau stockée dans le
profil du sol ou les précipitations.
Bn = ETM*Kr
Mois Jan Févr Mars Avril Mai Juin Juill Août Sept Oct Nov Déc
Nombre de jours / mois 31.0 28.0 31.0 30.0 31.0 30.0 31.0 31.0 30.0 31.0 30.0 31.0
Pluie Efficace
82.6 64.4 46.0 46.0 22.9 3.6 0.3 0.9 14.1 54.3 85.1 3.1
(mm/mois)
P Efficace (mm/mois)
=70%P
57.8 45.1 32.2 32.2 16.0 2.5 0.2 0.6 9.9 38.0 59.6 2.2
ET0 (mm/j) 1.8 2.2 2.9 3.5 4.3 5.3 6.2 5.8 5.0 3.7 2.6 2.0
ET0 (mm/mois) 56.7 61.6 89.0 104.1 133.0 159.0 193.1 178.9 150.3 114.1 78.0 60.5
Kc 0.2 0.2 0.3 0.5 0.6 0.6 0.6 0.6 0.6 0.4 0.2 0.2
ETM (mm/j) 0.4 0.4 0.9 1.6 2.4 3.2 3.7 3.5 3.0 1.5 0.5 0.4
Kr 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
Bn (mm/j) 0.3 0.3 0.6 1.1 1.7 2.2 2.6 2.4 2.1 1.0 0.4 0.3
Bb= Bn / Ea
Mois Jan Févr Mars Avril Mai Juin Juill Août Sept Oct Nov Déc
Nombre de jours / mois 31.0 28.0 31.0 30.0 31.0 30.0 31.0 31.0 30.0 31.0 30.0 31.0
Pluie Efficace
82.6 64.4 46.0 46.0 22.9 3.6 0.3 0.9 14.1 54.3 85.1 3.1
(mm/mois)
P Efficace (mm/mois)
57.8 45.1 32.2 32.2 16.0 2.5 0.2 0.6 9.9 38.0 59.6 2.2
=70%P
ET0 (mm/j) 1.8 2.2 2.9 3.5 4.3 5.3 6.2 5.8 5.0 3.7 2.6 2.0
ET0 (mm/mois) 56.7 61.6 89.0 104.1 133.0 159.0 193.1 178.9 150.3 114.1 78.0 60.5
Kc 0.2 0.2 0.3 0.5 0.6 0.6 0.6 0.6 0.6 0.4 0.2 0.2
ETM (mm/j) 0.4 0.4 0.9 1.6 2.4 3.2 3.7 3.5 3.0 1.5 0.5 0.4
Kr 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
Bn (mm/j) 0.3 0.3 0.6 1.1 1.7 2.2 2.6 2.4 2.1 1.0 0.4 0.3
Ea (%) 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9
Bb (mm/j) 0.3 0.3 0.7 1.2 1.8 2.5 2.9 2.7 2.3 1.1 0.4 0.3
3
Bb (m /ha/mois) 88.2 95.8 207.6 364.4 568.9 742.0 901.3 834.7 701.4 354.9 121.3 94.0
Mois Jan Févr Mars Avril Mai Juin Juill. Août Sept Oct. Nov. Déc.
Nombre de
31.0 28.0 31.0 30.0 31.0 30.0 31.0 31.0 30.0 31.0 30.0 31.0
jours / mois
Pluie Efficace
82.6 64.4 46.0 46.0 22.9 3.6 0.3 0.9 14.1 54.3 85.1 3.1
(mm/mois)
P Efficace
(mm/mois) 57.8 45.1 32.2 32.2 16.0 2.5 0.2 0.6 9.9 38.0 59.6 2.2
=70%P
ET0 (mm/j) 1.8 2.2 2.9 3.5 4.3 5.3 6.2 5.8 5.0 3.7 2.6 2.0
ET0
56.7 61.6 89.0 104.1 133.0 159.0 193.1 178.9 150.3 114.1 78.0 60.5
(mm/mois)
Kc 0.2 0.2 0.3 0.5 0.6 0.6 0.6 0.6 0.6 0.4 0.2 0.2
ETM (mm/j) 0.4 0.4 0.9 1.6 2.4 3.2 3.7 3.5 3.0 1.5 0.5 0.4
Kr 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
Bn (mm/j) 0.3 0.3 0.6 1.1 1.7 2.2 2.6 2.4 2.1 1.0 0.4 0.3
Ea (%) 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9
Bb (mm/j) 0.3 0.3 0.7 1.2 1.8 2.5 2.9 2.7 2.3 1.1 0.4 0.3
Bb
88.2 95.8 207.6 364.4 568.9 742.0 901.3 834.7 701.4 354.9 121.3 94.0
(m3/ha/mois)
Superficie
29.7 29.7 29.7 29.7 29.7 29.7 29.7 29.7 29.7 29.7 29.7 29.7
irriguée (ha)
Bb (m3/mois) 2621.4 2846.5 6166.8 10823.3 16899.7 22041.7 26773.1 24796.2 20835.7 10543.1 3604.3 2793.3
Superficie
29.7 29.7 29.7 29.7 29.7 29.7 29.7 29.7 29.7 29.7 29.7 29.7
totale (ha)
NB : Besoin en eau de pointe brut estimé (mm/j) est le besoin maximal pour notre culture =2.9
mm/j
Tableau2 : bilan hydrique
Distributeur et l’écartement :
P = (qg*Nbre rampes)/
Pluviométrie en mm/h =1.33 mm/h
(Eg*El)
Le temps d’irrigation en
T= Bb/P =17.44 h
h
Débit d’exploitation en
Q=P/Sup =396.08 m3/h
m3/h
Qg = (Sup*Pf)/1000
Qg = (297058.1881*1.33)/1000 = 396.08cm3/h
Supsect=Sup nette/Nbresect.
Qsect = Qg / Nbresect
Ttotal = T*Nbresect
Poste d’irrigation :
Sup de poste en m2 :
Qp = Ng*qg/1000
Postes d'irrigation
Durée
Superficies Nb, de
Secteur Poste Cultures d’irrigation Débits (m3/h)
(m2) goutteurs
(h)
P1 12375.00 4125 16.50
S1 P2 OLIVIER (6*5) 2.18 12377.00 4126 16.50
P3 12377.00 4126 16.50
Total Secteur 2.18 37129.00 12376 49.51
S2 P4 OLIVIER (6*5) 2.18 12377.00 4126 16.50
Qr = (Lr*qg/Er)*1000
ITSA ZRAIB 2021/2022
Royaume du Maroc
WAAET
Vitesse en (m/s) :
V = Qr / S avec S = π D2 /4
Donc : V = 4*Qr/π D2
Qr : débit de la rampe en l/h
D : diamètre de la rampe en mm
L’intervalle de la vitesse admissible sur la rampe est entre 0,5m/s et 1m/s.
Perte de charge en m :
Pdc = 0,174*Dr-4,75*Qr1,75*Lr*1,1
Pdc : perte de charge en m
Dr : diamètre de la rampe en mm
Qr : débit de la rampe en l/h
Lr : la langueur de la rampe en m
Perte de charge en m :
Pdc = 0,174*Dpr-4,75*Qpr1,75*Lpr*1,1
Pdc : perte de charge en m
Dpr : diamètre de la porte rampe en mm
L’intervalle de la vitesse admissible sur la rampe est entre 1 m/s et 1,5 m/s.
- 16 16 16 13 9 -
3 4 9 176. PDC à des 0.5 0. 1. 1. 1.
P8 176 16.50 0. 502 0 502 0 502 127 188 0.00 1.66 1.0 0.66
6 .12 2 8 00 normes 4 82 18 33 48
1 57 .67 .67 .67 .98 0
- 16 16 16 12 8 1 -
4 4 195. PDC à des 0.5 0. 1. 1. 1.
P9 195 16.50 0. 502 0 502 0 502 948 886 0 0.00 1.78 1.0 0.78
1 51 .67 .67 .67 2 .25 8 .05 5 00 0
normes 4 82 18 32 43
- 16 16 16 12 8 -
P1 3 4 6 141. PDC à des 0.5 0. 1. 1. 1.
141 16.50 0. 502 0 502 0 502 991 075 0.00 0.78 1.0 -0.22
0 0 .46 2 9 00 normes 4 82 18 32 30
1 71 .67 .67 .67 .77 0
- 16 16 16 13 8 -
P1 3 4 8 158. PDC à des 0.5 0. 1. 1. 1.
158 16.50 0. 502 0 502 0 502 369 982 0.00 1.34 1.0 0.34
1 0 .25 2 .46 6 00 normes 4 82 18 36 45
1 63 .67 .67 .67 0
- 16 16 16 13 9 -
P1 3 4 9 175. PDC à des 0.5 0. 1. 1. 1.
175 16.50 0. 502 0 502 0 502 107 147 0.00 1.63 1.0 0.63
2 6 .83 2 7 00 normes 4 82 18 33 48
1 57 .67 .67 .67 .19 0
- 16 16 16 12 6 -
P1 2 4 4 107. PDC à des 0.5 0. 1. 1. 1.
107 16.50 0. 503 0 503 0 503 801 323 0.00 0.07 1.0 -0.93
3 4 .43 2 .60 1 00 normes 4 82 18 30 02
1 93 .05 .05 .05 0
- 16 16 16 13 7 -
P1 2 4 5 120. PDC à des 0.5 0. 1. 1. 1.
120 16.50 0. 503 0 503 0 503 202 426 0.00 0.41 1.0 -0.59
4 4 .44 2 .37 4 00 normes 4 82 18 34 20
1 83 .05 .05 .05 0
- 16 16 16 13 8 -
P1 2 4 6 133. PDC à des 0.5 0. 1. 1. 1.
133 16.50 0. 502 0 502 0 502 524 313 0.00 0.79 1.0 -0.21
5 4 .74 2 .37 7 00 normes 4 82 18 37 34
1 75 .67 .67 .67 0
- 16 16 16 13 7 -
P1 2 4 4 115. PDC à des 0.5 0. 1. 1. 1.
115 16.50 0. 502 0 502 0 502 058 031 0.00 0.27 1.0 -0.73
6 4 .63 2 .57 9 00 normes 4 82 18 33 14
1 87 .67 .67 .67 0
- 16 16 16 13 8 -
P1 2 4 7 136. PDC à des 0.5 0. 1. 1. 1.
136 16.50 0. 502 0 502 0 502 590 494 0.00 0.89 1.0 -0.11
7 4 .43 2 .02 0 00 normes 4 82 18 38 37
1 74 .67 .67 .67 0
ITSA ZRAIB 2021/2022
Royaume du Maroc
WAAET
- 16 16 16 13 8 -
P1 3 4 8 158. PDC à des 0.5 0. 1. 1. 1.
158 16.50 0. 502 0 502 0 502 369 982 0.00 1.34 1.0 0.34
8 0 .25 2 6 00 normes 4 82 18 36 45
1 63 .67 .67 .67 .46 0
- 16 16 16 13 8 -
P1 2 4 6 133. PDC à des 0.5 0. 1. 1. 1.
133 16.50 0. 502 0 502 0 502 524 313 0.00 0.79 1.0 -0.21
9 4 .74 2 .37 7 00 normes 4 82 18 37 34
1 75 .67 .67 .67 0
- 16 16 16 13 9 -
P2 2 4 8 147. PDC à des 0.5 0. 1. 1. 1.
147 16.50 0. 502 0 502 0 502 808 093 0.00 1.26 1.0 0.26
0 4 .35 2 1 00 normes 4 82 18 40 47
1 68 .67 .67 .67 .31 0
- 16 16 16 13 9 -
P2 3 4 9 162. PDC à des 0.5 0. 1. 1. 1.
162 16.50 0. 502 0 502 0 502 446 168 0.00 1.48 1.0 0.48
1 0 .62 2 .15 0 00 normes 4 82 18 37 48
1 62 .67 .67 .67 0
- 16 16 16 13 8 -
P2 3 4 8 158. PDC à des 0.5 0. 1. 1. 1.
158 16.50 0. 502 0 502 0 502 369 982 0.00 1.34 1.0 0.34
2 0 .25 2 6 00 normes 4 82 18 36 45
1 63 .67 .67 .67 .46 0
- 16 16 16 12 8 -
P2 4 4 9 181. PDC à des 0.5 0. 1. 1. 1.
181 16.50 0. 502 0 502 0 502 673 843 0.00 1.54 1.0 0.54
3 2 .32 2 .97 7 00 normes 4 82 18 29 43
1 55 .67 .67 .67 0
- 16 16 16 13 9 1 -
P2 4 4 203. PDC à des 0.5 0. 1. 1. 1.
203 16.50 0. 502 0 502 0 502 088 186 1 0.00 2.06 1.0 1.06
4 2 .32 8 .21 3 00 normes 4 82 18 33 48
1 49 .67 .67 .67 0
14
45 30 21 1 9
69 76
Qmax par diamétre 520 0 211. 0 019 01 289 1 837
0 3.
.09 24 .82 4 .14
44
0 0 1
69
Longueur Total par diamétre + . . 01 1
0.
Majoration 5% 0 0 4. 837.05
05
5 5 05
ITSA ZRAIB 2021/2022
Royaume du Maroc
WAAET
Conduites principales :
Conduites principales :
3
Tronçon Débit (m /h) DN (mm) DI (mm) Vitesse (m/s)
ST-S1 49.51 125 117.6 1.27
ST-S2 49.51 125 117.6 1.27
ST-S3 49.51 125 117.6 1.27
ST-S4 49.51 125 117.6 1.27
ST-S5 49.51 125 117.6 1.27
ST-S6 49.51 125 117.6 1.27
ST-S7 49.51 125 117.6 1.27
ST-S8 49.51 125 117.6 1.27
P15 ST-V15 166.00 49.51 125.0 117.6 2.10 -1.00 12.88 11.78
P16 ST-V16 166.00 49.51 125.0 117.6 2.10 -1.00 12.36 11.26
P17 ST-V17 166.00 49.51 125.0 117.6 2.10 -1.00 12.98 11.88
P18 ST-V18 166.00 49.51 125.0 117.6 2.10 -1.00 13.42 12.32
P19 ST-V19 166.00 49.51 125.0 117.6 2.10 -1.00 14.11 13.02
P20 ST-V20 166.00 49.51 125.0 117.6 2.10 -1.00 13.43 12.33
P21 ST-V21 166.00 49.51 125.0 117.6 2.10 -1.00 13.64 12.54
P22 ST-V22 166.00 49.51 125.0 117.6 2.10 -1.00 13.50 12.40
P23 ST-V23 166.00 49.51 125.0 117.6 2.10 -1.00 13.70 12.60
P24 ST-V24 166.00 49.51 125.0 117.6 2.10 -1.00 14.04 12.94
Pression max à la
16.47 mCE
sortie de la station
Pressions minimales et maximales aux goutteurs pour une pression à l’aval immédiat de la station de
tête de mCE :
Pressions minimales et maximales aux goutteurs pour une pression à l’aval immédiat de la station
de tête de mCE
Pression Max à la sortie de station 16.47
5. Groupe motopompe :
La pompe de surface
La hauteur totale.
La pression souhaitée.
Les pertes de charges.
La puissance de la pompe :
Pp = (Q*HMT*ρ*g)/ (3600*µp)
Pp : la puissance de la pompe en KW
Q : le débit de secteur en m3/s
HMT : la hauteur manométrique totale en m
ρ : la masse volumique de l’eau en kg/l
g : l’accélération (9,81 N/Kg)
µp : le rendement de pompe en pourcentage %.
Pm = Pp/ µm
Pm : la puissance du moteur en KW
Pp : la puissance de la pompe en KW
µm : le rendement du moteur en pourcentage %
la conversion du KW au CV : 1KW = 1,35 CV
Station de pompage
Pompe de surface du bassin
Pression à l'aval immédiat de la station de tête 16.47 mCE
Perte de charges maximales au niveau de la station de tête 10.00 mCE
Hauteur d'aspiration 4.00 m
Débit du secteur 49.51 m3/h
Hauteur Manométrique Total 30.47 m
Puissance de la pompe 6.80 Kw
Puissance du moteur 8.50 Kw
Puissance de la pompe 9.24 Cv
Puissance du moteur 11.49 Cv
6. Dimensionnement de bassin :
Vutile = Jrsauto*Bp*Sirrig
Talus : 1/1
Profondeur de bassin : 4m
Revanche : 0,5m
IV. Conclusion :
1ére activité est l’étude du projet d’irrigation par le système d’irrigation localisé « goutte à
goutte ». Dans cette activité j’ai bien obtenu comment recueillir les données de base
nécessaire pour réaliser une étude technique, la réalisation de l’étude technique, et
comment choisir la pompe convenable à notre besoin (Q et HMT).
3éme activité est la préparation des dossiers des marchés publics (le dossier administratif, le
dossier technique, et le dossier financière).
V. Les annexes :
NOTECALCULE.ods
catalogue_pompes calpeda.pdf
PLAN.dwg