FONCTIONNEMENT
FLÈCHE
À
EXTENSION
SIMULTANÉE

(10-11-12-13-14-16 mètres)
Fermer

FLÈCHE REPLIÉE

DISTRIB. EXTENSION EXTERNE

EXTENSION INTERNE
Fermer

FLÈCHE EN PHASE D’EXTENSION

DISTRIB. EXTENSION EXTERNE

EXTENSION INTERNE
Fermer

FLÈCHE EN PHASE D'EXTENSION

DISTRIB.
EXTENSION EXTERNE

EXTENSION INTERNE
Fermer

FLÈCHE EN EXTENSION MAXIMALE

DISTRIB. EXTENSION EXTERNE

EXTENSION INTERNE
Fermer

FLÈCHE EN PHASE DE REPLI

DISTRIB. EXTENSION EXTERNE

EXTENSION INTERNE
Fermer

FLÈCHE EN PHASE DE REPLI

DISTRIB. EXTENSION EXTERNE

EXTENSION INTERNE
Fermer

FLÈCHE REPLIÉE

DISTRIB. EXTENSION EXTERNE

EXTENSION INTERNE
Fermer

PENDANT LA PHASE D'EXTENSION, LES VÉRINS DOIVENT ÊTRE


“SYNCHRONISÉS” À SAVOIR QU’ILS DOIVENT ATTEINDRE LA FIN DE
COURSE SIMULTANÉMENT.
CETTE CONDITION EST ESSENTIELLE PUISQUE L’ABSENCE DE
“SYNCHRONISATION” PEUT ENTRAÎNER LA RUPTURE DES TUYAUX
HYDRAULIQUES À L’INTÉRIEUR DE LA FLÈCHE.
COMMENT OBTENIR LA SYNCHRONISATION DES VÉRINS
D'EXTENSION?
Fermer

LA VANNE REPRÉSENTÉE EST FIXÉE SUR LE CULOT DES DEUX


VÉRINS ET DANS LE CAS OÙ CES DERNIERS N’ATTEINDRAIENT PAS
LA FIN DE COURSE SIMULTANÉMENT, ELLE PERMET À L’HUILE DE
CIRCULER ET AU VÉRIN “RETARDATAIRE” D’ARRIVER EN FIN DE
COURSE ET DE REVENIR “EN SYNCHRONISATION”
Fermer

DURANT LA PHASE D'EXTENSION OU DE REPLI, LES VANNES


N’INFLUENCENT PAS L’OPÉRATION PUISQU’ELLES SONT MAINTENUES
FERMÉES PAR LA PRESSION PRÉSENTE DANS LES DEUX CHAMBRES.
Fermer

L’ÉVENTUEL DÉFAUT DE “SYNCHRONISATION” DE LA FLÈCHE PEUT


POSER DES PROBLÈMES UNIQUEMENT EN PHASE DE RETOUR, EN
PARTICULIER QUAND LA SECONDE EXTENSION EST EN “RETARD”.
CETTE SITUATION PROVOQUE GÉNÉRALEMENT LA RUPTURE DES
TUYAUX HYDRAULIQUES CONTRE LE BORD DE LA PREMIÈRE
EXTENSION DÉJÀ ENTIÈREMENT REPLIÉE.
Fermer

DANS LE CAS OÙ LA FLÈCHE NE SE SYNCHRONISERAIT PAS


AUTOMATIQUEMENT, IL EST VIVEMENT RECOMMANDÉ DE CHANGER LES
DEUX VANNES SANS ATTENDRE POUR PRÉVENIR LES RISQUES DE
RUPTURES INDÉSIRABLES ET COÛTEUSES.