Vous êtes sur la page 1sur 2

Summary Geotechnical Analysis

(CIRCULAR PILE 350 x 350)


Borehole Layout
Ref: Final Report Soil Investigation Kavling F - SEZ Sei Mangkei PT INL

N-SPT Value
Borehole ID
Depth (m) DH-1 DH-2 DH-3 DH-4 DH-5 DH-6 DH-7 DH-8 DH-9 DH-10
NSPT
2 2 2 3 4 3 2 3 2 2 3
4 3 3 2 4 2 4 4 4 4 4
6 4 5 4 4 4 4 4 3 5 3
8 4 3 3 6 3 7 5 5 4 5
10 7 3 5 6 5 6 6 4 6 4
12 13 8 8 9 6 8 8 8 8 7
14 60 60 60 60 60 60 60 60 9 60
16 60 60 60 60 60 60 60 60 60 60
18 60 60 60 60 60 60 60 60 60 60
20 60 60 60 60 60 60 60 60 60 60
22 60 60 60 60 60 60 60 60 60 60
Summary Geotechnical Analysis
(CIRCULAR PILE 350 x 350)

Pile Capacity
Safety Factor Skin Resistance 2.5 (SNI 8460:2017)
Safety Factor End Bearing 2.5 (SNI 8460:2017)
For driven pile, axial capacity is calculated by APILE Ensoft with API formula and for Bored Pile,
it is calculated manually with Reese & Wright formula.
Lateral pile capacity is calculated by LPILE Ensoft with allowable deflection (SNI 8460:2017) for
nominal earthquake load 12mm. Assumption 30% capacity reduction due to pile configuration
has been considered for lateral capacity.
All Comp Capacity (kN) All Tens Capacity (kN)
Borehole Borehole
Pile Length 350 Pile Length 350
No. No.
(m) CSP (m) CSP
DH-1 14 497 DH-1 14 246
DH-2 14 522 DH-2 14 237
DH-3 14 446 DH-3 14 204
DH-4 14 453 DH-4 14 219
DH-5 14 456 DH-5 14 212
DH-6 14 500 DH-6 14 231
DH-7 14 434 DH-7 14 217
DH-8 14 493 DH-8 14 225
DH-9 14 414 DH-9 14 207
DH-10 14 350 DH-10 14 172

Nominal Eq Load (12mm) Nominal Eq Load (12mm)


Free Head Fixed Head
All Lat Capacity (kN) All Lat Capacity (kN)
Borehole Borehole
Pile Length 350 Pile Length 350
No. No.
(m) CSP (m) CSP
DH-1 14 14 DH-1 14 16
DH-2 14 14 DH-2 14 16
DH-3 14 14 DH-3 14 28
DH-4 14 20 DH-4 14 43
DH-5 14 18 DH-5 14 17
DH-6 14 14 DH-6 14 16
DH-7 14 18 DH-7 14 17
DH-8 14 14 DH-8 14 16
DH-9 14 14 DH-9 14 16
DH-10 14 19 DH-10 14 17

Vous aimerez peut-être aussi