N-SPT Value
Borehole ID
Depth (m) DH-1 DH-2 DH-3 DH-4 DH-5 DH-6 DH-7 DH-8 DH-9 DH-10
NSPT
2 2 2 3 4 3 2 3 2 2 3
4 3 3 2 4 2 4 4 4 4 4
6 4 5 4 4 4 4 4 3 5 3
8 4 3 3 6 3 7 5 5 4 5
10 7 3 5 6 5 6 6 4 6 4
12 13 8 8 9 6 8 8 8 8 7
14 60 60 60 60 60 60 60 60 9 60
16 60 60 60 60 60 60 60 60 60 60
18 60 60 60 60 60 60 60 60 60 60
20 60 60 60 60 60 60 60 60 60 60
22 60 60 60 60 60 60 60 60 60 60
PILE CAPACITY SUMMARY
(SQUARE PILE 250 x 250)
Pile Capacity
Safety Factor Skin Resistance 2.5 (SNI 8460:2017)
Safety Factor End Bearing 2.5 (SNI 8460:2017)
For driven pile, axial capacity is calculated by APILE Ensoft with API formula and for Bored Pile,
it is calculated manually with Reese & Wright formula.
Lateral pile capacity is calculated by LPILE Ensoft with allowable deflection (SNI 8460:2017) for
service load 6mm. Assume 30% capacity reduction due to pile configuration has been
considered for lateral capacity.