Académique Documents
Professionnel Documents
Culture Documents
GEHC_FRNT_CVR.FM
GE
LOGIQ P9 / P7
Software Option Installation Instruction
Important Precautions
- i
GE PROPRIETARY TO GE
DIRECTION 5736189, REVISION 2 LOGIQ P9/P7 - SOFTWARE OPTION INSTALLATION INSTRUCTION
ii -
GE PROPRIETARY TO GE
DIRECTION 5736189, REVISION 2 LOGIQ P9/P7 - SOFTWARE OPTION INSTALLATION INSTRUCTION
- iii
GE PROPRIETARY TO GE
DIRECTION 5736189, REVISION 2 LOGIQ P9/P7 - SOFTWARE OPTION INSTALLATION INSTRUCTION
iv -
GE PROPRIETARY TO GE
DIRECTION 5736189, REVISION 2 LOGIQ P9/P7 - SOFTWARE OPTION INSTALLATION INSTRUCTION
- v
GE PROPRIETARY TO GE
DIRECTION 5736189, REVISION 2 LOGIQ P9/P7 - SOFTWARE OPTION INSTALLATION INSTRUCTION
vi -
GE PROPRIETARY TO GE
DIRECTION 5736189, REVISION 2 LOGIQ P9/P7 - SOFTWARE OPTION INSTALLATION INSTRUCTION
- vii
GE PROPRIETARY TO GE
DIRECTION 5736189, REVISION 2 LOGIQ P9/P7 - SOFTWARE OPTION INSTALLATION INSTRUCTION
(JA)
Traditional
Chinese
viii -
GE PROPRIETARY TO GE
DIRECTION 5736189, REVISION 2 LOGIQ P9/P7 - SOFTWARE OPTION INSTALLATION INSTRUCTION
(ZH-CN)
(KO)
- ix
GE PROPRIETARY TO GE
DIRECTION 5736189, REVISION 2 LOGIQ P9/P7 - SOFTWARE OPTION INSTALLATION INSTRUCTION
DAMAGE IN TRANSPORTATION
All packages should be closely examined at time of delivery. If damage is apparent write “Damage In
Shipment” on ALL copies of the freight or express bill BEFORE delivery is accepted or “signed for” by
a GE representative or hospital receiving agent. Whether noted or concealed, damage MUST be
reported to the carrier immediately upon discovery, or in any event, within 14 days after receipt, and the
contents and containers held for inspection by the carrier. A transportation company will not pay a claim
for damage if an inspection is not requested within this 14 day period.
The purchaser of GE equipment shall only utilize qualified personnel (i.e., GE’s field engineers,
personnel of third-party service companies with equivalent training, or licensed electricians) to perform
electrical servicing on the equipment.
GE Healthcare employees should contact the product's Lead Service Integrator (LSI) to report service
documentation issues. DO NOT use TrackWise for this purpose. The LSI will then use the internal
problem reporting tool to communicate these issues to the writer.
x -
GE PROPRIETARY TO GE
DIRECTION 5736189, REVISION 2 LOGIQ P9/P7 - SOFTWARE OPTION INSTALLATION INSTRUCTION
LEGAL NOTES
The contents of this publication may not be copied or duplicated in any form, in whole or in part, without
prior written permission of GE.
GE may revise this publication from time to time without written notice.
PROPRIETARY TO GE
Permission to use this Advanced Service Software and related documentation (herein called the
Material) by persons other than GE employees is provided only under an Advanced Service Package
License relating specifically to this Proprietary Material. This is a different agreement from the one under
which operating and basic service software is licensed. A license to use operating or basic service
software does not extend to or cover this software or related documentation.
If you are a GE employee or a customer who has entered into such a license agreement with GE to use
this proprietary software, you are authorized to use this Material according to the conditions stated in
your license agreement.
However, you do not have the permission of GE to alter, decompose or reverse-assemble the software,
and unless you are a GE employee, you may not copy the Material. The Material is protected by
Copyright and Trade Secret laws; the violation of which can result in civil damages and criminal
prosecution.
If you are not party to such a license agreement or a GE Employee, you must exit this Material now.
TRADEMARKS
All products and their name brands are trademarks of their respective holders.
COPYRIGHTS
All Material Copyright© 2017 by General Electric Company Inc. All Rights Reserved.
- xi
GE PROPRIETARY TO GE
DIRECTION 5736189, REVISION 2 LOGIQ P9/P7 - SOFTWARE OPTION INSTALLATION INSTRUCTION
Revision History
Date
Revision (YYYY/MM/DD) Reason for change
1 2016/02/25 Initial Release
2 2017/01/12 Add to contents for GT and Perfusion
xii -
GE PROPRIETARY TO GE
DIRECTION 5736189, REVISION 2 LOGIQ P9/P7 - SOFTWARE OPTION INSTALLATION INSTRUCTION
Chapter 1
Introduction
Section 1-1
Introduction
This manual describes the software installation manual for LOGIQ P9/P7 R2/R2.5.
This manual does not cover operations such as obtaining key codes from OKOS system.
Section 1-2
Additional Parts Required
None, but access to OKOS (Option Key Order System) needed to obtain an option key.
Section 1-3
Tools Required
Probes or Printers may be needed for functionality check.
Section 1-4
Kit Applicable to
Kits applicable to LOGIQ P9/P7 R2/R2.5.
Chapter 1 - Introduction 1
GE PROPRIETARY TO GE
DIRECTION 5736189, REVISION 2 LOGIQ P9/P7 - SOFTWARE OPTION INSTALLATION INSTRUCTION
Section 1-5
General Description
Not all features or products described in this document may be available or cleared for sale in all
markets.
Software Options
Displays the needle's position in real-time graphics that are overlaid on the
Pinpoint GT image of the scan plane. The trajectory can then be monitored as it progresses
toward the target.
NOTICE The illustration in this manual shows the status of a temporary option, like those generated for Demos.
Make sure that the options purchased by the customer show status: “Permanent”.
2 Chapter 1 - Introduction
GE PROPRIETARY TO GE
DIRECTION 5736189, REVISION 2 LOGIQ P9/P7 - SOFTWARE OPTION INSTALLATION INSTRUCTION
Chapter 2
Working with Option Key
READ and UNDERSTAND these instructions thoroughly before proceeding with the installation.
Perform each step in sequence and check it off when completed. If a problem occurs after completion,
go back through the procedures and check for implementation errors before contacting your Ultrasound
Region Engineer.
Section 2-1
Accessing Option Key
1.) Turn system power ON.
2.) From the touch panel, select "Utility"->"Admin".
3.) When prompted with Title Login dialog, select "ADM" as operator and enter appropriate Password.
Section 2-2
Verifying Installed Option Key
1.) Examine text under "Installed Option Keys".
Section 2-3
Adding Option
1.) Enter option key from OKOS in SW Option Key section.
Section 2-4
Verifying Available Option
1.) Examine an option list on the right pane.
Chapter 3
Functional Check
In addition to the Option check perform following functional check to verify software option has been
correctly installed.
Section 3-1
Cardiac AFI
Required Tool/Probe: 3Sc-RS, 6S-RS
Figure 3-1
Section 3-2
STIC
Required Tool/Probe: RAB2-6-RS, RIC5-9A-RS
Figure 3-2
Figure 3-3
2 Chapter 3 - Functional Check
GE PROPRIETARY TO GE
DIRECTION 5736189, REVISION 2 LOGIQ P9/P7 - SOFTWARE OPTION INSTALLATION INSTRUCTION
Section 3-3
Omniview
Required Tool/Probe: RAB2-6-RS, RIC5-9A-RS
Figure 3-4
Figure 3-5
Chapter 3 - Functional Check 3
GE PROPRIETARY TO GE
DIRECTION 5736189, REVISION 2 LOGIQ P9/P7 - SOFTWARE OPTION INSTALLATION INSTRUCTION
Section 3-4
Pinpoint GT
Required Tool/Probe: L12n-RS
Figure 3-6
Section 3-5
Perfusion - Europe
LP7 only
Required Tool/Probe: 9L-RS
Figure 3-7