Vous êtes sur la page 1sur 266

Tender Inviting Authority:SUPERINTENDING ENGINEER, CONSTRUCTION CIRCLE, UP JAL NIG

Name of Work: MORADABAD NAGAR NIGAM REORGANIZATION WATER SUPPLY SCHEME UN


Contract No: NIT NO. 611/NIVIDA/74, Dated 04.03.2023
NUMBER #

Sl.
No.

1
1.01

1.02

1.03

1.04
1.05

1.06

1.07

2.01

3
3.01

3.02

3.03

3.04

4.01
4.02

4.03

6.01

6.02
6.03

6.04

7.01

7.02

7.03
8

10

11

12

12.01
12.02

12.03

12.04

12.05

12.06

12.07
12.08

12.09

12.1

12.11

12.12

13
13.01

13.02

13.03

13.04

13.05

13.06
13.07

13.08

14

15

16

17
18

18.01

18.02

18.03

18.04

19
19.01

19.02

19.03

19.04

20

20.01
20.02

20.03

20.04

20.05

20.06

20.07
20.08

20.09

20.1

20.11

20.12

21
21.01

21.02

21.03

21.04

21.05

21.06
21.07

21.08

22

23

24

25
25.01

25.02

26

27

28

29
30

31

32

32.01

32.02

32.03
32.04

32.05

32.06

32.07

32.08

32.09
32.10

32.11

32.12

32.13

32.14

32.15
32.16

32.17

32.18

32.19

32.20

32.21
32.22

32.23

32.24

32.25

32.26

32.27
32.28

32.29

32.30

33

34

35
36

37

38

39

39.01

39.02
39.03

39.04

39.05

40

40.01

40.02
40.03

40.04

40.05

41

41.01

41.02
41.03

41.04

41.05

42

42.01

42.02
42.03

42.04

42.05

43

43.01

43.02
43.03

43.04

43.05

44

45

46
46.01

46.02

46.03

46.04

46.05

47
47.01

47.02

47.03

47.04

47.05

47.06
47.07

47.08

47.09

47.10

47.11

47.12
47.13

47.14

47.15

48

48.01

48.02
48.03

48.04

48.05

48.06

48.07

48.08
48.09

48.1

48.11

48.12

48.13

48.14
48.15

48.16

48.17

48.18

48.19

48.2
48.21

48.22

48.23

48.24

49

50
50.01

50.02

50.03

51

51.01

51.02
52

52.01

53

53.01

53.02

53.03
54

54.01

54.02

54.03

55

55.01
55.02

55.03

55.04

55.05

56

56.01
56.02

56.03

56.04

57

57.01

57.02
57.03

57.04

58

58.01

58.02

58.03
58.04

59

59.01

60

60.01

61
61.01

62

62.01

62.02

63

63.01
63.02

63.03

63.04

63.05

63.06

63.07
63.08

63.09

64

65

66

66.01
66.02

66.03

66.04

66.05

66.06

66.07
66.08

66.09

66.1

66.11

66.12

66.13
66.14

66.15

67

67.01

67.02

67.03
67.04

67.05

67.06

67.07

67.08

67.09
68

68.01

68.02

68.03

68.04

68.05
68.06

68.07

68.08

68.09

68.10

68.11
68.12

68.13

68.14

69

69.01

70
70.01

70.02

70.03

70.04

70.05

71
71.01

71.02

71.03

72

73

74
75

76

77

78

78.01

79
79.01

79.02

79.03

80

80.01

80.02
80.03

80.04

81

82

82.01

82.02
82.03

82.04

82.05

82.06

82.07

83
83.01

83.02

83.03

83.04

84

84.01
84.02

84.03

84.04

84.05

84.06

84.07
85

85.01

85.02

85.03

85.04

85.05
85.06

85.07

85.08

85.09

85.10

86
86.01

86.02

87

87.01

88

Total in Figures
Quoted Rate in Figures
Quoted Rate in Words
er Inviting Authority:SUPERINTENDING ENGINEER, CONSTRUCTION CIRCLE, UP JAL NIGAM (URBAN), M
e of Work: MORADABAD NAGAR NIGAM REORGANIZATION WATER SUPPLY SCHEME UNDER AMRUT 2.
ract No: NIT NO. 611/NIVIDA/74, Dated 04.03.2023
TEXT #

Item Description

2
Supply of all the materials, labour T&P and construction of a R.C.C. Over head tank above groun
components, based on IS-3370 or liquid storage concrete in over head tank and foundation concrete a
in I.S. 2911.
All Components of OHT will be casted in M-30 concrete with cement, coarse sand and approved sto
11682 and I.S. 456.
The steel for RCC shall be epoxy coated TMT bars- Fe 500/415 as per IS code IS 2062:2011.
Minimum depth of foundation below original ground level will be 2.0 M.
Seismic effects and wind load should be taken into consideration as I.S. 1893 for earthquake resist
part-III for wind load on structure.
The assumed bearing capacity of soil has been taken as 8 M.T. sqm.
1m wide RCC stair case from ground lavel to balcony.
M.S. ladder made of 50 X 50 X 6 mm angle section and 20 mm plain M.S. bars (specification of M.S. s
800-2007) with hand rails of 20 mm medium class G.I. pipes on both sides in three rows from balcony t
on an RCC platform (75 X 75 cm and 10 cm thick) projecting from top ring beam and one aluminium
tank body ( from manhole in top dome to bottom dome).
1 m wide R.C.C. balcony around the tank at the junction point of vertical wall and conical wall.
Proper R.C.C. railing and 20 mm dia medium class G.I. pipe (in 3 rows) on both sides of stair case, ar
at each landing from landing with top ring beam upto manhole on the top dome and at the periphery.
be supported on R.C.C. posts of 100 mm dia or on the posts made of 50 X 50 X 6 mm M.S. angle
intervals not more than 1.5 m.
Proper ventilator at top dome in circular shape of 1.2 m dia along with an R.C.C. cover of minimum 1.50
thickness, pillar of ventilator should be minimum 50 cm dia. The space between top dome and R.C.C
covered with mosquito net of standard quality along with expanded metaled jali.
Supply, fixing, jointing of following size of D.I. D/F Pipes with D.I. D/F specials conforming to IS 8329
pipes for inlet, outlet, over flow and washout as per latest / relevent I.S. specifications with all jointing m
completion of work including other appurtenant works and excavation in all types of soil.
Zone-1:- Inlet 300 mm & 250 mm Outlet 600 mm, Over flow 300mm & Wash out 100 mm.
Zone-2:- Inlet 300 mm & 250 mm Outlet 500 mm, Over flow 250mm & Wash out 100 mm.
Zone-3:- Inlet 300 mm & 250 mm Outlet 350 mm, Over flow 250mm & Wash out 100 mm.
Zone-4:- Inlet 300 mm & 250 mm Outlet 450 mm, Over flow 200mm & Wash out 100 mm.
Zone-5:- Inlet 350 mm , Outlet 600 & 500 mm, Over flow 350mm & Wash out 100 mm.
Zone-7:- Inlet 200 mm & 200 mm Outlet 300 mm, Over flow 200mm & Wash out 100 mm.
Supply and Fixing of following sizes D.I. D/F sluice valves with hand wheels as per I.S.S. 700/1969 or
10 kg/sqcm including cartage from its store to the site of work, lowering them into trenches, fixing in pos
complete.
Zone-1:- Inlet 300 mm & 250 mm Outlet 600 mm & Wash out 100 mm
Zone-2:- Inlet 300 mm & 250 mm Outlet 500 mm & Wash out 100 mm
Zone-3:- Inlet 300 mm & 250 mm Outlet 350 mm & Wash out 100 mm.
Zone-4:- Inlet 300 mm & 250 mm Outlet 450 mm & Wash out 100 mm.
Zone-5:- Inlet 350 mm , Outlet 600 & 500 mm & Wash out 100 mm.
Zone-7:- Inlet 200 mm & 200 mm Outlet 300 mm & Wash out 100 mm.
Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit under each
support the vertical pipes. These bed blocks should supported on the raft not on the soil.
Construction of surface box type Sluice valve chamber for above sluice valve (3 No.) as per departm
and drawing including supply and fixing of 150 mm x 150 mm size C.I. surface box including locking arr
Construction of washout/ overflow chamber as per departmental type design and drawing.
Construction of P. C. C. Floor & Drain and all other necessary work as per departmental type drawing a
Painting of all concrete surface and steel pipe worrks with three coats of approved cement paint and an
Testing & Commission etc. all complete work.
Testing and submission of test report of bearing capacity of soil from a recognized Govt. institute.
Submission of 5 sets of detailed design and drawing of O.H.T and mix design of M30 concrete done a
of the department from any IIT's/Central University as per direction of Engineer-in -charge.
The design of tank & foundation will be based upon the soil investigation report which shall be don
institute.
2400 KL / 22.0 M Staging (ZONE-01)

2800 KL / 20.0 M Staging (ZONE-02)

1400 KL / 20.0 M Staging (ZONE-03)


2000 KL / 20.0 M Staging (ZONE-04)

2500 KL / 24.0 M Staging (ZONE-05)

1100 KL / 18.0 M Staging (ZONE-07)

CWR-CUM PUMP HOUSE


Supply of all materials, labour and T&P etc. complete for the construction of Ground RCC Clear
House.Including Pump House.
Testing of bearing capacity of soil from a recognized Govt. Engineering College or as directed by depar

1000 KL (ZONE-05)

RISING MAIN
Supply of the following sizes of D.I. pipes Class K-7 conforming to latest I.S. 8329/2000 and D.I. S/S o
conforming to I.S. 8329/2000 Suitable for above C.I.S/S pipe F.O.R destination from tubewell to OHT
including all Taxes and insurance. complete in all respect.
200 mm dia K-7

250mm dia K-7

300mm dia K-7

350mm dia K-9

Supply of the following sizes of Electro operated sluice valves as per I.S. 780/1969 class-1 working pr
F.O.R Destination including all taxes and Insurance.

200mm. dia.
250mm dia

300mm dia

Excavation for DI pipe line trenches in ordinary soil,(lime, clay or sand including lift up to 1.5m and le
refilling, watering, ramming of excavated earth in to trenches and disposal of surplus earth up to 50 m
the foundation trenches.

Carting from the store (up to 8 Km.) The following sizes of D.I. double pipe and specials to the site of w
into trenches and laying true to alignment and gradient including jointing, testing of pipeline and in
jointing material such as nut & bolts, rubber insertion, white lead etc. complete but excluding cost of tre
of pipes etc. For making of lengths but including making joints.

200 mm dia K-7

250mm dia K-7


300mm dia K-7

350mm dia K-9

Carting of D/F Sluice valves of following sizes to the site of works lowering them into already prep
fixing them In position including supply of jointing materials such as bolt nut, rubber insertion wh
excluding valves and specials required but including the testing etc. complete .

200 mm dia

250 mm dia

300 mm dia
Supply of all materials, labour T&P etc. required to construct masonry type sluice valves chamber a
including supply and materials labour, T&P etc. complete.

Supply of all materials, labour, T & P etc. required and construct thrust blocks at the bends and below th

Dismentaling of following type of surface including sorting out and staking of serviceable material
unserviceable materials up to a distance of 50 m
bituminous road

Reinstatement of following type of surface including sorting out and staking of serviceable materia
unserviceable materials up to a distance of 50 m
Bituminous Roads with granule sub base (G1-100mm, G2-75mm, G3-75mm thick), 50mm thick bitu
over priming coat and tack coat and 30mm thick SDBC/BC over tack coat & disposal of all debris a
within 8 Km. distance as per direction of Engineer-in-charge, including all materials,labour,T&P etc com

DISTRIBUTION SYSTEM
Supply of the following sizes of DI K-7 & HDPE pipes(PN-6, PE-100) confirming to latest releva
DI/HDPE Specials conforming to I.S.- 8329/2000 and I.S.- 4984/2016 respectively etc complete in
destination including all taxes and insurance.

600 mm dia DI K-7


500 mm dia DI K-7

450 mm dia DI K-7

400 mm dia DI K-7

350 mm dia DI K-7

300 mm dia DI K-7

250 mm dia DI K-7


200 mm dia DI K-7

160 mm dia HDPE PN-6/PE100

140 mm dia HDPE PN-6/PE100

125 mm dia HDPE PN-6/PE100

110 mm dia HDPE PN-6/PE100

Supply of the following sizes of Hand Wheel operated with Sluice Valves destination including all taxes
400 mm dia

350 mm dia

300 mm dia

250 mm dia

200 mm dia

150 mm dia
125 mm dia

100 mm dia

Supply of 100mm dia C.I. Double flanged scour valves as per I.S. 780 class-1 working pressure 1
Destination including all taxes and insurance.

Supply of 25 mm dia screwed down type air valve with gun metal seat at site stone including all taxes.

Supply of underground sluice valves type fire hydrant consisting of 80 mm dia tail pieces, 80 mm dia d
63 mm dia standard make iron coupling with cap and chain etc. complete to ISS 909 at site including al

Excavation for pipe line trenches in Ordinary soil,(lime, clay or sand Including lift up to 1.5m and lea
refilling, watering, Ramming of excavated earth in to trenches and disposal of surplus earth up to 50 m
the foundation trenches.
Dismantling of following type of surface including all layers, sorting out and staking of serviceable ma
of unserviceable materials up to a distance of 50 m.

B.O.E. ROAD

BITUMINOUS ROAD

C.C. ROAD

INTERLOCKING TILES ROAD

Reinstatement of following type of road surface.


B.O.E. Road with 40% new bricks and 60%used old bricks over 30mm compacted local s
materials,labour,T&P etc complete

Bituminous Roads with granule sub base (G1-100mm, G2-75mm, G3-75mm thick), 50mm thick bitu
over priming coat and tack coat and 30mm thick SDBC/BC over tack coat & disposal of all debris a
within 8 Km. distance as per direction of Engineer-in-charge, including all materials,labour,T&P etc com

C.C. Road will be prepared with 10 cm thick P.C.C. 1:2:4 Cement: Coarse Sand & 20 mm Stone grit o
15 cm. P.C.C. 1:4:8 with cement coarse sand & 40 mm stone ballast after compacting the earth sur
C.C. surface must be compacted with surface vibrator, including all materials,labour,T&P etc complete.

Interlocking Tile road: Tiles must be of the thickness & grade similar to that of the dismantled tiles ove
mm thick PCC 1:4:8 cement: coarse sand: stone ballast as per existing road. The thickness of tiles sha
of existing road, including all materials,labour,T&P etc complete.

Carting from the store (up to 8 Km.) the following sizes of D.I & HDPE pipe and specials to the site of w
in to trenches and laying true to alignment and gradient including jointing, testing of pipeline and in
jointing material such as nut & bolts, rubber insertion, white lead etc. complete but excluding cos
including making joints.

600 mm dia DI K-7


500 mm dia DI K-7

450 mm dia DI K-7

400 mm dia DI K-7

350 mm dia DI K-7

300 mm dia DI K-7

250 mm dia DI K-7


200 mm dia DI K-7

160 mm dia HDPE PN-6/PE100

140 mm dia HDPE PN-6/PE100

125 mm dia HDPE PN-6/PE100

110 mm dia HDPE PN-6/PE100

Carting of D/F Sluice valves of Following sizes to the site of works Lowering them into already Prep
fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white l
Excluding valve and specials Required but including the testing etc. complete
400 mm dia

350 mm dia

300 mm dia

250 mm dia

200 mm dia

150 mm dia
125 mm dia

100 mm dia

Carting of 100mm dia scour valves to the site of works lowering them into already Prepared trenches
position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete w
and specials required but including the testing etc. complete

Carting of 25 mm dia screwed down air valves of following sizes to the site of works lowering them into
trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber in
complete with excluding valves and specials required but including the testing etc. complete

Carting of 80 mm dia flanges fire hydrant to the site of works lowering them into already prepared t
them In position including supply of Jointing materials such as bolt nut, Rubber insertion white le
excluding valve and specials required but including the testing etc. complete

Supply of all materials, labour T&P etc. required and construct surface box/masonry type sluice / scour
per type design including supply and materials labour, T&P etc. complete.
Surface box type

Masonry type

Supply of all materials, labour T&P Etc. required and construct single tap pillar type stand post as per ty

Supply of all materials, labour T&P Etc. required and construct 350 x 350 x 500 mm size air valve ch
design including supply and fixing the 500 mm dia CI manhole cover.

Supply of all materials, labour T&P Etc. required and construct 750 x 750 x 1000 mm size fire hydra
type design including supply and fixing the 500 mm dia CI manhole cover.

Provision for Large crossing of raods, nala & culvert including shifting of telephone cable etc.along the
line including supply of C.I Tyton pipe and special and also jointing material their laying and jointing te
(More than 3.00 meter).
Provision for Small crossing of roads including shifting of telephone cable etc.along the alignment of
supply of C.I Tyton pipe and special and also jointing material their laying and jointing testing etc,com
meter).

Pump House cum chlorinating room

(3.60x3.00x3.00m) & (2.50x1.80x3.00m)

Excavation of earth in ordinary soil (loam or clay) including lift upto 1.5 m and lead upto 50 m.fil
ramming of excavated earth in between the building and sides of the foundation trenches or into the plin
surplus earth upto a distance of 50 m from the center of the foundation trenches.

Concrete with 40 mm gauge Ist class brick ballast,localsand and cement in proportion (8:4:1) in fo
supply of all materials, labour,T&P etc required for proper completion of work.

Ist class brick work in 1:6 cement and Coarse sand mortar in foundation and plinth including supp
labour,T&P etc required for proper completion of work.
150 mm thick RCC plinth band With cement and approved coarse sand with 20 mm stone gritt 1 :1.5:3
5% water proofing material, labour, T&P etc required for proper completion of work.

Ist class brick work in 1:6 cement and Coarse sand mortar in super structure including supply of all ma
etc required for proper completion of work.

Supply of M.S. Angle iron chaukhat of 40mm x 40mm size supply and fixing including simple moulding
chaukhat and also supply of all material, labour, T&P etc. required for proper completion of the work.

Supply and fixing of 1mm thick sheet iron panelled door, windows shutter including supply and fixing
hinges , bolts, locks, handles, springs and other fittings but excluding painting of fittings.

Supply and fixing of hold fast in doors and windows of size 25cm x 4cm x 9mm flat iron including
moulding and welding to required shape also including other material such as nails and screws etc. r
completion of the work.

R.C.C. Work cement,coarse sand and 20 mm gauge approved stone ballast in proper ratio of 1:1.5:3 e
reinforcement and its bending but including its fixing and binding the same with 0.5 mm thick binding w
by the contractor) centering and shuttering, curing, supply of all materials, labour,T&P etc required for
of work.
R.C.C in sun shade with cement,coarse sand and 20 mm gauge approved stone ballast in prop
including supply of reinforcement and it bending and including its fixing and binding its fixing in posit
curing, supply of all materials, labour,T&P etc required for proper completion of work.

R.C.C in lintel with cement,coarse sand and 20 mm gauge approved stone ballast in proper ratio o
supply of reinforcement and it bending and including its fixing and binding its fixing in position with
supply of all materials, labour,T&P etc required for proper completion of work.

R.C.C in slab with cement,coarse sand and 20 mm gauge approved stone ballast in proper ratio o
supply of reinforcement and it bending and including its fixing and binding its fixing in position with
supply of all materials, labour,T&P etc required for proper completion of work.

Mild steel or Iron work in plain work such as R.C.C. work shall be TMT bars- Fe 500/415 as per IS c
2062:2011, wrought to required shape as necessary including its bending and supply of steel,wastage
hooks etc complete required for proper completion of work.

Mild steel gril in windows, wrought to required heavy/ small size form including supply of all materia
Required for proper completion of the work.

Supply and lay complete 40 mm thick insulation layer of sand and clay over reinforcement brick or cem
Providing & laying of "Brick Coba" 12mm thick laid with first class brick bat Coba 7.50 cm thick with ga
(As per PWD specification) including supply of all materials , labour T&P etc. required for proper comple

12 mm thick plaster with cement coarse sand mortar in 1:6 (over brick work with 3 mm floating co
including supply of all materials, labour,T&P etc required for proper completion of work. From GL upto s

12 mm thick plaster with cement coarse sand mortar in 1:4 (over brick work with 3 mm floating co
including supply of all materials, labour,T&P etc required for proper completion of work on ceiling.

40 mm thick 1:2:4 plain cement concrete floor with cement,coarse sand and 20 mm gauge approved s
panel finished with 3 mm floating coat of neat cement and 7.5 cm thick base concrete consisting 1 pa
of coarse sand and 8 part 40 mm gauge stone ballast (1:4:8) and removing any over lapping of mo
panel if any and giving them uniform finished including supply material, labour,T&P etc required for pr
work.

Supply and fix 32 mm thick Flush door shutter/window shutters including supply and fixing a
hinges,bolt,locks,handles,spring and other fittings but excluding painting.

Supply and fixing of SS fitting of approved make for doors and windows.
Painting and varnishing of new iron work with one coat priming and two coat of approved paint and
supply of all materials, labour, T&P etc required for proper completion of work.

White washing of apex paint in three coat including supply of all materials, labour, T&P etc required for
of work.

Colour washing with weather coat for exterior and apex paint for interior in two coat over one prim
cement including supply of all materials, labour, T&P etc required for proper completion of work.

Provide and fixed RCC precast Jalies of 30 cm x 60 cm size including supply of all materials, labour, T&
proper completion of work.

Supply and fixing of rolled steel Joist 150 mm x 100 mm including its painting with approved paint an
primer.

Cartage & cost of earth work in filling in plinth including supply of excavated earth from distance of 8.00
Supply of all materials, labour, T&P etc. required for construction of 250 mm dia S.C. Drain.

Supply of all materials, labour, T&P etc. required for the construction of stilling / Byepass chamber
including supply of V notch etc. all complete.

Rain water down pipe 100 mm dia PVC with fixed MS clamp etc including supply of all materials
required proper completion of work.

Boundary Wall
Construction of Boundary wall 0.115 m thick and 1.5 m height with all materials, labour T&P etc. r
completion of work.

Construction of pillars as per type design including fixing of gate 3.6 m wide gate and 1.2 m wide w
materials, labour T&P etc. required for proper completion of work.
3.60 m wide gate with wicket gate.

Construction of pillars as per type design including fixing of 1.2 m wide wicket gate with all material
required for proper completion of work.
Construction of interlocking tile road with 80 mm thick M-30 grade tile (100% new) over base concrete
1:4:8, cement:coarse sand:stone ballast for approach road & water works campus with all material
required for proper completion of work.

Provision for inside square drain including supply of all materials labour and T & P etc. complete.

Making ferrule connection of various nominal dia of new distribution mains in different type of roads w
piece, service connections, fittings, and fixing of brass ferrule of 15mm size including tapping the mai
of excavation and subsequent backfill of trenchs and cost of fittings and specials, including labour c
threading & fitting of GI pipe and specials including supply of binding materials such as safeda an
Including making hole in the wall for crossing of GI pipe also repairing the same with mortar and also
of drain with all labour T&Petc. complete. including material i.e.3 meter 20mm dia (OD) HDPE Pipe
meter 20mm (OD) GI pipe Class-B, EL-bow 20mm (OD) GI for above pipe Class -B, Clamp with Sadd
(Brass) 15mm, Ferrule brass HDPE 15mm with end cap (heavy duty), 20 mm dia PP-Adopter and 20 m

FOR BOE ROAD

For 90mm to 110mm dia

For 125mm to 160mm dia


For 180mm to 250mm dia

For 300mm dia

For 350mm to 500mm dia

FOR CC ROAD

For 90mm to 110mm dia

For 125mm to 160mm dia


For 180mm to 250mm dia

For 300mm dia

For 350mm to 500mm dia

FOR BITUMINOUS ROAD

For 90mm to 110mm dia

For 125mm to 160mm dia


For 180mm to 250mm dia

For 300mm dia

For 350mm to 500mm dia

FOR INTERLOCKING TILES ROAD

For 90mm to 110mm dia

For 125mm to 160mm dia


For 180mm to 250mm dia

For 300mm dia

For 350mm to 500mm dia

FOR KACHHA ROAD

For 90mm to 110mm dia

For 125mm to 160mm dia


For 180mm to 250mm dia

For 300mm dia

For 350mm to 500mm dia

Variation in 20 mm (OD) dia HDPE Pipe w.r.t 3.0 mtr

Variation in 20 mm (OD) dia GI Pipe w.r.t 2.0 mtr

Construction of LCS/MCS Room


Excavation of earth in foundation in ordinary soil (loam, clay or sand) including lift upto 1.50m and le
refilling, watering, ramming of excavated earth into the space between the building and sides of foun
into the plinth and disposal of surplus earth upto the distance of 50m from the center of the foundation t

RCC with 10-12mm gauge approved stone ballast, coarse sand and cement in proportion of 1:1½:3 inc
materials, labour, T&P etc. required for proper completion of the work for column 350mm dia 5m h
beam and floor slab.

First class brick work with cement coarse sand in proportion 1:3 in foundation and plinth inclu
materials, labour, T&P etc. required for proper completion of the work.

First class brick work with cement coarse sand in proportion 1:3 in super structure including supp
labour, T&P etc. required for proper completion of the work.

20mm thick damp proof course (DPC) with cement and approved coarse sand 1:2 including waterproo
the proportion as specified by the manufacturers including supply of all materials, labour, T&P etc. r
completion of the work.

R.C.C. work with cement, coarse and 20mm gauge approved stone ballast in proportion 1:1½:3 in
excluding supply of reinforcement and its bending (but including its fixing and binding the same wi
binding wire) shuttering, centering and supply of all materials, labours T&P etc. required for proper com
Lintel and sunshades

Slab

Providing form work including centering, shuttering and propping etc. height of propping and centering
floor to ceiling not exceeding 4m and removal of the same for plain concrete work in walls.

Mild Steel or iron work in plain work such as reinforced concrete brick work (when not including in all o
TMT bars- Fe 500/415 as per IS code 1786:2008, IS 2062:2011 brought to required shape as ne
bending and cutting for proper completion of work including supply of steel and its wastage.

12mm thick plaster with cement and coarse sand mortar in 1:4 over brick work including supply of a
T&P etc. complete.

White wash of apex paint in three coats including supply all materials, labour, T&P etc. complete.
Colour washing with weather coat for exterior and apex paint for interior two coat using approve
including supply of all materials, labour, T&P etc. complete.

Supply and fix 32 mm thick Flush door shutter on doors and window including supply and fixing
hinges,bolt,locks,handles,spring and other fittings but excluding painting.

Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and bra
diagonal 20x5mm size with top and bottom rails of iron 40x40x6mm with 38mm dia steel pulley with
arrangements stopppers, supply and painting one coat of approved red lead paint.

Providing and fixing in position rolling shutters of approved make of 80x125mm gauge called rolled M.S
throughout their entire length and jointed together at the end by end locks and mounted on specially d
with branches shade girders and arrangement for inside and outside locking with push and pull opera
excluding the cost of top cover and spring.

Mild steel or iron work in small size and section such as holding down bolts, holdfasts, tie rods,
included in all over rates) wrought to required terms including suppply of steel bolts and wastage etc. th

Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8
work and including watering, dressing etc. complete.
Supply and fixing of exhaust fan including supply of all materials, labour, T&P etc. required for proper
work.

Supply and fixing of 150 mm, S.W. drain pipe including supply of all materials, labour, T&P etc. r
completion of the work.

Supply and fixing of 150mm dia A.C. pipe for comb including supply of all materials, labour, T&P etc. r
completion of the work.

Staff Quarter

Excavation of earth in ordinary soil (loam clay or and) including lift upto 1.5 m and lead upto 50 m.fi
ramming of excavated earth in between the building and sides of the foundation trenches or into the plin
surplus earth upto a distance of 50 m from the center of the foundation trenches.

Concrete with 40 mm gauge Ist class brick ballast,coarse sand and cement in proportion (8:4:1) in fo
supply of all materials, labour,T&P etc required for proper compltion of work.
Ist class brick work in 1:6 cement and local sand mortar in foundation and plinth including supp
labour,T&P etc required for proper compltion of work.

150 mm thick RCC plinth bend With cement and approved coarse sand with 20 mmm stone grit 1 :1.5
of 5% water proofing material, labour, T&P etc required for proper completion of work.

Ist class brick work in 1:6 cement and local sand mortar in super structure including supply of all ma
etc required for proper compltion of work.

Providing & lying of "Brick Coba" 12mm thick laid with M-150 class brick bat Coba 7.50 cm thick wit
each (As per PWD specification) including supply of all materials , labour T&P etc. required for proper
work.

Supply and fixing of door & Window chaukhat fabricated with 40 x 40 x 6 mm size angle iron or other
and T ron and MS fabricated with 203 cm, flat iron or well mess size as directed by Engineer- in-
include supply and fixing 3 hinges 10 cm size on each faced door and window with one coat of red ox
including carting, loading,unloading etc complete and also supply of all materials, labour,T&P etc comp

Supply and fix 32 mm thick Flush door shutter on doors and window including supply and fixing
hinges,bolt,locks,handles,spring and other fittings but excluding painting and supply of fitting.
R.C.C. Work cement,coarse sand and 20 mm gauge approved stone ballast in proper ratio of 1:1.5:3 e
reinforcement and it bending but including its fixing and binding the same with 0.5 mm thick binding w
by the contractor) centering and shuttering supply of all materials, labour,T&P etc required for proper co

R.C.C. Work in Lintel beam with cement,coarse sand and 20 mm gauge approved stone ballast in pro
excluding supply of reinforcement and it bending but including its fixing and binding the same with 0.5
wire (to be supply by the contractor) centering nd shuttering supply of all materials, labour,T&P etc r
compltion of work.

Mild steel or Iron work in plain work such as R.C.C. Work wrough to required shape as necessary inc
and supply of steel,wastage, over lapping and hooks etc complete required for proper completion of wo

12 mm thick plaster with cement local sand mortar in 1:4 (over brick work with 3 mm floating co
including supply of all materials, labour,T&P etc required for proper compltion of work. From GL upto su

Same as above but in proprtion 1:4 with cement and fine sand mortar on ceiling

40 mm thick 1:2:4 plan cement concrete floor with cement,coarse sand and 20 mm gauge approved s
panel finished with 3 mm loating coat of neat cement and 7.5 cm thick base concrete consisting 1 part o
local sand and 8 part ist class brick ballast 4 cm gauge (1:4:8) and removing any over lapping of m
panel if an and giving them uniform finished including supply material, labour,T&P etc required for pro
work.
Same as above but base concrete of 1:4:8 in cement , local sand and 40mm gauge first class brick ball

B.O.E. Flooring in 1:6 cement mortar over 75 mm thick brick ballast base concrete (1:4:8) and surface
court Yard. including supply material, labour,T&P etc required for proper completion of work.

Painting and varnishing of new iron work with one coat priming and two coat of approved paint and
supply of all materials, labour, T&P etc required for proper completion of work.

White washing in three coat including supply of all materials, labour, T&P etc required proper completio

Finishing walls with waterproof cement paint of approved make and quality over one priming coat on
coats to give an even shade including supply of all materials, labour, T&P etc. Required for proper
work.

Rain water down pipe 100 mm dia PVC with fixed MS clamp etc including supply of all materials
required proper completion of work.
Mild steel gril in windows, wrought to required form including supply of all materials,labour,T&P etc. R
completion of the work.

Supply and fixing of SS fitting of approved make for doors and windows.

Electrification work complete.

Sanitation work Water supply work complete.

E/M WORKS

CONSTRUCTION OF NEW/REBORE TUBEWELL (300x200mm dia) FOR ALL ZONES


Transportation, Erection, Dismantling of Rig Machine and its T&P

Transportation, Erection, Dismantling of Compressor 250/350 PSI

Transportation, Erection, Dismantling of 2 Cusec/ 3 Cusec O.P. Unit and Yield test

Supply of Tubewell Assembly


M.S.Tubewell assembly with all required parts like plain pipe, Slotted pipe (as required upto 50% of plain pipes
plug, clamp reducer, central guide, suport structure etc. as required & as per typed design complete in all respect.
(Note- Axial Length of Reducer without Ring shall be measured with casing pipe)

300 mm dia M.S. Pipe

200 mm dia M.S. Plain/slotted


PEA-GRAVEL (As per IS:4097)

1.65 mm to 4.50 mm size Pea gravel of Lalkuwan quarry duly screened, washed and properly s
Tubewell

Drilling of bore by rig machine As Per IS :2800(Part I & II):

Drilling of bore by 600 mm dia bit GL to 60 mt. BGL.

Drilling of bore by 500 mm dia bit from 60 mt GL to 100 mt. BGL.

Drilling of bore by 500 mm dia bit 100 m BGL to 165 m. BGL.


Lowering of tube well assembly With M.S. rings, Bail Plug, Reducer Including welding:

Lowering of 300 mm dia M.S. Housing pipe from GL to 50 m.BGL

Lowering of 200 mm dia M.S. Plain/slotted pipe 50 m. BGL to 100 m. BGL

Lowering of 200 mm dia M.S. Plain/slotted pipe 100 m. BGL to 150 m. BGL

Development of tube well by 250 PSI air compressor and 3 cusec O.P. Unit to yield sand free discharge

Development and testing of tube well by Air Compressor.


Development and testing of tube Well O.P.Unit to yield sand free Discharge.

Chemical and Bacteriological test (Analysis of water sample)

Site clearance before and after construction of Tubewell

Logging of borehole by departmental/approved electric logger

PUMPING PLANT OF 11NEW TUBEWELLS & 2REBORE TUBEWELLS, FEEDING TO OHT (Zone 1 t

Supply, Installation and Commissioning of 2000 Lpm 62 mt head (50 HP) Pumping Plant for OHT Co
including SCADA comptiable starter, Control Panal, Cable, complete in all respect with all required m
etc.
Supply, Installation and Commissioning of Main piping and valves with 150 mm dia Size 24 mtr. Co
wiring, earthing, Tools sets, Chain Pulley block and gauges complete in all respect with all required ma
(Sluice Valve Confirming to IS:14846-2000 & Reflex Valve Confirming to IS:5312

Additional Column Pipe 3 mtr long

Internal Electrification of pump house.

NEW PUMPING PLANT( 2 SET) OF TUBEWELLS FEEDING TO OHT (Zone-7)

Supply, Installation and Commissioning of 1500 Lpm 62 mt head (35 HP) Pumping Plant for OHT Co
including SCADA comptiable starter, Control Panal, Cable, complete in all respect with all required m
etc.

Supply, Installation and Commissioning of Main piping and valves with 150 mm dia Size 24 mtr. Co
wiring, earthing, Tools sets, Chain Pulley block and gauges complete in all respect with all required ma
(Sluice Valve Confirming to IS:14846-2000 & Reflex Valve Confirming to IS:5312
Additional Column Pipe 3 mtr long

Internal Electrification of pump house.

NEW PUMPING PLANT (4 SET) OF TUBEWELLS FEEDING TO CWR (Zone-5)/OHT connected Rebo

Supply, Installation and Commissioning of 2000 Lpm 33 mt head (25 HP) Pumping Plant for OHT Co
including SCADA comptiable starter, Control Panal, Cable, complete in all respect with all required m
etc.

Supply, Installation and Commissioning of Main piping and valves with 150 mm dia Size 24 mtr. Co
wiring, earthing, Tools sets, Chain Pulley block and gauges complete in all respect with all required ma
(Sluice Valve Confirming to IS:14846-2000 & Reflex Valve Confirming to IS:5312

Additional Column Pipe 3 mtr long


Internal Electrification of pump house.

AUTOMATIC SERVO VOLTAGE STABILIZER OF 11 NEW & 2 REBORE TUBEWELLS,FEEDING TO


ZONE-4) / CWR CONNECTED PUMPS / OHT CONNECTED NEW TUBEWELLS

Supply, Installation and Commissioning of automatic servo voltage Stabilizer-75 KVA(Input Voltage
Output Voltage 415V± 1% As per IS 9815-1994

AUTOMATIC SERVO VOLTAGE STABILIZER OF 2 Nos NEW TUBEWELLS,FEEDING TO OHT ( Z

Supply, Installation and Commissioning of automatic servo voltage Stabilizer-50 KVA(Input Voltage
Output Voltage 415V± 1% As per IS 9815-1994

AUTOMATIC SERVO VOLTAGE STABILIZER OF 4 NEW TUBEWELLS,FEEDING TO CWR ( ZONE 5


Supply, Installation and Commissioning of automatic servo voltage Stabilizer-40 KVA(Input Voltage
Output Voltage 415V± 1% As per IS 9815-1994

AUTOMATIC CHLORINATION SYSTEM

SITC of Automatic Chlorination System compatible to SCADA system for tubwells , directly feeding to O

SITC of Automatic Chlorination System compatible to SCADA system for CWR

LAYING OF RISING MAIN & CABLE, CONSTRUCTION OF PILLARS FOR REBORE TUBEWELLS

Supply, Construction of Super Structure bricks pillars for T/w with heavy duty M.S. Girder on top with
Charges etc all Complete.
Housing Chamber of T/w of Standerd size with cover

Supply and Laying of Power Cable of 16 sq. mm. (approx 200 mtr) from New T/w to existing pump h
and labour including PVC pipe .

Supply of 150/K-7 ISI Marked Ductile Iron Pressure Pipe conforming to IS 8329/2000

DI Specials of 150/K-7 ISI Marked Ductile Iron Pressure Pipe conforming to IS 8329/2000

Excavation for pipe line 0-1.5 m deep in Ordinary soil (Loam Clay, Sand)

Extra on item 61.06 for additional lead and lift


Carting from store, laying, jointing, fixing & testing of D.I. Pipe 150/K-7

Supply of C.I 150 mm dia D/F Bend 90 0 with fitting and labour charges.

Dismantling old damage plaster and making new plaster in proper ratio,flooring of pump house w
painting complete with all material T&P and labour at site

Filling of old existing t.w with clay and Cement sealing complete

SITC OF SCADA /AUTOMATION WORK OF ALL PUMPING PLANTS

CE & UL Certifeid PLC/RTU in IP 54 enclousure suitable to communicate with GSM based modem
power supply with analog and digital parameter and features as specifeid for tubewell to store and tran
backbone RTU/PLC designed with logic to transfer data at multiple stations specifeid.
GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer & gathe
site to control station all accessoreis included with signal enhancer antenna made for pumping plant in
specifeid

CE/UL certifeid Intelligent Smart Energy Meter

Motor Operated Actuater for Existing Valves 150 mm size

Main Switch Incomer Panel

Actuator Panel

CE/UL Certifeid Electromagnetic Flow Meter 150 mm size


Auto Phase reversal unit with inbuilt delay and enclosure control panel etc.

CE/UL Certifeid Hydrostatic type sub soil water level transmitter for tubewell

CE/UL certifeid Surge Protecter for control panel.

CE/UL certifeid Pressure Transmiter with local display

CE/UL Certifeid 7 hmi touch screen suitable to communication with PLC/RTU for display & control of pr

Complete cabling including power cables of all equipment.


Control panel with IP54 protection ,industrial grade for all equipments.separate for control (24V) and po

Installation, commissioning & testing trial for tubewell

SITC OF OHT AUTOMATION SYSTEM

CE/UL certifeid Radar Type level transmitter for OHT.

Actuator with valve of 350 mm dia size for OHT

Actuator with valve of 500 mm dia size for OHT


Actuator with valve of 450 mm dia size for OHT

CE/UL certifeid Electromagnetic Flowmeters for OHT.size 350 mm

CE/UL certifeid Electromagnetic Flowmeters for OHT.size 500 mm

CE/UL certifeid Electromagnetic Flowmeters for OHT.size 450 mm

Installation, commissioning & testing trial of Level Transmitter

Installation, commissioning & testing trial of Flowmeters and valves


SITC OF AUTOMATION WORK OF LOCAL CONTROL STATION

CE/UL & BIS Certified industrial grade LED MONITOR with lates configuration as per specification.

Desktop/PC with i5/i7 processor for as per spec mentioned in technical bid documents.

CE/UL Certified 3 KVA UPS with batteries as per spec mentioned in technical bid documents.

Full development version of required TAGS SCADA Software with coustomization of software for
mentioned in tachnical bid documents.

CE/UL certified local conrol room PLC with redundant CPU& power supply at LCS in IP 54 enclo
mentioned in tachnical bid documents.
GSM based wireless/Broadband/Equivalent communication system for PLC capable to transfer & rec
data form remote sites to control station,All accessories include signal enhancer antenna along with ru
DLP.

CE/UL certified Firewall for network protection.

Local video screen display size 56 "

Surge protector for Ethernet communication protection.

Industrial grade Ethernet Switch.

Canon/hp Laser printer1018 or equivalent


Installation,Commissioning ,testing including required furniture,internal wiring,PVC panelling of walls
etc.

Split AC suitable for the control room 1.5 tonnes

Security Survelliance IP Camera with required hard drive to store data of atleast 15 Days

SITC WORK OF E&M EQUIPMENTS IN CLEAR WATER SUB-STATION / PUMPING PLANT


SUB-STATION
Construction of Sub-Station

11 KV floor mounting, single row type H.T. panel having 1 No. incoming and 2 Nos. outgoing 630AMP
complete with insulated bus bars, all necessary metering and safety equipments.

0.415 KV L.T. control panel for Substation


M.S. fabricated Dust & Vermin proof of cubical type control panel . For Light, fan & Spares including A
meter, frequency meter, P.F. meter capacitor, single phasing preventer, Selector switch, fuses etc. (
MCCB of 400 Amp ,5 Nos. outgoing MCCB 4 Nos of 200 Amp and 1 nos outgoing for misc use of 63 am

Oil type step down transformer suitable for out door installation and parallel operation for 160 KVA,11/
I.S.2026 and 11171 with its all accessories and mountings complete.The transformer should be pro
circuit tapchanger for +10% to –10% in steps of 2.5% each.These tapings should be controlled by an e
off circuit tap changing switch. The temperature rise of winding by measuring resistance should not ex
ambient of 45ºC maximum. The transformer should have cable box on HT/LT side for termination of
group transformer will be DYN-11

Supply and laying of 11 KV XLPE cable of 3.5 x 95 sqmm size Al. armoured cable

300 Sqm, 3.5 core Aluminium Conductor PVC insulated Sheethed armoured Cable

95 Sqm, 3.5 core Aluminium Conductor PVC insulated Sheethed armoured Cable

Cable Jointing Kit


(i) H.T. indoor type

(ii) H.T. outgoing type

(iii) L.T. indoor type

Double earthing of all sub-station equipments complete with salt, charcoal, G.I. earth electrode, C.I
watering pipe, G.I. earth strip of adequate capacity and labour.

Erection and commissioning of all sub-station equipments

Testing of all equipments of sub-station at manufacturer’s works


Construction of foundations of Transformer and panels

Protection units like sand buckets rubber mattings fire extinguisher etc

Fencing around outdoor Transformers

Charges of Electrical safety Clearance

Clearance from Director of Electrical safety. Govt of U.P.

PUMPING PLANT
Supply,installation ,testing and commissioning of Vertical Turbine water lubricated/ Submersible pump
related accessories ,etc complete. to lift 90 LPS discharge at 34 m head complete with column Pipe of
Size of 300mm and Common Header of 300 mm size.
(2W+1S)
60 HP Vertical Flange Mounted Solid Shaft/ submersible Motor, 1475 RPM , LT Type Energy E
arrangement suitable to operate on 415 volt, 3 Phase 50 HZ AC supply.

Soft Starter with RS 485 Port For 24 X7 Running Hour with GSM Facility suitable for integration with R
Controller cum Water level Indicator for 60 H.P. pumping plant.

Supply, Installation and Commissioning of automatic servo voltage Stabilizer-150 KVA(Input Voltag
Output Voltage 415V± 1% As per IS 9815-1994 for CWR.

Valves

250 mm dia C.I.D.F. Sluice Valve with Actuator

250 mm dia C.I.D.F. Reflux Valve


300 mm dia C.I.D.F. Sluice Valve with Actuator (for common header)

300mm dia C.I.D.F. Reflux Valve

PIPING
250x300x300mm C.I.D.F. Tee - 3 Nos.
300mm dia D.F. distance piece 1m long - 3 Nos.
300mm dia D.F. distance piece 1.5m long - 3 Nos.
300mm dia D.F. distance piece 3m long - 3 Nos.
Nut-Bolt & Rubber Packing - As required
Any other Item required for proper installation of above Pumps - Job

Pressure TRANSMITTER

CE/UL Certified pressure transmitter for each Pumps with necessary fittings

Level regulator/controller
300 mm Electromagnetic Flowmeter at common Header with fitting

Mono rail Traveling Trolley with Electric operated Chain Pulley Block of 3 Tonne capacity

Fire extinguisher

Rubber resistance sheet.

Painting of all equipments

Erection of Pumping plant .


Testing of pumping plants

(a)  At works

(b)  At site

Commissioning & Testing of pumping plant

LIGHT WIRING

Light wiring of pump house H.T. Room L.T. control room, Meter Room,D.G.Room
Wiring point for light with 1.5 Sqmm PVC in suitable multi core copper cable in heavy gauge rigid
concealed in wall, complete with 1/18 Copper wire earth continuity wire and piano type switch etc com
as per I.E. Rules.
Wiring point for INDOOR and OUTDOOR LED/power plug with 2.5sqmm PVC insulated multi core cab
rigid PVC conduit cancealed in wall complete with 1/18 copper wire. Earth Continuity wire with 16 Am
switch/15 Amp Piano type switches complete in all respect.

Supply and fixing of main suitable Distribution boards with MCBs for controlling the lighting system.

Supply and fixing of factory wired INDOOR LED (50watts)complete including tube etc. on wall

Supply and fixing of OUTDOOR LED(110 watts) with its all accessories.

Exhaust fans for HT/LT room, pump house,chlorine room.

Aluminium conductor PVC insulated cables of following sizes for drawing power to feeder pillar and from
campus external lighting
1x2x6 sqmm(unarmoured)
SITC WORK OF Automation Units of ZPS/ CWR

CE & UL Certified RTU/PLC with redundant CPU & Power Supply in IP 54 enclosure suitable to comm
based modem unit with CPU & power supply with analog & digital parameters & features as specified
store and transmit data on GSM Backbone. GSM/GPRS backbone. RTU/PLC designed with logic
multiple stations as per technical specification

GSM/GPRS based wireless communication 4G modem for RTUs/PLC capable to transfer data from
with all accessories included with signal enhancer antenna made for pumping plant internet charge
specification

Intelligent energy meters

Auto phase reversal Unit 250 Amp

CE/UL Certified 7'' HMI touch screen suitable to communicate with PLC/RTU for local display &
parameters
CE/UL Certified Surge Protector for control panel

Control panel with IP 54 protection, industrial grade for all equipments( Separate for control 24 V and p

Complete cabling for ZPS

Security Survelliance IP Camera

Installation,Testing and commissioning

TRIAL RUN OF ALL E&M WORKS


CHLORINE CONSUMPTION DURING 4 MONTHS TRIAL RUN
Expenditure on hypo chloride of zone-1 to zone 5 for 17 tubewells

Expenditure on hypo chloride on 2 tubewells of zone-7

Four month Expenditure on Operations for LCS

Skilled computer Operater for Operating Pumping Plant and other equipments in Scheme in LCS Roo

Chowkidar for watch & ward of LCS Room, tubewells and all E&M works

in Figures
ed Rate in Figures
ed Rate in Words
BAD
RAMME

NUMBER # TEXT # NUMBER

Quantity Units Estimated Rate in


Rs. P

4 5 6
1.00 Nos 24594228.40

1.00 Nos 28601923.00

1.00 Nos 15414210.00


1.00 Nos 21237356.00

1.00 Nos 25724603.80

1.00 Nos 13384672.35

1.00 Nos 9459990.54


1030.00 M 1836.77

6350.00 M 2413.62

2000.00 M 3409.21

30.00 M 4605.31

1.00 Nos 59973.55


8.00 Nos 81000.99

2.00 Nos 112434.21

10114.16 Cum 229.83

1030.00 M 75.67

6350.00 M 102.09
2000.00 M 131.86

30.00 M 147.74

1.00 Nos 1360.98

8.00 Nos 2255.96

2.00 Nos 2365.66


10.00 Nos 18220.00

16.00 Nos 7050.00

3598.75 Sqm 175.79

3598.75 Sqm 1078.00

1189.00 M 8506.26
2180.00 M 7178.44

1706.00 M 6019.55

699.00 M 5102.89

1206.00 M 4195.73

4014.00 M 3409.21

5542.00 M 2413.62
8155.00 M 1836.77

4976.00 M 532.25

5504.00 M 408.93

4281.00 M 324.61

77561.00 M 255.70
12.00 Nos 144265.00

2.00 Nos 116358.00

7.00 Nos 79715.00

11.00 Nos 49498.00

15.00 Nos 34813.00

14.00 Nos 21758.00


10.00 Nos 13330.00

70.00 Nos 11352.00

15.00 Nos 11352.00

15.00 Nos 9153.63

6.00 Nos 9350.00

103227.93 Cum 229.83


17710.57 Sqm 84.44

8855.29 Sqm 175.79

27451.39 Sqm 175.00

26565.86 Sqm 121.69


17710.57 Sqm 294.87

8855.29 Sqm 1078.00

27451.39 Sqm 1279.09

26565.86 Sqm 867.86

1189.00 M 341.96
2180.00 M 257.08

1706.00 M 219.33

699.00 M 181.51

1206.00 M 147.74

4014.00 M 131.86

5542.00 M 102.09
8155.00 M 75.67

4976.00 M 55.30

5504.00 M 43.00

4281.00 M 43.00

77561.00 M 39.39
12.00 Nos 3598.89

2.00 Nos 3188.46

7.00 Nos 2365.67

11.00 Nos 2255.96

15.00 Nos 1360.98

14.00 Nos 1281.48


10.00 Nos 872.14

70.00 Nos 815.02

15.00 Nos 704.23

15.00 Nos 735.31

6.00 Nos 331.03


61.00 Nos 1050.00

61.00 Nos 18220.00

12.00 Nos 9000.00

15.00 Nos 6550.00

6.00 Nos 12800.00

37.00 EACH 10000.00


49.00 EACH 2835.00

405.96 Cum 184.50

97.75 Cum 3936.25

185.98 Cum 4894.81


14.62 Cum 9618.63

259.42 Cum 5244.91

63.75 QTL 9025.00

127.50 Sqm 3063.15

408.00 Nos 85.30

1.53 Cum 8501.77


1.87 Cum 9618.63

14.62 Cum 8501.77

45.90 Cum 9333.48

78.37 QTL 9025.00

54.57 QTL 9855.01

352.41 Sqm 52.67


275.57 Sqm 931.00

3114.06 Sqm 162.30

291.04 Sqm 196.52

306.00 Sqm 539.06

156.06 Sqm 1340.10

122.40 Sqm 465.15


734.57 Sqm 170.47

1601.23 Sqm 24.12

1734.68 Sqm 25.39

68.00 Nos 568.73

62.05 QTL 1484.29

353.26 Cum 120.86


612.00 M 1229.26

17.00 Nos 20000.00

136.00 RMT 106.21

3358.00 RMT 5810.00

6.00 EACH 38250.00

11.00 EACH 11447.22


1830.00 Sqm 1150.00

525.00 RMT 946.37

918.00 Nos 3340.99

175.00 Nos 3400.00


162.00 Nos 3450.00

48.00 Nos 3500.00

83.00 Nos 3550.00

5509.00 Nos 4457.89

1048.00 Nos 4700.00


973.00 Nos 4750.00

285.00 Nos 4800.00

496.00 Nos 4900.00

6427.00 Nos 4113.94

1223.00 Nos 4700.00


1135.00 Nos 4750.00

333.00 Nos 4800.00

578.00 Nos 4900.00

3673.00 Nos 3891.81

699.00 Nos 4147.50


649.00 Nos 4300.00

190.00 Nos 4350.00

331.00 Nos 4400.00

1836.00 Nos 2999.61

349.00 Nos 3050.00


324.00 Nos 3100.00

95.00 Nos 3150.00

165.00 Nos 3200.00

1.00 RMT 132.18

1.00 RMT 257.70


28.55 Cum 184.50

13.26 Cum 9840.93

28.80 Cum 5385.23

27.45 Cum 5735.32

10.62 Sqm 311.71


1.87 Cum 8501.77

10.54 Cum 9333.48

62.62 Sqm 664.00

2550.00 KG 90.25

175.15 Sqm 170.87

127.99 Sqm 24.12


127.99 Sqm 25.39

7.85 Sqm 1340.10

4.91 Sqm 3063.15

4.05 Sqm 2382.00

330.00 KG 90.25

13.62 Cum 965.27


6.00 Nos 1800.00

8.00 Nos 332.50

18.00 M 428.00

192.00 Cum 184.50

54.00 Cum 3936.25


196.50 Cum 4894.81

10.80 Cum 9618.63

213.30 Cum 5244.91

792.00 Sqm 931.00

64.50 Qtls 9025.00

138.00 Sqm 1340.10


72.00 Cum 9333.48

12.24 Cum 8501.77

45.00 Qtls 9025.00

1788.00 Sqm 170.87

426.00 Sqm 196.52

372.00 Sqm 539.06


239.34 Sqm 168.25

177.60 Sqm 535.26

270.00 Sqm 170.47

1500.00 Sqm 24.12

714.00 Sqm 66.32

78.00 RMT 106.21


3.60 Qtls 9855.01

246.00 Sqm 465.15

6.00 Job 62700.02

6.00 Job 125400.04


19.00 Job 29117.88

19.00 Job 25233.12

19.00 Job 39988.08

950.00 m 4799.37

1900.00 m 3319.87
1140.00 Cum 4455.00

1140.00 m 2040.39

760.00 m 1719.63

1235.00 m 2013.66
950.00 m 329.67

950.00 m 222.75

950.00 m 276.21

1140.00 Hrs. 2583.90


1900.00 Hrs. 694.98

38.00 Sets. 2227.50

19.00 Job 44550.00

19.00 No. 16038.00

13.00 Sets. 195507.72


13.00 set 190309.15

52.00 nos 5613.08

13.00 Job 17271.00

2.00 Sets. 195292.64

2.00 Sets. 190099.79


8.00 nos 5606.90

2.00 Job 17252.00

8.00 Sets. 167045.11

8.00 Sets. 190309.15

32.00 nos 5613.08


8.00 Job 17271.00

28.00 nos 248702.40

2.00 nos 171000.00


4.00 nos 151984.80

15.00 nos 67500.00

1.00 nos 67500.00

2.00 Job. 98325.00


2.00 Job 15390.00

2.00 Job 47025.00

200.00 mtr 1401.35

200.00 mtr 140.13

150.00 cu mtr 230.66

150.00 cu mtr 55.87


200.00 Mtr 155.93

4.00 Nos 4446.00

2.00 Job 21375.00

2.00 Job 21375.00

19.00 Set 247500.00


19.00 Nos. 27000.00

19.00 Set 22500.00

38.00 Nos. 81000.00

19.00 Nos. 13500.00

19.00 Nos. 22500.00

19.00 Nos. 135000.00


19.00 Nos. 45000.00

19.00 Nos. 108000.00

19.00 Nos. 13500.00

19.00 Nos. 45000.00

19.00 Nos. 27000.00

19.00 Nos. 54000.00


19.00 Nos. 108000.00

19.00 Nos. 9000.00

6.00 Nos. 102000.00

2.00 Nos. 255000.00

2.00 Nos. 399500.00


2.00 Nos. 340000.00

2.00 Nos. 280500.00

2.00 Nos. 467500.00

2.00 Nos. 425000.00

6.00 Nos. 8500.00

6.00 Nos. 8500.00


1.00 Set 216000.00

1.00 No. 81000.00

1.00 No. 135000.00

1.00 No. 360000.00

1.00 Set. 495000.00


1.00 No. 36000.00

1.00 Set. 162000.00

1.00 No 63000.00

1.00 Set. 13500.00

1.00 Set. 13500.00

1.00 Set. 27000.00


1.00 Set. 90000.00

2.00 No. 37800.00

3.00 Nos. 18000.00

1.00 Set 1899810.00


1.00 set 518130.00

2.00 Nos 339433.01

150.00 M 444.73

200.00 M 1266.83

90.00 M 444.73
2.00 Nos 8635.50

2.00 No 8635.50

12.00 Nos 3454.20

12.00 Pits 34542.00

1.00 Job 43177.50

1.00 Job 43177.50


1.00 Job 69084.00

1.00 job 21588.75

1.00 Job 43177.50

1.00 Job 43177.50


3.00 Set 587214.00

3.00 Nos 120897.00

1.00 Nos 474952.50

6.00 Nos 164074.50

3.00 Nos 159756.75


1.00 Nos 185663.25

1.00 Nos 129532.50

1.00 Set 604485.00

3.00 Set 43177.50

1.00 Set 103626.00


1.00 Nos 224523.00

1.00 Set 302242.50

2.00 Nos 21588.75

3.00 Nos 7771.95

1.00 Job 43177.50


1.00 Job 86355.00

1.00 Job 43177.50

1.00 Job 12953.25

1.00 Job 43177.50

20.00 Point 863.55


10.00 Nos 1036.26

4.00 Nos 3022.43

10.00 Nos 6476.63

4.00 Nos 12089.70

4.00 Nos 5613.08

400.00 Mtr 250.43


1.00 Nos 467500.00

1.00 Nos 25500.00

1.00 Nos 21250.00

1.00 Nos 114750.00

1.00 Nos 25500.00


1.00 Nos 12750.00

1.00 Set 127500.00

3.00 Set 68000.00

4.00 Nos 17000.00

1.00 Job 17000.00


32640.00 Hrs. 20.35

3840.00 Hrs. 15.26

4.00 Months 29970.00

4.00 Months 19980.00

Select
#REF!
NUMBER #
Supply

TOTAL AMOUNT INCLUSIVE OF


ALL TAXES BUT EXCLUSIVE OF
GST

54
24594228.4 38400000

28601923 44800000

15414210 22400000
21237356 32000000

25724603.8 40000000

13384672.35 17600000

9459990.54 16000000

0
1891873.1 2348.00

15326487 3094.00

6818420 3947.00

138159.3 4729.00

59973.55
648007.92

224868.42

2324537.3928

77940.1

648271.5
263720

4432.2

1360.98

18047.68

4731.32
182200

112800

632624.2625 175.79

3879452.5 1078

10113943.14 10443.00
15648999.2 7884.00

10269352.3 6711.00

3566920.11 5714.00

5060050.38 4729.00

13684568.94 3947.00

13376282.04 3094.00
14978859.35 2348.00

2648476 501.11

2250750.72 382.14

1389655.41 305.08

19832347.7 238.74

0
1731180 60546.00

232716 50129.00

558005 27944.00

544478 22269.00

522195 15527.00

304612 8717.00
133300 7198.00

794640 5826.00

170280 6117.00

137304.45 734.00

56100 8306.00

23724875.1519 250
0

1495480.5308 84.44

1556671.4291 175.79

4803993.25 175.00

3232799.5034 121.69

0
5222315.7759 304

9546002.62 1129

35112798.4351 1672

23055447.2596 1050

406590.44
560434.4

374176.98

126875.49

178174.44

529286.04

565782.78
617088.85

275172.8

236672

184083

3055127.79

0
43186.68

6376.92

16559.69

24815.56

20414.7

17940.72
8721.4

57051.4

10563.45

11029.65

1986.18

0
64050

1111420

108000

98250

76800

370000
138915

74899.62 220

384768.4375 4200

910336.7638 6000
140624.3706 8000

1360634.5522 6300

575343.75 12500

390551.625 2500

34802.4 85.30

13007.7081 8668
17986.8381 17248

124295.8774 17248

428406.732 13992

707289.25 8000

537787.8957 12500

18561.4347 75
256555.67 950

505411.938 220

57195.1808 280

164952.36 650

209136.006

56934.36
125222.1479 150

38621.6676 60

44043.5252 280

38673.64 550

92100.1945 12500

42695.0036 350
752307.12 1229

340000

14444.56 150

19509980 2800

229500 62500

125919.42 3200
2104500 1150

496844.25 3200

3067028.82

595000
558900

168000

294650

24558516.01

4925600
4621750

1368000

2430400

26440292.38

5748100
5391250

1598400

2832200

14294618.13

2899102.5
2790700

826500

1456400

5507283.96

1064450
1004400

299250

528000

132.18

257.7

0
5267.475 220

130490.7318 8500

155094.624 6300

157434.534 6600

3310.3602 800

0
15898.3099 8668

98374.8792 9000

41579.68 450

230137.5 90000

29927.8805 280

3087.1188 60
3249.6661 280

10519.785

15040.0665 3200

9647.1 3200

29782.5 125

13146.9774 1500
10800

2660

7704

35424

212557.5
961830.165

103881.204

1118739.303

737352

582112.5

184933.8
672010.56

104061.6648

406125

305515.56

83717.52

200530.32
40268.955

95062.176

46026.9

36180

47352.48

8284.38
35478.036

114426.9

376200.12

752400.24

0
553239.72

479429.28

759773.52

4559401.5

6307753
0

5078700

2326044.6

1306918.8

2486870.1
0

313186.5

211612.5

262399.5

2945646
1320462

84645

846450

304722

2541600.36
2474018.95

291880.16

224523

390585.28

380199.58
44855.2

34504

1336360.88

1522473.2

179618.56
138168

6963667.2

342000

0
607939.2

1012500

67500

196650
30780

94050

280270

28026

34599

8380.5
31186

17784

42750

42750

4702500
513000

427500

3078000

256500

427500

2565000
855000

2052000

256500

855000

513000

1026000
2052000

171000

612000

510000

799000
680000

561000

935000

850000

51000

51000
0

216000

81000

135000

360000

495000
36000

162000

63000

13500

13500

27000
90000

75600

54000

1899810

0
518130

678866.02

66709.5

253366

40025.7

0
17271

17271

41450.4

414504

43177.5

43177.5
69084

21588.75

43177.5

43177.5

0
1761642

362691

474952.5

984447

479270.25
185663.25

129532.5

604485

129532.5

103626
224523

302242.5

43177.5

23315.85

43177.5

0
86355

43177.5

12953.25

43177.5

17271
10362.6

12089.72

64766.3

48358.8

22452.32

100172
0

467500

25500

21250

114750

25500
12750

127500

204000

68000

17000

0
664224

58598.4

119880 29970.00

79920 19980

649811524.02
0.00
EF!
21.12
8000

Vous aimerez peut-être aussi