Académique Documents
Professionnel Documents
Culture Documents
1/65
Table des matières
I. Introduction et Motivation .....................................................................................................6
II. DONNEES ET HYPOTHESES DE CALCUL ...................................................................................6
1. MATERIAUX ................................................................................................................................ 6
2. HYPOTHESE DE VERIFICATION ................................................................................................... 6
a. Pour la structure..................................................................................................................... 6
b. Pour l’ancrage aux pieds des poteaux.................................................................................... 7
3. NORMES, REGLEMENTATION ET DOCUMENTS DE REFERENCE ................................................. 7
4. OUTILS ........................................................................................................................................ 7
III. PRESENTATION DE LA STRUCTURE .........................................................................................8
1. ANALYSE DE L’ARCHITECTURE ET DE LA CONCEPTION DE LA STRUCTURE ................................ 8
2. ANALYSE GLOBALE DE LA STRUCTURE ....................................................................................... 9
a. Stabilisation Longitudinale Et Transversale ........................................................................... 9
b. DEFAUTS GEOMETRIQUES LINEAIRES ET ANGULAIRES ....................................................... 10
c. STABILISATION PAR HYPSRTATSME DE LA STRUCTURE ....................................................... 11
IV. MODELES DE CHARGES CONSIDERES ....................................................................................12
1. CHARGE D’EXPLOITATION – CHARGEMENT VERTICAL (Q1) .................................................... 13
a. CHARGEMENT ACTUEL ......................................................................................................... 13
b. CHARGEMENT DE DIMENSIONNEMENT .............................................................................. 13
c. Charge horizontale due au frottement galets-rail ............................................................... 14
d. MAJORATION DYNAMIQUE .................................................................................................. 14
2. ETATS LIMITES CONSIDERES ET COMBINAISONS ASSOCIEES .................................................. 14
V. RESULTATS DES CALCULS ET ANALYSE CORRESPONDANTE ..................................................15
1. VISUALISATION DE LA STRUCTURE .......................................................................................... 15
2. ETAT DE CHARGE ACTUEL ........................................................................................................ 16
3. VERIFICATION AU NOUVEL ETAT DE CHARGE .......................................................................... 17
VI. RIGIDIFICATION DES POTEAU 1 ET 31 ...................................................................................21
1. Poteau 1 ................................................................................................................................... 21
2. Poteau 31 ................................................................................................................................. 22
VII. VERIFICATION DES PIEDS DE POTEAU ...................................................................................23
1. VERIFICATION AU CISAILLEMENT ............................................................................................. 24
a. Formulation des efforts par boulon ..................................................................................... 24
b. Vérification du cisaillement par boulon ............................................................................... 25
c. Résultats des calculs ............................................................................................................. 26
2/65
2. VERIFICATION DE LA COMPRESSION LOCALISEE DE LA PLATINE ............................................. 26
a. Formulation de la pression localisée .................................................................................... 26
b. Résultats des calculs ............................................................................................................. 27
3/65
Liste des figures
Fig. 1 : Visualisation de la stabilisation de la structure par portiques transversaux et longitudinaux
sans système de contreventement additionnels ..............................................................................10
Fig. 2 : Léger défaut d’orthogonalité entre les filières internes de la file 1 et de la file 2 ................11
Fig. 3 : Visualisation du pied de poteau réel .....................................................................................12
Fig. 4 : Dimensions de la platine et des trous de boulons associés ..................................................12
Fig. 5 : Visualisation de la structure et du chargement à la combinaison 4......................................15
Fig. 6 : Visualisation de la structure et du chargement Q1 et Q2 (fig. 6-b).......................................16
Fig. 7 : Résultats à l’ELU_ANCIEN (chargement actuel) ...................................................................17
Fig. 8 : Résultats à l’ELS_ANCIEN (chargement actuel)....................................................................17
Fig. 9 : Résultats de calcul à l’ELU_NOUVELLE ..................................................................................18
Fig. 9 : Résultats de calcul à l’ELS_NOUVELLE ...................................................................................18
Fig. 10 : Note de calcul simplifiée des poteaux HEA 160 et des 3 poteau en tube RECT_160x160 à
l’ELS_NOUVELLE ................................................................................................................................19
Fig. 11 : Calcul à l’ELS_NOUVELLE du poteau 1 .................................................................................20
Fig. 11 : Calcul à l’ELS_NOUVELLE du poteau 31 ...............................................................................20
Fig. 12 : Positionnement des poteaux 1 et 31 ...................................................................................21
Fig. 13 : Renforcement du poteau 31 par ajout de bras de force .....................................................22
Fig. 14 : Dessin de définition du bras de force en IPE 160-renfort du poteau 31 .............................23
Fig. 15 : Transmissions de charge ......................................................................................................24
Fig. 16 : Note de calcul des boulons de scellement les plus sollicités (poteau 27, cas de charge 4-voir
tab. 4) 26
Fig. 17 : Note de vérification de la pression localisée sous rondelle d’appuis ..................................27
4/65
Liste des Tableaux
Tab. 1 : Propriétés mécanique de l’acier S 235 JR...............................................................................6
Tab. 2 : Réglementation et documents techniques utilisés dans la note de calcul ............................7
Tab. 3 : Outils informatique utilisés ....................................................................................................7
Tab. 4 : Eléments de construction .......................................................................................................8
Tab. 5 : Combinaisons de charge étudiées ........................................................................................15
5/65
NOTE DE VERIFICATION DE LA STRUCTURE PORTEUSE DU
CONVOYEUR AERIEN REF. XXXXX
Entreprise XXX
I. Introduction et Motivation
Ce rapport présente l’expertise de l’état mécanique global de la structure porteuse en portique
du convoyeur aérien des caisses à l’entrée de la zone montage de l’usine de XXX. L’objectif
est alors d’estimer la capacité porteuse de la structure dans le but de supporter une
augmentation de la charge, principalement liée au changement de balancelle. La vérification
tiendra compte aussi des ancrages aux pieds de poteaux contre des types de défaillance
spécifiques qui seront détaillées dans la présente note de calcul.
1. MATERIAUX
Les boulons utilisés pour la fixation des pieds de poteaux sont de qualité 5.6.
2. HYPOTHESE DE VERIFICATION
a. Pour la structure
6/65
Il n’y a pas lieu d’estimer la pré-charge des boulons aux nœuds des profilés à ce niveau.
La vérification étant effectuée dans le domaine élastique linéaire, aucune classification des
sections transversales n’est nécessaire.
Les phénomènes d’instabilité par flambement et par déversement vérifiés dans cette note sont
considérés aussi en élasticité.
La contrainte équivalente d’usage dans le cas des matériaux ductile est la contrainte
équivalente de VON MISES.
4. OUTILS
L’outil-informatique utilisé dans cette note de calcul correspond aux logiciels listés au tableau
3 suivant :
7/65
Robot Structural Analysis Calcul et vérification de la structure selon les normes en vigueur
Analyse global de la structure et locale par barres
Analyse des coefficients de sécurité (ratios d dimensionnement)
Exploitation de la descente de charge et exportation vers MS Excel
pour la justification des boulons
MS Excel Justification des boulons des pieds de poteaux
8/65
4 Traverse longitudinale IPE 240 -- 101,00 La Qté n’est pas fournie car les barres
(Filière) ne sont pas régulières. Voir légende des
figures A.1 et A.2 de l’annexe 1.
9/65
Aucun autre système de stabilisation par contreventement n’est adopté à cause des contraintes
opérationnelles d’accès des opérateurs.
La légende de la figure 1 permet de visualiser les barres en couleur pour plus de détail.
10/65
Léger défaut
d’orthogonalité
Nous en concluons que la structure ne présentera pas d’hyper-statisme additionnel causées par
des déformations imposées au montage et au serrage des assemblages.
Nous pouvons dès lors considérer que le chargement appliqué correspond au poids propres des
éléments de construction, des câbles et chemins de câbles et à la charge d’exploitation.
Cependant, pour une analyse plus poussée, mais qui n’est pas justifiée à ce stade, il est possible
de prendre en compte les effets d’aplomb ou d’imperfections locales des barres verticales
comme dictée par l’EN 1993-3.
11/65
Fig. 3 : Visualisation du pied de poteau réel
12/65
o Poids estimé des câbles et chemins de câbles (G2), appliqué sur le tube carré
80x80. La valeur de cette charge linéique est estimée à 4 kg/m (0.04 kN/m) ;
- Charge d’exploitation (Q), constituée de :
o Charge verticale (Q1) : poids propre du système {rails, chariot, caisse}.
L’estimation de ce chargement est présentée au §3.1.
o Charge horizontale (Q3) : frottement causé par la traction de la charge verticale.
Estimé en moyenne entre 5% à 10% (selon (1)) de la charge.
a. CHARGEMENT ACTUEL
b. CHARGEMENT DE DIMENSIONNEMENT
13/65
𝑘𝑁
𝑄1 = 0,85
𝑚
𝑄2 = 30% 𝑄1
d. MAJORATION DYNAMIQUE
Le chargement considéré correspond à une charge roulante. La vitesse de traction étant faible
relativement à l’envergure de la structure et à la nature du matériau (acier S 235) de nature
résiliente, la charge sera considérée statique. Toutefois, une majoration tenant compte des
effets dynamiques (effets inertiels) s’impose par les prescriptions de la norme :
- Eurocode 1 partie 1-1 (EN 1991-1-1) : Actions générales — Poids volumiques, poids
propres, charges d'exploitation des bâtiments ;
- Eurocode 1 partie 5 (EN 1991-5) : Actions induites par les ponts roulants et autres
machines ;
Nous choisissons le cas extrême, le plus défavorable, en considérant une majoration
dynamique de 30%. La charge d’exploitation sera alors multipliée par le coefficient de
majoration dynamique :
𝜑 = 1.30
Dans cette expertise, nous considérons les états limites classiques, ultimes et de service, en
adoptant les combinaisons de charge suivantes :
- A l’Etat Limite Ultime (ELU) : 1,33 (𝐺1 + 𝐺2 ) + 1,50 × 1,30 (𝑄1 + 𝑄2 )
- A l’Etat Limite de Service (ELS) : 1,00 (𝐺1 + 𝐺2 ) + 1,00 × 1,30 (𝑄1 + 𝑄2 )
Le coefficient de « 1,30 » correspond au coefficient 𝜑 de la majoration dynamique.
Ces combinaisons seront adoptées pour l’état de charge actuel ainsi que pour l’état de
dimensionnement (nouveau chargement).
14/65
Le tableau 5 présente les combinaisons de charges adoptées, en désignant
Tab. 5 : Combinaisons de charge étudiées
1. VISUALISATION DE LA STRUCTURE
La figure 5 présente la structure avec l’état de charge permanente.
La figure 6-b présente un agrandissement d’une partie de la structure chargée par la charge
d’exploitation :
15/65
Les cas de charges simples étant listés au tableau 8, ainsi que les combinaisons réglementaires
associés aux ELU et ELS, nous rappelons que le calcul est effectué en deux temps :
- Vérification de l’état mécanique actuel, c'est-à-dire avec l’ancien chargement ;
- Vérification avec majoration de la masse de chaque balancelle c’est-à-dire avec le
nouveau chargement ;
Les résultats des calculs sont fournis aux paragraphes qui suivent. Ces résultats correspondent
à des notes de calcul simplifiées. La note de calcul détaillée, relative au calcul par famille de
profilés est jointe au présent rapport à l’annexe 3.
a) b)
Nous appliquons ici l’état actuel de charge. Les combinions de charge correspondantes les
combinaisons 4 et 5 du listés au tableau 5.
Etat Limite Ultime (Combinaison 4)
Toutes les familles des éléments de construction sont vérifiées à cet état limite
Les éléments les plus sollicités sont les traverses IPE 160, IPE 140, IPE 120 ainsi que les
poutres de ceinture en IPE 240.
16/65
Fig. 7 : Résultats à l’ELU_ANCIEN (chargement actuel)
Le détail des ratios suivants tous les axes et conformément aux déplacements suivants toutes
les directions est disponible à la note de calcul complète de l’annexe 3.
3. VERIFICATION AU NOUVEL ETAT DE CHARGE
Ce paragraphe permet de justifier la structure avec le nouvel état de charge définit par les deux
combinaisons 6 et 7 du tableau 5.
17/65
Etat Limite Ultime (Combinaison 6)
Les résultats de ce calcul sont conformes au premier cas de charge. Les éléments les plus
sollicités sont toujours les traverses IPE 160, IPE 140, IPE 120 ainsi que les poutres de ceinture
en IPE 240, avec des ratios de dimensionnement allant de 0,62 à 0,72.
La structure est alors optimale pour cet usage.
Les éléments de construction sont tous vérifiés l’Etat Limite de Service correspondant à la
majoration de la charge des balancelles de 800 kg à 1100 kg. La figure 10 présente la note de
calcul simplifiée à cette combinaison de charge.
18/65
Même si les éléments sont vérifiés, nous remarquons que le ratio de dimensionnent pour l’Etat
Limite de Service de la famille des poteaux HEA 160 est très grand. Il est de l’ordre de 0,96.
Cette famille est donc à vérifier en entier. Pour les autres familles d’éléments, les ratios ne
dépassent pas les 62% (0,62).
Vérifions la famille des poteaux HEA 160 un à un.
La note de calcul simplifiée présentée à la figure 10 ci-dessous présente les ratios de tous les
poteaux.
Fig. 10 : Note de calcul simplifiée des poteaux HEA 160 et des 3 poteaux
en tube RECT_160x160 à l’ELS_NOUVELLE
Nous remarquons que les poteaux les plus sollicités sont les poteaux N° 1 et 31.
19/65
Fig. 11 : Calcul à l’ELS_NOUVELLE du poteau 1
Pour le poteau 1 : Nous remarquons que, dans le sens ux, le déplacement de calcul est de 23mm
tant disque le déplacement limite correspond à L/250 (L : hauteur du poteau) et est égal à 24
mm. L’ELS est donc presque saturé. Il faut nécessairement procéder à la rigidification de ce
poteau.
Pour le poteau 31 : Nous remarquons que, dans le sens ux, le déplacement de calcul est de
21mm tant disque le déplacement limite correspond à L/250 (L : hauteur du poteau) et est égal
20/65
à 24 mm. L’ELS est donc presque saturé. Il faut nécessairement procéder à la rigidification de
ce poteau.
a)
1. Poteau 1
Pour le poteau 1, nous avons procédé à 2 changements qui donnent des résultats similaires :
21/65
2. Poteau 31
Pour le poteau 31, nous avons ajouté 2 bras de forces : qui ont permis de diminuer le ratio de
0,90 à 0,74. La figure 13 ci-dessous présente le positionnement de ces bras de force.
IPE 300
IPE 160
HEA 160
La figure présente aussi les dimensions du renfort à fabriquer par un IPE 160.
Pour des raisons de symétrie, le poteau du même portique devrait aussi être renforcé par le
même bras de force.
22/65
Fig. 14 : Dessin de définition du bras de force en IPE 160-renfort du poteau
31
23/65
1. VERIFICATION AU CISAILLEMENT
4 3
1 2
24/65
𝐹𝑥 𝑀𝑌 𝑀𝑍
𝑇1 = − + (1)
4 2𝑏 2𝑎
𝐹𝑥 𝑀𝑌 𝑀𝑍
𝑇2 = − − (2)
4 2𝑏 2𝑎
𝐹𝑥 𝑀𝑌 𝑀𝑍
𝑇3 = + − (3)
4 2𝑏 2𝑎
𝐹𝑥 𝑀𝑌 𝑀𝑍
{ 𝑇4 = + + (4)
4 2𝑏 2𝑎
𝑉𝑌 𝑀𝑋 𝑏
𝑉𝑌1 = + (5)
4 2(𝑎2 + 𝑏 2 )
𝑉𝑌 𝑀𝑋 𝑎
𝑉𝑌2 = + (6)
4 2(𝑎2 + 𝑏 2 )
(𝑆𝑦𝑠𝑡è𝑚𝑒 𝐼) 𝑉𝑌 𝑀𝑋 𝑏
𝑉𝑌3 = − (7)
4 2(𝑎2 + 𝑏 2 )
𝑉𝑌 𝑀𝑋 𝑎
𝑉𝑌4 = − (8)
{ 4 2(𝑎2 + 𝑏 2 )
𝑉𝑍 𝑀𝑋 𝑎
𝑉𝑍1 = − (9)
4 2(𝑎2 + 𝑏 2 )
𝑉𝑍 𝑀𝑋 𝑏
𝑉𝑍2 = + (10)
4 2(𝑎2 + 𝑏 2 )
𝑉𝑍 𝑀𝑋 𝑎
𝑉𝑍3 = + (11)
4 2(𝑎2 + 𝑏 2 )
𝑉𝑍 𝑀𝑋 𝑏
𝑉𝑍4 = − (12)
{{ 4 2(𝑎2 + 𝑏 2 )
Pour chaque boulon, la justification est faite suivant la condition de résistance suivante :
𝑉𝑅𝑑 𝑓𝑢𝑏 𝐴𝑠
𝑉𝐸𝑑 = √𝑉𝑌2 + 𝑉𝑍 ² ≤ = 0.6
𝛾𝑀𝑏 𝛾𝑀𝑏
Où
VEd est la charge de dimensionnement
VRd est la résistance caractéristique au cisaillement
𝑓𝑢𝑏 : Résistance ultime à la traction
𝐴𝑠 : Section apparente de la vis
𝛾𝑀𝑏 =1,25
25/65
c. Résultats des calculs
Le calcul a été effectué sous MS Excel, à partir de la descente de charges fournie par le logiciel
de dimensionnement (RSA). Les tiges utilisées sont des tiges M30.
La figure 16 ci-dessous présente la note de calcul des boulons du poteau le plus sollicité
(poteau 27).
Fig. 16 : Note de calcul des boulons de scellement les plus sollicités (poteau
27, cas de charge 4-voir tab. 4)
Nous remarquons que les boulons sont vérifiés au cisaillement avec un coefficient de sécurité avoisinant
les 56.
𝑇 𝑇
= 2 2 ) ≤ 𝜎𝑒 (13)
𝑆𝑅 𝜋(𝑑𝑒𝑥𝑡 − 𝑑𝑖𝑛𝑡
Où
T : Effort de compression sous rondelle (N) (supposé négatif contrairement à
l’arrachement où l’effort T est supposé positif)
26/65
SR : Section de la rondelle (mm²)
dext : diamètre extérieur de la rondelle (mm)
dint : diamètre intérieur de la rondelle (mm)
e : résistance élastique de la platine (235 MPa)
Dext = 56 mm ;
Dint = 31 mm ;
27/65
Annexes
28/65
Annexe 1
Fig. A.1 : Vue 3D de la structure et identification des files
File 2
File 3
File 1
File 4
29/65
Fig. A.2 : Vue de dessus de la structure File 3
File 4
File 2
Poteau 31
Poteau 1
File 1
30/65
Annexe 2
31/65
Annexe 3 :
Note de calcul détaillée
La description des Etats Limites de vérification est détaillée au tableau 4 de ce rapport.
ELU_ANCIEN (actuel)
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 1 Poteaux_HEA_160
MEMBER: 27 POINT: 1 COORDINATE: x = 0.00 L =
0.00 m
--------------------------------------------------------------------------------------------------------------------------------------
--
LOADS:
Governing Load Case: 4 ELU_ANCIEN 1*1.35+2*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
----------------------------------------------------------------------------------------------------------------------------- ---------
--
32/65
Ly = 5.90 m Lam_y = 0.67 Lz = 5.90 m Lam_z = 1.10
Lcr,y = 4.13 m Xy = 0.80 Lcr,z = 4.13 m Xz = 0.48
Lamy = 62.87 kyy = 1.01 Lamz = 103.65 kyz = 0.72
--------------------------------------------------------------------------------------------------------------------------------------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nc,Rd = 0.02 < 1.00 (6.2.4.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^1.00 = 0.13 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.00 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.02 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Global stability check of member:
Lambda,y = 62.87 < Lambda,max = 210.00 Lambda,z = 103.65 < Lambda,max = 210.00 STABLE
N,Ed/(Xy*N,Rk/gM1) + kyy*My,Ed,max/(XLT*My,Rk/gM1) + kyz*Mz,Ed,max/(Mz,Rk/gM1) = 0.39 < 1.00
(6.3.3.(4))
N,Ed/(Xz*N,Rk/gM1) + kzy*My,Ed,max/(XLT*My,Rk/gM1) + kzz*Mz,Ed,max/(Mz,Rk/gM1) = 0.33 < 1.00
(6.3.3.(4))
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 2 Traverses_IPE_300_cadre
MEMBER: 75 POINT: 1 COORDINATE: x = 0.45 L =
2.73 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 4 ELU_ANCIEN 1*1.35+2*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
----------------------------------------------------------------------------------------------------------------------------- ---------
--
33/65
----------------------------------------------------------------------------------------------------------------------------- ---------
--
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 3 Traverses_IPE_160
MEMBER: 49 POINT: 3 COORDINATE: x = 0.45 L =
3.22 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 4 ELU_ANCIEN 1*1.35+2*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
----------------------------------------------------------------------------------------------------------------------------- ---------
--
34/65
----------------------------------------------------------------------------------------------------------------------------- ---------
--
INTERNAL FORCES AND CAPACITIES:
N,Ed = 0.39 kN My,Ed = 7.68 kN*m Mz,Ed = -0.63 kN*m Vy,Ed = 0.39 kN
Nc,Rd = 472.15 kN My,Ed,max = 7.68 kN*m Mz,Ed,max = 0.63 kN*m Vy,T,Rd = 186.22 kN
Nb,Rd = 472.15 kN My,c,Rd = 29.11 kN*m Mz,c,Rd = 6.13 kN*m Vz,Ed = 3.35 kN
MN,y,Rd = 29.11 kN*m MN,z,Rd = 6.13 kN*m Vz,T,Rd = 130.99 kN
Mb,Rd = 15.83 kN*m Tt,Ed = 0.00 kN*m
Class of section = 1
----------------------------------------------------------------------------------------------------------------------------- ---------
--
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 4 Traverses_IPE_120
MEMBER: 108 POINT: 1 COORDINATE: x = 0.55 L =
3.35 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 4 ELU_ANCIEN 1*1.35+2*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
35/65
--------------------------------------------------------------------------------------------------------------------------------------
--
----------------------------------------------------------------------------------------------------------------------------- ---------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nt,Rd = 0.00 < 1.00 (6.2.3.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^1.00 = 0.26 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.00 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.03 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.01 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.01 < 1.00 (6.2.6)
Global stability check of member:
My,Ed/Mb,Rd = 0.82 < 1.00 (6.3.2.1.(1))
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 5 Traverses_IPE_200_cadre
MEMBER: 54 POINT: 3 COORDINATE: x = 0.50 L =
2.75 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 4 ELU_ANCIEN 1*1.35+2*1.95
36/65
--------------------------------------------------------------------------------------------------------------------------------------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
----------------------------------------------------------------------------------------------------------------------------- ---------
--
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
37/65
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 6 Poutre_ceinture_IPE_300
MEMBER: 78 POINT: 3 COORDINATE: x = 1.00 L =
12.87 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 4 ELU_ANCIEN 1*1.35+2*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
--------------------------------------------------------------------------------------------------------------------------------------
--
38/65
---------------------------------------------------------------------------------------------------------------- ----------------------
--
Section OK !!!
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 7 Poutre_ceinture_IPE_240
MEMBER: 70 POINT: 1 COORDINATE: x = 0.00 L =
0.00 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 4 ELU_ANCIEN 1*1.35+2*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
----------------------------------------------------------------------------------------------------------------------------- ---------
--
39/65
Vz,Ed/Vz,T,Rd = 0.05 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.01 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Global stability check of member:
My,Ed,max/Mb,Rd = 0.58 < 1.00 (6.3.2.1.(1))
N,Ed/(Xy*N,Rk/gM1) + kyy*My,Ed,max/(XLT*My,Rk/gM1) + kyz*Mz,Ed,max/(Mz,Rk/gM1) = 0.68 < 1.00
(6.3.3.(4))
N,Ed/(Xz*N,Rk/gM1) + kzy*My,Ed,max/(XLT*My,Rk/gM1) + kzz*Mz,Ed,max/(Mz,Rk/gM1) = 0.68 < 1.00
(6.3.3.(4))
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 8 Traverses_IPE_140
MEMBER: 118 POINT: 1 COORDINATE: x = 0.68 L =
4.17 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 4 ELU_ANCIEN 1*1.35+2*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
--------------------------------------------------------------------------------------------------------------------------------------
--
40/65
kyy = 1.00 kzz = 1.00
----------------------------------------------------------------------------------------------------------------------------- ---------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nc,Rd = 0.00 < 1.00 (6.2.4.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^1.00 = 0.16 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.00 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.03 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Global stability check of member:
My,Ed,max/Mb,Rd = 0.59 < 1.00 (6.3.2.1.(1))
N,Ed/(Xy*N,Rk/gM1) + kyy*My,Ed,max/(XLT*My,Rk/gM1) + kyz*Mz,Ed,max/(Mz,Rk/gM1) = 0.67 < 1.00
(6.3.3.(4))
N,Ed/(Xz*N,Rk/gM1) + kzy*My,Ed,max/(XLT*My,Rk/gM1) + kzz*Mz,Ed,max/(Mz,Rk/gM1) = 0.67 < 1.00
(6.3.3.(4))
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 9 Tube_80x80_Support_cable
MEMBER: 166 POINT: 3 COORDINATE: x = 0.51 L =
0.51 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 4 ELU_ANCIEN 1*1.35+2*1.95
--------------------------------------------------------------------------------------------------------------------------------------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
----------------------------------------------------------------------------------------------------------------------------- ---------
--
41/65
LATERAL BUCKLING PARAMETERS:
--------------------------------------------------------------------------------------------------------------------------------------
--
BUCKLING PARAMETERS:
----------------------------------------------------------------------------------------------------------------------------- ---------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nt,Rd = 0.00 < 1.00 (6.2.3.(1))
(My,Ed/MN,y,Rd)^ 1.66 + (Mz,Ed/MN,z,Rd)^1.66 = 0.02 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.03 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.01 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.18 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.18 < 1.00 (6.2.6)
--------------------------------------------------------------------------------------------------------------------------------------
--
Section OK !!!
42/65
ELS_ANCIEN (actuel)
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 1 Poteaux_HEA_160
MEMBER: 1 POINT: COORDINATE:
----------------------------------------------------------------------------------------------------------------------------- ---------
--
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 2 Traverses_IPE_300_cadre
MEMBER: 75 POINT: COORDINATE:
--------------------------------------------------------------------------------------------------------------------------------------
--
43/65
uy = 4 mm < uy max = L/200.00 = 30 mm Verified
Governing Load Case: 5 ELS_ANCIEN 1*1.00+2*1.30
uz = 2 mm < uz max = L/200.00 = 30 mm Verified
Governing Load Case: 5 ELS_ANCIEN 1*1.00+2*1.30
STEEL DESIGN
--------------------------------------------------------------------------------------------------------------------------------------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 3 Traverses_IPE_160
MEMBER: 49 POINT: COORDINATE:
----------------------------------------------------------------------------------------------------------------------------- ---------
--
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 4 Traverses_IPE_120
MEMBER: 107 POINT: COORDINATE:
----------------------------------------------------------------------------------------------------------------------------- ---------
--
44/65
tw=4 mm Iy=3177530 mm4 Iz=276682 mm4 Ix=17100 mm4
tf=6 mm Wely=52959 mm3 Welz=8646 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LIMIT DISPLACEMENTS
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 5 Traverses_IPE_200_cadre
MEMBER: 54 POINT: COORDINATE:
--------------------------------------------------------------------------------------------------------------------------------------
--
STEEL DESIGN
--------------------------------------------------------------------------------------------------------------------------------------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 6 Poutre_ceinture_IPE_300
MEMBER: 48 POINT: COORDINATE:
45/65
----------------------------------------------------------------------------------------------------------------------------- ---------
--
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 7 Poutre_ceinture_IPE_240
MEMBER: 70 POINT: COORDINATE:
--------------------------------------------------------------------------------------------------------------------------------------
--
STEEL DESIGN
--------------------------------------------------------------------------------------------------------------------------------------
--
46/65
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 8 Traverses_IPE_140
MEMBER: 118 POINT: COORDINATE:
--------------------------------------------------------------------------------------------------------------------------------------
--
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 9 Tube_80x80_Support_cable
MEMBER: 261 Beam_261 POINT: COORDINATE:
----------------------------------------------------------------------------------------------------------------------------- ---------
--
47/65
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!
48/65
ELU_NOUVELLE
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 1 Poteaux_HEA_160
MEMBER: 27 POINT: 1 COORDINATE: x = 0.00 L =
0.00 m
--------------------------------------------------------------------------------------------------------------------------------------
--
LOADS:
Governing Load Case: 6 ELU_NOUVELLE 1*1.35+3*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
--------------------------------------------------------------------------------------------------------------------------------------
--
49/65
Vz,Ed/Vz,T,Rd = 0.02 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Global stability check of member:
Lambda,y = 62.87 < Lambda,max = 210.00 Lambda,z = 103.65 < Lambda,max = 210.00 STABLE
N,Ed/(Xy*N,Rk/gM1) + kyy*My,Ed,max/(XLT*My,Rk/gM1) + kyz*Mz,Ed,max/(Mz,Rk/gM1) = 0.37 < 1.00
(6.3.3.(4))
N,Ed/(Xz*N,Rk/gM1) + kzy*My,Ed,max/(XLT*My,Rk/gM1) + kzz*Mz,Ed,max/(Mz,Rk/gM1) = 0.33 < 1.00
(6.3.3.(4))
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 2 Traverses_IPE_300_cadre
MEMBER: 75 POINT: 1 COORDINATE: x = 0.45 L =
2.73 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 6 ELU_NOUVELLE 1*1.35+3*1.95
--------------------------------------------------------------------------------------------------------------------------------------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
----------------------------------------------------------------------------------------------------------------------------- ---------
--
50/65
kyy = 1.00 kzz = 1.00
----------------------------------------------------------------------------------------------------------------------------- ---------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nc,Rd = 0.00 < 1.00 (6.2.4.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^1.00 = 0.17 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.01 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.01 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Global stability check of member:
My,Ed,max/Mb,Rd = 0.10 < 1.00 (6.3.2.1.(1))
N,Ed/(Xy*N,Rk/gM1) + kyy*My,Ed,max/(XLT*My,Rk/gM1) + kyz*Mz,Ed,max/(Mz,Rk/gM1) = 0.26 < 1.00
(6.3.3.(4))
N,Ed/(Xz*N,Rk/gM1) + kzy*My,Ed,max/(XLT*My,Rk/gM1) + kzz*Mz,Ed,max/(Mz,Rk/gM1) = 0.26 < 1.00
(6.3.3.(4))
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 3 Traverses_IPE_160
MEMBER: 49 POINT: 3 COORDINATE: x = 0.45 L =
3.22 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 6 ELU_NOUVELLE 1*1.35+3*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
----------------------------------------------------------------------------------------------------------------------------- ---------
--
51/65
LATERAL BUCKLING PARAMETERS:
z = 1.00 Mcr = 18.26 kN*m Curve,LT - b XLT = 0.54
Lcr,upp=3.58 m Lam_LT = 1.26 fi,LT = 1.24 XLT,mod = 0.54
----------------------------------------------------------------------------------------------------------------------------- ---------
--
BUCKLING PARAMETERS:
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 4 Traverses_IPE_120
MEMBER: 108 POINT: 1 COORDINATE: x = 0.55 L =
3.35 m
--------------------------------------------------------------------------------------------------------------------------------------
--
LOADS:
Governing Load Case: 6 ELU_NOUVELLE 1*1.35+3*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
--------------------------------------------------------------------------------------------------------------------------------------
--
52/65
N,Ed = -0.59 kN My,Ed = 5.78 kN*m Mz,Ed = 0.23 kN*m Vy,Ed = 0.17 kN
Nt,Rd = 310.44 kN My,pl,Rd = 14.27 kN*m Mz,pl,Rd = 3.19 kN*m Vy,T,Rd = 123.09 kN
My,c,Rd = 14.27 kN*m Mz,c,Rd = 3.19 kN*m Vz,Ed = -1.95 kN
MN,y,Rd = 14.27 kN*m MN,z,Rd = 3.19 kN*m Vz,T,Rd = 85.37 kN
Mb,Rd = 8.02 kN*m Tt,Ed = -0.00 kN*m
Class of section = 1
----------------------------------------------------------------------------------------------------------------------------- ---------
--
----------------------------------------------------------------------------------------------------------------------------- ---------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nt,Rd = 0.00 < 1.00 (6.2.3.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^1.00 = 0.24 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.00 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.02 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.01 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.01 < 1.00 (6.2.6)
Global stability check of member:
My,Ed/Mb,Rd = 0.72 < 1.00 (6.3.2.1.(1))
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 5 Traverses_IPE_200_cadre
MEMBER: 54 POINT: 3 COORDINATE: x = 0.50 L =
2.75 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 6 ELU_NOUVELLE 1*1.35+3*1.95
--------------------------------------------------------------------------------------------------------------------------------------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
----------------------------------------------------------------------------------------------------------------------------- ---------
--
53/65
tf=9 mm Wply=220657 mm3 Wplz=44614 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
INTERNAL FORCES AND CAPACITIES:
N,Ed = 1.07 kN My,Ed = 6.43 kN*m Mz,Ed = -1.37 kN*m Vy,Ed = 0.92 kN
Nc,Rd = 669.38 kN My,Ed,max = 6.43 kN*m Mz,Ed,max = 1.44 kN*m Vy,T,Rd = 265.49 kN
Nb,Rd = 669.38 kN My,c,Rd = 51.85 kN*m Mz,c,Rd = 10.48 kN*m Vz,Ed = 2.53 kN
MN,y,Rd = 51.85 kN*m MN,z,Rd = 10.48 kN*m Vz,T,Rd = 189.87 kN
Mb,Rd = 41.93 kN*m Tt,Ed = 0.00 kN*m
Class of section = 1
----------------------------------------------------------------------------------------------------------------------------- ---------
--
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 6 Poutre_ceinture_IPE_300
MEMBER: 48 POINT: 1 COORDINATE: x = 0.60 L =
5.84 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 6 ELU_NOUVELLE 1*1.35+3*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
54/65
--------------------------------------------------------------------------------------------------------------------------------------
--
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 7 Poutre_ceinture_IPE_240
MEMBER: 70 POINT: 1 COORDINATE: x = 0.00 L =
0.00 m
55/65
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 6 ELU_NOUVELLE 1*1.35+3*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
----------------------------------------------------------------------------------------------------------------------------- ---------
--
STEEL DESIGN
56/65
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 8 Traverses_IPE_140
MEMBER: 118 POINT: 1 COORDINATE: x = 0.68 L =
4.17 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 6 ELU_NOUVELLE 1*1.35+3*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
--------------------------------------------------------------------------------------------------------------------------------------
--
57/65
N,Ed/(Xz*N,Rk/gM1) + kzy*My,Ed,max/(XLT*My,Rk/gM1) + kzz*Mz,Ed,max/(Mz,Rk/gM1) = 0.62 < 1.00
(6.3.3.(4))
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 9 Tube_80x80_Support_cable
MEMBER: 132 POINT: 3 COORDINATE: x = 0.51 L =
0.51 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 6 ELU_NOUVELLE 1*1.35+3*1.95
--------------------------------------------------------------------------------------------------------------------------------------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
----------------------------------------------------------------------------------------------------------------------------- ---------
--
----------------------------------------------------------------------------------------------------------------------------- ---------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nc,Rd = 0.02 < 1.00 (6.2.4.(1))
(My,Ed/MN,y,Rd)^ 1.66 + (Mz,Ed/MN,z,Rd)^1.66 = 0.06 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.04 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.02 < 1.00 (6.2.6-7)
58/65
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.20 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.20 < 1.00 (6.2.6)
--------------------------------------------------------------------------------------------------------------------------------------
--
Section OK !!!
59/65
ELS_NOUVELLE
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 1 Poteaux_HEA_160
MEMBER: 1 POINT: COORDINATE:
----------------------------------------------------------------------------------------------------------------------------- ---------
--
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 2 Traverses_IPE_300_cadre
MEMBER: 75 POINT: COORDINATE:
--------------------------------------------------------------------------------------------------------------------------------------
--
60/65
uy = 5 mm < uy max = L/200.00 = 30 mm Verified
Governing Load Case: 7 ELS_NOUVELLE 1*1.00+3*1.30
uz = 2 mm < uz max = L/200.00 = 30 mm Verified
Governing Load Case: 7 ELS_NOUVELLE 1*1.00+3*1.30
STEEL DESIGN
--------------------------------------------------------------------------------------------------------------------------------------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 3 Traverses_IPE_160
MEMBER: 49 POINT: COORDINATE:
----------------------------------------------------------------------------------------------------------------------------- ---------
--
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 4 Traverses_IPE_120
MEMBER: 107 POINT: COORDINATE:
----------------------------------------------------------------------------------------------------------------------------- ---------
--
61/65
tw=4 mm Iy=3177530 mm4 Iz=276682 mm4 Ix=17100 mm4
tf=6 mm Wely=52959 mm3 Welz=8646 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LIMIT DISPLACEMENTS
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 5 Traverses_IPE_200_cadre
MEMBER: 54 POINT: COORDINATE:
--------------------------------------------------------------------------------------------------------------------------------------
--
STEEL DESIGN
--------------------------------------------------------------------------------------------------------------------------------------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 6 Poutre_ceinture_IPE_300
MEMBER: 48 POINT: COORDINATE:
62/65
----------------------------------------------------------------------------------------------------------------------------- ---------
--
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 7 Poutre_ceinture_IPE_240
MEMBER: 70 POINT: COORDINATE:
--------------------------------------------------------------------------------------------------------------------------------------
--
STEEL DESIGN
--------------------------------------------------------------------------------------------------------------------------------------
--
63/65
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 8 Traverses_IPE_140
MEMBER: 118 POINT: COORDINATE:
--------------------------------------------------------------------------------------------------------------------------------------
--
STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 9 Tube_80x80_Support_cable
MEMBER: 261 Beam_261 POINT: COORDINATE:
----------------------------------------------------------------------------------------------------------------------------- ---------
--
64/65
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!
65/65