Vous êtes sur la page 1sur 65

NOTE DE CALCUL

CHANTIER : NOTE DE VERIFICATION DU CONVOYEUR


AERIEN REF. XXXX
Version 16-07-2018 : OR

1/65
Table des matières
I. Introduction et Motivation .....................................................................................................6
II. DONNEES ET HYPOTHESES DE CALCUL ...................................................................................6
1. MATERIAUX ................................................................................................................................ 6
2. HYPOTHESE DE VERIFICATION ................................................................................................... 6
a. Pour la structure..................................................................................................................... 6
b. Pour l’ancrage aux pieds des poteaux.................................................................................... 7
3. NORMES, REGLEMENTATION ET DOCUMENTS DE REFERENCE ................................................. 7
4. OUTILS ........................................................................................................................................ 7
III. PRESENTATION DE LA STRUCTURE .........................................................................................8
1. ANALYSE DE L’ARCHITECTURE ET DE LA CONCEPTION DE LA STRUCTURE ................................ 8
2. ANALYSE GLOBALE DE LA STRUCTURE ....................................................................................... 9
a. Stabilisation Longitudinale Et Transversale ........................................................................... 9
b. DEFAUTS GEOMETRIQUES LINEAIRES ET ANGULAIRES ....................................................... 10
c. STABILISATION PAR HYPSRTATSME DE LA STRUCTURE ....................................................... 11
IV. MODELES DE CHARGES CONSIDERES ....................................................................................12
1. CHARGE D’EXPLOITATION – CHARGEMENT VERTICAL (Q1) .................................................... 13
a. CHARGEMENT ACTUEL ......................................................................................................... 13
b. CHARGEMENT DE DIMENSIONNEMENT .............................................................................. 13
c. Charge horizontale due au frottement galets-rail ............................................................... 14
d. MAJORATION DYNAMIQUE .................................................................................................. 14
2. ETATS LIMITES CONSIDERES ET COMBINAISONS ASSOCIEES .................................................. 14
V. RESULTATS DES CALCULS ET ANALYSE CORRESPONDANTE ..................................................15
1. VISUALISATION DE LA STRUCTURE .......................................................................................... 15
2. ETAT DE CHARGE ACTUEL ........................................................................................................ 16
3. VERIFICATION AU NOUVEL ETAT DE CHARGE .......................................................................... 17
VI. RIGIDIFICATION DES POTEAU 1 ET 31 ...................................................................................21
1. Poteau 1 ................................................................................................................................... 21
2. Poteau 31 ................................................................................................................................. 22
VII. VERIFICATION DES PIEDS DE POTEAU ...................................................................................23
1. VERIFICATION AU CISAILLEMENT ............................................................................................. 24
a. Formulation des efforts par boulon ..................................................................................... 24
b. Vérification du cisaillement par boulon ............................................................................... 25
c. Résultats des calculs ............................................................................................................. 26

2/65
2. VERIFICATION DE LA COMPRESSION LOCALISEE DE LA PLATINE ............................................. 26
a. Formulation de la pression localisée .................................................................................... 26
b. Résultats des calculs ............................................................................................................. 27

3/65
Liste des figures
Fig. 1 : Visualisation de la stabilisation de la structure par portiques transversaux et longitudinaux
sans système de contreventement additionnels ..............................................................................10
Fig. 2 : Léger défaut d’orthogonalité entre les filières internes de la file 1 et de la file 2 ................11
Fig. 3 : Visualisation du pied de poteau réel .....................................................................................12
Fig. 4 : Dimensions de la platine et des trous de boulons associés ..................................................12
Fig. 5 : Visualisation de la structure et du chargement à la combinaison 4......................................15
Fig. 6 : Visualisation de la structure et du chargement Q1 et Q2 (fig. 6-b).......................................16
Fig. 7 : Résultats à l’ELU_ANCIEN (chargement actuel) ...................................................................17
Fig. 8 : Résultats à l’ELS_ANCIEN (chargement actuel)....................................................................17
Fig. 9 : Résultats de calcul à l’ELU_NOUVELLE ..................................................................................18
Fig. 9 : Résultats de calcul à l’ELS_NOUVELLE ...................................................................................18
Fig. 10 : Note de calcul simplifiée des poteaux HEA 160 et des 3 poteau en tube RECT_160x160 à
l’ELS_NOUVELLE ................................................................................................................................19
Fig. 11 : Calcul à l’ELS_NOUVELLE du poteau 1 .................................................................................20
Fig. 11 : Calcul à l’ELS_NOUVELLE du poteau 31 ...............................................................................20
Fig. 12 : Positionnement des poteaux 1 et 31 ...................................................................................21
Fig. 13 : Renforcement du poteau 31 par ajout de bras de force .....................................................22
Fig. 14 : Dessin de définition du bras de force en IPE 160-renfort du poteau 31 .............................23
Fig. 15 : Transmissions de charge ......................................................................................................24
Fig. 16 : Note de calcul des boulons de scellement les plus sollicités (poteau 27, cas de charge 4-voir
tab. 4) 26
Fig. 17 : Note de vérification de la pression localisée sous rondelle d’appuis ..................................27

4/65
Liste des Tableaux
Tab. 1 : Propriétés mécanique de l’acier S 235 JR...............................................................................6
Tab. 2 : Réglementation et documents techniques utilisés dans la note de calcul ............................7
Tab. 3 : Outils informatique utilisés ....................................................................................................7
Tab. 4 : Eléments de construction .......................................................................................................8
Tab. 5 : Combinaisons de charge étudiées ........................................................................................15

5/65
NOTE DE VERIFICATION DE LA STRUCTURE PORTEUSE DU
CONVOYEUR AERIEN REF. XXXXX
Entreprise XXX

I. Introduction et Motivation
Ce rapport présente l’expertise de l’état mécanique global de la structure porteuse en portique
du convoyeur aérien des caisses à l’entrée de la zone montage de l’usine de XXX. L’objectif
est alors d’estimer la capacité porteuse de la structure dans le but de supporter une
augmentation de la charge, principalement liée au changement de balancelle. La vérification
tiendra compte aussi des ancrages aux pieds de poteaux contre des types de défaillance
spécifiques qui seront détaillées dans la présente note de calcul.

II. DONNEES ET HYPOTHESES DE CALCUL

1. MATERIAUX

Le matériau qui constitue la structure étudiée est le S 235 JR (EN 10025-2).

Les boulons utilisés pour la fixation des pieds de poteaux sont de qualité 5.6.

Les caractéristiques mécaniques de ces matériaux sont présentées au tableau 1.

Tab. 1 : Propriétés mécanique de l’acier S 235 JR

Matériau Re ou Rp 0.2% Rm (MPa) Module de Young E Coefficient de


(MPa) (MPa) Poisson ν
S 235 235 360 210000 0.3

Qualité 5.6 300 500 210000 0.3

2. HYPOTHESE DE VERIFICATION

a. Pour la structure

La vérification est faite dans le domaine élastique linéaire.

Aucune pré-charge ou contrainte résiduelle de soudage, de déformation plastique (écrouissage)


ou d’un autre procédé de découpe ou de mise en forme n’est considéré puisque le S 235 JR est
un matériau qui n’est pas trempable par soudage ou découpage au feu (%C < 0.02).

6/65
Il n’y a pas lieu d’estimer la pré-charge des boulons aux nœuds des profilés à ce niveau.

La vérification étant effectuée dans le domaine élastique linéaire, aucune classification des
sections transversales n’est nécessaire.

Les phénomènes d’instabilité par flambement et par déversement vérifiés dans cette note sont
considérés aussi en élasticité.

b. Pour l’ancrage aux pieds des poteaux


La contrainte utilisée pour la justification des boulons est la contrainte ultime, comme cela est
dicté par la norme EN 1993-1-8.

Les boulons seront dimensionnés sous efforts composés en cisaillement et traction.

La contrainte équivalente d’usage dans le cas des matériaux ductile est la contrainte
équivalente de VON MISES.

Aucune pré-charge de boulonnage n’est considérée.

3. NORMES, REGLEMENTATION ET DOCUMENTS DE REFERENCE

Les normes utilisées dans ce rapport sont listées au tableau 2 suivant :

Tab. 2 : Réglementation et documents techniques utilisés dans la note de calcul

Normes Usage dans la note


Eurocode 3, partie 1-1 : pour la vérification des
sections transversales
EN 1993-1-1 (2005)
Estimation du coefficient de majoration
dynamique
EN 1993-1-8 (2005 and 2009) Justification des boulons

4. OUTILS

L’outil-informatique utilisé dans cette note de calcul correspond aux logiciels listés au tableau
3 suivant :

Tab. 3 : Outils informatique utilisés


Logiciel Usage

AutoCAD  Estimation des distances fonctionnelles utiles à partir du modèle


numérique correspondant au scan
 Préparation des données pour intégration dans Robot Structural
Analysis

7/65
Robot Structural Analysis  Calcul et vérification de la structure selon les normes en vigueur
 Analyse global de la structure et locale par barres
 Analyse des coefficients de sécurité (ratios d dimensionnement)
 Exploitation de la descente de charge et exportation vers MS Excel
pour la justification des boulons
MS Excel  Justification des boulons des pieds de poteaux

III. PRESENTATION DE LA STRUCTURE

1. ANALYSE DE L’ARCHITECTURE ET DE LA CONCEPTION DE LA


STRUCTURE
La structure considérée est présentée sous forme de cadres principaux et de filières
longitudinales (poutres suivant la longueur) permettant de lier ces cadres.
Pour des raisons de répartition symétrique du chargement, les cadres devraient être semblables,
les filières longitudinales aussi. Toutefois, nous remarquons que ce n’est pas le cas. Certaines
poutres transversales de cadres sont faites de profilés IPE 300 d’autres de profilés IPE 160.
Pour les filières longitudinales, certaines sont faites de profilés IPE 300, d’autres d’IPE 240.
Pour les poteaux, la majorité est faite en HEA 160 et il existe aussi 4 poteau en tube carré
160x160.
L’effet de cette disposition n’est estimable qu’après calcul.
L’annexe 1 présente la vue tridimensionnelle de la structure à la figure A.1 et la vue de dessus
de celle-ci à la figure A.2. Nous avons décomposé la structure en 4 files comme cela est
présenté aux figures A.1 et A.2 de l’annexe 1. La décomposition par files permet alors
d’identifier quelques composantes asymétriques de la structure conformément aux
observations listées au tableau 4.
Le tableau 4 résume les types de profilés utilisés dans cette structure.
Tab. 4 : Eléments de construction

Référence Fonction /Désignation Profilé Quantité Longueur totale Obs. (appartenance)


(annexe 1) (m)

1 Poteau HEA 160 30 177,00 2 par cadre-portique

2 Poteau Tube Rect. 4 23,60 Appartenant à la File 2 (voir la sur


160x160 légende la figure A.1)

3 Poutre (traverse) de IPE 300 8 31,04 1 par cadre-portique


cadre
4 Traverse longitudinal IPE 300 -- 197,31 La Qté n’est pas fournie car les barres
(filière) ne sont pas régulières. Voir légende des
figures A.1 et A.2 de l’annexe 1.

8/65
4 Traverse longitudinale IPE 240 -- 101,00 La Qté n’est pas fournie car les barres
(Filière) ne sont pas régulières. Voir légende des
figures A.1 et A.2 de l’annexe 1.

5 Poutre (traverse) de IPE 200 2 11,00 Supporter la charge et la transférer aux


cadre poutres IPE 300 des portiques

6 Poutre (traverse) de IPE 160 -- 130,00 La poutre de transport supporte le rail


cadre + Poutre de supérieur. La longueur de ces poutres
transport dépendent de leur positions

7 Poutre de transport IPE 140 -- 31,30 Longueur dépendant de la position

8 Poutre de transport IPE 120 -- 46,45 Longueur dépendant de la position

9 Tube rectangulaire 80x80x3.5 -- 88,70 Pour chemins de câbles


Longueur dépendant de la position

2. ANALYSE GLOBALE DE LA STRUCTURE

a. Stabilisation Longitudinale Et Transversale

Cette analyse permettra de mettre l’accent sur la stabilisation longitudinale et transversale de


la structure.
Vu l’usage de la structure, l’encombrement des postes de travail et les passages latéraux
fonctionnels, nous voyons que la stabilisation est assurée par :
- Stabilité transversale :
o Assurée par les cadres portiques principaux, avec poteaux HEA 160 et traverse
de cadre en IPE pour les files1, 4 et pour une demi-file 3 (figure 1 ci-dessous
et fig. A.1 de l’annexe 1) ;
o Assurée par les cadres portiques principaux, avec poteaux HEA 160 et traverse
de cadre en IPE 160 pour la file 2 (figure 1 ci-dessous et fig. A.1 de l’annexe
1) ;
o Assurée par les cadres portiques principaux, avec poteaux HEA 160 et traverse
de cadre en IPE 200 pour une demi-file 3 (figure 1 ci-dessous et fig. A.1 de
l’annexe 1) ;
- Stabilité longitudinale : assurée par des portiques longitudinaux. En effet, ces portiques
de grande taille sont composés par les poteaux en HEA 160 et par les filières en IPE
300, (file 1, 3 et 4), ainsi que les filières en IPE 240 pour la file 2 et la file 3 (figure 1
ci-dessous et fig. A.1 de l’annexe 1).

9/65
Aucun autre système de stabilisation par contreventement n’est adopté à cause des contraintes
opérationnelles d’accès des opérateurs.
La légende de la figure 1 permet de visualiser les barres en couleur pour plus de détail.

Cadres long. dans le plan YZ


Stabilité transversale contre les efforts
horizontaux suivant l’axe Y
Cadres de portiques (principaux) dans le plan XZ
Stabilité transversale contre les efforts horizontaux
suivant l’axe X

Fig. 1 : Visualisation de la stabilisation de la structure par portiques


transversaux et longitudinaux sans système de contreventement
additionnels

b. DEFAUTS GEOMETRIQUES LINEAIRES ET ANGULAIRES

Le Scan de la structure a permis la mise en évidence de légers décalages au niveau de


l’exécution. Ces décalages peuvent être mesurés directement sur le document au format
AutoCAD joint avec le présent rapport (sous format numérique).
Nous avons conclu que les principaux décalages linéaires qui existent correspondent aux
distances entre les cadres. Ces distances présentent une variabilité maximale d’au plus 1%.
Pour les défauts angulaires, ils s’avèrent très rares. Néanmoins, nous avons décelé de légers
décalages de l’ordre de 1° relatif à l’orthogonalité des filières de la file 1 avec les filières de la
file 2 comme présenté à la figure 2. Ce défaut n’est pas nécessairement dû à l’exécution de la
structure, il peut être causé par le service, mais il n’affecte en rien le fonctionnement souhaité.

10/65
Léger défaut
d’orthogonalité

Fig. 2 : Léger défaut d’orthogonalité entre les filières internes de la file 1 et


de la file 2

Nous en concluons que la structure ne présentera pas d’hyper-statisme additionnel causées par
des déformations imposées au montage et au serrage des assemblages.
Nous pouvons dès lors considérer que le chargement appliqué correspond au poids propres des
éléments de construction, des câbles et chemins de câbles et à la charge d’exploitation.
Cependant, pour une analyse plus poussée, mais qui n’est pas justifiée à ce stade, il est possible
de prendre en compte les effets d’aplomb ou d’imperfections locales des barres verticales
comme dictée par l’EN 1993-3.

c. STABILISATION PAR HYPSRTATSME DE LA STRUCTURE


Vu les conditions d’appui aux pieds de poteaux relatives à l’encastrement assuré par 4 boulons
comme illustré aux figure 3 et 4, et vu les différentes poutres transversales et longitudinales
assurant le lien entre les différents cadres et filières la structures étudiée est fortement
hypostatique. C’est une condition favorable pour la stabilité de la structure vu son utilisation
dans le convoyage des véhicules.

11/65
Fig. 3 : Visualisation du pied de poteau réel

Fig. 4 : Dimensions de la platine et des trous de boulons associés

IV. MODELS DE CHARGES CONSIDERES


Le chargement considéré correspond au cas de charges suivants :
- Charges permanentes (G) :
o Poids propres des éléments de construction : G1 ;

12/65
o Poids estimé des câbles et chemins de câbles (G2), appliqué sur le tube carré
80x80. La valeur de cette charge linéique est estimée à 4 kg/m (0.04 kN/m) ;
- Charge d’exploitation (Q), constituée de :
o Charge verticale (Q1) : poids propre du système {rails, chariot, caisse}.
L’estimation de ce chargement est présentée au §3.1.
o Charge horizontale (Q3) : frottement causé par la traction de la charge verticale.
Estimé en moyenne entre 5% à 10% (selon (1)) de la charge.

1. CHARGE D’EXPLOITATION – CHARGEMENT VERTICAL (Q1)


Le chargement vertical d’exploitation a été estimé selon le cahier des charges dicté par
l’entreprise et défini comme suit :

a. CHARGEMENT ACTUEL

- Ancienne nacelle à vide : 800 kg ;


- Caisse vide (tôle uniquement) : 400 kg ;
-  Chargement total par balancelle égal à : 1200 kg
- Nombre de nacelles sur tout le pourtour de la structure : 8 ;
- Longueur totale du rail de 144 m ;
La charge linéique à appliquer sur le rail est de :
1200 𝑘𝑔 × 8
𝑄1 =
144 𝑚
𝑘𝑁
𝑄1 = 0.67
𝑚

b. CHARGEMENT DE DIMENSIONNEMENT

- Nouvelle nacelle à vide : 1100 kg ;


- Caisse vide (tôle uniquement) : 400 kg ;
-  Chargement total par balancelle égal à : 1500 kg
- Nombre de nacelles sur tout le pourtour de la structure : 8 ;
- Longueur totale du rail de 144 m ;
La charge linéique à appliquer sur le rail est de :
1500 𝑘𝑔 × 8
𝑄1 =
144 𝑚

(1) : Université de Lyon 1, http://dds.univ-lyon1.fr/webapp/website/website.html?id=2886239&pageId=207633, consulté le 27/06/2017

13/65
𝑘𝑁
𝑄1 = 0,85
𝑚

c. Charge horizontale due au frottement galets-rail

La charge de frottement considérée est horizontale, appliquée parallèlement au rail.


Cette charge est appliquée sur le rail en multipliant la charge verticale Q1 par 10%.
Mais afin de tenir compte des éventuels blocages, coup à coup, différence de graissage dans
certains points…, nous appliquons une charge horizontale de frottement estimée à :

𝑄2 = 30% 𝑄1

d. MAJORATION DYNAMIQUE

Le chargement considéré correspond à une charge roulante. La vitesse de traction étant faible
relativement à l’envergure de la structure et à la nature du matériau (acier S 235) de nature
résiliente, la charge sera considérée statique. Toutefois, une majoration tenant compte des
effets dynamiques (effets inertiels) s’impose par les prescriptions de la norme :
- Eurocode 1 partie 1-1 (EN 1991-1-1) : Actions générales — Poids volumiques, poids
propres, charges d'exploitation des bâtiments ;
- Eurocode 1 partie 5 (EN 1991-5) : Actions induites par les ponts roulants et autres
machines ;
Nous choisissons le cas extrême, le plus défavorable, en considérant une majoration
dynamique de 30%. La charge d’exploitation sera alors multipliée par le coefficient de
majoration dynamique :
𝜑 = 1.30

2. ETATS LIMITES CONSIDERES ET COMBINAISONS ASSOCIEES

Dans cette expertise, nous considérons les états limites classiques, ultimes et de service, en
adoptant les combinaisons de charge suivantes :
- A l’Etat Limite Ultime (ELU) : 1,33 (𝐺1 + 𝐺2 ) + 1,50 × 1,30 (𝑄1 + 𝑄2 )
- A l’Etat Limite de Service (ELS) : 1,00 (𝐺1 + 𝐺2 ) + 1,00 × 1,30 (𝑄1 + 𝑄2 )
Le coefficient de « 1,30 » correspond au coefficient 𝜑 de la majoration dynamique.
Ces combinaisons seront adoptées pour l’état de charge actuel ainsi que pour l’état de
dimensionnement (nouveau chargement).

14/65
Le tableau 5 présente les combinaisons de charges adoptées, en désignant
Tab. 5 : Combinaisons de charge étudiées

Indice Désignation Notation Combinaison Majoration


dynamique
1 PERMANENTE G : G1 + G2 SANS
2 CHARGE_ANCIENNE QA : Q1 + Q2 SANS
3 CHARGE_NOUVELLE QN : Q1+Q2 SANS
4 ELU_ANCIEN = 1,35 G + 1,50 x 1,30 QA AVEC
5 ELS_ANCIEN = 1,00 G + 1,00 x 1,30 QA AVEC
6 ELU_NOUVELLE = 1,35 G + 1,50 x 1,30 QN AVEC
7 ELS_NOUVELLE = 1,00 G + 1,00 x 1,30 QN AVEC

V. RESULTATS DES CALCULS ET ANALYSE CORRESPONDANTE


Les paragraphes suivants constituent un guide de lecture de la note de calcul détaillée à
l’annexe 3.
Le calcul est fait suivant l’EN 1993 (version 2005).

1. VISUALISATION DE LA STRUCTURE
La figure 5 présente la structure avec l’état de charge permanente.

Fig. 5 : Visualisation de la structure et du chargement à la combinaison 4

La figure 6-b présente un agrandissement d’une partie de la structure chargée par la charge
d’exploitation :

- Le vecteur vertical correspond à la charge Q1 ;


- Le vecteur horizontal correspond au frottement Q2 ;

15/65
Les cas de charges simples étant listés au tableau 8, ainsi que les combinaisons réglementaires
associés aux ELU et ELS, nous rappelons que le calcul est effectué en deux temps :
- Vérification de l’état mécanique actuel, c'est-à-dire avec l’ancien chargement ;
- Vérification avec majoration de la masse de chaque balancelle c’est-à-dire avec le
nouveau chargement ;
Les résultats des calculs sont fournis aux paragraphes qui suivent. Ces résultats correspondent
à des notes de calcul simplifiées. La note de calcul détaillée, relative au calcul par famille de
profilés est jointe au présent rapport à l’annexe 3.

a) b)

Fig. 6 : Visualisation de la structure et du chargement Q1 et Q2 (fig. 6-b)

2. ETAT DE CHARGE ACTUEL

Nous appliquons ici l’état actuel de charge. Les combinions de charge correspondantes les
combinaisons 4 et 5 du listés au tableau 5.
 Etat Limite Ultime (Combinaison 4)

Toutes les familles des éléments de construction sont vérifiées à cet état limite
Les éléments les plus sollicités sont les traverses IPE 160, IPE 140, IPE 120 ainsi que les
poutres de ceinture en IPE 240.

16/65
Fig. 7 : Résultats à l’ELU_ANCIEN (chargement actuel)

 Etat Limite de Service (Combinaison 5)

La figure 8 présente le résultat simplifié du calcul à l’ELS_ANCIEN définit au tableau 5.


Nous remarquons que toutes les barres sont vérifiées à l’Etat Limite de Service. Les ratios de
dimensionnement, sont très faibles sauf pour les familles des poteaux (famille 1), des traerse
en IPE 120 (famille 4) ainsi que pour les tube de support des câbles (famille 9). En effet les
ratios de ces familles sont modérés et se situent entre 0,62 vers uz et 0,79 vers vx.

Fig. 8 : Résultats à l’ELS_ANCIEN (chargement actuel)

Le détail des ratios suivants tous les axes et conformément aux déplacements suivants toutes
les directions est disponible à la note de calcul complète de l’annexe 3.
3. VERIFICATION AU NOUVEL ETAT DE CHARGE

Ce paragraphe permet de justifier la structure avec le nouvel état de charge définit par les deux
combinaisons 6 et 7 du tableau 5.

17/65
 Etat Limite Ultime (Combinaison 6)

La figure 9 présente le résultat simplifié du calcul à l’ELU_NOUVELLE définit au tableau


5.

Fig. 9 : Résultats de calcul à l’ELU_NOUVELLE

Les résultats de ce calcul sont conformes au premier cas de charge. Les éléments les plus
sollicités sont toujours les traverses IPE 160, IPE 140, IPE 120 ainsi que les poutres de ceinture
en IPE 240, avec des ratios de dimensionnement allant de 0,62 à 0,72.
La structure est alors optimale pour cet usage.

 Etat Limite de Service (Combinaison 7)

Les éléments de construction sont tous vérifiés l’Etat Limite de Service correspondant à la
majoration de la charge des balancelles de 800 kg à 1100 kg. La figure 10 présente la note de
calcul simplifiée à cette combinaison de charge.

Fig. 9 : Résultats de calcul à l’ELS_NOUVELLE

18/65
Même si les éléments sont vérifiés, nous remarquons que le ratio de dimensionnent pour l’Etat
Limite de Service de la famille des poteaux HEA 160 est très grand. Il est de l’ordre de 0,96.

Cette famille est donc à vérifier en entier. Pour les autres familles d’éléments, les ratios ne
dépassent pas les 62% (0,62).
Vérifions la famille des poteaux HEA 160 un à un.

La note de calcul simplifiée présentée à la figure 10 ci-dessous présente les ratios de tous les
poteaux.

Fig. 10 : Note de calcul simplifiée des poteaux HEA 160 et des 3 poteaux
en tube RECT_160x160 à l’ELS_NOUVELLE

Nous remarquons que les poteaux les plus sollicités sont les poteaux N° 1 et 31.

Les figures 11 et 12 présentent respectivement le détail du calcul des déplacements nodaux


supérieurs qui conditionne le calcul des ratios.

19/65
Fig. 11 : Calcul à l’ELS_NOUVELLE du poteau 1

Fig. 11 : Calcul à l’ELS_NOUVELLE du poteau 31

Pour le poteau 1 : Nous remarquons que, dans le sens ux, le déplacement de calcul est de 23mm
tant disque le déplacement limite correspond à L/250 (L : hauteur du poteau) et est égal à 24
mm. L’ELS est donc presque saturé. Il faut nécessairement procéder à la rigidification de ce
poteau.

Pour le poteau 31 : Nous remarquons que, dans le sens ux, le déplacement de calcul est de
21mm tant disque le déplacement limite correspond à L/250 (L : hauteur du poteau) et est égal

20/65
à 24 mm. L’ELS est donc presque saturé. Il faut nécessairement procéder à la rigidification de
ce poteau.

VI. RIGIDIFICATION DES POTEAU 1 ET 31


La figure 12 ci-dessous présente sur le schéma 3D le positionnement des poteaux objets de
renforcement. Pour plus de clarté, La figure A.2 de l’annexe 1 permet de positionner ces
poteaux là sur la vue en plan.

a)

Fig. 12 : Positionnement des poteaux 1 et 31

1. Poteau 1
Pour le poteau 1, nous avons procédé à 2 changements qui donnent des résultats similaires :

- Varier l’orientation du poteau d’un angle Gamma de 0° à 90° : ce changement


permet de diminuer le ratio de dimensionnement de 0,96 à 0,80.
- Ajouter des bras de forces : ce changement permet de diminuer le ratio de
dimensionnement de 0,96 à 0,79.
L’entreprise a donc le choix entre ces deux configurations et estimer celle qui est la plus
économique relativement aux équipes d’intervention qui leur sont propres.

21/65
2. Poteau 31
Pour le poteau 31, nous avons ajouté 2 bras de forces : qui ont permis de diminuer le ratio de
0,90 à 0,74. La figure 13 ci-dessous présente le positionnement de ces bras de force.

IPE 300

IPE 160

HEA 160

Fig. 13 : Renforcement du poteau 31 par ajout de bras de force

La figure présente aussi les dimensions du renfort à fabriquer par un IPE 160.

Pour des raisons de symétrie, le poteau du même portique devrait aussi être renforcé par le
même bras de force.

L’annexe 2 présente le détail de construction du bras de force, de ses platines et perçages.

La figure 14 rapport le dessin de définition de cet élément.

22/65
Fig. 14 : Dessin de définition du bras de force en IPE 160-renfort du poteau
31

VII. VERIFICATION DES PIEDS DE POTEAU


La vérification des pieds de poteaux correspond ici à la vérification des boulons de cisaillement
et de la force d’arrachement des boulons lorsqu’ils sont étirés.
- Le cisaillement est dû essentiellement aux forces nodales (dans le repère global) FY,
FZ et au moment MZ ;
- L’arrachement est dû essentiellement à la force FZ et aux moments MX et MY.

23/65
1. VERIFICATION AU CISAILLEMENT

a. Formulation des efforts par boulon


Les efforts de traction qui engendrent l’arrachement des boulons sont notés Ti (où i est l’indice
du boulon considéré). Les efforts de cisaillement sont notés Vi.

L’ensemble des équations (Système I) ci-dessous présente la formulation adoptée


relativement au repère global repris à la figure 15.

4 3

1 2

Fig. 15 : Transmissions de charge

24/65
𝐹𝑥 𝑀𝑌 𝑀𝑍
𝑇1 = − + (1)
4 2𝑏 2𝑎
𝐹𝑥 𝑀𝑌 𝑀𝑍
𝑇2 = − − (2)
4 2𝑏 2𝑎
𝐹𝑥 𝑀𝑌 𝑀𝑍
𝑇3 = + − (3)
4 2𝑏 2𝑎
𝐹𝑥 𝑀𝑌 𝑀𝑍
{ 𝑇4 = + + (4)
4 2𝑏 2𝑎
𝑉𝑌 𝑀𝑋 𝑏
𝑉𝑌1 = + (5)
4 2(𝑎2 + 𝑏 2 )
𝑉𝑌 𝑀𝑋 𝑎
𝑉𝑌2 = + (6)
4 2(𝑎2 + 𝑏 2 )
(𝑆𝑦𝑠𝑡è𝑚𝑒 𝐼) 𝑉𝑌 𝑀𝑋 𝑏
𝑉𝑌3 = − (7)
4 2(𝑎2 + 𝑏 2 )
𝑉𝑌 𝑀𝑋 𝑎
𝑉𝑌4 = − (8)
{ 4 2(𝑎2 + 𝑏 2 )
𝑉𝑍 𝑀𝑋 𝑎
𝑉𝑍1 = − (9)
4 2(𝑎2 + 𝑏 2 )
𝑉𝑍 𝑀𝑋 𝑏
𝑉𝑍2 = + (10)
4 2(𝑎2 + 𝑏 2 )
𝑉𝑍 𝑀𝑋 𝑎
𝑉𝑍3 = + (11)
4 2(𝑎2 + 𝑏 2 )
𝑉𝑍 𝑀𝑋 𝑏
𝑉𝑍4 = − (12)
{{ 4 2(𝑎2 + 𝑏 2 )

b. Vérification du cisaillement par boulon


Le cisaillement est justifié par la résultante des efforts de cisaillement.

Pour chaque boulon, la justification est faite suivant la condition de résistance suivante :

𝑉𝑅𝑑 𝑓𝑢𝑏 𝐴𝑠
𝑉𝐸𝑑 = √𝑉𝑌2 + 𝑉𝑍 ² ≤ = 0.6
𝛾𝑀𝑏 𝛾𝑀𝑏


VEd est la charge de dimensionnement
VRd est la résistance caractéristique au cisaillement
𝑓𝑢𝑏 : Résistance ultime à la traction
𝐴𝑠 : Section apparente de la vis
𝛾𝑀𝑏 =1,25

25/65
c. Résultats des calculs
Le calcul a été effectué sous MS Excel, à partir de la descente de charges fournie par le logiciel
de dimensionnement (RSA). Les tiges utilisées sont des tiges M30.

La figure 16 ci-dessous présente la note de calcul des boulons du poteau le plus sollicité
(poteau 27).

Fig. 16 : Note de calcul des boulons de scellement les plus sollicités (poteau
27, cas de charge 4-voir tab. 4)

Nous remarquons que les boulons sont vérifiés au cisaillement avec un coefficient de sécurité avoisinant
les 56.

2. VERIFICATION DE LA COMPRESSION LOCALISEE DE LA PLATINE

a. Formulation de la pression localisée


La platine fabriquée par l’acier S 235 (figure 4) est sujette à une compression localisée
effectuée par les écrous de fixation des tiges (boulons ou goujons). La vérification à la
compression locale est assurée par la formule suivante :

𝑇 𝑇
= 2 2 ) ≤ 𝜎𝑒 (13)
𝑆𝑅 𝜋(𝑑𝑒𝑥𝑡 − 𝑑𝑖𝑛𝑡


T : Effort de compression sous rondelle (N) (supposé négatif contrairement à
l’arrachement où l’effort T est supposé positif)

26/65
SR : Section de la rondelle (mm²)
dext : diamètre extérieur de la rondelle (mm)
dint : diamètre intérieur de la rondelle (mm)
e : résistance élastique de la platine (235 MPa)

b. Résultats des calculs


Le tableau 17 présente les résultats du calcul manuel de la pression localisée sous rondelle.

Les dimensions de la rondelle sont les suivantes :

Dext = 56 mm ;
Dint = 31 mm ;

Fig. 17 : Note de vérification de la pression localisée sous rondelle d’appuis

27/65
Annexes

28/65
Annexe 1
Fig. A.1 : Vue 3D de la structure et identification des files
File 2

File 3

File 1

File 4

29/65
Fig. A.2 : Vue de dessus de la structure File 3

File 4
File 2
Poteau 31
Poteau 1

File 1

30/65
Annexe 2

31/65
Annexe 3 :
Note de calcul détaillée
La description des Etats Limites de vérification est détaillée au tableau 4 de ce rapport.

 ELU_ANCIEN (actuel)

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 1 Poteaux_HEA_160
MEMBER: 27 POINT: 1 COORDINATE: x = 0.00 L =
0.00 m
--------------------------------------------------------------------------------------------------------------------------------------
--
LOADS:
Governing Load Case: 4 ELU_ANCIEN 1*1.35+2*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
----------------------------------------------------------------------------------------------------------------------------- ---------
--

SECTION PARAMETERS: HEA 160


h=152 mm gM0=1.00 gM1=1.00
b=160 mm Ay=3253 mm2 Az=1321 mm2 Ax=3877 mm2
tw=6 mm Iy=16729800 mm4 Iz=6155730 mm4 Ix=109000 mm4
tf=9 mm Wply=245167 mm3 Wplz=117635 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
INTERNAL FORCES AND CAPACITIES:
N,Ed = 21.81 kN My,Ed = 4.76 kN*m Mz,Ed = -3.54 kN*m Vy,Ed = -1.25 kN
Nc,Rd = 911.13 kN My,Ed,max = -14.96 kN*m Mz,Ed,max = 3.86 kN*m
Vy,T,Rd = 441.34 kN
Nb,Rd = 439.43 kN My,c,Rd = 57.61 kN*m Mz,c,Rd = 27.64 kN*m Vz,Ed = -3.34 kN
MN,y,Rd = 57.61 kN*m MN,z,Rd = 27.64 kN*m Vz,T,Rd = 179.24 kN
Tt,Ed = -0.00 kN*m
Class of section = 1
----------------------------------------------------------------------------------------------------------------------------- ---------
--

LATERAL BUCKLING PARAMETERS:


----------------------------------------------------------------------------------------------------------------------------- ---------
--
BUCKLING PARAMETERS:

About y axis: About z axis:

32/65
Ly = 5.90 m Lam_y = 0.67 Lz = 5.90 m Lam_z = 1.10
Lcr,y = 4.13 m Xy = 0.80 Lcr,z = 4.13 m Xz = 0.48
Lamy = 62.87 kyy = 1.01 Lamz = 103.65 kyz = 0.72
--------------------------------------------------------------------------------------------------------------------------------------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nc,Rd = 0.02 < 1.00 (6.2.4.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^1.00 = 0.13 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.00 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.02 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Global stability check of member:
Lambda,y = 62.87 < Lambda,max = 210.00 Lambda,z = 103.65 < Lambda,max = 210.00 STABLE
N,Ed/(Xy*N,Rk/gM1) + kyy*My,Ed,max/(XLT*My,Rk/gM1) + kyz*Mz,Ed,max/(Mz,Rk/gM1) = 0.39 < 1.00
(6.3.3.(4))
N,Ed/(Xz*N,Rk/gM1) + kzy*My,Ed,max/(XLT*My,Rk/gM1) + kzz*Mz,Ed,max/(Mz,Rk/gM1) = 0.33 < 1.00
(6.3.3.(4))
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 2 Traverses_IPE_300_cadre
MEMBER: 75 POINT: 1 COORDINATE: x = 0.45 L =
2.73 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 4 ELU_ANCIEN 1*1.35+2*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
----------------------------------------------------------------------------------------------------------------------------- ---------
--

SECTION PARAMETERS: IPE 300


h=300 mm gM0=1.00 gM1=1.00
b=150 mm Ay=3616 mm2 Az=2568 mm2 Ax=5381 mm2
tw=7 mm Iy=83561100 mm4 Iz=6037790 mm4 Ix=194700 mm4
tf=11 mm Wply=628399 mm3 Wplz=125222 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
INTERNAL FORCES AND CAPACITIES:
N,Ed = 0.19 kN My,Ed = 15.65 kN*m Mz,Ed = -3.70 kN*m Vy,Ed = -2.30 kN
Nc,Rd = 1264.58 kN My,Ed,max = 15.65 kN*m Mz,Ed,max = 4.00 kN*m Vy,T,Rd = 490.55 kN
Nb,Rd = 1264.58 kN My,c,Rd = 147.67 kN*m Mz,c,Rd = 29.43 kN*m Vz,Ed = -4.47 kN
MN,y,Rd = 147.67 kN*m MN,z,Rd = 29.43 kN*m Vz,T,Rd = 348.41 kN
Mb,Rd = 147.67 kN*m Tt,Ed = -0.00 kN*m
Class of section = 1

33/65
----------------------------------------------------------------------------------------------------------------------------- ---------
--

LATERAL BUCKLING PARAMETERS:


z = 1.00 Mcr = 458.61 kN*m Curve,LT - b XLT = 0.93
Lcr,upp=3.04 m Lam_LT = 0.57 fi,LT = 0.65 XLT,mod = 1.00
----------------------------------------------------------------------------------------------------------------------------- ---------
--
BUCKLING PARAMETERS:

About y axis: About z axis:


kyy = 1.00 kzz = 1.00
----------------------------------------------------------------------------------------------------------------------------- ---------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nc,Rd = 0.00 < 1.00 (6.2.4.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^1.00 = 0.14 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.00 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.01 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Global stability check of member:
My,Ed,max/Mb,Rd = 0.11 < 1.00 (6.3.2.1.(1))
N,Ed/(Xy*N,Rk/gM1) + kyy*My,Ed,max/(XLT*My,Rk/gM1) + kyz*Mz,Ed,max/(Mz,Rk/gM1) = 0.24 < 1.00
(6.3.3.(4))
N,Ed/(Xz*N,Rk/gM1) + kzy*My,Ed,max/(XLT*My,Rk/gM1) + kzz*Mz,Ed,max/(Mz,Rk/gM1) = 0.24 < 1.00
(6.3.3.(4))
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 3 Traverses_IPE_160
MEMBER: 49 POINT: 3 COORDINATE: x = 0.45 L =
3.22 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 4 ELU_ANCIEN 1*1.35+2*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
----------------------------------------------------------------------------------------------------------------------------- ---------
--

SECTION PARAMETERS: IPE 160


h=160 mm gM0=1.00 gM1=1.00
b=82 mm Ay=1373 mm2 Az=966 mm2 Ax=2009 mm2
tw=5 mm Iy=8692930 mm4 Iz=683145 mm4 Ix=35300 mm4
tf=7 mm Wply=123868 mm3 Wplz=26101 mm3

34/65
----------------------------------------------------------------------------------------------------------------------------- ---------
--
INTERNAL FORCES AND CAPACITIES:
N,Ed = 0.39 kN My,Ed = 7.68 kN*m Mz,Ed = -0.63 kN*m Vy,Ed = 0.39 kN
Nc,Rd = 472.15 kN My,Ed,max = 7.68 kN*m Mz,Ed,max = 0.63 kN*m Vy,T,Rd = 186.22 kN
Nb,Rd = 472.15 kN My,c,Rd = 29.11 kN*m Mz,c,Rd = 6.13 kN*m Vz,Ed = 3.35 kN
MN,y,Rd = 29.11 kN*m MN,z,Rd = 6.13 kN*m Vz,T,Rd = 130.99 kN
Mb,Rd = 15.83 kN*m Tt,Ed = 0.00 kN*m
Class of section = 1
----------------------------------------------------------------------------------------------------------------------------- ---------
--

LATERAL BUCKLING PARAMETERS:


z = 1.00 Mcr = 18.26 kN*m Curve,LT - b XLT = 0.54
Lcr,upp=3.58 m Lam_LT = 1.26 fi,LT = 1.24 XLT,mod = 0.54
----------------------------------------------------------------------------------------------------------------------------- ---------
--
BUCKLING PARAMETERS:

About y axis: About z axis:


kyy = 1.00 kzz = 1.00
----------------------------------------------------------------------------------------------------------------------------- ---------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nc,Rd = 0.00 < 1.00 (6.2.4.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^1.00 = 0.17 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.00 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.03 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Global stability check of member:
My,Ed,max/Mb,Rd = 0.49 < 1.00 (6.3.2.1.(1))
N,Ed/(Xy*N,Rk/gM1) + kyy*My,Ed,max/(XLT*My,Rk/gM1) + kyz*Mz,Ed,max/(Mz,Rk/gM1) = 0.59 < 1.00
(6.3.3.(4))
N,Ed/(Xz*N,Rk/gM1) + kzy*My,Ed,max/(XLT*My,Rk/gM1) + kzz*Mz,Ed,max/(Mz,Rk/gM1) = 0.59 < 1.00
(6.3.3.(4))
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 4 Traverses_IPE_120
MEMBER: 108 POINT: 1 COORDINATE: x = 0.55 L =
3.35 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 4 ELU_ANCIEN 1*1.35+2*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa

35/65
--------------------------------------------------------------------------------------------------------------------------------------
--

SECTION PARAMETERS: IPE 120


h=120 mm gM0=1.00 gM1=1.00
b=64 mm Ay=910 mm2 Az=631 mm2 Ax=1321 mm2
tw=4 mm Iy=3177530 mm4 Iz=276682 mm4 Ix=17100 mm4
tf=6 mm Wply=60729 mm3 Wplz=13581 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
INTERNAL FORCES AND CAPACITIES:
N,Ed = -0.48 kN My,Ed = 6.55 kN*m Mz,Ed = 0.17 kN*m Vy,Ed = 0.13 kN
Nt,Rd = 310.44 kN My,pl,Rd = 14.27 kN*m Mz,pl,Rd = 3.19 kN*m Vy,T,Rd = 123.05 kN
My,c,Rd = 14.27 kN*m Mz,c,Rd = 3.19 kN*m Vz,Ed = -2.23 kN
MN,y,Rd = 14.27 kN*m MN,z,Rd = 3.19 kN*m Vz,T,Rd = 85.34 kN
Mb,Rd = 8.02 kN*m Tt,Ed = -0.00 kN*m
Class of section = 1
----------------------------------------------------------------------------------------------------------------------------- ---------
--

LATERAL BUCKLING PARAMETERS:


z = 1.00 Mcr = 9.43 kN*m Curve,LT - b XLT = 0.56
Lcr,upp=3.04 m Lam_LT = 1.23 fi,LT = 1.21 XLT,mod = 0.56
----------------------------------------------------------------------------------------------------------------------------- ---------
--
BUCKLING PARAMETERS:

About y axis: About z axis:

----------------------------------------------------------------------------------------------------------------------------- ---------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nt,Rd = 0.00 < 1.00 (6.2.3.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^1.00 = 0.26 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.00 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.03 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.01 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.01 < 1.00 (6.2.6)
Global stability check of member:
My,Ed/Mb,Rd = 0.82 < 1.00 (6.3.2.1.(1))
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 5 Traverses_IPE_200_cadre
MEMBER: 54 POINT: 3 COORDINATE: x = 0.50 L =
2.75 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 4 ELU_ANCIEN 1*1.35+2*1.95

36/65
--------------------------------------------------------------------------------------------------------------------------------------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
----------------------------------------------------------------------------------------------------------------------------- ---------
--

SECTION PARAMETERS: IPE 200


h=200 mm gM0=1.00 gM1=1.00
b=100 mm Ay=1958 mm2 Az=1400 mm2 Ax=2848 mm2
tw=6 mm Iy=19431700 mm4 Iz=1423680 mm4 Ix=64600 mm4
tf=9 mm Wply=220657 mm3 Wplz=44614 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
INTERNAL FORCES AND CAPACITIES:
N,Ed = 1.07 kN My,Ed = 7.10 kN*m Mz,Ed = -1.09 kN*m Vy,Ed = 0.73 kN
Nc,Rd = 669.38 kN My,Ed,max = 7.10 kN*m Mz,Ed,max = 1.18 kN*m Vy,T,Rd = 265.49 kN
Nb,Rd = 669.38 kN My,c,Rd = 51.85 kN*m Mz,c,Rd = 10.48 kN*m Vz,Ed = 2.83 kN
MN,y,Rd = 51.85 kN*m MN,z,Rd = 10.48 kN*m Vz,T,Rd = 189.87 kN
Mb,Rd = 35.34 kN*m Tt,Ed = 0.00 kN*m
Class of section = 1
----------------------------------------------------------------------------------------------------------------------------- ---------
--

LATERAL BUCKLING PARAMETERS:


z = 1.00 Mcr = 48.91 kN*m Curve,LT - b XLT = 0.68
Lcr,upp=2.75 m Lam_LT = 1.03 fi,LT = 1.00 XLT,mod = 0.68
----------------------------------------------------------------------------------------------------------------------------- ---------
--
BUCKLING PARAMETERS:

About y axis: About z axis:


kyy = 1.00 kzz = 1.00
----------------------------------------------------------------------------------------------------------------------------- ---------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nc,Rd = 0.00 < 1.00 (6.2.4.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^1.00 = 0.12 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.00 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.01 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Global stability check of member:
My,Ed,max/Mb,Rd = 0.20 < 1.00 (6.3.2.1.(1))
N,Ed/(Xy*N,Rk/gM1) + kyy*My,Ed,max/(XLT*My,Rk/gM1) + kyz*Mz,Ed,max/(Mz,Rk/gM1) = 0.31 < 1.00
(6.3.3.(4))
N,Ed/(Xz*N,Rk/gM1) + kzy*My,Ed,max/(XLT*My,Rk/gM1) + kzz*Mz,Ed,max/(Mz,Rk/gM1) = 0.31 < 1.00
(6.3.3.(4))
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification

37/65
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 6 Poutre_ceinture_IPE_300
MEMBER: 78 POINT: 3 COORDINATE: x = 1.00 L =
12.87 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 4 ELU_ANCIEN 1*1.35+2*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
--------------------------------------------------------------------------------------------------------------------------------------
--

SECTION PARAMETERS: IPE 300


h=300 mm gM0=1.00 gM1=1.00
b=150 mm Ay=3616 mm2 Az=2568 mm2 Ax=5381 mm2
tw=7 mm Iy=83561100 mm4 Iz=6037790 mm4 Ix=194700 mm4
tf=11 mm Wply=628399 mm3 Wplz=125222 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
INTERNAL FORCES AND CAPACITIES:
N,Ed = 0.85 kN My,Ed = -0.56 kN*m Mz,Ed = 0.70 kN*m Vy,Ed = -0.22 kN
Nc,Rd = 1264.58 kN My,Ed,max = -33.44 kN*m Mz,Ed,max = -1.43 kN*m
Vy,T,Rd = 489.78 kN
Nb,Rd = 1264.58 kN My,c,Rd = 147.67 kN*m Mz,c,Rd = 29.43 kN*m Vz,Ed = -4.86 kN
MN,y,Rd = 147.67 kN*m MN,z,Rd = 29.43 kN*m Vz,T,Rd = 348.04 kN
Mb,Rd = 108.87 kN*m Tt,Ed = -0.01 kN*m
Class of section = 1
----------------------------------------------------------------------------------------------------------------------------- ---------
--

LATERAL BUCKLING PARAMETERS:


z = 1.00 Mcr = 129.33 kN*m Curve,LT - b XLT = 0.66
Lcr,low=6.43 m Lam_LT = 1.07 fi,LT = 1.04 XLT,mod = 0.74
----------------------------------------------------------------------------------------------------------------------------- ---------
--
BUCKLING PARAMETERS:

About y axis: About z axis:


kyy = 1.00 kzz = 1.00
----------------------------------------------------------------------------------------------------------------------------- ---------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nc,Rd = 0.00 < 1.00 (6.2.4.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^1.00 = 0.02 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.00 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.01 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Global stability check of member:
My,Ed,max/Mb,Rd = 0.31 < 1.00 (6.3.2.1.(1))
N,Ed/(Xy*N,Rk/gM1) + kyy*My,Ed,max/(XLT*My,Rk/gM1) + kyz*Mz,Ed,max/(Mz,Rk/gM1) = 0.36 < 1.00
(6.3.3.(4))
N,Ed/(Xz*N,Rk/gM1) + kzy*My,Ed,max/(XLT*My,Rk/gM1) + kzz*Mz,Ed,max/(Mz,Rk/gM1) = 0.36 < 1.00
(6.3.3.(4))

38/65
---------------------------------------------------------------------------------------------------------------- ----------------------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 7 Poutre_ceinture_IPE_240
MEMBER: 70 POINT: 1 COORDINATE: x = 0.00 L =
0.00 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 4 ELU_ANCIEN 1*1.35+2*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
----------------------------------------------------------------------------------------------------------------------------- ---------
--

SECTION PARAMETERS: IPE 240


h=240 mm gM0=1.00 gM1=1.00
b=120 mm Ay=2731 mm2 Az=1914 mm2 Ax=3912 mm2
tw=6 mm Iy=38916300 mm4 Iz=2836340 mm4 Ix=116000 mm4
tf=10 mm Wply=366679 mm3 Wplz=73927 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
INTERNAL FORCES AND CAPACITIES:
N,Ed = 3.54 kN My,Ed = -31.52 kN*m Mz,Ed = 0.14 kN*m Vy,Ed = 0.05 kN
Nc,Rd = 919.23 kN My,Ed,max = -31.52 kN*m Mz,Ed,max = 1.63 kN*m
Vy,T,Rd = 369.70 kN
Nb,Rd = 919.23 kN My,c,Rd = 86.17 kN*m Mz,c,Rd = 17.37 kN*m Vz,Ed = 12.00 kN
MN,y,Rd = 86.17 kN*m MN,z,Rd = 17.37 kN*m Vz,T,Rd = 259.36 kN
Mb,Rd = 53.94 kN*m Tt,Ed = -0.01 kN*m
Class of section = 1
----------------------------------------------------------------------------------------------------------------------------- ---------
--

LATERAL BUCKLING PARAMETERS:


z = 1.00 Mcr = 60.88 kN*m Curve,LT - b XLT = 0.59
Lcr,low=6.00 m Lam_LT = 1.19 fi,LT = 1.16 XLT,mod = 0.63
----------------------------------------------------------------------------------------------------------------------------- ---------
--
BUCKLING PARAMETERS:

About y axis: About z axis:


kyy = 1.00 kzz = 1.00
----------------------------------------------------------------------------------------------------------------------------- ---------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nc,Rd = 0.00 < 1.00 (6.2.4.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^1.00 = 0.14 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.00 < 1.00 (6.2.6-7)

39/65
Vz,Ed/Vz,T,Rd = 0.05 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.01 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Global stability check of member:
My,Ed,max/Mb,Rd = 0.58 < 1.00 (6.3.2.1.(1))
N,Ed/(Xy*N,Rk/gM1) + kyy*My,Ed,max/(XLT*My,Rk/gM1) + kyz*Mz,Ed,max/(Mz,Rk/gM1) = 0.68 < 1.00
(6.3.3.(4))
N,Ed/(Xz*N,Rk/gM1) + kzy*My,Ed,max/(XLT*My,Rk/gM1) + kzz*Mz,Ed,max/(Mz,Rk/gM1) = 0.68 < 1.00
(6.3.3.(4))
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 8 Traverses_IPE_140
MEMBER: 118 POINT: 1 COORDINATE: x = 0.68 L =
4.17 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 4 ELU_ANCIEN 1*1.35+2*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
--------------------------------------------------------------------------------------------------------------------------------------
--

SECTION PARAMETERS: IPE 140


h=140 mm gM0=1.00 gM1=1.00
b=73 mm Ay=1115 mm2 Az=764 mm2 Ax=1643 mm2
tw=5 mm Iy=5412240 mm4 Iz=449178 mm4 Ix=25400 mm4
tf=7 mm Wply=88349 mm3 Wplz=19247 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
INTERNAL FORCES AND CAPACITIES:
N,Ed = 0.01 kN My,Ed = 7.14 kN*m Mz,Ed = 0.18 kN*m Vy,Ed = 0.13 kN
Nc,Rd = 386.01 kN My,Ed,max = 7.14 kN*m Mz,Ed,max = -0.36 kN*m Vy,T,Rd = 151.29 kN
Nb,Rd = 386.01 kN My,c,Rd = 20.76 kN*m Mz,c,Rd = 4.52 kN*m Vz,Ed = -3.41 kN
MN,y,Rd = 20.76 kN*m MN,z,Rd = 4.52 kN*m Vz,T,Rd = 103.68 kN
Mb,Rd = 12.07 kN*m Tt,Ed = -0.00 kN*m
Class of section = 1
----------------------------------------------------------------------------------------------------------------------------- ---------
--

LATERAL BUCKLING PARAMETERS:


z = 1.00 Mcr = 14.51 kN*m Curve,LT - b XLT = 0.58
Lcr,upp=3.09 m Lam_LT = 1.20 fi,LT = 1.17 XLT,mod = 0.58
----------------------------------------------------------------------------------------------------------------------------- ---------
--
BUCKLING PARAMETERS:

About y axis: About z axis:

40/65
kyy = 1.00 kzz = 1.00
----------------------------------------------------------------------------------------------------------------------------- ---------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nc,Rd = 0.00 < 1.00 (6.2.4.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^1.00 = 0.16 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.00 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.03 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Global stability check of member:
My,Ed,max/Mb,Rd = 0.59 < 1.00 (6.3.2.1.(1))
N,Ed/(Xy*N,Rk/gM1) + kyy*My,Ed,max/(XLT*My,Rk/gM1) + kyz*Mz,Ed,max/(Mz,Rk/gM1) = 0.67 < 1.00
(6.3.3.(4))
N,Ed/(Xz*N,Rk/gM1) + kzy*My,Ed,max/(XLT*My,Rk/gM1) + kzz*Mz,Ed,max/(Mz,Rk/gM1) = 0.67 < 1.00
(6.3.3.(4))
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 9 Tube_80x80_Support_cable
MEMBER: 166 POINT: 3 COORDINATE: x = 0.51 L =
0.51 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 4 ELU_ANCIEN 1*1.35+2*1.95
--------------------------------------------------------------------------------------------------------------------------------------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
----------------------------------------------------------------------------------------------------------------------------- ---------
--

SECTION PARAMETERS: TCARRE 80x80x3.2


h=80 mm gM0=1.00 gM1=1.00
b=80 mm Ay=489 mm2 Az=489 mm2 Ax=978 mm2
tw=3 mm Iy=958500 mm4 Iz=958500 mm4 Ix=1477000 mm4
tf=3 mm Wply=28328 mm3 Wplz=28328 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
INTERNAL FORCES AND CAPACITIES:
N,Ed = -1.01 kN My,Ed = 0.01 kN*m Mz,Ed = 0.71 kN*m Vy,Ed = -1.50 kN
Nt,Rd = 229.85 kN My,pl,Rd = 6.66 kN*m Mz,pl,Rd = 6.66 kN*m Vy,T,Rd = 54.15 kN
My,c,Rd = 6.66 kN*m Mz,c,Rd = 6.66 kN*m Vz,Ed = -0.79 kN
MN,y,Rd = 6.66 kN*m MN,z,Rd = 6.66 kN*m Vz,T,Rd = 54.15 kN
Tt,Ed = -0.94 kN*m
Class of section = 1
----------------------------------------------------------------------------------------------------------------------------- ---------
--

41/65
LATERAL BUCKLING PARAMETERS:
--------------------------------------------------------------------------------------------------------------------------------------
--
BUCKLING PARAMETERS:

About y axis: About z axis:

----------------------------------------------------------------------------------------------------------------------------- ---------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nt,Rd = 0.00 < 1.00 (6.2.3.(1))
(My,Ed/MN,y,Rd)^ 1.66 + (Mz,Ed/MN,z,Rd)^1.66 = 0.02 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.03 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.01 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.18 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.18 < 1.00 (6.2.6)
--------------------------------------------------------------------------------------------------------------------------------------
--
Section OK !!!

42/65
 ELS_ANCIEN (actuel)

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 1 Poteaux_HEA_160
MEMBER: 1 POINT: COORDINATE:
----------------------------------------------------------------------------------------------------------------------------- ---------
--

SECTION PARAMETERS: HEA 160


ht=152 mm
bf=160 mm Ay=2880 mm2 Az=912 mm2 Ax=3877 mm2
tw=6 mm Iy=16729800 mm4 Iz=6155730 mm4 Ix=109000 mm4
tf=9 mm Wely=220129 mm3 Welz=76947 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LIMIT DISPLACEMENTS

Deflections (LOCAL SYSTEM): Not analyzed

Displacements (GLOBAL SYSTEM):


vx = 16 mm < vx max = L/250.00 = 24 mm Verified
Governing Load Case: 5 ELS_ANCIEN 1*1.00+2*1.30
vy = 9 mm < vy max = L/250.00 = 24 mm Verified
Governing Load Case: 5 ELS_ANCIEN 1*1.00+2*1.30
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 2 Traverses_IPE_300_cadre
MEMBER: 75 POINT: COORDINATE:
--------------------------------------------------------------------------------------------------------------------------------------
--

SECTION PARAMETERS: IPE 300


ht=300 mm
bf=150 mm Ay=3210 mm2 Az=2130 mm2 Ax=5381 mm2
tw=7 mm Iy=83561100 mm4 Iz=6037790 mm4 Ix=194700 mm4
tf=11 mm Wely=557074 mm3 Welz=80504 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LIMIT DISPLACEMENTS

Deflections (LOCAL SYSTEM):

43/65
uy = 4 mm < uy max = L/200.00 = 30 mm Verified
Governing Load Case: 5 ELS_ANCIEN 1*1.00+2*1.30
uz = 2 mm < uz max = L/200.00 = 30 mm Verified
Governing Load Case: 5 ELS_ANCIEN 1*1.00+2*1.30

Displacements (GLOBAL SYSTEM): Not analyzed


----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
--------------------------------------------------------------------------------------------------------------------------------------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 3 Traverses_IPE_160
MEMBER: 49 POINT: COORDINATE:
----------------------------------------------------------------------------------------------------------------------------- ---------
--

SECTION PARAMETERS: IPE 160


ht=160 mm
bf=82 mm Ay=1214 mm2 Az=800 mm2 Ax=2009 mm2
tw=5 mm Iy=8692930 mm4 Iz=683145 mm4 Ix=35300 mm4
tf=7 mm Wely=108662 mm3 Welz=16662 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LIMIT DISPLACEMENTS

Deflections (LOCAL SYSTEM):


uy = 6 mm < uy max = L/200.00 = 36 mm Verified
Governing Load Case: 5 ELS_ANCIEN 1*1.00+2*1.30
uz = 10 mm < uz max = L/200.00 = 36 mm Verified
Governing Load Case: 5 ELS_ANCIEN 1*1.00+2*1.30

Displacements (GLOBAL SYSTEM): Not analyzed


----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 4 Traverses_IPE_120
MEMBER: 107 POINT: COORDINATE:
----------------------------------------------------------------------------------------------------------------------------- ---------
--

SECTION PARAMETERS: IPE 120


ht=120 mm
bf=64 mm Ay=806 mm2 Az=528 mm2 Ax=1321 mm2

44/65
tw=4 mm Iy=3177530 mm4 Iz=276682 mm4 Ix=17100 mm4
tf=6 mm Wely=52959 mm3 Welz=8646 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LIMIT DISPLACEMENTS

Deflections (LOCAL SYSTEM):


uy = 4 mm < uy max = L/200.00 = 30 mm Verified
Governing Load Case: 5 ELS_ANCIEN 1*1.00+2*1.30
uz = 22 mm < uz max = L/200.00 = 30 mm Verified
Governing Load Case: 5 ELS_ANCIEN 1*1.00+2*1.30

Displacements (GLOBAL SYSTEM): Not analyzed


----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 5 Traverses_IPE_200_cadre
MEMBER: 54 POINT: COORDINATE:
--------------------------------------------------------------------------------------------------------------------------------------
--

SECTION PARAMETERS: IPE 200


ht=200 mm
bf=100 mm Ay=1700 mm2 Az=1120 mm2 Ax=2848 mm2
tw=6 mm Iy=19431700 mm4 Iz=1423680 mm4 Ix=64600 mm4
tf=9 mm Wely=194317 mm3 Welz=28474 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LIMIT DISPLACEMENTS

Deflections (LOCAL SYSTEM):


uy = 3 mm < uy max = L/200.00 = 27 mm Verified
Governing Load Case: 5 ELS_ANCIEN 1*1.00+2*1.30
uz = 3 mm < uz max = L/200.00 = 27 mm Verified
Governing Load Case: 5 ELS_ANCIEN 1*1.00+2*1.30

Displacements (GLOBAL SYSTEM): Not analyzed


----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
--------------------------------------------------------------------------------------------------------------------------------------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 6 Poutre_ceinture_IPE_300
MEMBER: 48 POINT: COORDINATE:

45/65
----------------------------------------------------------------------------------------------------------------------------- ---------
--

SECTION PARAMETERS: IPE 300


ht=300 mm
bf=150 mm Ay=3210 mm2 Az=2130 mm2 Ax=5381 mm2
tw=7 mm Iy=83561100 mm4 Iz=6037790 mm4 Ix=194700 mm4
tf=11 mm Wely=557074 mm3 Welz=80504 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LIMIT DISPLACEMENTS

Deflections (LOCAL SYSTEM):


uy = 7 mm < uy max = L/200.00 = 49 mm Verified
Governing Load Case: 5 ELS_ANCIEN 1*1.00+2*1.30
uz = 6 mm < uz max = L/200.00 = 49 mm Verified
Governing Load Case: 5 ELS_ANCIEN 1*1.00+2*1.30

Displacements (GLOBAL SYSTEM): Not analyzed


----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 7 Poutre_ceinture_IPE_240
MEMBER: 70 POINT: COORDINATE:
--------------------------------------------------------------------------------------------------------------------------------------
--

SECTION PARAMETERS: IPE 240


ht=240 mm
bf=120 mm Ay=2352 mm2 Az=1488 mm2 Ax=3912 mm2
tw=6 mm Iy=38916300 mm4 Iz=2836340 mm4 Ix=116000 mm4
tf=10 mm Wely=324302 mm3 Welz=47272 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LIMIT DISPLACEMENTS

Deflections (LOCAL SYSTEM):


uy = 8 mm < uy max = L/200.00 = 60 mm Verified
Governing Load Case: 5 ELS_ANCIEN 1*1.00+2*1.30
uz = 27 mm < uz max = L/200.00 = 60 mm Verified
Governing Load Case: 5 ELS_ANCIEN 1*1.00+2*1.30

Displacements (GLOBAL SYSTEM): Not analyzed


----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
--------------------------------------------------------------------------------------------------------------------------------------
--

46/65
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 8 Traverses_IPE_140
MEMBER: 118 POINT: COORDINATE:
--------------------------------------------------------------------------------------------------------------------------------------
--

SECTION PARAMETERS: IPE 140


ht=140 mm
bf=73 mm Ay=1007 mm2 Az=658 mm2 Ax=1643 mm2
tw=5 mm Iy=5412240 mm4 Iz=449178 mm4 Ix=25400 mm4
tf=7 mm Wely=77318 mm3 Welz=12306 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LIMIT DISPLACEMENTS

Deflections (LOCAL SYSTEM):


uy = 3 mm < uy max = L/200.00 = 31 mm Verified
Governing Load Case: 5 ELS_ANCIEN 1*1.00+2*1.30
uz = 14 mm < uz max = L/200.00 = 31 mm Verified
Governing Load Case: 5 ELS_ANCIEN 1*1.00+2*1.30

Displacements (GLOBAL SYSTEM): Not analyzed


--------------------------------------------------------------------------------------------------------------------------------------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 9 Tube_80x80_Support_cable
MEMBER: 261 Beam_261 POINT: COORDINATE:
----------------------------------------------------------------------------------------------------------------------------- ---------
--

SECTION PARAMETERS: TCARRE 80x80x3.2


ht=80 mm
bf=80 mm Ay=489 mm2 Az=489 mm2 Ax=978 mm2
tw=3 mm Iy=958500 mm4 Iz=958500 mm4 Ix=1477000 mm4
tf=3 mm Wely=23962 mm3 Welz=23962 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LIMIT DISPLACEMENTS

Deflections (LOCAL SYSTEM):


uy = 6 mm < uy max = L/200.00 = 60 mm Verified
Governing Load Case: 5 ELS_ANCIEN 1*1.00+2*1.30
uz = 37 mm < uz max = L/200.00 = 60 mm Verified
Governing Load Case: 5 ELS_ANCIEN 1*1.00+2*1.30

Displacements (GLOBAL SYSTEM): Not analyzed

47/65
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

48/65
 ELU_NOUVELLE

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 1 Poteaux_HEA_160
MEMBER: 27 POINT: 1 COORDINATE: x = 0.00 L =
0.00 m
--------------------------------------------------------------------------------------------------------------------------------------
--
LOADS:
Governing Load Case: 6 ELU_NOUVELLE 1*1.35+3*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
--------------------------------------------------------------------------------------------------------------------------------------
--

SECTION PARAMETERS: HEA 160


h=152 mm gM0=1.00 gM1=1.00
b=160 mm Ay=3253 mm2 Az=1321 mm2 Ax=3877 mm2
tw=6 mm Iy=16729800 mm4 Iz=6155730 mm4 Ix=109000 mm4
tf=9 mm Wply=245167 mm3 Wplz=117635 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
INTERNAL FORCES AND CAPACITIES:
N,Ed = 20.38 kN My,Ed = 3.17 kN*m Mz,Ed = -4.19 kN*m Vy,Ed = -1.47 kN
Nc,Rd = 911.13 kN My,Ed,max = -12.87 kN*m Mz,Ed,max = 4.49 kN*m
Vy,T,Rd = 441.34 kN
Nb,Rd = 439.43 kN My,c,Rd = 57.61 kN*m Mz,c,Rd = 27.64 kN*m Vz,Ed = -2.72 kN
MN,y,Rd = 57.61 kN*m MN,z,Rd = 27.64 kN*m Vz,T,Rd = 179.24 kN
Tt,Ed = -0.00 kN*m
Class of section = 1
----------------------------------------------------------------------------------------------------------------------------- ---------
--

LATERAL BUCKLING PARAMETERS:


--------------------------------------------------------------------------------------------------------------------------------------
--
BUCKLING PARAMETERS:

About y axis: About z axis:


Ly = 5.90 m Lam_y = 0.67 Lz = 5.90 m Lam_z = 1.10
Lcr,y = 4.13 m Xy = 0.80 Lcr,z = 4.13 m Xz = 0.48
Lamy = 62.87 kyy = 1.01 Lamz = 103.65 kyz = 0.72
------------------------------------------------------------------------------------------------------------- -------------------------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nc,Rd = 0.02 < 1.00 (6.2.4.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^1.00 = 0.15 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.00 < 1.00 (6.2.6-7)

49/65
Vz,Ed/Vz,T,Rd = 0.02 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Global stability check of member:
Lambda,y = 62.87 < Lambda,max = 210.00 Lambda,z = 103.65 < Lambda,max = 210.00 STABLE
N,Ed/(Xy*N,Rk/gM1) + kyy*My,Ed,max/(XLT*My,Rk/gM1) + kyz*Mz,Ed,max/(Mz,Rk/gM1) = 0.37 < 1.00
(6.3.3.(4))
N,Ed/(Xz*N,Rk/gM1) + kzy*My,Ed,max/(XLT*My,Rk/gM1) + kzz*Mz,Ed,max/(Mz,Rk/gM1) = 0.33 < 1.00
(6.3.3.(4))
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 2 Traverses_IPE_300_cadre
MEMBER: 75 POINT: 1 COORDINATE: x = 0.45 L =
2.73 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 6 ELU_NOUVELLE 1*1.35+3*1.95
--------------------------------------------------------------------------------------------------------------------------------------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
----------------------------------------------------------------------------------------------------------------------------- ---------
--

SECTION PARAMETERS: IPE 300


h=300 mm gM0=1.00 gM1=1.00
b=150 mm Ay=3616 mm2 Az=2568 mm2 Ax=5381 mm2
tw=7 mm Iy=83561100 mm4 Iz=6037790 mm4 Ix=194700 mm4
tf=11 mm Wply=628399 mm3 Wplz=125222 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
INTERNAL FORCES AND CAPACITIES:
N,Ed = 0.13 kN My,Ed = 14.17 kN*m Mz,Ed = -4.62 kN*m Vy,Ed = -2.84 kN
Nc,Rd = 1264.58 kN My,Ed,max = 14.17 kN*m Mz,Ed,max = 4.88 kN*m Vy,T,Rd = 490.50 kN
Nb,Rd = 1264.58 kN My,c,Rd = 147.67 kN*m Mz,c,Rd = 29.43 kN*m Vz,Ed = -4.09 kN
MN,y,Rd = 147.67 kN*m MN,z,Rd = 29.43 kN*m Vz,T,Rd = 348.38 kN
Mb,Rd = 147.67 kN*m Tt,Ed = -0.00 kN*m
Class of section = 1
----------------------------------------------------------------------------------------------------------------------------- ---------
--

LATERAL BUCKLING PARAMETERS:


z = 1.00 Mcr = 543.69 kN*m Curve,LT - b XLT = 0.95
Lcr,upp=3.04 m Lam_LT = 0.52 fi,LT = 0.62 XLT,mod = 1.00
----------------------------------------------------------------------------------------------------------------------------- ---------
--
BUCKLING PARAMETERS:

About y axis: About z axis:

50/65
kyy = 1.00 kzz = 1.00
----------------------------------------------------------------------------------------------------------------------------- ---------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nc,Rd = 0.00 < 1.00 (6.2.4.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^1.00 = 0.17 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.01 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.01 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Global stability check of member:
My,Ed,max/Mb,Rd = 0.10 < 1.00 (6.3.2.1.(1))
N,Ed/(Xy*N,Rk/gM1) + kyy*My,Ed,max/(XLT*My,Rk/gM1) + kyz*Mz,Ed,max/(Mz,Rk/gM1) = 0.26 < 1.00
(6.3.3.(4))
N,Ed/(Xz*N,Rk/gM1) + kzy*My,Ed,max/(XLT*My,Rk/gM1) + kzz*Mz,Ed,max/(Mz,Rk/gM1) = 0.26 < 1.00
(6.3.3.(4))
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 3 Traverses_IPE_160
MEMBER: 49 POINT: 3 COORDINATE: x = 0.45 L =
3.22 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 6 ELU_NOUVELLE 1*1.35+3*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
----------------------------------------------------------------------------------------------------------------------------- ---------
--

SECTION PARAMETERS: IPE 160


h=160 mm gM0=1.00 gM1=1.00
b=82 mm Ay=1373 mm2 Az=966 mm2 Ax=2009 mm2
tw=5 mm Iy=8692930 mm4 Iz=683145 mm4 Ix=35300 mm4
tf=7 mm Wply=123868 mm3 Wplz=26101 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
INTERNAL FORCES AND CAPACITIES:
N,Ed = 0.29 kN My,Ed = 6.87 kN*m Mz,Ed = -0.77 kN*m Vy,Ed = 0.48 kN
Nc,Rd = 472.15 kN My,Ed,max = 6.87 kN*m Mz,Ed,max = -0.77 kN*m Vy,T,Rd = 186.22 kN
Nb,Rd = 472.15 kN My,c,Rd = 29.11 kN*m Mz,c,Rd = 6.13 kN*m Vz,Ed = 3.00 kN
MN,y,Rd = 29.11 kN*m MN,z,Rd = 6.13 kN*m Vz,T,Rd = 130.99 kN
Mb,Rd = 15.83 kN*m Tt,Ed = 0.00 kN*m
Class of section = 1
----------------------------------------------------------------------------------------------------------------------------- ---------
--

51/65
LATERAL BUCKLING PARAMETERS:
z = 1.00 Mcr = 18.26 kN*m Curve,LT - b XLT = 0.54
Lcr,upp=3.58 m Lam_LT = 1.26 fi,LT = 1.24 XLT,mod = 0.54
----------------------------------------------------------------------------------------------------------------------------- ---------
--
BUCKLING PARAMETERS:

About y axis: About z axis:


kyy = 1.00 kzz = 1.00
----------------------------------------------------------------------------------------------------------------------------- ---------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nc,Rd = 0.00 < 1.00 (6.2.4.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^1.00 = 0.18 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.00 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.02 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Global stability check of member:
My,Ed,max/Mb,Rd = 0.43 < 1.00 (6.3.2.1.(1))
N,Ed/(Xy*N,Rk/gM1) + kyy*My,Ed,max/(XLT*My,Rk/gM1) + kyz*Mz,Ed,max/(Mz,Rk/gM1) = 0.56 < 1.00
(6.3.3.(4))
N,Ed/(Xz*N,Rk/gM1) + kzy*My,Ed,max/(XLT*My,Rk/gM1) + kzz*Mz,Ed,max/(Mz,Rk/gM1) = 0.56 < 1.00
(6.3.3.(4))
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 4 Traverses_IPE_120
MEMBER: 108 POINT: 1 COORDINATE: x = 0.55 L =
3.35 m
--------------------------------------------------------------------------------------------------------------------------------------
--
LOADS:
Governing Load Case: 6 ELU_NOUVELLE 1*1.35+3*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
--------------------------------------------------------------------------------------------------------------------------------------
--

SECTION PARAMETERS: IPE 120


h=120 mm gM0=1.00 gM1=1.00
b=64 mm Ay=910 mm2 Az=631 mm2 Ax=1321 mm2
tw=4 mm Iy=3177530 mm4 Iz=276682 mm4 Ix=17100 mm4
tf=6 mm Wply=60729 mm3 Wplz=13581 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
INTERNAL FORCES AND CAPACITIES:

52/65
N,Ed = -0.59 kN My,Ed = 5.78 kN*m Mz,Ed = 0.23 kN*m Vy,Ed = 0.17 kN
Nt,Rd = 310.44 kN My,pl,Rd = 14.27 kN*m Mz,pl,Rd = 3.19 kN*m Vy,T,Rd = 123.09 kN
My,c,Rd = 14.27 kN*m Mz,c,Rd = 3.19 kN*m Vz,Ed = -1.95 kN
MN,y,Rd = 14.27 kN*m MN,z,Rd = 3.19 kN*m Vz,T,Rd = 85.37 kN
Mb,Rd = 8.02 kN*m Tt,Ed = -0.00 kN*m
Class of section = 1
----------------------------------------------------------------------------------------------------------------------------- ---------
--

LATERAL BUCKLING PARAMETERS:


z = 1.00 Mcr = 9.43 kN*m Curve,LT - b XLT = 0.56
Lcr,upp=3.04 m Lam_LT = 1.23 fi,LT = 1.21 XLT,mod = 0.56
----------------------------------------------------------------------------------------------------------------------------- ---------
--
BUCKLING PARAMETERS:

About y axis: About z axis:

----------------------------------------------------------------------------------------------------------------------------- ---------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nt,Rd = 0.00 < 1.00 (6.2.3.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^1.00 = 0.24 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.00 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.02 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.01 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.01 < 1.00 (6.2.6)
Global stability check of member:
My,Ed/Mb,Rd = 0.72 < 1.00 (6.3.2.1.(1))
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 5 Traverses_IPE_200_cadre
MEMBER: 54 POINT: 3 COORDINATE: x = 0.50 L =
2.75 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 6 ELU_NOUVELLE 1*1.35+3*1.95
--------------------------------------------------------------------------------------------------------------------------------------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
----------------------------------------------------------------------------------------------------------------------------- ---------
--

SECTION PARAMETERS: IPE 200


h=200 mm gM0=1.00 gM1=1.00
b=100 mm Ay=1958 mm2 Az=1400 mm2 Ax=2848 mm2
tw=6 mm Iy=19431700 mm4 Iz=1423680 mm4 Ix=64600 mm4

53/65
tf=9 mm Wply=220657 mm3 Wplz=44614 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
INTERNAL FORCES AND CAPACITIES:
N,Ed = 1.07 kN My,Ed = 6.43 kN*m Mz,Ed = -1.37 kN*m Vy,Ed = 0.92 kN
Nc,Rd = 669.38 kN My,Ed,max = 6.43 kN*m Mz,Ed,max = 1.44 kN*m Vy,T,Rd = 265.49 kN
Nb,Rd = 669.38 kN My,c,Rd = 51.85 kN*m Mz,c,Rd = 10.48 kN*m Vz,Ed = 2.53 kN
MN,y,Rd = 51.85 kN*m MN,z,Rd = 10.48 kN*m Vz,T,Rd = 189.87 kN
Mb,Rd = 41.93 kN*m Tt,Ed = 0.00 kN*m
Class of section = 1
----------------------------------------------------------------------------------------------------------------------------- ---------
--

LATERAL BUCKLING PARAMETERS:


z = 1.00 Mcr = 63.82 kN*m Curve,LT - b XLT = 0.76
Lcr,upp=2.75 m Lam_LT = 0.90 fi,LT = 0.89 XLT,mod = 0.81
----------------------------------------------------------------------------------------------------------------------------- ---------
--
BUCKLING PARAMETERS:

About y axis: About z axis:


kyy = 1.00 kzz = 1.00
----------------------------------------------------------------------------------------------------------------------------- ---------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nc,Rd = 0.00 < 1.00 (6.2.4.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^1.00 = 0.15 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.00 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.01 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Global stability check of member:
My,Ed,max/Mb,Rd = 0.15 < 1.00 (6.3.2.1.(1))
N,Ed/(Xy*N,Rk/gM1) + kyy*My,Ed,max/(XLT*My,Rk/gM1) + kyz*Mz,Ed,max/(Mz,Rk/gM1) = 0.29 < 1.00
(6.3.3.(4))
N,Ed/(Xz*N,Rk/gM1) + kzy*My,Ed,max/(XLT*My,Rk/gM1) + kzz*Mz,Ed,max/(Mz,Rk/gM1) = 0.29 < 1.00
(6.3.3.(4))
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 6 Poutre_ceinture_IPE_300
MEMBER: 48 POINT: 1 COORDINATE: x = 0.60 L =
5.84 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 6 ELU_NOUVELLE 1*1.35+3*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa

54/65
--------------------------------------------------------------------------------------------------------------------------------------
--

SECTION PARAMETERS: IPE 300


h=300 mm gM0=1.00 gM1=1.00
b=150 mm Ay=3616 mm2 Az=2568 mm2 Ax=5381 mm2
tw=7 mm Iy=83561100 mm4 Iz=6037790 mm4 Ix=194700 mm4
tf=11 mm Wply=628399 mm3 Wplz=125222 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
INTERNAL FORCES AND CAPACITIES:
N,Ed = 0.65 kN My,Ed = 19.78 kN*m Mz,Ed = -5.97 kN*m Vy,Ed = -2.71 kN
Nc,Rd = 1264.58 kN My,Ed,max = 19.78 kN*m Mz,Ed,max = -5.97 kN*m Vy,T,Rd = 490.62 kN
Nb,Rd = 1264.58 kN My,c,Rd = 147.67 kN*m Mz,c,Rd = 29.43 kN*m Vz,Ed = -4.06 kN
MN,y,Rd = 147.67 kN*m MN,z,Rd = 29.43 kN*m Vz,T,Rd = 348.44 kN
Mb,Rd = 126.32 kN*m Tt,Ed = 0.00 kN*m
Class of section = 1
----------------------------------------------------------------------------------------------------------------------------- ---------
--

LATERAL BUCKLING PARAMETERS:


z = 1.00 Mcr = 175.96 kN*m Curve,LT - b XLT = 0.75
Lcr,upp=4.89 m Lam_LT = 0.92 fi,LT = 0.90 XLT,mod = 0.86
----------------------------------------------------------------------------------------------------------------------------- ---------
--
BUCKLING PARAMETERS:

About y axis: About z axis:


kyy = 1.00 kzz = 1.00
----------------------------------------------------------------------------------------------------------------------------- ---------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nc,Rd = 0.00 < 1.00 (6.2.4.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^1.00 = 0.22 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.01 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.01 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Global stability check of member:
My,Ed,max/Mb,Rd = 0.16 < 1.00 (6.3.2.1.(1))
N,Ed/(Xy*N,Rk/gM1) + kyy*My,Ed,max/(XLT*My,Rk/gM1) + kyz*Mz,Ed,max/(Mz,Rk/gM1) = 0.36 < 1.00
(6.3.3.(4))
N,Ed/(Xz*N,Rk/gM1) + kzy*My,Ed,max/(XLT*My,Rk/gM1) + kzz*Mz,Ed,max/(Mz,Rk/gM1) = 0.36 < 1.00
(6.3.3.(4))
---------------------------------------------------------------------------------------------------------------- ----------------------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 7 Poutre_ceinture_IPE_240
MEMBER: 70 POINT: 1 COORDINATE: x = 0.00 L =
0.00 m

55/65
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 6 ELU_NOUVELLE 1*1.35+3*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
----------------------------------------------------------------------------------------------------------------------------- ---------
--

SECTION PARAMETERS: IPE 240


h=240 mm gM0=1.00 gM1=1.00
b=120 mm Ay=2731 mm2 Az=1914 mm2 Ax=3912 mm2
tw=6 mm Iy=38916300 mm4 Iz=2836340 mm4 Ix=116000 mm4
tf=10 mm Wply=366679 mm3 Wplz=73927 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
INTERNAL FORCES AND CAPACITIES:
N,Ed = 3.01 kN My,Ed = -29.80 kN*m Mz,Ed = 0.07 kN*m Vy,Ed = 0.03 kN
Nc,Rd = 919.23 kN My,Ed,max = -29.80 kN*m Mz,Ed,max = 1.97 kN*m
Vy,T,Rd = 369.81 kN
Nb,Rd = 919.23 kN My,c,Rd = 86.17 kN*m Mz,c,Rd = 17.37 kN*m Vz,Ed = 11.31 kN
MN,y,Rd = 86.17 kN*m MN,z,Rd = 17.37 kN*m Vz,T,Rd = 259.41 kN
Mb,Rd = 53.94 kN*m Tt,Ed = -0.01 kN*m
Class of section = 1
----------------------------------------------------------------------------------------------------------------------------- ---------
--

LATERAL BUCKLING PARAMETERS:


z = 1.00 Mcr = 60.88 kN*m Curve,LT - b XLT = 0.59
Lcr,low=6.00 m Lam_LT = 1.19 fi,LT = 1.16 XLT,mod = 0.63
----------------------------------------------------------------------------------------------------------------------------- ---------
--
BUCKLING PARAMETERS:

About y axis: About z axis:


kyy = 1.00 kzz = 1.00
----------------------------------------------------------------------------------------------------------------------------- ---------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nc,Rd = 0.00 < 1.00 (6.2.4.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^1.00 = 0.12 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.00 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.04 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Global stability check of member:
My,Ed,max/Mb,Rd = 0.55 < 1.00 (6.3.2.1.(1))
N,Ed/(Xy*N,Rk/gM1) + kyy*My,Ed,max/(XLT*My,Rk/gM1) + kyz*Mz,Ed,max/(Mz,Rk/gM1) = 0.67 < 1.00
(6.3.3.(4))
N,Ed/(Xz*N,Rk/gM1) + kzy*My,Ed,max/(XLT*My,Rk/gM1) + kzz*Mz,Ed,max/(Mz,Rk/gM1) = 0.67 < 1.00
(6.3.3.(4))
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN

56/65
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 8 Traverses_IPE_140
MEMBER: 118 POINT: 1 COORDINATE: x = 0.68 L =
4.17 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 6 ELU_NOUVELLE 1*1.35+3*1.95
----------------------------------------------------------------------------------------------------------------------------- ---------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
--------------------------------------------------------------------------------------------------------------------------------------
--

SECTION PARAMETERS: IPE 140


h=140 mm gM0=1.00 gM1=1.00
b=73 mm Ay=1115 mm2 Az=764 mm2 Ax=1643 mm2
tw=5 mm Iy=5412240 mm4 Iz=449178 mm4 Ix=25400 mm4
tf=7 mm Wply=88349 mm3 Wplz=19247 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
INTERNAL FORCES AND CAPACITIES:
N,Ed = 0.02 kN My,Ed = 6.35 kN*m Mz,Ed = 0.22 kN*m Vy,Ed = 0.16 kN
Nc,Rd = 386.01 kN My,Ed,max = 6.35 kN*m Mz,Ed,max = -0.43 kN*m Vy,T,Rd = 151.30 kN
Nb,Rd = 386.01 kN My,c,Rd = 20.76 kN*m Mz,c,Rd = 4.52 kN*m Vz,Ed = -3.01 kN
MN,y,Rd = 20.76 kN*m MN,z,Rd = 4.52 kN*m Vz,T,Rd = 103.68 kN
Mb,Rd = 12.07 kN*m Tt,Ed = -0.00 kN*m
Class of section = 1
----------------------------------------------------------------------------------------------------------------------------- ---------
--

LATERAL BUCKLING PARAMETERS:


z = 1.00 Mcr = 14.51 kN*m Curve,LT - b XLT = 0.58
Lcr,upp=3.09 m Lam_LT = 1.20 fi,LT = 1.17 XLT,mod = 0.58
----------------------------------------------------------------------------------------------------------------------------- ---------
--
BUCKLING PARAMETERS:

About y axis: About z axis:


kyy = 1.00 kzz = 1.00
----------------------------------------------------------------------------------------------------------------------------- ---------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nc,Rd = 0.00 < 1.00 (6.2.4.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^1.00 = 0.14 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.00 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.03 < 1.00 (6.2.6-7)
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.00 < 1.00 (6.2.6)
Global stability check of member:
My,Ed,max/Mb,Rd = 0.53 < 1.00 (6.3.2.1.(1))
N,Ed/(Xy*N,Rk/gM1) + kyy*My,Ed,max/(XLT*My,Rk/gM1) + kyz*Mz,Ed,max/(Mz,Rk/gM1) = 0.62 < 1.00
(6.3.3.(4))

57/65
N,Ed/(Xz*N,Rk/gM1) + kzy*My,Ed,max/(XLT*My,Rk/gM1) + kzz*Mz,Ed,max/(Mz,Rk/gM1) = 0.62 < 1.00
(6.3.3.(4))
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 9 Tube_80x80_Support_cable
MEMBER: 132 POINT: 3 COORDINATE: x = 0.51 L =
0.51 m
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LOADS:
Governing Load Case: 6 ELU_NOUVELLE 1*1.35+3*1.95
--------------------------------------------------------------------------------------------------------------------------------------
--
MATERIAL:
ACIER E24 fy = 235.00 MPa
----------------------------------------------------------------------------------------------------------------------------- ---------
--

SECTION PARAMETERS: TCARRE 80x80x3.2


h=80 mm gM0=1.00 gM1=1.00
b=80 mm Ay=489 mm2 Az=489 mm2 Ax=978 mm2
tw=3 mm Iy=958500 mm4 Iz=958500 mm4 Ix=1477000 mm4
tf=3 mm Wply=28328 mm3 Wplz=28328 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
INTERNAL FORCES AND CAPACITIES:
N,Ed = 5.11 kN My,Ed = -0.22 kN*m Mz,Ed = -1.17 kN*m Vy,Ed = 2.40 kN
Nc,Rd = 229.85 kN My,pl,Rd = 6.66 kN*m Mz,pl,Rd = 6.66 kN*m Vy,T,Rd = 53.32 kN
Nb,Rd = 229.85 kN My,c,Rd = 6.66 kN*m Mz,c,Rd = 6.66 kN*m Vz,Ed = -1.11 kN
MN,y,Rd = 6.66 kN*m MN,z,Rd = 6.66 kN*m Vz,T,Rd = 53.32 kN
Tt,Ed = -1.01 kN*m
Class of section = 1
----------------------------------------------------------------------------------------------------------------------------- ---------
--

LATERAL BUCKLING PARAMETERS:


----------------------------------------------------------------------------------------------------------------------------- ---------
--
BUCKLING PARAMETERS:

About y axis: About z axis:

----------------------------------------------------------------------------------------------------------------------------- ---------
--
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nc,Rd = 0.02 < 1.00 (6.2.4.(1))
(My,Ed/MN,y,Rd)^ 1.66 + (Mz,Ed/MN,z,Rd)^1.66 = 0.06 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,T,Rd = 0.04 < 1.00 (6.2.6-7)
Vz,Ed/Vz,T,Rd = 0.02 < 1.00 (6.2.6-7)

58/65
Tau,ty,Ed/(fy/(sqrt(3)*gM0)) = 0.20 < 1.00 (6.2.6)
Tau,tz,Ed/(fy/(sqrt(3)*gM0)) = 0.20 < 1.00 (6.2.6)
--------------------------------------------------------------------------------------------------------------------------------------
--
Section OK !!!

59/65
 ELS_NOUVELLE

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 1 Poteaux_HEA_160
MEMBER: 1 POINT: COORDINATE:
----------------------------------------------------------------------------------------------------------------------------- ---------
--

SECTION PARAMETERS: HEA 160


ht=152 mm
bf=160 mm Ay=2880 mm2 Az=912 mm2 Ax=3877 mm2
tw=6 mm Iy=16729800 mm4 Iz=6155730 mm4 Ix=109000 mm4
tf=9 mm Wely=220129 mm3 Welz=76947 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LIMIT DISPLACEMENTS

Deflections (LOCAL SYSTEM): Not analyzed

Displacements (GLOBAL SYSTEM):


vx = 19 mm < vx max = L/250.00 = 24 mm Verified
Governing Load Case: 7 ELS_NOUVELLE 1*1.00+3*1.30
vy = 11 mm < vy max = L/250.00 = 24 mm Verified
Governing Load Case: 7 ELS_NOUVELLE 1*1.00+3*1.30
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 2 Traverses_IPE_300_cadre
MEMBER: 75 POINT: COORDINATE:
--------------------------------------------------------------------------------------------------------------------------------------
--

SECTION PARAMETERS: IPE 300


ht=300 mm
bf=150 mm Ay=3210 mm2 Az=2130 mm2 Ax=5381 mm2
tw=7 mm Iy=83561100 mm4 Iz=6037790 mm4 Ix=194700 mm4
tf=11 mm Wely=557074 mm3 Welz=80504 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LIMIT DISPLACEMENTS

Deflections (LOCAL SYSTEM):

60/65
uy = 5 mm < uy max = L/200.00 = 30 mm Verified
Governing Load Case: 7 ELS_NOUVELLE 1*1.00+3*1.30
uz = 2 mm < uz max = L/200.00 = 30 mm Verified
Governing Load Case: 7 ELS_NOUVELLE 1*1.00+3*1.30

Displacements (GLOBAL SYSTEM): Not analyzed


----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
--------------------------------------------------------------------------------------------------------------------------------------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 3 Traverses_IPE_160
MEMBER: 49 POINT: COORDINATE:
----------------------------------------------------------------------------------------------------------------------------- ---------
--

SECTION PARAMETERS: IPE 160


ht=160 mm
bf=82 mm Ay=1214 mm2 Az=800 mm2 Ax=2009 mm2
tw=5 mm Iy=8692930 mm4 Iz=683145 mm4 Ix=35300 mm4
tf=7 mm Wely=108662 mm3 Welz=16662 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LIMIT DISPLACEMENTS

Deflections (LOCAL SYSTEM):


uy = 8 mm < uy max = L/200.00 = 36 mm Verified
Governing Load Case: 7 ELS_NOUVELLE 1*1.00+3*1.30
uz = 9 mm < uz max = L/200.00 = 36 mm Verified
Governing Load Case: 7 ELS_NOUVELLE 1*1.00+3*1.30

Displacements (GLOBAL SYSTEM): Not analyzed


----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 4 Traverses_IPE_120
MEMBER: 107 POINT: COORDINATE:
----------------------------------------------------------------------------------------------------------------------------- ---------
--

SECTION PARAMETERS: IPE 120


ht=120 mm
bf=64 mm Ay=806 mm2 Az=528 mm2 Ax=1321 mm2

61/65
tw=4 mm Iy=3177530 mm4 Iz=276682 mm4 Ix=17100 mm4
tf=6 mm Wely=52959 mm3 Welz=8646 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LIMIT DISPLACEMENTS

Deflections (LOCAL SYSTEM):


uy = 5 mm < uy max = L/200.00 = 30 mm Verified
Governing Load Case: 7 ELS_NOUVELLE 1*1.00+3*1.30
uz = 19 mm < uz max = L/200.00 = 30 mm Verified
Governing Load Case: 7 ELS_NOUVELLE 1*1.00+3*1.30

Displacements (GLOBAL SYSTEM): Not analyzed


----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 5 Traverses_IPE_200_cadre
MEMBER: 54 POINT: COORDINATE:
--------------------------------------------------------------------------------------------------------------------------------------
--

SECTION PARAMETERS: IPE 200


ht=200 mm
bf=100 mm Ay=1700 mm2 Az=1120 mm2 Ax=2848 mm2
tw=6 mm Iy=19431700 mm4 Iz=1423680 mm4 Ix=64600 mm4
tf=9 mm Wely=194317 mm3 Welz=28474 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LIMIT DISPLACEMENTS

Deflections (LOCAL SYSTEM):


uy = 4 mm < uy max = L/200.00 = 27 mm Verified
Governing Load Case: 7 ELS_NOUVELLE 1*1.00+3*1.30
uz = 3 mm < uz max = L/200.00 = 27 mm Verified
Governing Load Case: 7 ELS_NOUVELLE 1*1.00+3*1.30

Displacements (GLOBAL SYSTEM): Not analyzed


----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
--------------------------------------------------------------------------------------------------------------------------------------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 6 Poutre_ceinture_IPE_300
MEMBER: 48 POINT: COORDINATE:

62/65
----------------------------------------------------------------------------------------------------------------------------- ---------
--

SECTION PARAMETERS: IPE 300


ht=300 mm
bf=150 mm Ay=3210 mm2 Az=2130 mm2 Ax=5381 mm2
tw=7 mm Iy=83561100 mm4 Iz=6037790 mm4 Ix=194700 mm4
tf=11 mm Wely=557074 mm3 Welz=80504 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LIMIT DISPLACEMENTS

Deflections (LOCAL SYSTEM):


uy = 9 mm < uy max = L/200.00 = 49 mm Verified
Governing Load Case: 7 ELS_NOUVELLE 1*1.00+3*1.30
uz = 5 mm < uz max = L/200.00 = 49 mm Verified
Governing Load Case: 7 ELS_NOUVELLE 1*1.00+3*1.30

Displacements (GLOBAL SYSTEM): Not analyzed


----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 7 Poutre_ceinture_IPE_240
MEMBER: 70 POINT: COORDINATE:
--------------------------------------------------------------------------------------------------------------------------------------
--

SECTION PARAMETERS: IPE 240


ht=240 mm
bf=120 mm Ay=2352 mm2 Az=1488 mm2 Ax=3912 mm2
tw=6 mm Iy=38916300 mm4 Iz=2836340 mm4 Ix=116000 mm4
tf=10 mm Wely=324302 mm3 Welz=47272 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LIMIT DISPLACEMENTS

Deflections (LOCAL SYSTEM):


uy = 10 mm < uy max = L/200.00 = 60 mm Verified
Governing Load Case: 7 ELS_NOUVELLE 1*1.00+3*1.30
uz = 25 mm < uz max = L/200.00 = 60 mm Verified
Governing Load Case: 7 ELS_NOUVELLE 1*1.00+3*1.30

Displacements (GLOBAL SYSTEM): Not analyzed


----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

STEEL DESIGN
--------------------------------------------------------------------------------------------------------------------------------------
--

63/65
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 8 Traverses_IPE_140
MEMBER: 118 POINT: COORDINATE:
--------------------------------------------------------------------------------------------------------------------------------------
--

SECTION PARAMETERS: IPE 140


ht=140 mm
bf=73 mm Ay=1007 mm2 Az=658 mm2 Ax=1643 mm2
tw=5 mm Iy=5412240 mm4 Iz=449178 mm4 Ix=25400 mm4
tf=7 mm Wely=77318 mm3 Welz=12306 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LIMIT DISPLACEMENTS

Deflections (LOCAL SYSTEM):


uy = 4 mm < uy max = L/200.00 = 31 mm Verified
Governing Load Case: 7 ELS_NOUVELLE 1*1.00+3*1.30
uz = 12 mm < uz max = L/200.00 = 31 mm Verified
Governing Load Case: 7 ELS_NOUVELLE 1*1.00+3*1.30

Displacements (GLOBAL SYSTEM): Not analyzed


--------------------------------------------------------------------------------------------------------------------------------------
--
Section OK !!!

STEEL DESIGN
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE: BS-EN 1993-1:2005/NA:2008/A1:2014, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Code Group Verification
----------------------------------------------------------------------------------------------------------------------------- ---------
--
CODE GROUP: 9 Tube_80x80_Support_cable
MEMBER: 261 Beam_261 POINT: COORDINATE:
----------------------------------------------------------------------------------------------------------------------------- ---------
--

SECTION PARAMETERS: TCARRE 80x80x3.2


ht=80 mm
bf=80 mm Ay=489 mm2 Az=489 mm2 Ax=978 mm2
tw=3 mm Iy=958500 mm4 Iz=958500 mm4 Ix=1477000 mm4
tf=3 mm Wely=23962 mm3 Welz=23962 mm3
----------------------------------------------------------------------------------------------------------------------------- ---------
--
LIMIT DISPLACEMENTS

Deflections (LOCAL SYSTEM):


uy = 6 mm < uy max = L/200.00 = 60 mm Verified
Governing Load Case: 7 ELS_NOUVELLE 1*1.00+3*1.30
uz = 37 mm < uz max = L/200.00 = 60 mm Verified
Governing Load Case: 7 ELS_NOUVELLE 1*1.00+3*1.30

Displacements (GLOBAL SYSTEM): Not analyzed

64/65
----------------------------------------------------------------------------------------------------------------------------- ---------
--
Section OK !!!

65/65

Vous aimerez peut-être aussi