Vous êtes sur la page 1sur 8

Calcul de nervure isostatique :

un plancher en corps creux de (16+5)

d=0.9*0.21=0.189m

G=5.9KN/m² et Q=1.5KN :m²

 Charges permanentes : G= 5.9 × 0.33=1.96 KN /m²

 Charges d’exploitation : Q=1.5 × 0.33=0.5 KN/m²

Calcul des sollicitations


ELU :
. Moment :
qu l 2 3.396∗1.48²
M u= = =0.92 KN . m
8 8

Effort tranchent :
qu l 3.396∗1.48
vu = = =3.72 KN
2 2

ELS :
. Moment :
q s l 2 2.46∗1.48²
M s= = =0.67 KN . m
8 8

. Calcul des armatures :


Armature longitudinale :

M tu =bt∗h t∗f cd * d− ( h2 )
t

0.05
AN : M tu =¿ 0.33*0.05*14.66* 0.189− ( 2 )
=0.039MN.m

Avec ¿ 1 car f ck =22 MPa <50 MPa


M tu =0.039> M Ed=0.00092
Section minimal:
0.26∗f ctm∗b∗d
A s ,min =max ( f yk
; 0.0013∗bt∗d )
=max ( 0.26∗2.35∗0.33∗0.189
400
; 0.0013∗0.33∗0.189 )=max (0.95 ; 0.81)=0.95cm 2

Avec: f ctm=0.3∗¿ =2.35MPa


M Ed
μu=
b d 2 f cd
0.92 .10−3
µ=
0.33∗0.1892∗14.66
=0.0053
μu=0.0053< μ AB=0.101
Calcul en pivot A
A ' s ,u=0 Par d’armature comprimée
 α u=1.25(1-√ 1−2∗μ u ¿
AN: α=1.25(1-√ 1−2∗0.0053 ¿=0.0066
 Zu =(1−0.4 α u)d
AN: Zu =0.188
Palier horizontal; S400A σ s ,u=348 MPa
M Ed
A s ,u=
σ s ,u × Zu
0.92 .10.3
AN : A s ,u= =¿ 0.139cm²
348 ×0.189
A s , u=0.139 cm ²
A s> Max
{ A s , min =0.95 cm ²

Choix : 1HA12

Calcul de poutre continue :


Détermination de charges appliquées
 Charges permanentes :

G = G plancher+ G pouter + G Mur


6.15∗3∗2.75
G plancher = =12.68 KN
4
g p=γ b∗b∗h=25∗0.22∗0.4 =2.2KN
G mur =2.8 (0.25 × 8.49¿=5.94 KN
G=12.68+2.2+5.94=20.82KN
 Charge d’exploitation :
3× 2.75
Q=1.5* =3.1KN
4
Calcul a l’ELU:
Moment fléchissant :
q u=1.35 G+1.5Q

q ELU =1.35G+1.5 Q=32.75 KN /m


 Moment sur appuis :

- Appui A = 0 KN.m

- Appui C = 0 KN.m

- Sur appuis B :

−q L31 −q L32
M A L 1 + 2 ( L1 + L2 ) M B + M C L 2 =
4
3 3
M B = −32.75∗5.91 −32.75∗3.79 = -110.094KN.m
8(5.91+3.79)

 Moment de travée AB :

q L1 q 2 x1 M B
M 1=
2
x 1− x 1 + M A 1−
2 L1( )
+ x
L1 1

32.75∗5.91 32.75 2 110.094


M1 = x 1− x 1− x1
2 2 5.91

= 78.14 x 1−16.375 x21

dM
=0 → x=2.38 m
dx

M 1 =78.14∗2.38−16.375∗2.38²

M 1 =93.22KN.m

 Moment de travée BC :

q L2 q 2 x2 M C
M 2=
2
x 2− x 2 + M B 1−
2 ( )
L2
+ x
L2 2

x
M 2 = 32.75∗3.79 x 2− 32.75 x 22−110.094 1− 2 ( )
2 2 3.79
−dM ( x)
V(x)= =0
dx

= 91.11 x 2−16.375 x 22−110.094

dM
=0 → x=2.78 m
dx

M 2= 91.11 × 2.78−16.375 ×2.78²−110.094

M 2=16.64KN.m

Effort tranchant ELU :


 Effort tranchant travée AB:

v( x)=−78.14 +32.75 x1

pour x 1=0 V 1 ( 0 )=−78.14 KN


{ pour x 1=5.91V 1 ( 5.91 )=17.16 KN

 Effort tranchant travée BC :

v 2 ( x )=−91.11+ 32.75 x 1

pour x 1=0 V 1 ( 0 )=−91.11 KN


{ pour x 1=3.79 V 1 ( 3.79 )=33.01 KN
Calcul à l’ELS :
Moment fléchissant :
q s=G+Q

q ELs =G+Q=23.92 KN /m
 Moment sur appuis :
- Appui A = 0 KN.m

- Appui C = 0 KN.m

- Sur appuis B :

−q L31 −q L32
M A L 1 + 2 ( L1 + L2 ) M B + M C L 2 =
4
3 3
M B = −23.92∗5.91 −23.92∗3.79 = -78.95KN.m
8(5.91+3.79)

Calcul d’armature :
Section minimal:
0.26∗f ctm∗b∗d
A s ,min =max ( f yk
; 0.0013∗bt∗d )
=max ( 0.26∗2.35∗0.22∗0.36
400
; 0.0013∗0.22∗0.36 )=max (1.2 ; 1.03)=1.2cm 2

Avec: f ctm=0.3∗¿ =2.35MPa


Ferraillage de la travée :
 Travée AB 
M Ed
μu= ; d=0.9*0.4=0.36m
b d 2 f cd

93.22 .10−3
µ=
0.22∗0.36 2∗14.66
=0.22
μu=0.22> μ AB=0.101
μlim ¿=0.3916¿
μ AB < μu ≤ μ lim ¿¿
 2eme cas calcule en Pivot B
A ' s ,u=0 Pas d’armature comprimée
 α u=1.25(1-√ 1−2∗μ u ¿
AN: α=1.25(1-√ 1−2∗0.22¿=0.31
 Zu =(1−0.4 α u)d
AN: Zu =0.31
1−α u
ε s= ( 3.5∗10−3 )
αu
1−0.31
AN : ε s= ( 3.5∗10−3 )=7.79 . 10−3>1.7410−3
0.31
Palier horizontal; S400  σ s ,u=F yd =348 MPa
M Ed
A s ,u=
σ s ,u × Zu
93.22 .10 .3
AN: A s ,u= =¿8.64cm²
348 × 0.31
Section minimal:

A s> Max A s ,u =8.64 cm ²


{
A s , min =1.2 cm²

Choix : 6HA14
Calcule de poteau :
1. Calcul de la descente de charge :
7.98∗2.78
S1 = =¿5.55m 2
4
2.78∗1.28
S2 = =0.89m 2
4
7.98∗1,48
S3 = =2.95m 2
4
1.48∗1.28
S4 = =¿ 0.473m 2
4
 Charge permanent du plancher :

G plancher terrasse=( g pt )( s 1+ s 2+ s3 + s 4 )= (5.9 )( 5.55+0.89+2.95+ 0.473 )

G plancher terrasse=58.19 KN

G plancher intermédiaire=( g pi ) ( s 1 +s 2+ s 3 +s 4 ) =( 6.15 ) ( 5.55+ 0.89+2.95+0.473 )

G plancher intermédiaire=60.65 KN

Q plancher =1.5 ( s 1 +s 2 +s 3 +s 4 ) =( 1.5 ) ( 5.55+ 0.89+2.95+0.473 ) =14.79 KN

Charge permanent de la poutre :

γ b bhl 25∗0.22∗0.5∗7.98
 A1 ( 22∗50 ) → g 1= = =10.97KN
2 2
γ b bhl 25∗0.22∗0.25∗2.78
 R1 ( 22∗25 ) → g 2= = =1.91KN
2 2
γ b bhl 25∗0.22∗0.25∗1.48
 R2 ( 22∗25 ) → g 3= = =1.02KN
2 2
γ b bhl 25∗0.22∗0.4∗1.28
 A2 ( 22∗40 ) → g3= = =1.41KN
2 2
1
G poutre=∑ g i=15.31 KN
3

Charge exploitation de la poutre :

bql 0.22∗1.5∗7.98
 A1 ( 22∗35 ) → q1= = =1.32KN
2 2
bql 0.22∗1.5∗2.78
 R1 ( 22∗35 ) → q1= = =0.45KN
2 2
bql 0.22∗1.5∗1.48
 R2 ( 22∗40 ) → q 1= = =0.24KN
2 2
bql 0.22∗1.5∗1.28
 A2 ( 22∗40 ) → q 1= = =0.21KN
2 2
1
Q poutre=∑ qi=2.22 KN
3

 Poids de la cloison :

3.3∗2.78
RDC (cloison 30 cm) : gc = =4.58 KN
2
1.5∗1.48
1ére étage (cloison 10 cm) : gc = =1.11 KN
2
Poids du poteau :
P p=γ p bhl
P p=2(25*0.22*0.22*3.3)=7.986KN
∑ G=163.04KN
∑ Q=34.38KN

Donc ∑1.15 G=187.5 KN


{
∑1.15 Q=39.5 KN
Effort Normal :
N ED=1.35 G+1.5 Q=312.38 KN N ser =G+Q=227 KN

2. Longueur du flambement :
Lf =0.7∗L0
Lf =0.7∗3=2.1m

3. Elancement d’un poteau :


Soit Poteau P (22*22)
L f √ 12
λ= =33.03
a
Elancement limite :
10.78 N ED 312.38 . 10.3
λ lim ¿¿ =  ; avec n= = =¿0.44
√n A c × f cd 0.22× 0.22× 14.66
10.78
A N : λlim ¿¿ = =16.25
√ 0.44
λ ≥ λ lim ¿non vérifier ¿

Lorsque : λ ≤ λlim ¿¿ on prend b=30cm

L f √ 12
λ= =24.24
b
10.78
24.24 ≤
312.38 .10.3
√ 0.3 ×h ×14.66
10.78
24.24 ≤
0.07 --> 587.57≤ 1660.12h
√ h
b ≥0.35m impossible
On prend h=0.35
 h= 35cm
Calcul d’armature :
N Ed −( A c∗f cd )
Ac =  ;σ s=348( s 400 A)
σs

312.38 10−3 −(30 ×35∗14.66 . 10−4 )


AN : A S ,u = =−35.25 cm ²
384. 10−4
0.1∗N Ed 0.1∗312.38∗10−3

A s ,min=Max
{ f yd
=
348.10−4

0.2∗A c 0.2∗35∗30
100
=
100
=0.9 cm ²

=2.1 cm²

A s> Max A s ,min =2.1 cm∧²


{A s , u=−35.25 cm ²

Vous aimerez peut-être aussi